3.11.5 Client Power Control Command Messages

This section describes the messages generated by the Client Power Control command. For the messages generated by the Client Link Common command, refer to 3.11.2 Common Messages.

[Windows]0xB001:The command parameter is already in use.

[Target Commands]

Client Shutdown Command

[Windows]0xB001(YYY):The specified parameter is invalid.

[Description]

An error exists in the designation format of start-up parameters or host information definition file that you specified.

[Parameter]

YYY: System error code notified by the Task Link command

[System Action]

Terminates the process.

[User Response]

Check the designation format of start-up parameters or host information definition file.

[Target Commands]

Client Power ON Command

[Windows]0xB002:The command parameter is insufficient.

[Target Commands]

Client Shutdown Command

[Windows]0xB002(YYY):Processing cannot continue due to an internal initialization failure.

[Description]

Failed to acquire memory or read the lower level library. This could be caused because the OS is experiencing problems.

[Parameter]

YYY: System error code notified by the Task Link command

[System Action]

Terminates the process.

[User Response]

Contact your system administrator.

[System Administrator Response]

Restart the system.

If the problem cannot be resolved, collect the data of the following functions by using Maintenance Information Collection tool, and contact your Fujitsu systems engineer.

  • Server Task Link

  • Client Task Link

Depending on the options you selected during installation, one of the above functions may not exist. In that case, collect only the data of function that you can select.

[Target Commands]

Client Power ON Command

[Windows]0xB003:Invalid value was specified in the RC options.

[Target Commands]

Client Shutdown Command

[Windows]0xB004:Invalid value was specified in the RI options.

[Target Commands]

Client Shutdown Command

[Windows]0xB005:Failed to create thread.

[Target Commands]

Client Shutdown Command

[Windows]0xB005(YYY):Failed to get the Power ON process memory.

[Description]

Failed to acquire memory required during processing. This could be caused because the OS is experiencing problems.

[Parameter]

YYY: System error code notified by the Task Link command

[System Action]

Terminates the process.

[User Response]

Contact your system administrator.

[System Administrator Response]

Restart the system.

If the problem cannot be resolved, collect the data of the following functions by using Maintenance Information Collection tool, and contact your Fujitsu systems engineer.

  • Server Task Link

  • Client Task Link

Depending on the options you selected during installation, one of the above functions may not exist. In that case, collect only the data of function that you can select.

[Target Commands]

Client Power ON Command

[Windows]0xB006:Interrupted due to a message notification.

[Target Commands]

Client Shutdown Command

[Windows]0xB006(YYY):Failed to load the communication library.

[Description]

Failed to read socket library. This could be caused because there is a problem with the OS installation status.

[Parameter]

YYY: System error code notified by the Task Link command

[System Action]

Terminates the process.

[User Response]

Contact your system administrator.

[System Administrator Response]

Restart the system.

If the problem cannot be resolved, collect the data of the following functions by using Maintenance Information Collection tool, and contact your Fujitsu systems engineer.

  • Server Task Link

  • Client Task Link

Depending on the options you selected during installation, one of the above functions may not exist. In that case, collect only the data of function that you can select.

[Target Commands]

Client Power ON Command

[Windows]0xB007:The Task Link Engine process startup request was not accepted.

[Target Commands]

Client Shutdown Command

[Windows]0xB007(YYY):Processing cannot continue due to an internal initialization failure.

[Description]

Failed to acquire address of socket library function. This could be caused because the OS is experiencing problems.

[Parameter]

YYY: System error code notified by the Task Link command

[System Action]

Terminates the process.

[User Response]

Contact your system administrator.

[System Administrator Response]

Restart the system.

If the problem cannot be resolved, collect the data of the following functions by using Maintenance Information Collection tool, and contact your Fujitsu systems engineer.

  • Server Task Link

  • Client Task Link

Depending on the options you selected during installation, one of the above functions may not exist. In that case, collect only the data of function that you can select.

[Target Commands]

Client Power ON Command

[Windows]0xB008(YYY):Processing cannot continue due to an internal initialization failure.

[Description]

Failed to start internal thread. This could be caused because the OS is experiencing problems.

[Parameter]

YYY: System error code notified by the Task Link command

[System Action]

Terminates the process.

[User Response]

Contact your system administrator.

[System Administrator Response]

Restart the system.

If the problem cannot be resolved, collect the data of the following functions by using Maintenance Information Collection tool, and contact your Fujitsu systems engineer.

  • Server Task Link

  • Client Task Link

Depending on the options you selected during installation, one of the above functions may not exist. In that case, collect only the data of function that you can select.

[Target Commands]

Client Power ON Command

[Windows]0xB009(YYY):Failed to open the registry key.

[Description]

Registry information required for operating this software cannot be opened.

[Parameter]

YYY: System error code notified by the Task Link command

[System Action]

Terminates the process.

[User Response]

Contact your system administrator.

[System Administrator Response]

Re-install this software.

If the problem cannot be resolved, collect the data of the following functions by using Maintenance Information Collection tool, and contact your Fujitsu systems engineer.

  • Server Task Link

  • Client Task Link

Depending on the options you selected during installation, one of the above functions may not exist. In that case, collect only the data of function that you can select.

[Target Commands]

Client Power ON Command

[Windows]0xB00A:Either the RC options or the RI options was not specified.

[Target Commands]

Client Shutdown Command

[Windows]0xB00A(YYY):Failed to refer to the information of the registry key.

[Description]

Registry information required for operating this software cannot be accessed.

[Parameter]

YYY: System error code notified by the Task Link command

[System Action]

Terminates the process.

[User Response]

Contact your system administrator.

[System Administrator Response]

Re-install this software.

If the problem cannot be resolved, collect the data of the following functions by using Maintenance Information Collection tool, and contact your Fujitsu systems engineer.

  • Server Task Link

  • Client Task Link

Depending on the options you selected during installation, one of the above functions may not exist. In that case, collect only the data of function that you can select.

[Target Commands]

Client Power ON Command

[Windows]0xB00B(YYY):Failed to deliver the Power ON request.

[Description]

Failed to send 'Wakeup on LAN' request packet.

[Parameter]

YYY: System error code notified by the Task Link command

[System Action]

Terminates the process.

[User Response]

Contact your system administrator.

[System Administrator Response]

Check the status of network card, driver and TCP/IP protocol.

If the problem cannot be resolved, collect the data of the following functions by using Maintenance Information Collection tool, and contact your Fujitsu systems engineer.

  • Server Task Link

  • Client Task Link

Depending on the options you selected during installation, one of the above functions may not exist. In that case, collect only the data of function that you can select.

[Target Commands]

Client Power ON Command

[Windows]0xB00C(YYY):Failed to wait for Power ON confirmation.

[Description]

Failed to wait till the specified time. This could be caused because the OS is experiencing problems.

[Parameter]

YYY: System error code notified by the Task Link command

[System Action]

Terminates the process.

[User Response]

Contact your system administrator.

[System Administrator Response]

Restart the system.

If the problem cannot be resolved, collect the data of the following functions by using Maintenance Information Collection tool, and contact your Fujitsu systems engineer.

  • Server Task Link

  • Client Task Link

Depending on the options you selected during installation, one of the above functions may not exist. In that case, collect only the data of function that you can select.

[Target Commands]

Client Power ON Command

[Windows]0xB00D(YYY):Failed to confirm Power ON.

[Description]

Failed to send and receive 'ping' packet.

[Parameter]

YYY: System error code notified by the Task Link command

[System Action]

Terminates the process.

[User Response]

Contact your system administrator.

[System Administrator Response]

  • Check the TCP/IP protocol status

  • Check whether the host computer that is being powered on is the "Wakeup on LAN" compatible hardware. And it is so, make sure that "Wakeup on LAN" is enabled.

  • Make sure that the network is correctly installed on the computer that is designated with the host name of power-on target. Also, verify the network status and the registration information of DNS.

  • If you power on the client on other subnet, the network devices (e.g., routers) must be configured so that broadcast packets from server can reach the network in which the terminal being powered on locates. To learn more about the settings, see the manual of your network device.

If the problem cannot be resolved, collect the data of the following functions by using Maintenance Information Collection tool, and contact your Fujitsu systems engineer.

  • Server Task Link

  • Client Task Link

Depending on the options you selected during installation, one of the above functions may not exist. In that case, collect only the data of function that you can select.

[Target Commands]

Client Power ON Command

[Windows]0xB00F(YYY):Processing cannot continue due to an internal initialization failure.

[Description]

Failed to start using socket library. This could be caused because the OS is experiencing problems.

[Parameter]

YYY: System error code notified by the Task Link command

[System Action]

Terminates the process.

[User Response]

Contact your system administrator.

[System Administrator Response]

Restart the system.

If the problem cannot be resolved, collect the data of the following functions by using Maintenance Information Collection tool, and contact your Fujitsu systems engineer.

  • Server Task Link

  • Client Task Link

Depending on the options you selected during installation, one of the above functions may not exist. In that case, collect only the data of function that you can select.

[Target Commands]

Client Power ON Command

[Windows]0xB010(YYY):Processing cannot continue due to an internal initialization failure.

[Description]

Failed to get the host name of this command.

[Parameter]

YYY: System error code notified by the Task Link command

[System Action]

Terminates the process.

[User Response]

Contact your system administrator.

[System Administrator Response]

Restart the system.

If the problem cannot be resolved, collect the data of the following functions by using Maintenance Information Collection tool, and contact your Fujitsu systems engineer.

  • Server Task Link

  • Client Task Link

Depending on the options you selected during installation, one of the above functions may not exist. In that case, collect only the data of function that you can select.

[Target Commands]

Client Power ON Command

[Windows]0xB011:Invalid parameter was specified.

[Target Commands]

Client Shutdown Command

[Windows]0xB011(YYY):Object host cannot be found.

[Description]

Failed to resolve the address of target host that you specified.

[Parameter]

YYY: System error code notified by the Task Link command

[System Action]

Terminates the process.

[User Response]

Verify that the specified host name is correct. Contact your system administrator if the problem is not resolved.

[System Administrator Response]

Check whether the host name that you specified is registered in DNS, HOSTS file, and etc.

[Target Commands]

Client Power ON Command

[Windows]0xB012:The host name was not specified.

[Description]

Host name is not specified in the command parameter.

[System Action]

Halts the process.

[User Response]

Specify the host name in first parameter of the command.

[Target Commands]

Client Shutdown Command

[Windows]0xB012(YYY):Failed to get the communication socket.

[Description]

Failed to get the communication socket used for 'Wakeup on LAN' or 'ping'.

[Parameter]

YYY: System error code notified by the Task Link command

[System Action]

Terminates the process.

[User Response]

Contact your system administrator.

[System Administrator Response]

Check the status of network card, driver, and TCP/IP protocol.

If the problem cannot be resolved, collect the data of the following functions by using Maintenance Information Collection tool, and contact your Fujitsu systems engineer.

  • Server Task Link

  • Client Task Link

Depending on the options you selected during installation, one of the above functions may not exist. In that case, collect only the data of function that you can select.

[Target Commands]

Client Power ON Command

[Windows]0xB013:Invalid value was specified in the SD options.

[Description]

An error in the contents specified in the /SD option.

[System Action]

Halts the process.

[User Response]

Specify any of POFF, REBOOT, or DOWN in the /SD option.

[Target Commands]

Client Shutdown Command

[Windows]0xB013(YYY):Failed to deliver the request data.

[Description]

Failed to transmit 'Wakeup on LAN' packet and 'ping' packet.

[Parameter]

YYY: System error code notified by the Task Link command

[System Action]

Terminates the process.

[User Response]

Contact your system administrator.

[System Administrator Response]

Restart the system.

If the problem cannot be resolved, collect the data of the following functions by using Maintenance Information Collection tool, and contact your Fujitsu systems engineer.

  • Server Task Link

  • Client Task Link

Depending on the options you selected during installation, one of the above functions may not exist. In that case, collect only the data of function that you can select.

[Target Commands]

Client Power ON Command

[Windows]0xB014(YYY):Failed to receive the response data.

[Description]

Failed to receive a reply to 'ping'. This could be caused because the OS is experiencing problems.

[Parameter]

YYY: System error code notified by the Task Link command

[System Action]

Terminates the process.

[User Response]

Contact your system administrator.

[System Administrator Response]

Make sure that the network is not disconnected and that the communication destination system is not shut down. Re-execute the Task Link command after the network has recovered or the communication destination system has started up.

If the problem cannot be resolved, collect the data of the following functions by using Maintenance Information Collection tool, and contact your Fujitsu systems engineer.

  • Server Task Link

  • Client Task Link

Depending on the options you selected during installation, one of the above functions may not exist. In that case, collect only the data of function that you can select.

[Target Commands]

Client Power ON Command

[Windows]0xB015:The host name was not specified correctly.

[Target Commands]

Client Shutdown Command

[Windows]0xB015(YYY):Failed to wait for response data reception.

[Description]

Failed to receive a reply to 'ping'. This could be caused because the OS is experiencing problems.

[Parameter]

YYY: System error code notified by the Task Link command

[System Action]

Terminates the process.

[User Response]

Contact your system administrator.

[System Administrator Response]

Make sure that the network is not disconnected and that the communication destination system is not shut down. Re-execute the Task Link command after the network has recovered or the communication destination system has started up.

If the problem cannot be resolved, collect the data of the following functions by using Maintenance Information Collection tool, and contact your Fujitsu systems engineer.

  • Server Task Link

  • Client Task Link

Depending on the options you selected during installation, one of the above functions may not exist. In that case, collect only the data of function that you can select.

[Target Commands]

Client Power ON Command

[Windows]0xB016(YYY):Abnormality occurred in the communication socket.

[Description]

Failed to set options for the communication socket. This could be caused because the OS is experiencing problems.

[Parameter]

YYY: System error code notified by the Task Link command

[System Action]

Terminates the process.

[User Response]

Contact your system administrator.

[System Administrator Response]

Restart the system.

If the problem cannot be resolved, collect the data of the following functions by using Maintenance Information Collection tool, and contact your Fujitsu systems engineer.

  • Server Task Link

  • Client Task Link

Depending on the options you selected during installation, one of the above functions may not exist. In that case, collect only the data of function that you can select.

[Target Commands]

Client Power ON Command

[Windows]0xB017(YYY):Abnormality occurred in the communication socket.

[Description]

Failed to receive a reply to 'ping'. This could be caused because the OS is experiencing problems.

[Parameter]

YYY: System error code notified by the Task Link command

[System Action]

Terminates the process.

[User Response]

Contact your system administrator.

[System Administrator Response]

Make sure that the network is not disconnected and that the communication destination system is not shut down. Re-execute the Task Link command after the network has recovered or the communication destination system has started up.

If the problem cannot be resolved, collect the data of the following functions by using Maintenance Information Collection tool, and contact your Fujitsu systems engineer.

  • Server Task Link

  • Client Task Link

Depending on the options you selected during installation, one of the above functions may not exist. In that case, collect only the data of function that you can select.

[Target Commands]

Client Power ON Command

[Windows]0xB018(YYY):Failed to confirm Power ON.

[Description]

Cannot send 'ping' to ensure power-on. This could be caused because the OS is experiencing problems.

[Parameter]

YYY: System error code notified by the Task Link command

[System Action]

Terminates the process.

[User Response]

Contact your system administrator.

[System Administrator Response]

Restart the system.

If the problem cannot be resolved, collect the data of the following functions by using Maintenance Information Collection tool, and contact your Fujitsu systems engineer.

  • Server Task Link

  • Client Task Link

Depending on the options you selected during installation, one of the above functions may not exist. In that case, collect only the data of function that you can select.

[Target Commands]

Client Power ON Command

[Windows]0xB019(YYY):Failed to confirm Power ON.

[Description]

Failed to send 'ping' to ensure power-on. This could be caused because the OS is experiencing problems.

[Parameter]

YYY: System error code notified by the Task Link command

[System Action]

Terminates the process.

[User Response]

Contact your system administrator.

[System Administrator Response]

  • Check whether the host computer that is being powered on is the "Wakeup on LAN" compatible hardware. And it is so, make sure that "Wakeup on LAN" is enabled.

  • Make sure that the network is correctly installed on the computer that is designated with the host name of power-on target. Also, verify the network status and the registration information of DNS.

  • If you power on the client on other subnet, the network devices (e.g., routers) must be configured so that broadcast packets from server can reach the network in which the terminal being powered on locates. To learn more about the settings, see the manual of your network device.

You can make sure whether the broadcast packets can arrive or not by submitting the ping command from the command prompt window on the Operation Manager server on which you execute the command. If you receive no reply, the broadcast packet is not received by the target system.

If the IP address of submit destination is "10.90.100.100" and the subnet mask is "255.255.255.0", the submit command is "ping 10.90.100.255".

[Target Commands]

Client Power ON Command

[Windows]0xB01A(YYY):Failed to confirm Power ON.

[Description]

No respond to "ping" that was sent to ensure power-on.

[Parameter]

YYY: System error code notified by the Task Link command

[System Action]

Terminates the process.

[User Response]

Increase the amount of wait time specified in the /WT: or set a retry option.

Contact your system administrator if the problem is not resolved.

[System Administrator Response]

  • Check whether the host computer that is being powered on is the "Wakeup on LAN" compatible hardware. And it is so, make sure that "Wakeup on LAN" is enabled.

  • Make sure that the network is correctly installed on the computer that is designated with the host name of power-on target. Also, verify the network status and the registration information of DNS.

  • If you power on the client on other subnet, the network devices (e.g., routers) must be configured so that broadcast packets from server can reach the network in which the terminal being powered on locates. To learn more about the settings, see the manual of your network device.

You can make sure whether the broadcast packets can arrive or not by submitting the ping command from the command prompt window on the Operation Manager server on which you execute the command. If you receive no reply, the broadcast packet is not received by the target system.

If the IP address of submit destination is "10.90.100.100" and the subnet mask is "255.255.255.0", the submit command is "ping 10.90.100.255".

[Target Commands]

Client Power ON Command

[Windows]0xB01B(YYY):Failed to confirm Power ON.

[Description]

No respond to "ping" that was sent to ensure power-on.

[Parameter]

YYY: System error code notified by the Task Link command

[System Action]

Terminates the process.

[User Response]

Contact your system administrator.

[System Administrator Response]

  • Check whether the host computer that is being powered on is the "Wakeup on LAN" compatible hardware. And it is so, make sure that "Wakeup on LAN" is enabled.

  • Make sure that the network is correctly installed on the computer that is designated with the host name of power-on target. Also, verify the network status and the registration information of DNS.

  • If you power on the client on other subnet, the network devices (e.g., routers) must be configured so that broadcast packets from server can reach the network in which the terminal being powered on locates. To learn more about the settings, see the manual of your network device.

You can make sure whether the broadcast packets can arrive or not by submitting the ping command from the command prompt window on the Operation Manager server on which you execute the command. If you receive no reply, the broadcast packet is not received by the target system.

If the IP address of submit destination is "10.90.100.100" and the subnet mask is "255.255.255.0", the submit command is "ping 10.90.100.255".

[Target Commands]

Client Power ON Command

[Windows]0xB032(YYY):Failed to get the MAC address from the host information definition.

[Description]

Host information definition file does not exist or the information of target host is not defined.

[Parameter]

YYY: System error code notified by the Task Link command

[System Action]

Terminates the process.

[User Response]

Verify that the host information definition file exists in the directory given in the Systemwalker Operation Manager Installation Guide or the information of the target host is defined.

[Target Commands]

Client Power ON Command

[Windows]0xB033(YYY):Failed to get the IP address from the host information definition.

[Description]

Host information definition file does not exist or the information of target host is not defined.

[Parameter]

YYY: System error code notified by the Task Link command

[System Action]

Terminates the process.

[User Response]

Verify that the host information definition file exists in the directory given in the Systemwalker Operation Manager Installation Guide or the information of the target host is defined.

[Target Commands]

Client Power ON Command

[Windows]0xB034(YYY):Failed to get the subnet mask from the host information definition.

[Description]

Host information definition file does not exist or the information of target host is not defined.

[Parameter]

YYY: System error code notified by the Task Link command

[System Action]

Terminates the process.

[User Response]

Verify that the host information definition file exists in the directory given in the Systemwalker Operation Manager Installation Guide or the information of the target host is defined.

[Target Commands]

Client Power ON Command

[Windows]0xB0FE(YYY):Terminates the process.

[Description]

Process was stopped by aborting the command. The command was aborted before completing the process.

[Parameter]

YYY: System error code notified by the Task Link command

[Target Commands]

Client Power ON Command

[UNIX]0xC001(YYY):The specified parameter is invalid.

[Description]

An error exists in the designation format of start-up parameters or host information definition file.

[Parameter]

YYY: System error code notified by the Task Link command

[System Action]

Process is interrupted

[User Response]

Check the designation format of start-up parameters or host information definition file.

For more details about the host information files, see the Systemwalker Operation Manager Installation Guide.

[Target Commands]

Client Power ON Command

[UNIX]0xC005(YYY):Failed to get the Power ON process memory.

[Description]

Failed to acquire memory required during processing. This could be caused because the OS is experiencing problems.

[Parameter]

YYY: System error code notified by the Task Link command

[System Action]

Process is interrupted

[User Response]

Contact your system administrator.

[System Administrator Response]

Restart the system.

If the problem cannot be resolved, collect the data of the following functions by using Maintenance Information Collection tool, and contact your Fujitsu systems engineer.

  • Server Task Link

  • Client Task Link

Depending on the options you selected during installation, one of the above functions may not exist. In that case, collect only the data of function that you can select.

[Target Commands]

Client Power ON Command

[UNIX]0xC007(YYY):Processing cannot continue due to an internal initialization failure.

[Description]

Failed to acquire address of socket library function. This could be caused because the OS is experiencing problems.

[Parameter]

YYY: System error code notified by the Task Link command

[System Action]

Terminates the process.

[User Response]

Contact your system administrator.

[System Administrator Response]

Restart the system.

If the problem cannot be resolved, collect the data of the following functions by using Maintenance Information Collection tool, and contact your Fujitsu systems engineer.

  • Server Task Link

  • Client Task Link

Depending on the options you selected during installation, one of the above functions may not exist. In that case, collect only the data of function that you can select.

[Target Commands]

Client Power ON Command

[UNIX]0xC00B(YYY):Failed to deliver the Power ON request.

[Description]

Failed to send 'Wakeup on LAN' request packet.

[Parameter]

YYY: System error code notified by the Task Link command

[System Action]

Terminates the process.

[User Response]

Contact your system administrator.

[System Administrator Response]

Check the status of network card, driver and TCP/IP protocol.

If the problem cannot be resolved, collect the data of the following functions by using Maintenance Information Collection tool, and contact your Fujitsu systems engineer.

  • Server Task Link

  • Client Task Link

Depending on the options you selected during installation, one of the above functions may not exist. In that case, collect only the data of function that you can select.

[Target Commands]

Client Power ON Command

[UNIX]0xC00C(YYY):Failed to wait for Power ON confirmation.

[Description]

Failed to wait till the specified time. This could be caused because the OS is experiencing problems.

[Parameter]

YYY: System error code notified by the Task Link command

[System Action]

Terminates the process.

[User Response]

Contact your system administrator.

[System Administrator Response]

Restart the system.

If the problem cannot be resolved, collect the data of the following functions by using Maintenance Information Collection tool, and contact your Fujitsu systems engineer.

  • Server Task Link

  • Client Task Link

Depending on the options you selected during installation, one of the above functions may not exist. In that case, collect only the data of function that you can select.

[Target Commands]

Client Power ON Command

[UNIX]0xC00D(YYY):Failed to confirm Power ON.

[Description]

Failed to send or receive 'ping' packet.

[Parameter]

YYY: System error code notified by the Task Link command

[System Action]

Terminates the process.

[User Response]

Contact your system administrator.

[System Administrator Response]

  • Check the TCP/IP protocol status

  • Check whether the host computer that is being powered on is the "Wakeup on LAN" compatible hardware. And it is so, make sure that "Wakeup on LAN" is enabled.

  • Make sure that the network is correctly installed on the computer that is designated with the host name of power-on target. Also, verify the network status and the registration information of DNS.

  • If you power on the client on other subnet, the network devices (e.g., routers) must be configured so that broadcast packets from server can reach the network in which the terminal being powered on locates. To learn more about the settings, see the manual of your network device.

If the problem cannot be resolved, collect the data of the following functions by using Maintenance Information Collection tool, and contact your Fujitsu systems engineer.

  • Server Task Link

  • Client Task Link

Depending on the options you selected during installation, one of the above functions may not exist. In that case, collect only the data of function that you can select.

[Target Commands]

Client Power ON Command

[UNIX]0xC010(YYY):Processing cannot continue due to an internal initialization failure.

[Description]

Failed to get the host name of this command.

[Parameter]

YYY: System error code notified by the Task Link command

[System Action]

Terminates the process.

[User Response]

Contact your system administrator.

[System Administrator Response]

Check the status of network card, driver, and TCP/IP protocol.

If the problem cannot be resolved, collect the data of the following functions by using Maintenance Information Collection tool, and contact your Fujitsu systems engineer.

  • Server Task Link

  • Client Task Link

Depending on the options you selected during installation, one of the above functions may not exist. In that case, collect only the data of function that you can select.

[Target Commands]

Client Power ON Command

[UNIX]0xC011(YYY):Object host cannot be found.

[Description]

Failed to resolve the address of target host that you specified.

[Parameter]

YYY: System error code notified by the Task Link command

[System Action]

Terminates the process.

[User Response]

Check whether the target host name that you specified is correct. Contact your system administrator if the problem is not resolved.

[System Administrator Response]

Check whether host name is registered in DNS, HOSTS file, and etc.

[Target Commands]

Client Power ON Command

[UNIX]0xC012(YYY):Failed to get the communication socket.

[Description]

Failed to get the communication socket used for 'Wakeup on LAN' or 'ping'.

[Parameter]

YYY: System error code notified by the Task Link command

[System Action]

Terminates the process.

[User Response]

Contact your system administrator.

[System Administrator Response]

Check the status of network card, driver, and TCP/IP protocol.

If the problem cannot be resolved, collect the data of the following functions by using Maintenance Information Collection tool, and contact your Fujitsu systems engineer.

  • Server Task Link

  • Client Task Link

Depending on the options you selected during installation, one of the above functions may not exist. In that case, collect only the data of function that you can select.

[Target Commands]

Client Power ON Command

[UNIX]0xC013(YYY):Failed to deliver the request data.

[Description]

Failed to transmit 'Wakeup on LAN' packet or 'ping' packet.

[Parameter]

YYY: System error code notified by the Task Link command

[System Action]

Terminates the process.

[User Response]

Contact your system administrator.

[System Administrator Response]

Restart the system.

If the problem cannot be resolved, collect the data of the following functions by using Maintenance Information Collection tool, and contact your Fujitsu systems engineer.

  • Server Task Link

  • Client Task Link

Depending on the options you selected during installation, one of the above functions may not exist. In that case, collect only the data of function that you can select.

[Target Commands]

Client Power ON Command

[UNIX]0xC014(YYY):Failed to receive the response data.

[Description]

Failed to receive a reply to 'ping'. This could be caused because the OS is experiencing problems.

[Parameter]

YYY: System error code notified by the Task Link command

[System Action]

Terminates the process.

[User Response]

Contact your system administrator.

[System Administrator Response]

Restart the system.

If the problem cannot be resolved, collect the data of the following functions by using Maintenance Information Collection tool, and contact your Fujitsu systems engineer.

  • Server Task Link

  • Client Task Link

Depending on the options you selected during installation, one of the above functions may not exist. In that case, collect only the data of function that you can select.

[Target Commands]

Client Power ON Command

[UNIX]0xC015(YYY):Failed to wait for response data reception.

[Description]

Failed to receive a reply to 'ping'. This could be caused because the OS is experiencing problems.

[Parameter]

YYY: System error code notified by the Task Link command

[System Action]

Terminates the process.

[User Response]

Contact your system administrator.

[System Administrator Response]

Restart the system.

If the problem cannot be resolved, collect the data of the following functions by using Maintenance Information Collection tool, and contact your Fujitsu systems engineer.

  • Server Task Link

  • Client Task Link

Depending on the options you selected during installation, one of the above functions may not exist. In that case, collect only the data of function that you can select.

[Target Commands]

Client Power ON Command

[UNIX]0xC016(YYY):Abnormality occurred in the communication socket.

[Description]

Failed to set options for the communication socket. This could be caused because the OS is experiencing problems.

[Parameter]

YYY: System error code notified by the Task Link command

[System Action]

Terminates the process.

[User Response]

Contact your system administrator.

[System Administrator Response]

Restart the system.

If the problem cannot be resolved, collect the data of the following functions by using Maintenance Information Collection tool, and contact your Fujitsu systems engineer.

  • Server Task Link

  • Client Task Link

Depending on the options you selected during installation, one of the above functions may not exist. In that case, collect only the data of function that you can select.

[Target Commands]

Client Power ON Command

[UNIX]0xC017(YYY):Abnormality occurred in the communication socket.

[Description]

Failed to receive a reply to 'ping'. This could be caused because the OS is experiencing problems.

[Parameter]

YYY: System error code notified by the Task Link command

[System Action]

Terminates the process.

[User Response]

Contact your system administrator.

[System Administrator Response]

Restart the system.

If the problem cannot be resolved, collect the data of the following functions by using Maintenance Information Collection tool, and contact your Fujitsu systems engineer.

  • Server Task Link

  • Client Task Link

Depending on the options you selected during installation, one of the above functions may not exist. In that case, collect only the data of function that you can select.

[Target Commands]

Client Power ON Command

[UNIX]0xC018(YYY):Failed to confirm Power ON.

[Description]

Cannot send 'ping' to ensure power-on. This could be caused because the OS is experiencing problems.

[Parameter]

YYY: System error code notified by the Task Link command

[System Action]

Terminates the process.

[User Response]

Contact your system administrator.

[System Administrator Response]

Restart the system.

If the problem cannot be resolved, collect the data of the following functions by using Maintenance Information Collection tool, and contact your Fujitsu systems engineer.

  • Server Task Link

  • Client Task Link

Depending on the options you selected during installation, one of the above functions may not exist. In that case, collect only the data of function that you can select.

[Target Commands]

Client Power ON Command

[UNIX]0xC019(YYY):Failed to confirm Power ON.

[Description]

Failed to send 'ping' to ensure power-on. This could be caused because the OS is experiencing problems.

[Parameter]

YYY: System error code notified by the Task Link command

[System Action]

Terminates the process.

[User Response]

Contact your system administrator.

[System Administrator Response]

  • Check whether the host computer that is being powered on is the "Wakeup on LAN" compatible hardware. And it is so, make sure that "Wakeup on LAN" is enabled.

  • Make sure that the network is correctly installed on the computer that is designated with the host name of power-on target. Also, verify the network status and the registration information of DNS.

  • If you power on the client on other subnet, the network devices (e.g., routers) must be configured so that broadcast packets from server can reach the network in which the terminal being powered on locates. To learn more about the settings, see the manual of your network device.

You can make sure whether the broadcast packets can arrive or not by submitting the ping command from the command prompt window on the Operation Manager server on which you execute the command. If you receive no reply, the broadcast packet is not received by the target system.

If the IP address of submit destination is "10.90.100.100" and the subnet mask is "255.255.255.0", the submit command is "ping 10.90.100.255".

[Target Commands]

Client Power ON Command

[UNIX]0xC01A(YYY):Failed to confirm Power ON.

[Description]

No respond to "ping" that was sent to ensure power-on.

[Parameter]

YYY: System error code notified by the Task Link command

[System Action]

Terminates the process.

[User Response]

Increase the amount of wait time specified in the /wt: or set a retry option.

Contact your system administrator if the problem is not resolved.

[System Administrator Response]

  • Check whether the host computer that is being powered on is the "Wakeup on LAN" compatible hardware. And it is so, make sure that "Wakeup on LAN" is enabled.

  • Make sure that the network is correctly installed on the computer that is designated with the host name of power-on target. Also, verify the network status and the registration information of DNS.

  • If you power on the client on other subnet, the network devices (e.g., routers) must be configured so that broadcast packets from server can reach the network in which the terminal being powered on locates. To learn more about the settings, see the manual of your network device.

You can make sure whether the broadcast packets can arrive or not by submitting the ping command from the command prompt window on the Operation Manager server on which you execute the command. If you receive no reply, the broadcast packet is not received by the target system.

  • If the IP address of submit destination is "10.90.100.100" and the subnet mask is "255.255.255.0", the submit command is "ping 10.90.100.255".

[Target Commands]

Client Power ON Command

[UNIX]0xC01B(YYY):Failed to confirm Power ON.

[Description]

No respond to "ping" that was sent to ensure power-on.

[Parameter]

YYY: System error code notified by the Task Link command

[System Action]

Terminates the process.

[User Response]

Contact your system administrator.

[System Administrator Response]

  • Check whether the host computer that is being powered on is the "Wakeup on LAN" compatible hardware. And it is so, make sure that "Wakeup on LAN" is enabled.

  • Make sure that the network is correctly installed on the computer that is designated with the host name of power-on target. Also, verify the network status and the registration information of DNS.

  • If you power on the client on other subnet, the network devices (e.g., routers) must be configured so that broadcast packets from server can reach the network in which the terminal being powered on locates. To learn more about the settings, see the manual of your network device.

You can make sure whether the broadcast packets can arrive or not by submitting the ping command from the command prompt window on the Operation Manager server on which you execute the command. If you receive no reply, the broadcast packet is not received by the target system.

  • If the IP address of submit destination is "10.90.100.100" and the subnet mask is "255.255.255.0", the submit command is "ping 10.90.100.255".

[Target Commands]

Client Power ON Command

[UNIX]0xC032(YYY):Failed to get the MAC address from the host information definition.

[Description]

Host information definition file does not exist or the information of target host is not defined.

[Parameter]

YYY: System error code notified by the Task Link command

[System Action]

Terminates the process.

[User Response]

Verify that the host information definition file exists in the directory given in the Systemwalker Operation Manager Installation Guide or the information of the target host is defined.

[Target Commands]

Client Power ON Command

[UNIX]0xC033(YYY):Failed to get the IP address from the host information definition.

[Description]

Host information definition file does not exist or the information of target host is not defined.

[Parameter]

YYY: System error code notified by the Task Link command

[System Action]

Terminates the process.

[User Response]

Verify that the host information definition file exists in the directory given in the Systemwalker Operation Manager Installation Guide or the information of the target host is defined.

[Target Commands]

Client Power ON Command

[UNIX]0xC034(YYY):Failed to get the subnet mask from the host information definition.

[Description]

Host information definition file does not exist or the information of target host is not defined.

[Parameter]

YYY: System error code notified by the Task Link command

[System Action]

Terminates the process.

[User Response]

Verify that the host information definition file exists in the directory given in the Systemwalker Operation Manager Installation Guide or the information of the target host is defined.

[Target Commands]

Client Power ON Command

[UNIX]0xC0FE(YYY):Terminates the process.

[Description]

Process was stopped by aborting the command. The command was aborted before completing the process.

[Parameter]

YYY: System error code notified by the Task Link command

[Target Commands]

Client Power ON Command

[UNIX]0xC101:The command parameter is already in use.

[Description]

Overlapped command parameter is specified.

[System Action]

Terminates the process.

[User Response]

Remove the overlapped command parameter.

[Target Commands]

Client Shutdown Command

[UNIX]0xC102:The command parameter is insufficient.

[Description]

Correct command parameter is not specified.

[System Action]

Terminates the process.

[User Response]

Correct the command parameter.

[Target Commands]

Client Shutdown Command

[UNIX]0xC103:Invalid value was specified in the rc options.

[Description]

Invalid value or character string is specified in the option to specify the number of retry.

[System Action]

Terminates the process.

[User Response]

Specify the numeric value with the range of 0 to 99 in the /rc: option.

[Target Commands]

Client Shutdown Command

[UNIX]0xC104:Invalid value was specified in the ri options.

[Description]

Invalid string or value is specified in the option to specify retry intervals.

[System Action]

Terminates the process.

[User Response]

Specify the numeric value with the range of 0 to 9999 in the /ri: option.

[Target Commands]

Client Shutdown Command

[UNIX]0xC105:Either the rc options or the ri options was not specified.

[Description]

The /rc option is specified and the /ri option is not specified, or the /ri option is specified and the /rc option is not specified.

[System Action]

Terminates the process.

[User Response]

Specify both /rc and /ri options when you set the retry options.

[Target Commands]

Client Shutdown Command

[UNIX]0xC106:Invalid parameter was specified.

[Description]

Option that cannot be used in the command parameter is specified.

[System Action]

Terminates the process.

[User Response]

Review the command parameter.

[Target Commands]

Client Shutdown Command

[UNIX]0xC107:The host name was not specified.

[Description]

Host name is not specified in the command parameters.

[System Action]

Terminates the process.

[User Response]

Specify the host name in the first parameter of the command.

[Target Commands]

Client Shutdown Command

[UNIX]0xC108:Invalid value was specified in the sd options.

[Description]

An error exists in the contents specified in the /sd: option.

[System Action]

Terminates the process.

[User Response]

Specify any of poff, reboot, or down in the /sd: option.

[Target Commands]

Client Shutdown Command

[UNIX]0xC109:The host name was not specified correctly.

[Description]

Host name is not correctly specified in the command parameter.

[System Action]

Terminates the process.

[User Response]

Check the length of the host name or invalid character string is included.

[Target Commands]

Client Shutdown Command

[UNIX]0xC10A:Interrupted due to a message notification.

[Description]

Process was stopped by aborting the command.

[Target Commands]

Client Shutdown Command

[UNIX]0xC10B:The Task Link Engine process startup request was not accepted.

[Description]

  • The Client Task Link is not activated on the specified client.

  • The specified client cannot be found.

[System Action]

Terminates the process.

[User Response]

  • Check the host name of the specified client.

  • Start the Client Task Link on the specified client.

Contact your system administrator if the problem persists.

[System Administrator Response]

  • Verify if the ping command can work normally using the host name of the client specified by user.

  • Check the network status whether security products, such as a Windows firewall, may interfere with the communication.

[Target Commands]

Client Shutdown Command