This chapter explains how to design disaster recovery in Resource Orchestrator.
| Main Items | Reference |
|---|---|
| Switchover Methods | Refer to "2.1 Switchover Methods". |
| Switchover operations | Refer to "2.2 Switchover Operation". |
| Switchover levels | Refer to "2.3 Switchover Levels". |
| Limitation of switchover scope and additional recovery | Refer to "2.4 Limitation of switchover scope and additional recovery". |
| Configuration for blade chassis degradation | Refer to "2.5 Degrading Blade Chassis". |
| Configurations | Refer to "2.6 Configurations of the Switchover Source and Destination Sites". |
| Licenses | Refer to "2.7 Necessary Licenses". |
| Estimation of capacity of disks that will be replicated | Refer to "2.8 Estimation of Disk Capacity". |
| Estimation of capacity of disks that will not be replicated | |
| Advisory notes for Disaster Recovery environments | Refer to "2.9 Advisory Notes for Disaster Recovery Environments". |
| System configuration | Refer to "2.10 System configuration". |
The combinations of switchover methods, switchover operations, and switchover units supported by DR Option are as follows:
| Switchover Methods | Switchover operations | Switchover levels | Support Availability |
|---|---|---|---|
| "Physical L-Server switchover (physical OS)" | Active-Active Operation | Site switchover | No |
| Tenant switchover | Yes | ||
| Active-Standby Operation | Site switchover | Yes | |
| Tenant switchover | Yes | ||
| "Physical/virtual L-Server switchover (VM host/VM guest)" | Active-Active Operation | Site switchover | No |
| Tenant switchover | No | ||
| Active-Standby Operation | Site switchover | Yes | |
| Tenant switchover | No | ||
| "Virtual L-Server switchover (VM guest)" | Active-Active Operation | Site switchover | No |
| Tenant switchover | Yes | ||
| Active-Standby Operation | Site switchover | Yes | |
| Tenant switchover | Yes |
The combinations of physical servers and the Disaster Recovery function supported by DR Option are as follows:
| Function | PRIMERGY blade servers | PRIMERGY rack mount servers | SPARC Server | |
|---|---|---|---|---|
| Switchover Methods | Physical L-Server Switchover | Yes | Yes | No |
| Physical/Virtual L-Server Switchover | Yes | Yes | No | |
| Virtual L-Server Switchover | Yes | Yes | Yes | |
| Switchover operations | Active-Standby Operation | Yes | Yes | No |
| Active-Active Operation | Yes | Yes | Yes | |
| Switchover levels | Site switchover | Yes | Yes | No |
| Tenant switchover | Yes | Yes | Yes | |
| Limitation of switchover scope and additional recovery | Limitation of switchover scope | Yes | Yes | Yes |
| Additional Recovery | Yes | Yes | Yes | |
| Configuration for blade chassis degradation | Yes | - | - | |
| Switchover target | Virtual L-Servers | Yes | Yes | Yes |
| Virtual L-Servers linked with virtual servers | Yes | Yes | No | |
| Physical L-Servers | Yes | Yes | No | |
| Physical L-Servers linked with physical servers | No | No | No | |
| L-Servers with definitions only | No | No | No | |
Yes: Supported
No: Not supported
-: Not applicable