Top
Interstage Big DataParallel Processing ServerV1.0.1 User's Guide
FUJITSU Software

6.2.1 Installing the Slave Server Functionality

The procedure for installing the slave server functionality is shown below.

  1. Creating bdpp.conf

  2. Installing the Slave Server Functionality

  3. Applying Software Updates


6.2.1.1 Creating bdpp.conf

Before installing the slave server functionality, set the previously designed values in bdpp.conf.

See

Refer to "Slave server" under "B.1 bdpp.conf" for information on bdpp.conf.


6.2.1.2 Installing the Slave Server Functionality

Follow the procedures below to install the slave server functionality.

  1. Set the "BDPP_CONF_PATH" environment variable.
    In the "BDPP_CONF_PATH" environment variable, set the directory where bdpp.conf is stored.

    Example

    If bdpp.conf is stored in /home/data/slaves:

    # export BDPP_CONF_PATH=/home/data/slave <Enter>
  2. Mount the DVD-ROM.
    Place the DVD-ROM in the DVD drive, then execute the command below to mount the DVD-ROM. If the DVD-ROM is automatically mounted by the automatic mount daemon (autofs), installer startup will fail because "noexec" is set in the mount options.

    # mount /dev/hdc dvdRomMountPoint <Enter>
  3. Start the installer.
    Execute bdpp_inst to start the installer.

    # dvdRomMountPoint/bdpp_inst <Enter>
  4. Select "2. Slave Server installation".

    ================================================================================
                     Interstage Big Data Parallel Processing Server
                                        V1.0.1
                All Rights Reserved, Copyright(c) FUJITSU LIMITED 2012
    ================================================================================
    
    << Menu >>
    
    1. Master Server installation
    2. Slave Server installation
    3. Development Server installation
    4. Collaboration Server installation
    
    ================================================================================
    Please select number to start specified Server installation [?,q]
    => 2 <Enter>
  5. After installation is completed, restart the system.

    # shutdown -r now <Enter>

Note

If installation fails, refer to the messages output during the installation operation and/or installation log file (/var/tmp/bdpp_install.log) to diagnose the failure. Then, remove the cause of the failure and perform installation again.


6.2.1.3 Applying Software Updates

After installing the slave server functionality, apply the updates for this product and the updates for software included with this product.