Top
ETERNUS SF Storage Cruiser 14.0 User's Guidefor Virtual Storage Conductor

E.1 VSC Manager

This appendix describes the error messages output by VSC Manager.

Either English or Japanese messages are output as specified in environment variable LANG.

Messages output by VSC Manager consist of those output to the system log and those output to the operator terminal.


Message output format

VSC Manager outputs messages in the following output format:

label: error_type: message_ID:  message_text
Labels

VSC Manager outputs messages with the following labels:

Label

Meaning

FSP_FJSVssvsc_Service

Common service

FSP_FJSVssvsc_Virtual

Virtual disk operation

FSP_FJSVssvsc_Copy

Migration or replication operation

FSP_FJSVssvsc_Mainte

Maintenance operation

Error type

VSC Manager outputs messages with the following error types:

Error type

Meaning

ERR

Take action as instructed.

WARNING

Take any action required as instructed.

INFO

The system administrator need not take any action.

Table E.1 Items in message text

Item

Description

Message text

Text of a message to be output. Each message is output in the following format:

Message ID : Message text

Explanation

Explains why this message is output.

Parameters

Explains the meanings of any parameters included in the message.

User action

Explains the action to be taken for this message.


ssvsc0000

ssvsc0000: System error occurred.

Explanation

An unexpected error occurred.

User action

Referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

ssvsc0001

ssvsc0001: Command name is invalid.

Explanation

The command name is invalid.

User action

Specify a correct command name.
For more information, refer to "Appendix B Admin Server Commands".

ssvsc0002

ssvsc0002: Input form of an option is invalid.

Explanation

An option is in an incorrect input form.

User action

Confirm that:

  • A value is specified after an option that requires a value.

  • A value is not specified after an option that doest not require a value

  • A correct option is specified.

  • No option is specified more than once.

  • Only one value is specified after an option.

For more information, refer to "Appendix B Admin Server Commands".

ssvsc0003

ssvsc0003: Command name is not specified.

Explanation

No command string is specified.

User action

Refer to "Appendix B Admin Server Commands", and specify a command.

ssvsc0004

ssvsc0004: The h option and other options are specified simultaneously.

Explanation

The -h option and other options are specified simultaneously.

User action

The -h option cannot be specified simultaneously with other options.
To specify help, specify the -h option alone.
For more information, refer to "Appendix B Admin Server Commands".

ssvsc0005

ssvsc0005: The value of an option is invalid. Option = {0}

Explanation

An option has an invalid value.

Parameters

Option with an invalid value specified

User action

Confirm that the %Option values:

  • Are the correct character type.

  • Are the correct length.

  • Are within the correct specification range.

  • Are correctly delimited with a comma or colon.

  • Consist of as many values as required.

Re-enter the command with the option specified in a valid form.
For more information, refer to "Appendix B Admin Server Commands".

ssvsc0006

ssvsc0006: The required option is not specified.

Explanation

A mandatory option is not specified.

User action

Re-enter the command with the mandatory option specified.
For more information, refer to "Appendix B Admin Server Commands".

ssvsc0007

ssvsc0007: The same virtualization switch host name is specified.

Explanation

There is already an existing virtualization switch with the specified host name.

User action

Specify a unique name for the virtualization switch.
For more information, refer to "Appendix B Admin Server Commands".

ssvsc0008

ssvsc0008: The same virtual target name is specified.

Explanation

The specified virtual target name already exists.

User action

Specify a unique name for the virtual target.
For more information, refer to "Appendix B Admin Server Commands".

ssvsc0009

ssvsc0009: The same combination of WWN and host-lun is specified.

Explanation

The specified combination of a WWN and LUN already exists.

User action

Specify a unique combination of a WWN and LUN.
For more information, refer to "Appendix B Admin Server Commands".

ssvsc0010

ssvsc0010: The same real disk name is specified.

Explanation

The specified physical disk name already exists.

User action

Specify a unique name for the physical disk.
For more information, refer to "Appendix B Admin Server Commands"

ssvsc0101

ssvsc0101: A mismatch was found in composition data files of virtual storage. SwitchName = {0}

Explanation

A mismatch was found in the configuration information between virtual switch = {0} and VSC Manager.

Parameters

0: The name of the virtual switch that does not match the configuration information

For virtualization switches other than the VS900 Model 200, the name of the virtualization switch is displayed as “virtualization switch name (host name)”.

User action

Perform the following for the virtualization switch (%SwitchName):

  1. Restore the configuration information by referring to "6.2.3.3 Restoring the configuration information of a virtualization switch".

  2. Confirm that the status of the configuration information of %SwitchName matches that on the Virtual Storage Window (Maintenance). Alternatively, using the getvsw command, confirm that the ConfigFile for %SwitchName has the correct status.

ssvsc0102

ssvsc0102: A mismatching data was found in configuration data files. Item = {0}

Explanation

The configuration data file contains %Item with an incorrectly specified value.

Parameters

0: Name of the item with an incorrectly specified value

User action

Verify the value specified for %Item in the configuration data file.

Correct any incorrect value, and restart the manager.

If it is not operating normally, refer to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

ssvsc0103

ssvsc0103: Unable to connect to the VSC manager. The VSC manager address is {0}:{1}.

Explanation

No connection to VSC Manager can be established from the Virtual Storage Window (View and Create). VSC Manager may not be operating normally.

Parameters

0: IP address

1: Port number

User action

Confirm that VSC Manager is operating normally.

If it is not operating normally, refer to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

ssvsc0104

ssvsc0104: Unable to access to the VSC manager. The VSC manager address is {0}:{1}.

Explanation

No connection to VSC Manager can be established from the Virtual Storage Window. The VSC Manager may not be operating normally.

Parameters

0: IP address
1: Port number

User action

Confirm that VSC Manager is operating normally.

If it is not operating normally, refer to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

ssvsc0105

ssvsc0105: Unrecoverable error has been detected in communication between client and VSC manager. The VSC manager address is {0}:{1}.

Explanation

An unrecoverable error was detected in communication between the Virtual Storage Window and VSC Manager. VSC Manager probably ended abnormally during communication, or the Virtual Storage Window and VSC Manager may have versions that do not match.

Parameters

0: IP address
1: Port number

User action

Confirm that VSC Manager is operating normally, or verify the versions of the Virtual Storage Window and VSC Manager. If VSC Manager is not operating normally, refer to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

ssvsc0106

ssvsc0106: VSC Manager does not start yet.

Explanation

VSC Manager is not running.

User action

Re-execute the manager command.

If the problem persists, refer to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

ssvsc0107

ssvsc0107: The specified virtualization switch is already invalid. Host name = {0}

Explanation

The user attempted to disable a virtualization switch, but it has already been disabled.

Parameters

0: Virtualization switch name (host name)

User action

Refresh the Virtual Storage (Maintenance) window. Then check whether the specified virtualization switch has been enabled in the Virtual Storage (Maintenance) window.

ssvsc0108

ssvsc0108: The specified virtualization switch is already valid. Host name = {0}

Explanation

The user attempted to enable a virtualization switch, but it has already been enabled.

Parameters

0: Virtualization switch name (host name)

User action

Refresh the Virtual Storage (Maintenance) window. Then check whether the specified virtualization switch has been disabled in the Virtual Storage (Maintenance) window.

ssvsc0109

ssvsc0109: The slot position of the virtualization blade may be different from a position of registered information. Host name = {0}

Explanation

The virtualization blade may have been inserted into the wrong slot.

Parameters

0: Virtualization switch name (host name)

User action

Check the insertion position for the virtualization blade.

Otherwise, update the management status of physical resources to the latest status, and then execute the processing again

If the problem persists, refer to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

ssvsc0110

ssvsc0110: A mismatching data was found in the specified switch name. Switch name = {0}

Explanation

The name of the switch may not match the registered information.

Parameters

0: Virtualization switch name (host name)

User action

Check whether the specified switch name is correct.

ssvsc0111

ssvsc0111: The slot position and serial number of the specified virtualization blade are different from registered information. Switch name = {0}

Explanation

The slot position and serial number of a virtualization blade do not match the registered information.

Parameters

0: Virtualization switch name (host name)

User action

When replacing virtualization blades, make sure that the new virtualization blade is inserted into the same slot as the old virtualization blade. When changing the slot position for a virtualization blade, make sure the serial number is the same as before.

ssvsc0200

ssvsc0200: Since processing in which it did not complete in virtualization switch was canceled, Discontinuing the processing which is required. Host name = {0}

Explanation

The requested processing could not be executed because processing was in progress on the virtualization switch.

The processing in progress was canceled.

Parameters

0: Virtualization switch name (host name)

User action

Perform the operation again.

If the problem persists, refer to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

ssvsc0201

ssvsc0201: The specified virtualization switch name is not registered.

Explanation

The host name of the virtualization switch is incorrect, or the virtualization switch is not registered.

User action

Confirm that the virtualization switch specified in the Virtual Storage Window (Maintenance) exists. Also, use the getvsw command to check whether the virtualization switch is registered. Then, specify the correct host name for the virtualization switch, or register the virtualization switch.

ssvsc0202

ssvsc0202: The specified virtual storage pool name already exists.

Explanation

Multiple virtual storage pools cannot be created with the same name.

User action

Check virtual storage pool names in the Virtual Storage Window (View and Create), and specify a virtual storage pool name not being used.

ssvsc0203

ssvsc0203: The specified virtual storage pool does not exist.

Explanation

The specified name of the virtual storage pool is incorrect. Alternatively, the specified virtual storage pool does not exist.

User action

Check the virtual storage pool name on the Virtual Storage Window (View and Create).

ssvsc0204

ssvsc0204: The specified physical disk name already exists.

Explanation

Multiple physical disks cannot be registered with the same name.

User action

Check physical disk names in the Virtual Storage Window (View and Create), and specify a physical disk name not being used.

ssvsc0205

ssvsc0205: The specified physical disk does not exist.

Explanation

The specified physical disk name is incorrect. Alternatively, the specified physical disk doesn't exist.

User action

In the Virtual Storage Window(View and Create), check the physical disk name.

ssvsc0206

ssvsc0206: The specified virtual enclosure name already exists.

Explanation

An attempt was made to create a virtual enclosure with an existing name.

User action

Check virtual enclosure names in the Virtual Storage Window (View and Create).

ssvsc0207

ssvsc0207: The specified virtual enclosure does not exist.

Explanation

The specified virtual enclosure name is incorrect. Alternatively, the specified virtual enclosure doesn't exist.

User action

Check virtual enclosure names in the Virtual Storage Window (View and Create).

ssvsc0208

ssvsc0208: The specified virtual target name already exists.

Explanation

Multiple virtual targets cannot be created with the same name.

User action

Check virtual target names in the Virtual Storage Window (View and Create), and specify a virtual target name not being used.

ssvsc0209

ssvsc0209: The specified virtual target does not exist.

Explanation

The virtual target name is incorrect. Alternatively, the specified virtual target doesn't exist.

User action

Check virtual target names in the Virtual Storage Window (View and Create).

ssvsc0210

ssvsc0210: The specified virtual disk name already exists.

Explanation

Multiple virtual disks cannot be created with the same name.

User action

Check virtual disk names in the Virtual Storage Window (View and Create), and specify a virtual disk name not being used.

ssvsc0211

ssvsc0211: The physical disk is not registered into the specified virtual storage pool.

Explanation

The specified virtual storage pool does not have any physical disk.

User action

Check the virtual storage pool in the Virtual Storage Window (View and Create), and register a physical disk in the virtual storage pool.

ssvsc0212

ssvsc0212: The availabilities of a virtual storage pool or a physical disk are insufficient.

Explanation

A virtual disk with the specified capacity cannot be created because the virtual storage pool or physical disk is short of free space. Alternatively, migration could not be started because the empty capacity of the physical disk in copy destination virtual storage pool is smaller than the capacity of the copy source virtual disk.

User action

Check the size of unallocated space in the virtual storage pool or physical disk in the Virtual Storage Window (View and Create).

  • If a virtual disk is automatically created or capacity is added:

    • Register physical disks corresponding to the configuration conditions in the virtual storage pool.

    • Delete unnecessary virtual disks created in the specified virtual storage pool, which consist of physical disks corresponding to the configuration conditions.

  • If a virtual disk is selected and created or capacity is added by the user:

    • Select a physical disk with unallocated space.

    • Register the physical disk in the virtual storage pool.

    • Delete unnecessary virtual disks created in the specified virtual storage pool.

  • If a migration is started:

    • Check the empty capacity of the copy source virtual disk.

    • Register the physical disk in the virtual storage pool.

    • Delete unnecessary virtual disks created in the specified virtual storage pool.

ssvsc0213

ssvsc0213: The specified virtual disk does not exist.

Explanation

The virtual disk name is incorrect. Alternatively, the specified virtual disk doesn't exist.

User action

Check the name of the virtual disk being created on the Virtual Storage Window (View and Create).

ssvsc0214

ssvsc0214: The specified virtualization switch host name already exists.

Explanation

Multiple virtualization switches cannot be created with the same host name.

User action

Check the registered host names of virtualization switches in the Virtual Storage Window (Maintenance ). Alternatively, use the getvsw command to check the registered host names of virtualization switches.

ssvsc0215

ssvsc0215: Since a virtualization switch is in an equipment exchange state, this function cannot be performed. Virtualization switch host name = {0}

Explanation

The virtualization switch with %HostName is being replaced. Functions are restricted during switch replacement.

Parameters

0: Name of the virtualization switch in an exchange state

For virtualization switches other than the VS900 Model 200, the name of the virtualization switch is displayed as “virtualization switch name (host name)”.

User action

After the virtualization switch is replaced, perform registration of the virtualization switch on the ESC Resource Management Window. Then, refer to "6.2.3.3 Restoring the configuration information of a virtualization switch".

ssvsc0216

ssvsc0216: The memory is lack.

Explanation

The memory space is running low.

User action

Restart VSC Manager.

If the problem persists, refer to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

ssvsc0217

ssvsc0217: The specified virtual storage pool does not exist. The number of succeeded in deleting = {0}/{1}units

Explanation

An invalid virtual storage pool name was specified. Alternatively, the specified virtual disk doesn't exist.

Parameters

0: Number of units successfully deleted
1: Specified number of units

User action

Check the name of the virtual storage pool on the Virtual Storage Window (View and Create).

ssvsc0218

ssvsc0218: The specified physical disk does not exist. The number of succeeded in release = {0}/{1}units

Explanation

An invalid physical disk name was specified. Alternatively, the specified physical disk doesn't exist.

Parameters

0: Number of units successfully released
1: Specified number of units

User action

Check physical disk names in the Virtual Storage Window (View and Create).

ssvsc0219

ssvsc0219: The specified virtual enclosure does not exist. The number of succeeded in deleting = {0}/{1}units

Explanation

An invalid virtual enclosure name is specified, or the specified virtual enclosure name doesn't exist.

Parameters

0: Number of units successfully deleted
1: Specified number of units

User action

Check virtual enclosure names in the Virtual Storage Window (View and Create).

ssvsc0220

ssvsc0220: The specified virtual target does not exist. The number of succeeded in deleting = {0}/{1}units

Explanation

An invalid virtual target name was specified. Alternatively, the specified virtual target doesn't exist.

Parameters

0: Number of units successfully deleted
1: Specified number of units

User action

Check virtual target names in the Virtual Storage Window (View and Create).

ssvsc0221

ssvsc0221: The specified virtual disk does not exist. The number of succeeded in deleting = {0}/{1}units

Explanation

An invalid virtual disk name was specified. Alternatively, the specified virtual disk doesn't exist.

Parameters

0: Number of units successfully deleted
1: Specified number of units

User action

Check the names of created virtual disks in the Virtual Storage Window (View and Create).

ssvsc0222

ssvsc0222: Numbers for farm of an engine of a processing object are different.

Explanation

Different firmware versions of VSC Engine are being used in a redundant configuration.

User action

Set up a redundant configuration using virtualization switches with the same firmware versions. If the problem persists, referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, and contact your Fujitsu engineer (CE or SE).

ssvsc0223

ssvsc0223: Since a virtualization switch is in an equipment exchange state, failed to deletion. Host name = {0} The number of succeeded in making = {1}/{2}units

Explanation

The virtualization switch with %HostName is being replaced. Functions are restricted during switch replacement.

Parameters

0: Host name of the virtualization switch being replaced
For virtualization switches other than the VS900 Model 200, the name of the virtualization switch is displayed as “virtualization switch name (host name)”.
1: Number of units successfully deleted
2: Specified number of units

User action

After the virtualization switch is replaced perform registration on the ESC Resource Management Window. Then restore the configuration information; refer to "6.2.3.3 Restoring the configuration information of a virtualization switch".

ssvsc0224

ssvsc0224: Since a virtualization switch is in an equipment exchange state. Virtualization switch host name = {0}

Explanation

The virtualization switch with %HostName is being replaced. Functions are restricted during switch replacement.

Parameters

0: Host name of the virtualization switch being replaced

For virtualization switches other than the VS900 Model 200, the name of the virtualization switch is displayed as “virtualization switch name (host name)”.

User action

After the virtualization switch is replaced perform registration on the ESC Resource Management Window, and then restore the configuration information; refer to "6.2.3.3 Restoring the configuration information of a virtualization switch".

ssvsc0225

ssvsc0225: Failed to getting of real disk information.

Explanation

Physical disk information could not be obtained because an error occurred when storage unit information was being retrieved.

User action

Referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

ssvsc0226

ssvsc0226: Commit script cannot be performed. file = {0}

Explanation

The commit script start program was deleted.

Parameters

0: Path of the commit script start program file

User action

Referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

ssvsc0227

ssvsc0227: The number of virtual targets of SCSI command cues exceeds the limitation value of CA port. Real disk = {0} , Limitation value = {1} excess the number = {2}

Explanation

The number of SCSI command queues of virtual targets exceeds the limit value for a CA port.

Parameters

0: Physical disk information
1: Information regarding the number of queues
2: Number of excess queues

User action

Select a physical disk from another CA port.

ssvsc0228

ssvsc0228: The number of virtual targets of SCSI command cues exceeds the limitation value of CA port. Virtual disk = {0} , Real disk = {1} , Limitation value = {2} excess the number = {3}

Explanation

The number of SCSI command queues of virtual targets exceeds the limit value for a CA port.

Parameters

0: Virtual disk information
1: Physical disk information
2: Information regarding the number of queues
3: Number of excess queues

User action

Using a physical disk under another CA port, create a virtual disk again.

ssvsc0229

ssvsc0229: It failed in the excess of the number of SCSI command cues check processing of the virtual target. Code = {0}

Explanation

Processing to check whether the number of SCSI command queues of virtual targets exceeds the limit value has failed.

Parameters

0: VSC Engine error code

User action

Referring to "6.3 Collecting Data," collect the necessary data for troubleshooting, and then contact your Fujitsu engineer (CE or SE).

ssvsc0230

ssvsc0230: The specified virtualization switch name is already registered.

Explanation

A virtualization switch of the same name is not allowed to multi-register.

User action

Check virtualization switch names on the virtual storage window (maintenance) to set an unused virtualization switch name.

ssvsc0231

ssvsc0231: Since a virtualization switch is in an equipment exchange state, Failed to release. Host name = {0} The number of succeeded in release = {1}/{2}units

Explanation

The virtualization switch for %HostName is being replaced. While the device is being replaced, the functions are restricted.

Parameters

0: The host name of a virtualization switch that is being replaced
For virtualization switches other than the VS900 Model 200, the name of the virtualization switch is displayed as “virtualization switch name (host name)”.
1: Quantity that has succeeded in release
2: Specified quantity

User action

Since exchange virtualization switch, after the virtualization switch is replaced, execute "6.2.3.3 Restoring the configuration information of a virtualization switch" and perform registration on the ESC Resource Management Window.

ssvsc0232

ssvsc0232: Information was not able to be acquired from the principal switch.

Explanation

The necessary information could not be acquired from the principal switch.

User action

Check the following points:

  • Check whether there are any problems with the virtualization switches associated with the specified virtual storage pool or with the network environment for the FC switches in cascading connections to these virtualization switches.

  • Check whether the FC switches in cascading connections to the virtualization switches associated with the specified virtual storage pool have been registered.

ssvsc0233

ssvsc0233: Failed to getting virtualization switch. Host name = {0}

Explanation

A failure occurred in a virtualization switch, and the information acquisition failed.

Parameters

0: Virtualization switch host name

For virtualization switches other than the VS900 Model 200, the name of the virtualization switch is displayed as “virtualization switch name (host name)”.

User action

Refer to "6.3 Collecting Data" to collect required data for troubleshooting and contact the Fujitsu engineer (CE/SE).

ssvsc0234

ssvsc0234: Since a virtualization switch is in an equipment exchange state, Failed to process. Host name = {0} The number of succeeded in processing = {1}/{2}units

Explanation

The virtualization switch (%HostName) is being replaced. During device replacement, functions will be limited.

Parameters

0: Name of the host of the virtualization switch being replaced
For virtualization switches other than the VS900 Model 200, the name of the virtualization switch is displayed as “virtualization switch name (host name)”.
1: Number of units successfully processed
2: Number of units specified

User action

After the virtualization switch is replaced perform registration on the Physical Device Replacement Window. Refer to "6.2.3.3 Restoring the configuration information of a virtualization switch".

ssvsc0235

ssvsc0235: The virtualization switch has been registered with the VSC Manager. Host name = {0}

Explanation

The virtualization switch has been registered with the VSC Manager.

Parameters

0: Virtualization switch name (host name)

User action

None

ssvsc0236

ssvsc0236: Virtualization function has been started.

Explanation

A virtualization switch has either been registered successfully or the virtualization switch function has started successfully.

User action

None

ssvsc0237

ssvsc0237: Failed to starting virtualization function.

Explanation

A virtualization switch has failed to be registered or the virtualization switch function has failed to start.

User action

Take the action appropriate for the error messages that are displayed after this message.

ssvsc0238

ssvsc0238: Virtualization function has been stopped.

Explanation

The virtualization switch function has stopped successfully.

User action

None

ssvsc0239

ssvsc0239: Failed to stopping virtualization function.

Explanation

Stopping the virtualization switch function has failed.

User action

Take the action appropriate for the error messages that are displayed after this message.

ssvsc0240

ssvsc0240: The virtualization switch has been deleted from the VSC Manager. Host name = {0}

Explanation

The virtualization switch has been deleted from the VSC Manager.

Parameters

0: Virtualization switch name (host name)

User action

None

ssvsc0241

ssvsc0241: The specified Disk has virtual disks.

Explanation

There is a virtual disk for the specified physical disk.

User action

Use the Virtual Storage window (View and Create) to check that no virtual disks have been created for the specified physical disk.

ssvsc0300

ssvsc0300: The maximum number of creating virtual storage pools was exceeded.

Explanation

No more virtual storage pools can be created.

User action

Delete unnecessary virtual storage pools and try again.
For the number of virtual storage pools that can be created, refer to "Appendix D Limit Values."

ssvsc0301

ssvsc0301: The physical disk is registered into the specified virtual storage pool.

Explanation

A virtual storage pool in which a physical disk is registered cannot be deleted.

User action

Confirm that the specified name of the virtual storage pool is correct.

In the Virtual Storage Window (View and Create), check for a physical disk in the virtual storage pool to be deleted.

If the virtual storage pool contains a physical disk, release the physical disk from the virtual storage pool before executing the command.

ssvsc0302

ssvsc0302: The specified physical disk name already exists.

Explanation

An attempt was made to register a physical disk that has already been registered.

User action

Verify the WWN and LUN in the Virtual Storage Window (View and Create), and execute the command again.

ssvsc0303

ssvsc0303: The maximum number of registering physical disks was exceeded.

Explanation

No more physical disks can be registered.

User action

Release unnecessary physical disks, and execute the command again.

For the number of physical disks that can be registered, refer to "Appendix D Limit Values".

ssvsc0304

ssvsc0304: The specified physical disk does not exist. Code = {0}

Explanation

VSC Engine could not find the specified physical disk.

Parameters

0: VSC Engine error code

User action

Check the storage unit management window or the Design Sheet specifications to verify the WWN and LUN to be registered. In the related management windows, confirm that all the physical disks that constitute virtual disks are connected to virtualization switches.

ssvsc0305

ssvsc0305: There is no response from the specified real disk. Code = {0}

Explanation

The specified physical disk did not respond.

Parameters

0: VSC Engine error code

User action

Check the power supply and connection cable of the disk unit.

Alternatively check the following settings of the disk unit; host worldwide name, host affinity and virtualization switch zoning.

For details, refer to "3.4.1.1 Using the zoning function of a virtualization switch" and "3.4.1.2 Using the host table settings mode of ETERNUS and GR".

If the problem persists, collect the necessary data for troubleshooting and contact your Fujitsu engineer (CE or SE).

ssvsc0306

ssvsc0306: The specified physical disk is disk equipment of the outside for support. Code = {0}

Explanation

The specified physical disk is a non-supported disk unit or not a disk unit at all.

Parameters

0: VSC Engine error code

User action

Use supported hardware for operation.

For details, refer to "1.4.1 Supported hardware".

ssvsc0307

ssvsc0307: Failed to Registration of a physical disk. Code = {0}

Explanation

Physical disk registration failed because an error occurred in a virtualization switch.

Parameters

0: VSC Engine error code

User action

Referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

ssvsc0308

ssvsc0308: The specified physical disk is assigned to the real space of a virtual disk.

Explanation

The specified physical disk is allocated to the real space of a virtual disk.

User action

Delete the allocated virtual disk and then execute the command again.

ssvsc0309

ssvsc0309: The physical disk specified in the specified virtual storage pool does not exist.

Explanation

The specified physical disk is registered in another virtual storage pool.

User action

Verify the relationship between the virtual storage pool and physical disk, which is registered in the virtual storage pool, in the Virtual Storage Window (View and Create), and execute the command again.

ssvsc0310

ssvsc0310: The maximum number of creating virtual enclosures was exceeded.

Explanation

No more virtual enclosures can be created.

User action

Delete unnecessary virtual enclosures, and execute the command again.

For the number of virtual enclosures that can be created, refer to "Appendix D Limit Values".

ssvsc0311

ssvsc0311: The specified BOX-ID already exists.

Explanation

An attempt was made to create a virtual enclosure with a BOX-ID that was already created.

User action

Verify the box_id for the virtual enclosure in the Virtual Storage Window (View and Create).

ssvsc0312

ssvsc0312: The virtual target is created to the specified virtual enclosure.

Explanation

A virtual enclosure in which a virtual target is registered cannot be deleted.

User action

Confirm that the specified virtual enclosure name is correct.

In the Virtual Storage Window (View and Create), check for a virtual target in the virtual enclosure to be deleted.

If the virtual enclosure contains a virtual target, delete the virtual target from the virtual enclosure before executing the command.

ssvsc0313

ssvsc0313: The specified enclosure or the specified virtualization switch is a mistake.

Explanation

A virtual target cannot be created because the relationship between the virtualization switch and the virtual enclosure is invalid.

User action

Verify the relationship between the registered virtualization switch and the virtual enclosure in the Virtual Storage Window (View and Create), and execute the command again.

ssvsc0314

ssvsc0314: The maximum number of creating virtual targets was exceeded in the specified virtual enclosure. Code = {0}

Explanation

No more virtual targets can be created in the same virtual enclosure.

Parameters

0: VSC Engine error code

User action

Delete unnecessary virtual targets, and execute the command again.

For the number of virtual targets that can be created in the same virtual enclosure, refer to "Appendix D Limit Values".

ssvsc0315

ssvsc0315: The maximum number of creating virtual targets was exceeded in the specified virtualization switch. Code = {0}

Explanation

No more virtual targets can be created in the virtualization switch.

Parameters

0: VSC Engine error code

User action

Delete unnecessary virtual targets, and execute the command again.

For the number of virtual targets that can be created in a virtualization switch, refer to "Appendix D Limit Values".

ssvsc0316

ssvsc0316: Failed to creation of a virtual target. Code = {0}

Explanation

A virtual target could not be created because an error occurred in a virtualization switch.

Parameters

0: VSC Engine error code

User action

Referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

ssvsc0317

ssvsc0317: The virtual disk is assigned to the specified virtual target.

Explanation

The virtual target to which a virtual disk is assigned cannot be deleted.

User action

Unassign the virtual disk from the virtual target, and delete the virtual target.

ssvsc0318

ssvsc0318: Failed to deletion of a virtual target. Code = {0}

Explanation

A virtual target could not be deleted because an error occurred in a virtualization switch.

Parameters

0: VSC Engine error code

User action

Referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

ssvsc0319

ssvsc0319: The specified virtual target is invalid.

Explanation

A virtual disk cannot be allocated to the specified virtual target because the virtualization switch that controls the corresponding virtual storage pool does not have the virtual target.

User action

Check the Virtual Storage Window (View and Create) and ensure that the virtual disk is specified for the corresponding storage pool on the virtualization switch.

ssvsc0320

ssvsc0320: The virtual target in a different virtual enclosure was specified.

Explanation

The specified virtual target belongs to a different virtual enclosure.

User action

Check the virtual target name in the Virtual Storage Window (View and Create). Specify a virtual target that belongs to the same virtual enclosure.

ssvsc0322

ssvsc0322: The maximum number of creating extents of physical disk that constituted a virtual disk was exceeded.

Explanation

An attempt was made to create an extent that constitutes a virtual disk that exceeds the maximum number of extents that can be created.

User action

Take either of the following procedures on the Virtual Storage Window (View and Create) screen.

  • If a virtual disk is automatically created or capacity is added:

    • Register physical disks corresponding to the configuration conditions in the virtual storage pool.

    • Specify another virtual storage pool.

  • If a virtual disk is selected and created or capacity is added by the user:

    • Refer to "A.2.3 Displaying the virtual storage pool" to check the number of unallocated extents of the "View and Create" screen and specify physical disks so that the number of extents may not exceed the maximum permissible number. For details, refer to "Appendix D Limit Values".

    • Execute "Candidate Selection".

    • Register physical disks in the virtual storage pool.

If capacity is added, there are cases where the number of extents has already reached the maximum permissible number.
In this case, use Migration to expand the capacity.

ssvsc0324

ssvsc0324: The maximum number of creating virtual disks was exceeded in the specified virtualization switch. Code = {0}

Explanation

No more virtual disks can be created in the virtualization switch.

Parameters

0: VSC Engine error code

User action

Delete unnecessary virtual disks, and execute the command again.

For the number of virtual disks that can be created in a virtualization switch, refer to "Appendix D Limit Values".

ssvsc0325

ssvsc0325: Failed to creation of a virtual disk. Code = {0}

Explanation

A virtual disk could not be created because an error occurred in a virtualization switch.

Parameters

0: VSC Engine error code

User action

Referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

ssvsc0326

ssvsc0326: The specified virtual disk is now copying. Code = {0}

Explanation

You cannot manipulate a virtual disk that is being copied.

Parameters

0: VSC Engine error code

User action

Check the copy status in the Virtual Storage Window (Copy). Alternatively, use the getsession command to check the copy status.

ssvsc0327

ssvsc0327: Failed to deletion of a virtual disk. Code = {0}

Explanation

A virtual disk could not be deleted because an error occurred in a virtualization switch.

Parameters

0: VSC Engine error code

User action

Referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

ssvsc0328

ssvsc0328: The specified host quota number already exists.

Explanation

Each host allocation number in the same virtual target must be unique.

User action

Check the host allocation numbers of virtual disks in the Virtual Storage Window (View and Create).

Specify a host allocation number that is unique within the virtual target.

ssvsc0329

ssvsc0329: The number of host quota numbers which can be created on the virtual targets is over the maximum number which can be created. Code = {0}

Explanation

No more host allocation numbers can be created in the same virtual target.

Parameters

0: VSC Engine error code

User action

Delete unnecessary host allocation numbers, and execute the command again.

For the number of host allocation numbers that can be created in a virtual target, refer to "Appendix D Limit Values".

ssvsc0330

ssvsc0330: Failed to setting of a host quota number. Code = {0}

Explanation

A host allocation number could not be set because an error occurred in a virtualization switch.

Parameters

0: VSC Engine error code

User action

Referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

ssvsc0331

ssvsc0331: The I/O error occurred when it accessed a physical disk. Code = {0}

Explanation

An error was detected during access to the physical disk from the virtualization switch.

Parameters

0: VSC Engine error code

User action

Execute the command again.
If the problem persists, refer to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

ssvsc0332

ssvsc0332: It is in the state which cannot use a virtual disk. Code = {0}

Explanation

An error occurred in the virtualization switch.

Parameters

0: VSC Engine error code

User action

Check the disk unit status and execute the command again.
If the problem persists, refer to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

ssvsc0333

ssvsc0333: A physical disk cannot be registered in WWN and host-lun which were specified.

Explanation

The access path from the specified physical disk to the virtual storage pool is incorrect. Alternatively, the number of virtualization switches managed by the specified virtual storage pool and the number of paths for the physical disks do not match.

User action

Check the storage unit management window or the Design Sheet specifications to verify the WWN and LUN to be registered. Confirm that all the physical disks constituting the virtual disk are connected to the virtualization switches on the Relationship Management Window. Ensure that the physical disk can be seen from all the virtualization switches controlled by the specified virtual storage pool. Ensure that there is only one access path to a physical disk from each virtualization switch.

ssvsc0334

ssvsc0334: Physical disk does not exist in the specified composition conditions.

Explanation

There is no physical disk that meets the specified configuration conditions.

User action

Refresh the Virtual Storage Window (View and Create) and enter the configuration conditions again.

ssvsc0335

ssvsc0335: Failed to capacity addition of a virtual disk. Code = {0}

Explanation

Failed to add capacity to a virtual disk because an error occurred in the virtualization switch.

Parameters

0: VSC Engine error code

User action

Referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

ssvsc0336

ssvsc0336: The specified physical disk cannot carry out capacity addition of a virtual disk.

Explanation

The specified physical disk is registered in a different virtual storage pool from the physical disk that constitutes the virtual disk.

User action

Specify a physical disk registered in the same virtual storage pool.

ssvsc0337

ssvsc0337: The specified virtual disk is assigned to the virtual target.

Explanation

You cannot delete the specified virtual disk because it is allocated to the virtual target.

User action

Unassign the virtual disk before deleting it.

ssvsc0338

ssvsc0338: The specified physical disk does not exist. LogicalVolume = {0}

Explanation

The information of the physical resources under management may be outdated.

Parameters

0: Physical disk information

User action

Refresh the physical resources management status to the latest one and register the physical disk again.

ssvsc0339

ssvsc0339: The specified virtual disk cannot be accessed from the virtualization switch group of the specified virtual target.

Explanation

The same virtualization switch group must control the virtual target and virtual disk.

User action

In the Virtual Storage Window (View and Create), check the virtualization switch of the virtual enclosure to which the virtual target belongs, and check the virtualization switch of the virtual storage pool containing the virtual disk. Specify a virtual target and virtual disk in the same virtualization switch.

ssvsc0340

ssvsc0340: The specified virtual disk in the process of migration or backup already exists. Virtual disk = {0}

Explanation

Either the specified virtual disk is in the process of migration or there is a migration backup.

Parameters

0: Virtual disk name

User action

In the Virtual Storage Window (Copy), confirm that the specified virtual disk is not in the process of migration or that there is no migration backup. Cancel migration or delete the backup, then execute the command again.

ssvsc0341

ssvsc0341: The host quota number of the specified virtual disk is intermingled. Virtual disk = {0}

Explanation

The virtual disk can be allocated with only one host allocation number.

Parameters

0: Virtual disk name

User action

In the Virtual Storage Window (View and Create), check the host allocation number of virtual disks and allocate the virtual disk with the same host allocation number.

ssvsc0342

ssvsc0342: The virtual target in a different virtual enclosure was specified. Virtual disk = {0}

Explanation

A different virtual enclosure has the specified virtual target.

Parameters

0: Virtual disk name

User action

In the Virtual Storage Window (View and Create), check the virtual target name.

Specify a virtual target included in the same virtual enclosure.

ssvsc0343

ssvsc0343: The specified virtual disk is now copying. Virtual disk = {0} Code = {1}

Explanation

You cannot manipulate a virtual disk that is being copied.

Parameters

0: Virtual disk name
1: VSC Engine error code

User action

In the Virtual Storage Window (Copy), check the copying status.

ssvsc0344

ssvsc0344: It is in the state which cannot use a virtual disk. Virtual disk = {0} Code = {1}

Explanation

An error occurred in the virtualization switch.

Parameters

0: Virtual disk name
1: VSC Engine error code

User action

Check the disk unit status and repeat this operation.

If the problem persists, refer to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

ssvsc0345

ssvsc0345: Failed to assignment of a virtual disk. Code = {0}

Explanation

A virtual disk could not be allocated because an error occurred in a virtualization switch.

Parameters

0: VSC Engine error code

User action

Referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

ssvsc0346

ssvsc0346: Failed to creation of a virtual enclosure. Code = {0}

Explanation

A virtual enclosure could not be created because an error occurred in a virtualization switch.

Parameters

0: VSC Engine error code

User action

Referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

ssvsc0347

ssvsc0347: The I/O error occurred when it accessed a physical disk. LogicalVolume = {0}. Code = {1}

Explanation

An error was detected during access from the virtualization switch to the physical disk.

Parameters

0: Physical disk information
1: VSC Engine error code

User action

Submit the request again.

If the problem persists, refer to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

ssvsc0348

ssvsc0348: The specified physical disk is disk equipment of the outside for support. LogicalVolume = {0}. Code = {1}

Explanation

The specified physical disk is a non-supported disk unit or not a disk unit at all.

Parameters

0: Physical disk information
1: VSC Engine error code

User action

Use supported hardware for operation. For details, refer to "1.4.1 Supported hardware".

ssvsc0349

ssvsc0349: The specified physical disk is in a busy state. LogicalVolume = {0}.

Explanation

The specified physical disk returned a busy status.

Parameters

0: Physical disk information

User action

Submit the request again.

ssvsc0350

ssvsc0350: The specified host quota number already exists. Virtual disk = {0}

Explanation

No more host allocation numbers can be created in the same virtual target.

Parameters

0: Virtual disk name

User action

In the Virtual Storage Window (View and Create), check the host allocation number of the virtual disk.

ssvsc0351

ssvsc0351: The specified physical disk already exists. LogicalVolume = {0}

Explanation

An attempt was made to register a physical disk that has already been registered.

Parameters

0: Physical disk information

User action

Refresh the Virtual Storage Window (View and Create), verify the WWN and LUN, and execute the command again.

ssvsc0352

ssvsc0352: A physical disk cannot be registered in WWN and host-lun which were specified. LogicalVolume = {0}

Explanation

The access path from the specified physical disk to the virtual storage pool is incorrect.

Or the number of virtualization switches managed by the specified virtual storage pool is not consistent with that of physical disk paths.

Parameters

0: Physical disk information

User action

Check the WWN and LUN of a physical disk to be registered on the management window of the storage device or on the specifications in design sheet.
Check on the related management window if the physical disks making up a virtual disk are connected to all the virtualization switches.
Set up so that the physical disks can be seen from all the virtualization switches managed by the specified virtual storage pool.
In addition, the number of access paths to the physical disks from each virtualization switch should be one.

ssvsc0353

ssvsc0353: The specified physical disk does not exist. LogicalVolume = {0} Code = {1}

Explanation

The specified physical disk could not be found from VSC Engine.

Parameters

0: Physical disk information
1: VSC Engine error code

User action

Check the storage unit management window or the Design Sheet specifications to verify the WWN and LUN to be registered.

In the related management windows, confirm that all the physical disks that constitutes the virtual disk are connected to virtualization switches.

ssvsc0354

ssvsc0354: The specified physical disk is assigned to the real space of a virtual disk. LogicalVolume = {0}

Explanation

The specified physical disk is allocated to the real space of a virtual disk.

Parameters

0: Physical disk information

User action

In the Virtual Storage Window (View and Create), check the virtual disk allocated to the real space.

ssvsc0355

ssvsc0355: The most suitable real disk that constituted a virtual disk, was not be elected in consideration of an associated CM.

Explanation

The virtual disk that is most suitable considering the associated CM cannot be selected from the specified virtual storage pool.

User action

Perform one of the following actions in the Virtual Storage Window (View and Create):

  • To create a virtual disk in the specified virtual storage pool or add the capacity, do not use the <Candidate Selection> and <Automatic creation> button but directly select the physical disk.

  • Add physical disks corresponding to the configuration conditions to the specified virtual storage pool.

  • Specify another virtual storage pool.

ssvsc0356

ssvsc0356: The maximum number of creating virtual disks was exceeded in the specified virtualization switch.

Explanation

No more virtual disks can be created in the virtualization switch.

User action

Delete unnecessary virtual disks, and execute the command again.

For the number of virtual disks that can be created in a virtualization switch, refer to "Appendix D Limit Values".

ssvsc0357

ssvsc0357: The maximum number of creating extents of physical disk that constituted a virtual disk was exceeded. The number of succeeded in making = {0}/{1}units.

Explanation

The maximum number of extents that can be created for the physical disks constituting a virtual disk has been exceeded.

Parameters

0: Number of units successfully created
1: Specified number of units

User action

Take either of the following procedures on the Virtual Storage Window (View and Create) screen.

  • If a virtual disk is automatically created or capacity is added:

    • Register physical disks corresponding to the configuration conditions in the virtual storage pool.

    • Specify another virtual storage pool.

  • If a virtual disk is selected and created or capacity is added by the user:

    • Refer to "A.2.3 Displaying the virtual storage pool" to check the number of unallocated extents of the "View and Create" screen and specify physical disks so that the number of extents may not exceed the maximum permissible number. For details, refer to "Appendix D Limit Values".

    • Execute "Candidate Selection".

    • Register physical disks in the virtual storage pool.

If capacity is added, there are cases where the number of extents has already reached the maximum permissible number. In this case, use Migration to expand the capacity.

ssvsc0358

ssvsc0358: The most suitable real disk that constituted a virtual disk, was not be elected in consideration of an associated CM. The number of succeeded in making = {0}/{1}units

Explanation

The virtual disk that is most suitable considering the associated CM cannot be selected from the specified virtual storage pool.

Parameters

0: Number of units successfully created
1: Specified number of units

User action

Perform one of the following actions in the Virtual Storage Window (View and Create):

  • To create a virtual disk in the specified virtual storage pool or add the capacity, do not use the <Candidate Selection> and <Automatic creation> button but directly select the physical disk.

  • Add physical disks corresponding to the configuration conditions to the specified virtual storage pool.

  • Specify another virtual storage pool.

ssvsc0359

ssvsc0359: It is in the state which cannot use a virtual disk. Code = {0} The number of succeeded in making = {1}/{2}units

Explanation

An error was detected during access from the virtualization switch to the physical disk.

Parameters

1: Number of units successfully created
2: Specified number of units

User action

Execute the command again.

If the problem persists, refer to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

ssvsc0360

ssvsc0360: There is no response from the specified real disk. Code = {0} The number of succeeded in making = {1}/{2}units

Explanation

No response was issued from the selected physical disk.

Parameters

0: VSC Engine error code
1: Number of units successfully created
2: Specified number of units

User action

Execute the command again.

If the problem persists, refer to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

ssvsc0361

ssvsc0361: Failed to creation of a virtual disk. Code = {0} The number of succeeded in making = {1}/{2}units

Explanation

A virtual disk could not be created because an error occurred in a virtualization switch.

Parameters

0: VSC Engine error code
1: Number of units successfully created
2: Specified number of units

User action

Referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

ssvsc0362

ssvsc0362: It is in the state which cannot use a virtual disk. Code = {0} The number of succeeded in making = {1}/{2}units

Explanation

An error occurred in the virtualization switch.

Parameters

0: VSC Engine error code
1: Number of units successfully created
2: Specified number of units

User action

Check the state of the disk unit and reenter the command.

If the problem persists, refer to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

ssvsc0363

ssvsc0363: The physical disk is registered into the specified virtual storage pool. The number of succeeded in deleting = {0}/{1}units

Explanation

A virtual storage pool in which a physical disk is registered cannot be deleted.

Parameters

0: Number of units successfully deleted
1: Specified number of units

User action

In the Virtual Storage Window (View and Create), check for a physical disk in the virtual storage pool that is to be deleted.

If the virtual storage pool contains a physical disk, release the physical disk from the virtual storage pool before executing the command.

ssvsc0364

ssvsc0364: The specified physical disk is assigned to the real space of a virtual disk. The number of succeeded in release = {0}/{1}units

Explanation

The specified physical disk has already been allocated to the real space of a virtual disk.

Parameters

0: Number of units successfully released
1: Specified number of units

User action

Refresh the Virtual Storage Window (View and Create), select an unallocated physical disk, and execute the command again.

ssvsc0365

ssvsc0365: The virtual target is created to the specified virtual enclosure. The number of succeeded in deleting = {0}/{1}units

Explanation

A virtual enclosure in which a virtual target is registered cannot be deleted.

Parameters

0: Number of units successfully deleted
1: Specified number of units

User action

In the Virtual Storage Window (View and Create), check for a virtual target in the virtual enclosure that is to be deleted.

If the virtual enclosure contains a virtual target, delete the virtual target from the virtual enclosure before executing the command.

ssvsc0366

ssvsc0366: The virtual disk is assigned to the specified virtual target. The number of succeeded in deleting = {0}/{1}units

Explanation

A virtual target to which a virtual disk has been allocated cannot be deleted.

Parameters

0: Number of units successfully deleted
1: Specified number of units

User action

Unassign the virtual disk before deleting the virtual target.

ssvsc0367

ssvsc0367: Failed to deletion of a virtual target. Code = {0} The number of succeeded in deleting = {1}/{2}units

Explanation

A virtual target could not be deleted because an error occurred in a virtualization switch.

Parameters

0: VSC Engine error code
1: Number of units successfully deleted
2: Specified number of units

User action

Referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

ssvsc0368

ssvsc0368: The specified virtual disk is now copying. Code = {0} The number of succeeded in deleting = {1}/{2}units

Explanation

You cannot operate a virtual disk that is subject to a copy operation.

Parameters

0: VSC Engine error code
1: Number of units successfully deleted
2: Specified number of units

User action

Check the copy status in the Virtual Storage Window (Copy). Alternatively, use the getsession command to check the copy status.

ssvsc0369

ssvsc0369: Failed to deletion of a virtual disk. Code = {0} The number of succeeded in deleting = {1}/{2}units

Explanation

An error occurred in the virtualization switch.

Parameters

0: VSC Engine error code
1: Number of units successfully deleted
2: Specified number of units

User action

Referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

ssvsc0370

ssvsc0370: The specified virtual disk is assigned to the virtual target. The number of succeeded in deleting = {0}/{1}units

Explanation

The specified virtual disk cannot be deleted because it is allocated to a virtual target.

Parameters

0: Number of units successfully deleted
1: Specified number of units

User action

Unassign the virtual disk before deleting it.

ssvsc0371

ssvsc0371: It is in the state which cannot use a virtual disk. Code = {0} The number of succeeded in deleting = {1}/{2}units

Explanation

An error occurred in the virtualization switch.

Parameters

0: VSC Engine error code
1: Number of units successfully deleted
2: Specified number of units

User action

Check the state of the disk unit and reenter the command.

If the problem persists, refer to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

ssvsc0372

ssvsc0372: The I/O error occurred when it accessed a physical disk. Code = {0} LogicalVolume = {1} The number of succeeded in making = {2}/{3}units

Explanation

An error was detected during access to the physical disk from the virtualization switch.

Parameters

0: VSC Engine error code
1: Physical disk information
2: Number of units successfully created
3: Specified number of units

User action

Execute the command again.

If the problem persists, refer to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

ssvsc0373

ssvsc0373: The specified physical disk is disk equipment of the outside for support. Code = {0} LogicalVolume = {1} The number of succeeded in making = {2}/{3}units

Explanation

The specified physical disk is an unsupported disk unit or it is not a disk unit.

Parameters

0: VSC Engine error code
1: Physical disk information
2: Number of units successfully created
3: Specified number of units

User action

Use supported hardware for operation. For details, refer to "1.4.1 Supported hardware".

ssvsc0374

ssvsc0374: It is in the state which cannot use a virtual disk. Code = {0} LogicalVolume = {1} The number of succeeded in making = {2}/{3}units

Explanation

An error occurred in the virtualization switch.

Parameters

0: VSC Engine error code
1: Physical disk information
2: Number of units successfully created
3: Specified number of units

User action

Confirm that the status of the disk unit is normal, then execute the command again.

If the problem persists, refer to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

ssvsc0375

ssvsc0375: Failed to batch conversion. Code = {0} LogicalVolume = {1} The number of succeeded in making = {2}/{3}units

Explanation

Batch conversion failed because an error occurred in a virtualization switch.

Parameters

0: VSC Engine error code
1: Physical disk information
2: Number of units successfully created
3: Specified number of units

User action

Referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

ssvsc0376

ssvsc0376: The maximum number of creating virtual targets was exceeded in the specified virtual enclosure.

Explanation

No more virtual targets can be created in the same virtual enclosure.

User action

Delete unnecessary virtual targets, and execute the command again. For the number of virtual targets that can be created in a virtualization switch, refer to "Appendix D Limit Values".

ssvsc0377

ssvsc0377: The maximum number of creating virtual targets was exceeded in the specified virtualization switch.

Explanation

No more virtual targets can be created in the virtualization switch.

User action

Delete unnecessary virtual targets, then execute the command again. For the number of virtual targets that can be created in a virtualization switch, refer to "Appendix D Limit Values".

ssvsc0378

ssvsc0378: The number of host quota numbers which can be created on the virtual targets is over the maximum number which can be created.

Explanation

No more host allocation numbers can be created in the same target.

User action

Delete unnecessary host allocation numbers, then execute the command again. For the number of host allocation numbers that can be created in a virtualization switch, refer to "Appendix D Limit Values".

ssvsc0379

ssvsc0379: The specified host quota number already exists.

Explanation

Each host allocation number in the same virtual target must be unique.

User action

Check the host allocation numbers of virtual disks in the Virtual Storage Window (View and Create). Specify a host allocation number that is unique within the virtual target.

ssvsc0380

ssvsc0380: A physical disk cannot be registered in WWN and host-lun which were specified. LogicalVolume = {0} The number of succeeded in making = {1}/{2}units

Explanation

The access path from the specified physical disk to the virtual storage pool is incorrect.

Alternatively, the number of virtualization switches managed by the specified virtual storage pool does not match the number of paths for the physical disks.

Parameters

0: Physical disk information
1: Number of units successfully created
2: Specified number of units

User action

Check the storage unit management window or the Design Sheet specifications to verify the WWN and LUN of the physical disk to be registered.

Confirm that all the physical disks constituting the virtual disk are connected to the virtualization switches on the Relationship Management Window. Ensure that the physical disk can be seen from all the virtualization switches controlled by the specified virtual storage pool. Ensure that there is only one access path to a physical disk from individual virtualization switch.

ssvsc0381

ssvsc0381: The specified physical disk does not exist. Code = {0} LogicalVolume = {1} The number of succeeded in making = {2}/{3}units

Explanation

The specified physical disk could not be found from VSC Engine.

Parameters

0: VSC Engine error code
1: Physical disk information
2: Number of units successfully created
3: Specified number of units

User action

Check the storage unit management window or the Design Sheet specifications to verify the WWN and LUN to be registered.

In the related management windows, confirm that the physical disk is connected to all virtualization switches associated with the virtual storage used.

ssvsc0382

ssvsc0382: The specified physical disk does not exist. LogicalVolume = {0} The number of succeeded in making = {1}/{2}units

Explanation

Information on the physical resources under management is probably out of date.

Parameters

0: Physical disk information
1: Number of units successfully created
2: Specified number of units

User action

Update the physical resource management status, then register the physical disk again.

ssvsc0383

ssvsc0383: The specified physical disk already exists. LogicalVolume = {0} The number of succeeded in making = {1}/{2}units

Explanation

An attempt was made to register an already registered physical disk.

Parameters

0: Name of the physical disk that could not be registered
1: Number of units successfully created
2: Specified number of units

User action

Verify the WWN and LUN in the Virtual Storage Window (View and Create).

ssvsc0384

ssvsc0384: Neither the device name nor the LUNV number of the input parameter are used.

Explanation

Although the physical disk is registered in the virtual storage pool, the values stored in VSC Manager are used as the name of storage unit and the LUNV number. The specified name of storage unit and LUNV number are not used.

User action

Confirm that the physical disk is not Fujitsu’s.

ssvsc0385

ssvsc0385: The physical disk is not registered into the CA Port.

Explanation

A VS900 management area could not be created because no physical disk connected to the specified CA port had been registered.

User action

Register a physical disk connected to the specified CA port.

ssvsc0386

ssvsc0386: The VS900 management area in the specified CA port has been made.

Explanation

Creating a VS900 management area failed because there is already an existing VS900 management area for the specified CA port.

User action

In the "List of VS900 Management Areas" window, confirm that the VS900 management area of the specified CA port already exists.

ssvsc0387

ssvsc0387: As for a real disk in the specified CA port, empty capacity necessary for the VS900 management area is insufficient.

Explanation

A VS900 management area could not be created because the physical disk connected to the specified CA port does not have sufficient free space to accommodate the VS900 management area.

User action

Perform one of the following operations in the Virtual Storage Window (View and Create) until sufficient free space for the VS900 management area can be secured:

  • Increase the size of the physical disk connected to the specified CA port.

  • Delete a virtual disk to which the physical disk connected to the specified CA port is allocated.

ssvsc0388

ssvsc0388: Failed to creation of a VS900 management area. Code = {0}

Explanation

A VS900 management area could not be created because an error occurred in a virtualization switch.

Parameters

0: VSC Engine error code

User action

Referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

ssvsc0389

ssvsc0389: The VS900 management area does not exist in the specified CA port.

Explanation

Deleting the VS900 management area of the specified CA port failed because it was not found.

User action

In the "List of VS900 Management Areas" window, confirm that the VS900 management area of the specified CA port does not exist.

ssvsc0390

ssvsc0390: The session that uses the VS900 management area in the specified CA port exists. SessionID = {0}

Explanation

The VS900 management area of the specified CA port could not be deleted because the session using the VS900 management area cannot be reallocated to another VS900 management area.

Parameters

0: ID of the session in use

If multiple sessions are in use, they are all displayed delimited by a comma ",".

User action

Terminate the target session(s), then execute the command again.

ssvsc0391

ssvsc0391: The session that uses the VS900 management area in the specified CA port cannot be allocated in another VS900 management area. SessionID = {0}

Explanation

An attempt was made to relocate the session using the VS900 management area of the specified CA port to another VS900 management area, but no alternative VS900 management area was found. Therefore, the VS900 management area could not be deleted.

Parameters

0: ID of the session in use

If multiple sessions are in use, they are all displayed delimited by a comma ",".

User action

Create another VS900 management area in the same switch group as that of the specified VS900 management area, then execute the command again.

If no other VS900 management area can be created, terminate the target session(s), then execute the command again.

ssvsc0392

ssvsc0392: The session that uses the VS900 management area in the specified CA port exists. Reallocatable SessionID = {0} Not Reallocatable SessionID = {1}

Explanation

An attempt was made to relocate the session using the VS900 management area of the specified CA port to another VS900 management area, but the attempt failed. Therefore, the VS900 management area could not be deleted.

Parameters

0: ID of a relocatable session. If multiple sessions are in use, they are all displayed delimited by a comma ",".
1: ID of a non-relocatable session. If multiple sessions are in use, they are all displayed delimited by a comma ",".

User action

Perform one of the following operations, and execute the command again:

  • Terminate the non-relocatable session(s).

  • Create another VS900 management area in the same switch group as that of the specified VS900 management area.

If no other VS900 management area can be created, terminate the relocatable session(s).

ssvsc0393

ssvsc0393: Failed to deletion of a VS900 management area. Code = {0}

Explanation

The VS900 management area could not be deleted because an error occurred in a virtualization switch.

Parameters

0: VSC Engine error code

User action

Referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

ssvsc0394

ssvsc0394: The specified physical disk is assigned to the VS900 management area. LogicalVolume = {0}

Explanation

The specified physical disk could not be released because it had been allocated to a VS900 management area.

Parameters

0: Physical disk information

User action

Delete the VS900 management area to which the disk is allocated, then execute the command again.

ssvsc0395

ssvsc0395: The specified physical disk is assigned to the VS900 management area. The number of succeeded in release = {0}/{1}units

Explanation

The specified physical disk could not be released because it had been allocated to a VS900 management area.

Parameters

0: Number of units successfully released
1: Specified number of units

User action

Delete the VS900 management area to which the disk is allocated, then execute the command again.

ssvsc0399

ssvsc0399: The specified physical disk is off the subject of the support.

Explanation

The specified physical disk is excluded from support. Therefore, it cannot be registered.

User action

Check the following information on a physical disk in which an error occurred.

  • Check if the physical disk capacity exceeds the maximum value defined in VSC Engine.

After correcting the above mentioned matter, update the management status of the physical resource to the latest status and then re-register the physical disk.

ssvsc0400

ssvsc0400: Backup has already existed in the specified virtual disk.

Explanation

A virtual disk having a backup cannot be migrated.

User action

Delete the backup disk in the Virtual Storage Window (Copy), then execute migration processing again.

ssvsc0401

ssvsc0401: The specified sessionID does not exist.

Explanation

The specified session has already ended.
Otherwise, the specified session ID is incorrect.

User action

Confirm that the target session ID exists in the Virtual Storage Window (Copy).

Use the getsession command to check the session ID.

ssvsc0402

ssvsc0402: The specified virtual storage pool cannot carry out a migration.

Explanation

The virtual storage pool that includes the virtual disk to be migrated and the destination virtual storage pool are not controlled by the same virtualization switch group.

User action

Specify a virtual storage pool associated with the same virtualization switch group as that of the virtual storage pool to which the virtual disk to be migrated belongs.

ssvsc0403

ssvsc0403: The specified virtualization switch cannot carry out a migration.

Explanation

The specified virtualization switch does not form a redundant configuration with the following virtualization switch:

  • The virtualization switch associated with the virtual storage pool to which the virtual disk to be migrated belongs

User action

Specify the virtualization switch associated with the virtual storage pool to which the virtual disk to be migrated belongs.

ssvsc0404

ssvsc0404: The specified virtual disk cannot carry out a replication.

Explanation

The replication cannot be carried out in the same virtual disk.

User action

Specify a copy destination virtual disk that is different from the copy source virtual disk.

ssvsc0405

ssvsc0405: The specified virtualization switch cannot carry out a replication.

Explanation

The specified virtualization switch does not form a redundant configuration with the following virtualization switch:

  • The virtualization switch associated with the virtual storage pool to which the virtual disk to be replicated belongs

User action

Specify the virtualization switch associated with the virtual storage pool to which the virtual disk to be replicated belongs.

ssvsc0406

ssvsc0406: The maximum number of copying simultaneously was exceeded. Code = {0}

Explanation

No more copy processing can be started.

Parameters

0: VSC Engine error code

User action

Cancel copying in the Virtual Storage Window (Copy), or use the cancelrep command to cancel replication. For the maximum number of concurrent copy processing, refer to "Appendix D Limit Values".

ssvsc0407

ssvsc0407: The specified sessionID is not a session of a migration.

Explanation

The specified session ID is not for migration. Therefore, migration can neither be canceled nor terminated.

User action

Check the copy status in the Virtual Storage Window (Copy). Alternatively, use the getsession command to check the session type.

ssvsc0408

ssvsc0408: The specified sessionID is not a session of a replication.

Explanation

The specified session ID is not for replication. Therefore, replication can neither be canceled nor terminated.

User action

Check the copy status in the Virtual Storage Window (Copy). Alternatively, use the getsession command to check the session type.

ssvsc0409

ssvsc0409: The specified sessionID is not equivalent.

Explanation

Migration or replication is in progress with the session of the specified session ID, so the session cannot be terminated.

User action

Check the copy status in the Virtual Storage Window (Copy), then execute the command again when the status changes to "synchronized".

Alternatively, use the getsession command to check the copy status, then execute the command again when "Phase" changes to "equivalent".

ssvsc0410

ssvsc0410: Backup does not exist in the specified virtual disk.

Explanation

There is no migration backup for the virtual disk.

User action

Confirm that the target virtual disk has a backup disk in the Virtual Storage Window (Copy).

ssvsc0411

ssvsc0411: The specified virtual disk is now migration.

Explanation

The specified virtual disk is already in the process of migration.

User action

Check the copy status in the Virtual Storage Window (Copy). Alternatively, use the
getsession command to check the copying status.

If the following conditions are all met, it is likely that an internal error occurred:

  • The Virtual Storage Window (copy) does not display a session for the specified virtual disk.

  • The migration backup disk list window does not display the specified virtual disk.

  • The detailed information on already allocated physical disks displayed in the Virtual Storage Window (View and Create) includes the specified virtual disk.


  • If the getsession command indicates that the relevant copy session is present:

    Refresh the Virtual Storage Window (Copy). If the problem persists, close the Virtual Storage Window (Copy) and open it again. If the problem still persists, restart the admin client program.

  • If the getsession command indicates that the relevant copy session does not exist, or if the action taken as described in above fails to solve the problem:

    Refer to "6.3 Collecting Data", collect the necessary data for troubleshooting, then restart the Manager. Also, contact your Fujitsu engineer (CE or SE).

ssvsc0412

ssvsc0412: The specified virtual disk is now replication.

Explanation

The specified virtual disk is already in the process of replication.

User action

Check the copy status in the Virtual Storage Window (Copy). Alternatively, use the getsession command to check the copying status.

ssvsc0413

ssvsc0413: Failed to getting session information.

Explanation

Failed to get session information.

User action

Check the status information for the virtualization switch in the Virtual Storage Window (Maintenance). If the status information indicates an error (abnormal), check the virtualization switch or network for errors.

Alternatively, use the getvsw command to check the status information for the virtualization switch. If the status information indicates an error (abnormal), check the virtualization switch or network for errors.

ssvsc0414

ssvsc0414: Failed to starting migration. Code = {0}

Explanation

Migration could not be started because an error occurred in a virtualization switch.

Parameters

0: VSC Engine error code

User action

Referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

ssvsc0415

ssvsc0415: Failed to changing migration. Code = {0}

Explanation

Migration could not be changed because an error occurred in a virtualization switch.

Parameters

0: VSC Engine error code

User action

Referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

ssvsc0416

ssvsc0416: Failed to stopping migration. Code = {0}

Explanation

Migration could not be stopped because an error occurred in a virtualization switch.

Parameters

0: VSC Engine error code

User action

Referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

ssvsc0417

ssvsc0417: Failed to replicating migration backup. Code = {0}

Explanation

A migration backup could not be restored because an error occurred in a virtualization switch.

Parameters

0: VSC Engine error code

User action

Referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

ssvsc0418

ssvsc0418: Failed to deleting migration backup. Code = {0}

Explanation

A migration backup could not be deleted because an error occurred in a virtualization switch.

Parameters

0: VSC Engine error code

User action

Referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

ssvsc0419

ssvsc0419: Failed to starting replication. Code = {0}

Explanation

Replication could not be started because an error occurred in a virtualization switch.

Parameters

0: VSC Engine error code

User action

Referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

ssvsc0420

ssvsc0420: Failed to separation replication. Code = {0}

Explanation

Replication could not be isolated because an error occurred in a virtualization switch.

Parameters

0: VSC Engine error code

User action

If the VSC Engine error code is 0x3112, re-create the virtualization switch configuration information and then perform replication isolation again. If this does not solve the problem, referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

ssvsc0421

ssvsc0421: Failed to stopping replication. Code = {0}

Explanation

Replication could not be stopped because an error occurred in a virtualization switch.

Parameters

0: VSC Engine error code

User action

Referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

ssvsc0422

ssvsc0422: The specified replication point virtual disk does not exist.

Explanation

The specified name of the destination virtual disk is incorrect.

User action

Check the virtual disk in the Virtual Storage Window (View and Create), then specify a valid virtual disk name.

ssvsc0423

ssvsc0423: Failed to getting the session status. Code = {0}

Explanation

Session status information could not be obtained because an error occurred in a virtualization switch.

Parameters

0: VSC Engine error code

User action

Referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

ssvsc0424

ssvsc0424: The specified virtual disk cannot carry out a replication. Code = {0}

Explanation

The virtual storage pool that includes the virtual disk to be replicated and the destination virtual storage pool are not controlled by the same virtualization switch group.

Parameters

0: VSC Engine error code

User action

Specify a virtual storage pool associated with the same virtualization switch group as that of the virtual storage pool to which the virtual disk to be replicated belongs.

ssvsc0425

ssvsc0425: Failed to automatic changing migration. Code = {0} SessionID = {1}

Explanation

Migration could not be automatically changed because an error occurred in a virtualization switch.

Parameters

0: VSC Engine error code
1: A session ID.

User action

Referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

ssvsc0426

ssvsc0426: It is not in agreement with the real disk storage capacity of a migration place and a migration source.

Explanation

If migration is executed in a mode that does not retain a migration backup disk, the destination physical disk must have the same capacity as the source physical disk.

User action

Execute migration with the capacity of the destination physical disk equal to that of the source physical disk.

ssvsc0427

ssvsc0427: Unable to read all files.

Explanation

An attempt to read the entire copy history failed.

User action

Check whether the copy history file is damaged.

ssvsc0428

ssvsc0428: Unable to read some files. File name = {0}

Explanation

An attempt to read the copy history failed.

Parameters

0: Name of the copy history file

User action

Check whether the copy history file is damaged.

ssvsc0429

ssvsc0429: Failed to stopping replication.

Explanation

Replication could not be stopped.

User action

Confirm that:

  • The switch status in the Maintenance window is normal.

  • The Engine status is active.

If the problem persists, refer to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

ssvsc0430

ssvsc0430: Failed to stopping migration.

Explanation

Migration could not be stopped.

User action

Confirm that:

  • The switch status in the Maintenance window is normal.

  • The Engine status is active.

If the problem persists, refer to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

ssvsc0431

ssvsc0431: The specified virtual disk is not assigned to the virtual target.

Explanation

The virtual disk to be copied has not been allocated to a virtual target.

User action

Allocate the target virtual disk to a virtual target.

ssvsc0432

ssvsc0432: The capacity of the replication point virtual disk is insufficient.

Explanation

Replication cannot be carried out because the capacity of the virtual disk specified as the replication destination is smaller than that of the virtual disk of the replication source.

User action

Specify, as the replication destination, a virtual disk with a capacity larger than that of the replication source virtual disk.

ssvsc0433

ssvsc0433: It cannot copy from Encryption attribute volume to Non-Encryption attribute volume was detected.

Explanation

The encrypted volumes cannot be copied to the non-encrypted volumes.

User action

Specify a volume with the encryption attribute as the virtual disk of the replication destination. Alternatively, specify the "f" option and re-execute.

ssvsc0434

ssvsc0434: The copy from Encryption attribute volume to Non-Encryption attribute volume was carried out.

Explanation

Replication from the encrypted volumes to the non-encrypted volumes was carried out.

User action

If copying from an encrypted volume to a non-encrypted volume is not permitted, terminate the replication session.

ssvsc0435

ssvsc0435: The specified sessionID is now copying.

Explanation

The session with the specified ID is being copied, and so cannot be terminated.

User action

Check the copy status on the Virtual Storage Window (Copy), and re-execute the command when it has changed to the equivalency maintain status.
Alternatively, check the copy status using the getssession command and re-execute the command when the phase has become equivalent.

ssvsc0436

ssvsc0436: Failed to stopping migration. Code = {0} The number of succeeded in processing = {1}/{2}units

Explanation

An error occurred with a virtualization switch, and migration could not be stopped.

Parameters

0: VSC Engine error code
1: Number of units successfully processed
2: Number of units specified

User action

Referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

ssvsc0437

ssvsc0437: Failed to stopping migration. The number of succeeded in processing = {0}/{1}units

Explanation

Migration could not be stopped.

Parameters

0: Number of units successfully processed
1: Number of units specified

User action

Confirm that:

  • the switch status on the maintenance window is normal

  • the engine is in the activation status

If the problem persists, by referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, and contact your Fujitsu engineer (CE or SE).

ssvsc0438

ssvsc0438: Failed to getting session information. The number of succeeded in processing = {0}/{1}units

Explanation

Session information could not be obtained.

Parameters

0: Number of units successfully processed
1: Number of units specified

User action

Check the status information of the virtual switch on the Virtual Storage Window (Maintenance). If the status shows abnormal, check for errors in the virtual switch or the network.
Alternatively, check the status information of the virtualization switch using the getvsw command. If the status shows abnormal, check for errors in the virtual switch or the network.

ssvsc0439

ssvsc0439: The specified sessionID does not exist. The number of succeeded in processing = {0}/{1}units

Explanation

The specified session has already ended. Alternatively, an incorrect session ID has been specified.

Parameters

0: Number of units successfully processed
1: Number of units specified

User action

Check if the session ID exists on the Virtual Storage Window (Copy).

Check the session ID using the getsession command.

ssvsc0440

ssvsc0440: Failed to stopping replication. The number of succeeded in processing = {0}/{1}units

Explanation

Replication could not be stopped.

Parameters

0: Number of units successfully processed
1: Number of units specified

User action

Confirm that:

  • the switch status on the maintenance window shows normal

  • the engine is in the activation status

If the problem persists, by referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, and contact your Fujitsu engineer (CE or SE).

ssvsc0441

ssvsc0441: Failed to stopping replication. Code = {0} The number of succeeded in processing = {1}/{2}units

Explanation

An error occurred with a virtualization switch, and replication could not be stopped.

Parameters

0: VSC Engine error code
1: Number of units successfully processed
2: Number of units specified

User action

Referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

ssvsc0442

ssvsc0442: Failed to changing migration. Code = {0} The number of succeeded in processing = {1}/{2}units

Explanation

An error occurred with a virtualization switch, and migration could not be switched.

Parameters

0: VSC Engine error code
1: Number of units successfully processed
2: Number of units specified

User action

Referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

ssvsc0443

ssvsc0443: The specified sessionID is not equivalent. The number of succeeded in processing = {0}/{1}units

Explanation

The session with the specified ID is not in the equivalency maintain status, and so cannot be ended.

Parameters

0: Number of units successfully processed
1: Number of units specified

User action

Check the copy status on the Virtual Storage Window (Copy), and re-execute the command when it has changed to the equivalency maintain status.
Alternatively, check the copy status using the getssession command and re-execute the command when the phase has become equivalent.

ssvsc0444

ssvsc0444: Failed to replicating migration backup. Code = {0} The number of succeeded in processing = {1}/{2}units

Explanation

An error occurred with a virtualization switch, and the migration backup could not be restored.

Parameters

0: VSC Engine error code
1: Number of units successfully processed
2: Number of units specified

User action

Referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

ssvsc0445

ssvsc0445: Backup does not exist in the specified virtual disk. The number of succeeded in processing = {0}/{1}units

Explanation

The migration backup for the virtual disk cannot be found.

Parameters

0: Number of units successfully processed
1: Number of units specified

User action

Ensure that a backup disk exists for the virtual disk by checking the Virtual Storage Window (Copy).

ssvsc0446

ssvsc0446: Failed to deleting migration backup. Code = {0} The number of succeeded in processing = {1}/{2}units

Explanation

An error occurred with a virtualization switch, and the migration backup could not be deleted.

Parameters

0: VSC Engine error code
1: Number of units successfully processed
2: Number of units specified

User action

Referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

ssvsc0447

ssvsc0447: The specified virtual disk reaches an executable number of copies. Code = {0}

Explanation

The specified virtual disk has reached the maximum number of copies that can be executed. Therefore, no more copies can be made.

Parameters

0: VSC Engine error code

User action

Stop replication of the specified virtual disk of the copy source on the Virtual Storage Window (Copy) or using the cancelrep command.

For the maximum number of copies, refer to "Appendix D Limit Values".

ssvsc0448

ssvsc0448: The specified BackupDisk cannot be restored.

Explanation

The specified backup disk cannot be restored because it has already been restored. This backup disk can only be deleted.

User action

Use the Virtual Storage window (Copy) to delete the backup disk for the target virtual disk.

ssvsc0449

ssvsc0449: The specified BackupDisk cannot be restored.The number of succeeded in processing = {0}/{1}units

Explanation

The specified backup disk cannot be restored because it has already been restored. This backup disk can only be deleted.

Parameters

0: Number of units successfully created
1: Specified number of units

User action

Use the Virtual Storage window (Copy) to delete the backup disk for the target virtual disk.

ssvsc0500

ssvsc0500: The host name is invalid in the virtualization switch. Host name = {0}

Explanation

Failed to communicate with the virtualization switch because the host name of the virtualization switch is invalid.

Parameters

0: Host name of the virtualization switch used for communication

For virtualization switches other than the VS900 Model 200, the name of the virtualization switch is displayed as “virtualization switch name (host name)”.

User action

  • Solaris OS/Linux OS

    Confirm that:

    • The host name of the virtualization switch is registered in the /etc/hosts file.

    • The correct IP address of Ethernet port for virtualization control of the virtualization switch is entered in the /etc/hosts file.

  • Windows

    Confirm that:

    • The host name of the virtualization switch is registered in the %SystemRoot%\system32\drivers\etc\hosts file.

    • The correct IP address of Ethernet port for virtualization control of the virtualization switch is entered in the %SystemRoot%\system32\drivers\etc\hosts file.

ssvsc0501

ssvsc0501: The maximum number of registering virtualization switches was exceeded.

Explanation

No more virtualization switches can be registered.

User action

Delete unnecessary virtualization switches, then execute the command again. For the number of virtualization switches that can be registered, refer to "Appendix D Limit Values".

ssvsc0502

ssvsc0502: The host name of specified virtualization switch already exists.

Explanation

Multiple virtualization switches cannot be registered with the same host name.

User action

Check the registered virtualization switch information in the Virtual Storage Window (Maintenance). Alternatively, use the getvsw command to check the registered host names of virtualization switches.

ssvsc0503

ssvsc0503: Virtualization switch status is error. SwitchName = {0}

Explanation

The virtualization switch is in an error status.

Parameters

0: Name of the virtualization switch in error status

For virtualization switches other than the VS900 Model 200, the name of the virtualization switch is displayed as “virtualization switch name (host name)”.

User action

Verify the status of the target virtualization switch.

If the problem persists, refer to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

ssvsc0504

ssvsc0504: The specified device is deleted from devices subject to management of a storage resource.Please click a [delete] button,when you perform device exchange.Please perform again after deleting all the resources of virtual storage relevant to the specified device,when not performing device exchange.

Explanation

There is virtual configuration information for the virtualization switch.

User action

If you want to proceed with device exchange, click the <Delete> button.
If you do not want to proceed with device exchange, delete all resources of virtual storage related to the specified device and try again.

ssvsc0505

ssvsc0505: The corresponding information does not exist.

Explanation

The specified information does not exist.

User action

Verify the configuration information in the Virtual Storage Window (View and Create).

ssvsc0506

ssvsc0506: The virtualization switch is not initialized.

Explanation

The virtualization switch is not initialized.

User action

Use the vscecreateconfigfile command of VSC Engine to initialize the virtualization switch.

ssvsc0507

ssvsc0507: Failed to restoring of the trace level of VSC Engine. Code = {0}

Explanation

The VSC Engine trace level could not be set because an error occurred in a virtualization switch.

Parameters

0: VSC Engine error code

User action

Referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

ssvsc0508

ssvsc0508: Failed to restoring of virtualization switch composition data files. Code = {0}

Explanation

The configuration information in the virtualization switch could not be re-created because an error occurred in a virtualization switch.

Parameters

0: VSC Engine error code

User action

Referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

ssvsc0509

ssvsc0509: Failed to stopping VSC Engine.

Explanation

VSC Engine could not be stopped because an error occurred in a virtualization switch.

User action

Referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

ssvsc0510

ssvsc0510: Failed to change of the virtual enclosure BoxID. Code = {0}

Explanation

The virtual enclosure BoxID could not be changed because an error occurred in a virtualization switch.

Parameters

0: VSC Engine error code

User action

Referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

ssvsc0511

ssvsc0511: The virtualization switch is not registered as devices for management. Host name = {0}

Explanation

The virtualization switch is not registered as a device to be managed.

Parameters

0: Host name of the virtualization switch

For virtualization switches other than the VS900 Model 200, the name of the virtualization switch is displayed as “virtualization switch name (host name)”.

User action

On the ESC Resource Management Window, search for and add the device to be managed. If the problem persists, refer to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

ssvsc0512

ssvsc0512: The information of devices for management of a virtualization switch is error. Host name = {0}

Explanation

The managed device information for the virtualization switch is incorrect.

Parameters

0: Host name of the virtualization switch

For virtualization switches other than the VS900 Model 200, the name of the virtualization switch is displayed as “virtualization switch name (host name)”.

User action

On the Resource Management Window, perform the following procedures:

  1. Delete the device to be managed.

  2. Select Delete in the Replace Device message.

  3. Add and delete the device to be managed.

If the problem persists, refer to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

ssvsc0513

ssvsc0513: Failed to getting virtualization switch. Code = {0}

Explanation

Information could not be obtained because an error was generated at the virtualization switch.

Parameters

0: VSC Engine error code

User action

Refer to "6.3 Collecting Data" and collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

ssvsc0514

ssvsc0514: Failed to getting virtualization switch. Code = {0} Host name = {1}

Explanation

Information could not be obtained because an error was generated at the virtualization switch.

Parameters

0: VSC Engine error code

1: Host name of Virtualization switch

For virtualization switches other than the VS900 Model 200, the name of the virtualization switch is displayed as “virtualization switch name (host name)”.

User action

Refer to "6.3 Collecting Data" and collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

ssvsc0515

ssvsc0515: The virtual storage resources relevant to the specified virtualization switch exists. When you perform virtualization switch exchange, please perform again after invalidating the specified virtualization switch. Please perform again after deleting all the resources of virtual storage relevant to the specified virtualization switch, when performing virtualization switch delete.

Explanation

Virtual configuration information for the virtualization switch already exists.

Parameters

0: Virtualization switch name (host name)

User action

To replace the virtualization switch, use the Virtual Storage window (Maintenance) to disable the virtualization switch, and then execute the processing again.

To delete the virtualization switch, delete all of the resources for the virtual storage device associated with the specified virtualization switch, and then execute the processing again.

ssvsc0516

ssvsc0516: Failed to getting the host name of a virtualization switch.

Explanation

The host name of the virtualization switch could not be acquired.

User action

If the user has attempted to use the virtualization function start settings to register a switch that has an application function other than the VS900 series, no action is required because only VS900 virtualization switches are supported. These switches can still be used as normal switches without making any changes.

If the user has attempted to use the virtualization switch function start settings to register a VS900 series virtual switch, check the settings for the virtualization switch. If the problem persists, collect the data necessary for troubleshooting and contact a Fujitsu engineer (CE or SE).

Refer to "6.3 Collecting Data".

ssvsc0517

ssvsc0517: The slot position of the virtualization blade may be different from a position of registered information. Host name = {0}

Explanation

The virtualization blade may have been inserted into the wrong slot.

Parameters

0: Virtualization switch name (host name)

User action

Check the insertion position for the virtualization blade.

Otherwise, update the management status of physical resources to the latest status, and then execute the processing again

If the problem persists, collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

Refer to "6.3 Collecting Data".

ssvsc0518

ssvsc0518: A serial number of the virtualization blade is different from a serial number of registered information. Host name = {0}

Explanation

The user has attempted to either stop or disable the virtualization switch function for a virtualization blade, but the serial number for the virtualization blade that has been inserted in the slot does not match the registered information.

Parameters

0: Virtualization switch name (host name)

User action

Check the slot position and settings for the virtualization blade.

Otherwise, update the management status of physical resources to the latest status, and then execute the processing again

If the problem persists, collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

Refer to "6.3 Collecting Data".

ssvsc0519

ssvsc0519: The virtual storage resources relevant to the specified virtualization switch exists.

Explanation

Virtual configuration information for the virtualization switch already exists.

User action

To replace the virtualization switch, use the Virtual Storage window (Maintenance) to disable the virtualization switch, and then execute the processing again.

To delete the virtualization switch, delete all of the resources for the virtual storage device associated with the specified virtualization switch, and then execute the processing again.

ssvsc0521

ssvsc0521: Login failed for Virtualization Switch. IP address = {0}

Explanation

The login name or password is incorrect.

Parameters

0: IP address of Ethernet port for virtualization control of the connection destination virtualization switch

User action

Check the login name and password for the connection destination.

ssvsc0522

ssvsc0522: Connect failed for Virtualization Switch. IP address = {0}

Explanation

Failed in the connection to the virtualization switch.

Parameters

0: IP address of Ethernet port for virtualization control of the connection destination virtualization switch

User action

Check the following points, and then repeat the operation that resulted in issue of this error message:
・Has the virtualization switch registered in ETERNUS SF Storage Cruiser been powered up?
・Has the IP address of the virtualization switch registered in ETERNUS SF Storage Cruiser been changed?
・Is there a fault in the network environment?

ssvsc0523

ssvsc0523: Connect timeout for Virtualization Swicth. IP address = {0}

Explanation

A timeout occurred during connection to the virtualization switch.

Parameters

0: IP address of Ethernet port for virtualization control of the connection destination virtualization switch

User action

Check the following points, and then repeat the operation that resulted in issue of this error message:
・Has the virtualization switch registered in ETERNUS SF Storage Cruiser been powered up?
・Is there a fault in the network environment?

ssvsc0524

ssvsc0524: Network error for Virtualization Switch. IP address = {0}

Explanation

A communication fault occurred during connection to the virtualization switch.

Parameters

0: IP address of Ethernet port for virtualization control of the connection destination virtualization switch

User action

Check if there is a fault in the network environment, and then repeat the operation that resulted in issue of this error message.

If the problem persists, refer to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

ssvsc0525

ssvsc0525: Denied connection for Virtualization Switch. IP address = {0}

Explanation

The connection to the virtualization switch was refused.
There may already be two names logged in as admin users to the virtualization switch.

Parameters

0: IP address of Ethernet port for virtualization control of the connection destination virtualization switch

User action

Check if login restrictions have been set for the connection destination IP address of Ethernet port for virtualization control.
If you are logged into the virtualization switch as an admin user, log out and then repeat the operation that resulted in issue of this error.

ssvsc0526

ssvsc0526: Failed to getting Firmware Information.

Explanation

An error occurred during acquisition of the firmware information.

User action

Refer to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

ssvsc0527

ssvsc0527: Failed to getting License Information.

Explanation

License information acquisition failed because an error occurred during acquisition of the firmware information.

User action

Refer to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

ssvsc0528

ssvsc0528: Connect Failed for FTP server. IP address = {0}

Explanation

Connection to the FTP server failed.

Parameters

0: IP address of the connection destination FTP server

User action

Check the following points, and then repeat the operation that resulted in issue of this error message:
・Is the IP address of the specified FTP server correct?
・Is the FTP server activated?

ssvsc0529

ssvsc0529: Login failed for FTP server. IP address = {0}

Explanation

Login to the FTP server failed.

Parameters

0: IP address of the connection destination FTP server

User action

Check the following points, and then repeat the operation that resulted in issue of this error message:
・Are the specified user name and password correct?
・Are the specified user name and password set as an FTP server account?
・Do the FTP server access settings prohibit to access to the FTP server by the specified user?
・Do the FTP server access settings prohibit to access to the FTP server by the IP address of Ethernet port for virtualization control of the virtualization switch?

ssvsc0530

ssvsc0530: Connection timeout for FTP server. IP address = {0}

Explanation

A timeout occurred during connection to the FTP server.

Parameters

0: IP address of the connection destination FTP server

User action

Check the following points, and then repeat the operation that resulted in issue of this error message:
・Is the FTP server activated?
・Is there a fault in the network environment?

ssvsc0531

ssvsc0531: Network error for FTP server. IP address = {0}

Explanation

A communication error occurred during connection to the FTP server.

Parameters

0: IP address of the connection destination FTP server

User action

Check the following points, and then repeat the operation that resulted in issue of this error message:
・Is the FTP server activated?
・Is there a fault in the network environment?

ssvsc0532

ssvsc0532: The specified directory doesn't exist. Directory = {0}

Explanation

The specified directory could not be found.

Parameters

0: Specified directory

User action

Check the following points, and then repeat the operation that resulted in issue of this error message:
・Is the specified directory correct?
・Does the specified directory exist in the connection destination FTP server?

ssvsc0533

ssvsc0533: Failed to input information of the backup of the VSC Engine environment.

Explanation

The value entered for backup of the VSC Engine environment settings is incorrect.

User action

Check the following points, and then repeat backup of the VSC Engine environment settings:
・Is the FTP server activated?
・Is the FTP server IP address correct?
・Are the FTP server login name and password correct?
・Do the FTP server access settings prohibit to access to the FTP server by the specified user name?
・Do the FTP server access settings prohibit to access to the FTP server by the IP address of Ethernet port for virtualization control of the virtualization switch?
・Does the backup directory for the VSC Engine environment settings exist?
・Is writing to the backup directory for the VSC Engine environment settings permitted?
・Is there enough free space in the backup directory for the VSC Engine environment settings?

ssvsc0534

ssvsc0534: The maximum number of the backup files was exceeded in the specified directory.

Explanation

The VSC Engine configuration information could not be backed up because the maximum number of backup files stored under the specified directory has been exceeded.

User action

Delete backup files under the specified directory, or change the backup destination directory.

ssvsc0535

ssvsc0535: Failed to input information of firmware installation. Firmware = {0}

Explanation

The information required for firmware installation is incorrect.

Parameters

0: Type of firmware being installed (FOS, SAS, VSC Engine)

User action

The information required for installation of the firmware might have changed during firmware installation. Check the following information and then install the firmware again:

・Storage directory of the FOS firmware, and the stored FOS firmware
・Storage directory of the SAS firmware, and the stored SAS firmware
・Storage directory of the VSC Engine firmware, and the stored VSC Engine firmware
・FOS configuration filename being backed up
・Backup directory of the VSC Engine configuration file

ssvsc0536

ssvsc0536: Input value of the FOS configuration is invalid.

Explanation

An incorrect value was entered for backup of the FOS settings information.

User action

Check the following points, and then execute backup of the FOS settings information again.
・Is the FTP server activated?
・Is the IP address of the FTP server correct?
・Are the FTP server login name and password correct?
・Does the FTP server configuration prohibit access by the specified user name?
・Does the FTP server configuration prohibit access by the IP address of Ethernet port for virtualization control of the virtualization switch?
・Does the backup directory for the VSC configuration file exist?
・Is writing to the backup directory for the VSC configuration file permitted?
・Is there enough space in the backup directory for the VSC settings information?

ssvsc0537

ssvsc0537: Input value of the VSC Engine environment is invalid.

Explanation

An incorrect value was entered for restoration of the VSC Engine environment settings.

User action

Check the following points, and then execute restoration of the VSC Engine environment settings again:.
・Is the FTP server activated?
・Is the IP address of the FTP server correct?
・Are the FTP server login name and password correct?
・Does the FTP server configuration prohibit access by the specified user name?
・Does the FTP server configuration prohibit access by the IP address of Ethernet port for virtualization control of the virtualization switch?
・Does the VSC Engine configuration file being restored exist in the specified directory?

ssvsc0538

ssvsc0538: Failed to creating the backup file of the VSC Engine environment. File name = {0}

Explanation

Backup file generation failed for the VSC Engine environment settings.

Parameters

0: Filename

User action

Check whether the file exists.
Check whether writing to the directory is permitted.
A backup file that does not have the host name attached to the start of the filename may be generated. Such a file is not a valid backup file of the VSC Engine environment settings. Therefore, do not use such a file to restore the VSC Engine environment settings.

ssvsc0539

ssvsc0539: Firmware version doesn't supported. Version = {0}

Explanation

The FOS firmware version is not supported.

Parameters

0: FOS firmware version

User action

Check the FOS firmware version.
If the FOS firmware version is not supported, then install one supported by the virtualization switch.

ssvsc0540

ssvsc0540: Firmware update is operating.

Explanation

Firmware installation is in progress.

User action

Wait until installation of the firmware ends, then try again.

ssvsc0541

ssvsc0541: Failed to executing command. Command = {0}

Explanation

Execution of FOS and VSC Engine command failed.

Parameters

0: Name of executed command

User action

  • If command is vscerestore:

Restore the VSC Engine configuration, then reactivate the virtualization switch in order to apply the VSC Engine configuration to it.

  • If command is not vscerestore:

Re-execute the operation for which this error message was displayed.

If recovery is not possible after the above action, refer to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

ssvsc0542

ssvsc0542: Failed to setting of the virtualization function because no adjustment of the state of the VSC Engine was detected.

Explanation

The virtualization function settings failed because an incompatibility was detected in the VSC Engine status.

User action

Refresh the virtual storage window (Maintenance window).
Then, configure the virtualization function again.

ssvsc0543

ssvsc0543: Failed to setting of the virtualization function because the VSC Engine is working.

Explanation

The following virtualization function settings could not be set because the VSC Engine is operating:

・Virtualization function settings for the local switch
・Virtualization function settings for the redundancy switch
・Port number setting

User action

Execute the following procedures:

  1. On the virtual storage window (Maintenance window), click <Enable> and set the logical status of the virtualization switch to "Enabled".

  2. On the virtual storage window (Maintenance window), click <Stop> to stop the VSC Engine.

  3. On the virtual storage window (Maintenance window), click <Disable> and set the logical status of the virtualization switch to "Disabled".

  4. Configure the virtualization function again.

ssvsc0544

ssvsc0544: Failed to login the Switch.

Explanation

Completion confirmation processing for the firmware installation terminated abnormally.

User action

Reactivate the virtualization switch, and then check the firmware version number.

ssvsc0546

ssvsc0546: The input value for the restoring of the FOS configuration is not correct.

Explanation

An incorrect value was entered for restoration of the FOS settings information.

User action

Check the following points, and then execute restoration of the FOS settings information again:.
・Is the FTP server activated?
・Is the IP address of the FTP server correct?
・Are the FTP server login name and password correct?
・Does the FTP server configuration prohibit access by the specified user name?
・Does the FTP server configuration prohibit access by the IP address of Ethernet port for virtualization control of the virtualization switch?
・Does the FOS configuration file being restored exist in the specified directory?

ssvsc0548

ssvsc0548: Failed to transferring and registering SSH key.

Explanation

The SSH key settings failed.

User action

Check the status of the targeted switch on the ESC resource management window, then check for a password error. If there was a password error, then update the ESC registration information (for details, refer to the "ETERNUS SF Storage Cruiser User's Guide", section "Environment Configuration" > "Fibre Channel Switch" > "SN200 (Brocade) Fibre Channel switch" > "Problem handling (FAQ)", item "A warning for a device is displayed (in yellow)").
Then, take the following actions:

  • Firmware installation

Restore the VSC Engine configuration, then reactivate the virtualization switch in order to apply the VSC Engine configuration to it.

  • Virtualization function settings

Wait a few moments, then execute the virtualization function settings again.

  • Restoration of VSC Engine configuration

Restore the VSC Engine configuration, then reactivate the virtualization switch in order to apply the VSC Engine configuration to it.

If recovery is not possible after the above action, then collect the data needed for troubleshooting as explained in "6.3 Collecting Data",a contact your Fujitsu engineer (CE or SE).

ssvsc0549

ssvsc0549: The input value for the basic setting of virtualization switch is not correct.

Explanation

An incorrect value was entered in the basic settings for the storage virtualization function.

User action

Check for incorrect values entered in the basic settings of the storage virtualization function.

ssvsc0550

ssvsc0550: File name is not specified.

Explanation

The file name is not specified.

User action

Check whether the file name was specified in the entered values.

ssvsc0551

ssvsc0551: The specified value already exists same directory name on the FTP server.

Explanation

A folder with the specified name already exists in the FTP server.

User action

Check the following points, and then repeat the operation for which this error message was issued:

・Is the entered value correct?
・Is a directory on the FTP server the same as the file name?

ssvsc0552

ssvsc0552: Failed to collection of log information. Failed module = {0}

Explanation

Log information could not be collected.

Parameters

0: Module for which collection not possible (CP, CP0, CP1, VSCEngine)

User action

Check the following points, and then execute collection of log information again:
・Is the FTP server activated?
・Is the IP address of the FTP server correct?
・Are the FTP server login name and password correct?
・Does the FTP server configuration prohibit access by the specified user name?
・Does the FTP server configuration prohibit access by the IP address of Ethernet port for virtualization control of the virtualization switch?
・Does the log information backup destination directory exist?
・Is writing to the log information backup destination directory permitted?
・Is there enough space in the log information backup destination directory?

ssvsc0554

ssvsc0554: The log remote directory of VSC engine is not correct. Remote directory = {0}

Explanation

VSC log information could not be collected to the specified directory because it is incorrect. The log information may have been collected to the FTP server home directory.

Parameters

0: Log information storage directory

User action

Check whether the log information was collected to the FTP server home directory.
If it was not, then check the value entered as the log collection directory and try again.

ssvsc0555

ssvsc0555: Firmware update is failed. Firmware = {0}

Explanation

The firmware update failed.

Parameters

0: Firmware type for which firmware update was executed (FOS, SAS, VSC Engine)

User action

  • If Firmware = FOS

Execute installation of the FOS, SAS, and VSC Engine firmware again.

  • If Firmware = SAS

Execute installation of the SAS and VSC Engine firmware again.

  • If Firmware = VSCEngine

Execute installation of the VSC Engine firmware again.

If recovery is not possible after the above action, then collect the data needed for troubleshooting as explained in "6.3 Collecting Data",a contact your Fujitsu engineer (CE or SE).

ssvsc0556

ssvsc0556: It failed in the existence check of the backup file of the VSC Engine environment. File name = {0}

Explanation

A backup file was created for the VSC Engine environment settings but the file existence check terminated abnormally.

Parameters

0: Filename of the VSC Engine environment settings that were backed up

User action

  • Firmware installation

Check the following points, and then repeat the backup of the VSC Engine environment settings:
・Does the VSC Engine configuration backup directory exist?
・Is writing to the VSC Engine configuration backup directory permitted?
・Is there enough space in the VSC Engine configuration backup directory?

After checking the above points, repeat installation of the firmware.
If the same message is displayed despite taking the above action, then collect the data needed for troubleshooting as explained in "6.3 Collecting Data",a contact your Fujitsu engineer (CE or SE).

  • Backup of VSC Engine environment settings

Check the following points:
・Does the VSC Engine configuration backup directory exist?
・Is writing to the VSC configuration backup directory permitted?
・Is there enough space in the VSC Engine configuration backup directory?

After checking the above points, repeat the backup of the VSC Engine environment settings.

ssvsc0600

ssvsc0600: Because the number of VSC Engine of farm versions is old, this function cannot be executed.

Explanation

The firmware version of the VSC Engine concerned does not meet the requirement for this function to be executed.

User action

Refer to the VSC Engine manual and upgrade the firmware of the VSC Engine.

ssvsc0700

ssvsc0700: Unable to read a composition data files of virtual storage.

Explanation

Failed to read the configuration information file.

User action

Confirm the status of the vsccompose file in the following directory.

Platform

Directory that vsccompose exists

Windows

$TMP_DIR\Manager\var\opt\FJSVssmgr\current
($TMP_DIR means "Work Directory" specified at the Manager installation.)

Solaris OS,
Linux

/var/opt/FJSVssmgr/current

  • No disk error has occurred.

  • The directory does not contain another directory.

  • The directory contains only files with extension .repository.

  • The directory contains a file.

If no file exists, use the commit script to restore the backup virtual storage configuration information into the following directory. After restoration, restart the manager.

  • Solaris OS, Linux: /vsccompose

  • Windows: \vsccompose

When all the conditions above are met, the configuration information file may be corrupt.
If the problem persists, refer to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

ssvsc0701

ssvsc0701: Unable to update a configuration file of virtual storage.

Explanation

The configuration information file could not be written to the directory specified.
Or, the update process of configuration information to VSC Engine failed.

User action

Take the following procedures to make checks.

  1. Update the Virtual Storage Window (Maintenance) screen to check the latest status of the virtualization switch.

    • If the virtualization switche is stopped:

      Check if the virtualization switch has been started. If not, proceed to step 2.

    • If the virtualization switch is working:

      Proceed to step 3.

  2. Take the following procedures.

    1. Log into the virtualization switch by the username "admin" and enter the vscecreateconfigfile command to initialize the configuration information.

    2. Log into the virtualization switch by the username "admin" and enter the reboot command to reboot the virtualization switch.

    3. After the virtualization switch has been rebooted, proceed to step 3.

  3. Once again update the Virtual Storage Window (Maintenance) screen to the latest status to check the status of the configuration information.

    • When the state of the composition data is Inconsistent

      Refer to "6.2.3.3 Restoring the configuration information of a virtualization switch" to restore the configuration information.

    • When the state of the composition data is consistent

      Confirm the status of the vsccompose file in the following directory.

      Platform

      Directory that vsccompose exists

      Windows

      $TMP_DIR\Manager\var\opt\FJSVssmgr\current
      ($TMP_DIR means "Work Directory" specified at the Manager installation.)

      Solaris OS,
      Linux

      /var/opt/FJSVssmgr/current

      • No disk error has occurred.

      • The directory or file is not write-protected.

      • The file system of the directory has sufficient free disk space.

If migration or replication is in progress, cancel copying that has ended abnormally in the copying status view.

When all the conditions above are met, the configuration information file may be corrupt.
If the problem persists, refer to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

ssvsc0702

ssvsc0702: Copy-log file does not exist.

Explanation

The copy log file in the configuration data file is incorrect.

User action

Confirm the status of the vsclog file in the following directory.

Platform

Directory that vsclog exists

Windows

$TMP_DIR\Manager\var\opt\FJSVssmgr\current
($TMP_DIR means "Work Directory" specified at the Manager installation.)

Solaris OS,
Linux

/var/opt/FJSVssmgr/current

  • The directory or file has not been moved or deleted.

After confirming, restart VSC Manager.

ssvsc0703

ssvsc0703: Failed to updating of the copy-log file.

Explanation

The copy log file could not be written to the directory specified.

User action

Confirm the status of the vsclog file in the following directory.

Platform

Directory that vsclog exists

Windows

$TMP_DIR\Manager\var\opt\FJSVssmgr\current
($TMP_DIR means "Work Directory" specified at the Manager installation.)

Solaris OS,
Linux

/var/opt/FJSVssmgr/current

  • No disk error has occurred.

  • The directory or file is not write-protected.

  • The file system has sufficient free disk space.

When all the conditions above are met, the copy log file may be corrupt. Move or delete the copy log file.
If the problem persists, refer to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

ssvsc0705

ssvsc0705: Failed to updating of the trace file.

Explanation

Failed to write to the log file.

User action

Confirm the status of the vsclog file in the following directory.

Platform

Directory that vsclog exists

Windows

$TMP_DIR\Manager\var\opt\FJSVssmgr\current
($TMP_DIR means "Work Directory" specified at the Manager installation.)

Solaris OS,
Linux

/var/opt/FJSVssmgr/current

  • No disk error has occurred.

  • The directory or file is not write-protected.

  • The file system has sufficient free disk space.

When all the conditions above are met, the copy log file may be corrupt. Move or delete the copy log file.
If the problem persists, refer to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

ssvsc0800

ssvsc0800: A network socket error occurred in communication with a virtualization switch. Host name = {0}

Explanation

An error occurred in communication with the virtualization switch.

Parameters

0: Name of the virtualization switch used for communication

For virtualization switches other than the VS900 Model 200, the name of the virtualization switch is displayed as “virtualization switch name (host name)”.

User action

Confirm that:

  • VSC Engine starts

  • The network environment is normal

If the problem persists, refer to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

ssvsc0801

ssvsc0801: The host name is invalid in virtualization switch. Host name = {0}

Explanation

Failed to communicate with the virtualization switch because the host name of the virtualization switch is invalid.

Parameters

0: Host name of the virtualization switch used for communication

For virtualization switches other than the VS900 Model 200, the name of the virtualization switch is displayed as “virtualization switch name (host name)”.

User action

Confirm that:

  • The port number of VSC Engine is correct.

  • VSC Engine is running.

  • Confirm that the network environment is normal.

If the problem persists, refer to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

ssvsc0802

ssvsc0802: The specified physical disk is in a busy state.

Explanation

The specified physical disk returned a busy status.

User action

Execute the command again.

ssvsc0803

ssvsc0803: VSC Engine is in an unusual state.

Explanation

The virtualization switch encountered an internal error.

User action

Referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

ssvsc0804

ssvsc0804: A network timeout error occurred in communication with a virtualization switch. Host name = {0}

Explanation

In communication with the virtualization switch, the wait time (three minutes) was exceeded.

Parameters

0: Host name of the virtualization switch used for communication

For virtualization switches other than the VS900 Model 200, the name of the virtualization switch is displayed as “virtualization switch name (host name)”.

User action

Confirm that:

  • The virtualization switch specified as %HostName is operating.

  • The network environment is normal.

If the problem persists, refer to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

ssvsc0805

ssvsc0805: The unusual state occurred in the communication during a virtualization switch.

Explanation

The communication between virtualization switches failed.

User action

Confirm that the network environment is normal.

If the problem persists, refer to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

ssvsc0806

ssvsc0806: A network socket error occurred in communication with a virtualization switch. Host name = {0} The number of succeeded in making = {1}/{2}units

Explanation

An error occurred during communication with the virtualization switch.

Parameters

0: Host name of the virtualization switch to communicate with

For virtualization switches other than the VS900 Model 200, the name of the virtualization switch is displayed as “virtualization switch name (host name)”.

1: Number of units created successfully
2: Specified number of units

User action

Confirm that:

  • VSC Engine starts

  • The network environment is normal

If the problem persists, refer to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

ssvsc0807

ssvsc0807: The host name is invalid in virtualization switch. Host name = {0} The number of succeeded in making = {1}/{2}units

Explanation

Communication with the virtualization switch failed because the host name of the virtualization switch was invalid.

Parameters

0: Host name of the virtualization switch to communicate with

For virtualization switches other than the VS900 Model 200, the name of the virtualization switch is displayed as “virtualization switch name (host name)”.
1: Number of units created successfully
2: Specified number of units

User action

Ensure that:

  • The port number of the VSC Engine is valid.

  • The VSC Engine is active.

  • The network environment contains no error.

If the problem persists, refer to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

ssvsc0808

ssvsc0808: The specified physical disk is in a busy state. The number of succeeded in making = {0}/{1}units

Explanation

The busy status was reported from the specified physical disk.

Parameters

0: Number of units successfully created
1: Specified number of units

User action

Reenter the command.

ssvsc0809

ssvsc0809: VSC Engine is in an unusual state. The number of succeeded in making = {0}/{1}units

Explanation

An internal error occurred on the visualization switch.

Parameters

0: Number of units successfully created
1: Specified number of units

User action

Referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

ssvsc0810

ssvsc0810: A network timeout error occurred in communication with a virtualization switch. Host name = {0} The number of succeeded in making = {1}/{2}units

Explanation

In communication with the virtualization switch, the wait time (three minutes) was exceeded.

Parameters

0: Host name of the virtualization switch

For virtualization switches other than the VS900 Model 200, the name of the virtualization switch is displayed as “virtualization switch name (host name)”.
1: Number of units successfully created
2: Specified number of units

User action

Ensure that:

  • The virtualization switch that was set by %HostName is active.

  • The network environment contains no error.

If the problem persists, refer to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

ssvsc0811

ssvsc0811: The unusual state occurred in the communication during a virtualization switch. The number of succeeded in making = {0}/{1}units

Explanation

Communication between visualization switches failed.

Parameters

0: Number of units successfully created
1: Specified number of units

User action

Check for errors in the network environment.

If the problem persists, refer to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

ssvsc0812

ssvsc0812: A network socket error occurred in communication with a virtualization switch. Host name = {0} The number of succeeded in deleting = {1}/{2}units

Explanation

Communication between visualization switches failed.

Parameters

0: Host name of the virtualization switch to communicate with

For virtualization switches other than the VS900 Model 200, the name of the virtualization switch is displayed as “virtualization switch name (host name)”.
1: Number of units successfully deleted
2: Specified number of units

User action

Confirm that:

  • VSC Engine starts

  • The network environment is normal

If the problem persists, refer to "6.3 Collecting Data""6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

ssvsc0813

ssvsc0813: The host name is invalid in virtualization switch. Host name = {0} The number of succeeded in deleting = {1}/{2}units

Explanation

Communication with the virtualization switch failed because the host name of the virtualization switch was invalid.

Parameters

0: Host name of the virtualization switch to communicate with

For virtualization switches other than the VS900 Model 200, the name of the virtualization switch is displayed as “virtualization switch name (host name)”.
1: Number of units successfully deleted
2: Specified number of units

User action

Ensure that:

  • The port number of the VSC Engine is valid.

  • The VSC Engine is active.

  • The network environment contains no error.

If the problem persists, refer to "6.3 Collecting Data""6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

ssvsc0814

ssvsc0814: The specified physical disk is in a busy state. The number of succeeded in deleting = {0}/{1}units

Explanation

The busy status was reported from the specified physical disk.

Parameters

0: Number of units successfully deleted
1: Specified number of units

User action

Reenter the command.

ssvsc0815

ssvsc0815: VSC Engine is in an unusual state. The number of succeeded in deleting = {0}/{1}units

Explanation

An internal error occurred in the visualization switch.

Parameters

0: Number of units successfully deleted
1: Specified number of units

User action

Referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

ssvsc0816

ssvsc0816: A network timeout error occurred in communication with a virtualization switch. Host name = {0} The number of succeeded in deleting = {1}/{2}units

Explanation

In communication with the virtualization switch, the wait time (three minutes) was exceeded.

Parameters

0: Host name of the virtualization switch

For virtualization switches other than the VS900 Model 200, the name of the virtualization switch is displayed as “virtualization switch name (host name)”.
1: Number of units successfully deleted
2: Specified number of units

User action

Ensure that:

  • The virtualization switch that was set by %HostName is active.

  • The network environment contains no error.

If the problem persists, refer to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

ssvsc0817

ssvsc0817: The unusual state occurred in the communication during a virtualization switch. The number of succeeded in deleting = {0}/{1}units

Explanation

Communication between virtualization switches failed.

Parameters

0: Number of units successfully deleted
1: Specified number of units

User action

Check for errors in the network environment.

If the problem persists, refer to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

ssvsc0818

ssvsc0818: The specified physical disk is in a busy state. LogicalVolume = {1} The number of succeeded in making = {2}/{3}units

Explanation

Busy Status was returned from the specified physical disk.

Parameters

1: Physical disk information
2: Number of units successfully created
3: Specified number of units

User action

Execute the command again.

ssvsc0819

ssvsc0819: The unusual state occurred in the communication during a virtualization switch. LogicalVolume = {1} The number of succeeded in making = {2}/{3}units

Explanation

Communication between virtualization switches failed.

Parameters

1: Physical disk information
2: Number of units successfully created
3: Specified number of units

User action

Check the network environment for errors.

If the problem persists, refer to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

ssvsc0820

ssvsc0820: VSC Engine is in an unusual state. LogicalVolume = {1} The number of succeeded in making = {2}/{3}units

Explanation

An internal error occurred in the virtualization switch.

Parameters

1: Physical disk information
2: Number of units successfully deleted
3: Specified number of units

User action

Referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

ssvsc0821

ssvsc0821: A network socket error occurred in communication with a virtualization switch. Host name = {0} LogicalVolume = {1} The number of succeeded in making = {2}/{3}units

Explanation

An error occurred during communication with the virtualization switch.

Parameters

0: Host name of the virtualization switch to communicate with

For virtualization switches other than the VS900 Model 200, the name of the virtualization switch is displayed as “virtualization switch name (host name)”.
1: Physical disk information
2: Number of units successfully created
3: Specified number of units

User action

Confirm that:

  • VSC Engine starts

  • The network environment is normal

If the problem persists, refer to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

ssvsc0822

ssvsc0822: The host name is invalid in virtualization switch. Host name = {0} LogicalVolume = {1} The number of succeeded in making = {2}/{3}units

Explanation

Communication with the virtualization switch failed because the host name of the virtualization switch is invalid.

Parameters

0: Host name of the virtualization switch communicated with

For virtualization switches other than the VS900 Model 200, the name of the virtualization switch is displayed as “virtualization switch name (host name)”.
1: Physical disk information
2: Number of units successfully created
3: Specified number of units

User action

Confirm that:

  • The port number of VSC Engine is correct.

  • VSC Engine is active.

  • The network environment contains no error.

If the problem persists, refer to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

ssvsc0823

ssvsc0823: A network timeout error occurred in communication with a virtualization switch. Host name = {0} LogicalVolume = {1} The number of succeeded in making = {2}/{3}units

Explanation

A timeout (3 minutes) occurred during communication with the virtualization switch.

Parameters

0: Host name of the virtualization switch communicated with

For virtualization switches other than the VS900 Model 200, the name of the virtualization switch is displayed as “virtualization switch name (host name)”.
1: Physical disk information
2: Number of units successfully created
3: Specified number of units

User action

Confirm that:

  • The virtualization switch set with %HostName is active.

  • The network environment contains no error.

If the problem persists, refer to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

ssvsc0824

ssvsc0824: A network socket error occurred in communication with a virtualization switch. Host name = {0} The number of succeeded in processing = {1}/{2}units

Explanation

Communication with a virtualization switch failed.

Parameters

0: Host name of virtualization switch in communication with

For virtualization switches other than the VS900 Model 200, the name of the virtualization switch is displayed as “virtualization switch name (host name)”.
1: Number of units successfully processed
2: Number of units specified

User action

Confirm that:

  • VSC Engine starts

  • The network environment is normal

If the problem persists, by referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, and contact your Fujitsu engineer (CE or SE).

ssvsc0825

ssvsc0825: The host name is invalid in virtualization switch. Host name = {0} The number of succeeded in processing = {1}/{2}units

Explanation

Communication with a virtualization switch failed because the host name of the virtualization switch is incorrect.

Parameters

0: Host name of the virtualization switch in communication with

For virtualization switches other than the VS900 Model 200, the name of the virtualization switch is displayed as “virtualization switch name (host name)”.
1: Number of units successfully processed
2: Number of units specified

User action

Confirm that:

  • VSC Engine port number is correct

  • VSC Engine is running

  • the network environment is normal

Referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

ssvsc0826

ssvsc0826: VSC Engine is in an unusual state. The number of succeeded in processing = {0}/{1}units

Explanation

An internal error was generated with the virtualization switch.

Parameters

0: Number of units successfully processed
1: Number of units specified

User action

Referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

ssvsc0827

ssvsc0827: A network timeout error occurred in communication with a virtualization switch. Host name = {0} The number of succeeded in processing = {1}/{2}units

Explanation

The communication timeout (3 minutes) for the virtualization switch has exceeded.

Parameters

0: Host name of virtualization switch

For virtualization switches other than the VS900 Model 200, the name of the virtualization switch is displayed as “virtualization switch name (host name)”.
1: Number of units successfully processed
2: Number of units specified

User action

Confirm that:

  • The virtualization switch specified with %HostName is activated

  • The network environment is normal

If the problem persists, by referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, and contact your Fujitsu engineer (CE or SE).

ssvsc0828

ssvsc0828: The unusual state occurred in the communication during a virtualization switch. The number of succeeded in processing = {0}/{1}units

Explanation

Communication with a virtualization switch failed.

Parameters

0: Number of units successfully processed
1: Number of units specified

User action

Confirm that the network environment is normal.

If the problem persists, by referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, and contact your Fujitsu engineer (CE or SE).

ssvsc0829

ssvsc0829: VSC Engine ends abnormaly with error Code = {0}

Explanation

The operation terminated abnormally because an error was returned from the VSC Engine.

Parameters

0: VSC Engine error code

User action

Refer to “VSC Engine”.

ssvsc0830

ssvsc0830: VSC Engine ends abnormaly with error Code = {0} The number of succeeded in processing = {1}/{2}units

Explanation

The operation terminated abnormally because an error was returned from the VSC Engine.

Parameters

0: VSC Engine error code
1: Number of units successfully created
2: Specified number of units

User action

Refer to “VSC Engine”.

ssvsc0902

ssvsc0902: Command Started "{0}"

Explanation

The command started.

Parameters

0: Name of the command that started

User action

None

ssvsc0903

ssvsc0903: Command Terminated "{0}"

Explanation

The command ended.

Parameters

0: Name of the command that ended

User action

None

ssvsc0905

ssvsc0905: CommitScript error occurred. output={0}

Explanation

An error occurred in the commit script.

Parameters

0: Error information of the commit script

User action

Confirm that the commit script is correctly written.
Confirm that the commit script runs normally by itself.

ssvsc0906

ssvsc0906: CommitScript does not exist. COMMIT_SCRIPT = {0}

Explanation

The commit script file cannot be found in the specified folder.

Parameters

0: File name of the commit script

User action

Confirm that:

  • the commit script file is stored in the specified folder

  • the directory or file specified in the commit script is not write-protected.

ssvsc0907

ssvsc0907: CommitScript standard output={0}

Explanation

The commit script output %Message to standard output.

Parameters

0: Message that was output

User action

None

ssvsc0908

ssvsc0908: CommitScript standard error. output={0}

Explanation

The commit script output %Message to standard error output.

Parameters

0: Error message that was output

User action

Confirm that the commit script is correctly written.
Confirm that the commit script runs normally by itself.

ssvsc0909

ssvsc0909: VSC Manager stopped normally.

Explanation

VSC Manager stopped normally.

User action

None

ssvsc0913

ssvsc0913: Delete operation terminated. Because the device is used for Virtualization switch.

Explanation

The specified device is used by virtual storage.

User action

The device cannot be deleted.
To delete the device, release all physical disks of the specified device.

ssvsc1300

ssvsc1300: Mismatching is in the composition information on virtual storage.

Explanation

There is an inconsistency in the configuration information for the virtual storage device.

User action

Collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

Refer to "6.3 Collecting Data".

ssvsc1301

ssvsc1301: The virtual switch of a different switch group was specified. Switch group = {0}

Explanation

A virtualization switch from a different switch group has been specified.

Parameters

0: The specified switch group

User action

Open the Virtual Storage window (Maintenance), specify all of the virtualization switches that belong to the same switch group, and then execute the command again.

ssvsc1302

ssvsc1302: It belongs to the same switch group and there is a virtual switch which is not specified. Switch group = {0}

Explanation

A virtualization switch from a different switch group has been specified.

Parameters

0: The specified switch group

User action

Open the Virtual Storage window (Maintenance), specify all of the virtualization switches that belong to the same switch group, and then execute the command again.

ssvsc1304

ssvsc1304: The management information of the physical resource has latest possibilities.

Explanation

The SAN management information or the relationship management information may not be in the latest status.

User action

Update the SAN management information or the relationship management information to the latest.

Otherwize, check the connection cable of physical resources and the following settings of physical resources.

  • host affinity of storage device

  • virtualization switch zoning

If the problem persists, by referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, and contact your Fujitsu engineer (CE or SE).

ssvsc1305

ssvsc1305: The specified LogicalVolume is connected with plural affinity groups. LogicalVolume = {0}

Explanation

The logical volume is configured with multiple affinity groups.

Parameters

0: Specified logical volume

User action

Check the configuration of affinity groups related to the specified logical volume on the storage device.

ssvsc1306

ssvsc1306: The specified LogicalVolume is connected with plural HostLUNs. LogicalVolume = {0}

Explanation

The logical volume is configured with multiple Host LUNs.

Parameters

0: Specified logical volume

User action

Check the configuration of Host LUNs related to the specified logical volume on the storage device.

ssvsc1307

ssvsc1307: The most suitable real disk where associated CM was considered cannot be elected on the specified virtual disk.

Explanation

A virtual disk that is optimal in terms of assigned CMs cannot be configured for the specified virtual disk because it consists of physical disks with different assigned CMs.

Parameters

0: VSC Engine error code

User action

Take one of the following actions:

Select the physical disks directly, without using the [Candidate Selection] or [Automatic Creation] button.

Use the migration function to increase the capacity of the disk.

ssvsc1308

ssvsc1308: Failed to liberate assignment of a virtual disk. Code = {0}

Explanation

The allocation for the virtualization disk failed to be released because an error occurred on the virtualization switch.

Parameters

0: VSC Engine error code

User action

Collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

Refer to "6.3 Collecting Data".

ssvsc1309

ssvsc1309: The specified copy security group name already exists.

Explanation

It is not possible to create multiple copy security groups with the same name.

User action

Use the Virtual Storage window (View and Create) to check the names of the existing copy security groups, and specify a copy security group name that is not being used.

ssvsc1310

ssvsc1310: The maximum number of creating copy security group was exceeded.

Explanation

No more copy security groups can be created.

User action

Delete any copy security groups that are no longer required, and then execute the processing again.

Refer to Appendix D, "Appendix D Limit Values" for information about the number of copy security groups that can be created.

ssvsc1311

ssvsc1311: The specified copy security group does not exist.

Explanation

Either there is a problem with the copy security group, or the copy security group does not exist.

User action

Use the Virtual Storage window (View and Create) to check the name of the copy security group.

ssvsc1312

ssvsc1312: The virtual enclosure is registered with the specified copy security group. Copy security group name = {0}

Explanation

Copy security groups where virtual enclosures have been registered cannot be deleted.

Parameters

0: Name of the copy security group

User action

Use the Virtual Storage window (View and Create) to check whether there are virtual enclosures in the copy security group to be deleted.

ssvsc1313

ssvsc1313: The specified virtual enclosure is already registered with the copy security group. Virtual enclosure name = {0}

Explanation

The specified virtual enclosure has already been registered with the copy security group.

Parameters

0: Name of the virtual enclosure

User action

Use the Virtual Storage window (View and Create) to check which virtual enclosures have been registered with the copy security group.

ssvsc1314

ssvsc1314: The maximum number of virtual enclosure that can be registered to the copy security group is exceeded.

Explanation

No more virtual enclosures can be registered with the copy security group.

User action

Delete any virtual enclosures in the copy security group that are no longer required, and then execute the processing again.

Refer to Appendix D, "Appendix D Limit Values" for information about the number of virtual enclosures that can be registered in each copy security group.

ssvsc1315

ssvsc1315: The specified virtual enclosure is not registered with the copy security group. Virtual enclosure name = {0}

Explanation

The specified virtual enclosure has not been registered with the specified copy security group.

Parameters

0: Name of the virtual enclosure

User action

Use the Virtual Storage window (View and Create) to check the copy security group.

ssvsc1316

ssvsc1316: The specified virtual enclosure was not able to be released.

Explanation

A virtual disk in the specified virtual enclosure may be being used by an ETERNUS SF AdvancedCopy Manager replication.

User action

Use the Virtual Storage window (Copy) to check whether an ETERNUS SF AdvancedCopy Manager replication is being performed.

ssvsc1317

ssvsc1317: The specified copy security group is already registered. Copy security group name = {0}

Explanation

The specified copy security group has already been registered with the virtual enclosure.

Parameters

0: Name of the copy security group

User action

Use the Virtual Storage window (View and Create) to check which copy security groups have been registered with the virtual enclosure.

ssvsc1318

ssvsc1318: The specified copy security group is not registered with the virtual enclosure. Copy security group name = {0}

Explanation

The specified virtual enclosure has not been registered with the specified copy security group.

Parameters

0: Name of the copy security group

User action

Use the Virtual Storage window (View and Create) to check the copy security group.

ssvsc1319

ssvsc1319: The specified copy security group was not able to be released.

Explanation

It is possible that a virtual disk in a virtual enclosure that has been registered with the specified copy security group is being used by an ETERNUS SF AdvancedCopy Manager replication.

User action

Use the Virtual Storage window (Copy) to check whether an ETERNUS SF AdvancedCopy Manager replication is being performed.

ssvsc1320

ssvsc1320: The specified number of maximum copy sessions is not effective values.

Explanation

An invalid value has been specified for the maximum number of copy sessions.

User action

Specify a valid value and then execute the processing again.

Refer to Appendix D, "Appendix D Limit Values" for information about valid values.

ssvsc1321

ssvsc1321: A value that is less than the number under executions of copy sessions cannot be set.

Explanation

The value specified for the maximum number of copy sessions cannot be set because it is lower than the number of copy sessions currently in progress.

User action

Use the Virtual Storage window (Copy) to check the number of copy sessions currently in progress, and then make the setting again.

Refer to “Max copy multiplicity” in Appendix D, "Appendix D Limit Values" for information about the maximum number of copy sessions.

ssvsc1322

ssvsc1322: The limitation value of the copy permission virtual enclosure that can be registered in a virtual enclosure is exceeded.

Explanation

There are too many virtual enclosures that permit ETERNUS SF AdvancedCopy Manager replications that can be registered with virtual enclosures.

User action

Use the Virtual Storage window (Copy) to check the copy security groups registered with the virtual enclosure.

ssvsc1323

ssvsc1323: Because the copy security group is registered with the specified virtual enclosure, it is not possible to delete it. Virtual enclosure name = {0}

Explanation

Virtual enclosures where copy security groups have been registered cannot be deleted.

User action

Release all of the copy security groups that have been registered with the virtual enclosure.

ssvsc1324

ssvsc1324: Because the specified virtual enclosure is registerd with the copy security group, it is not possible to delete it. Virtual enclosure name = {0}

Explanation

Virtual enclosures that have been registered with copy security groups cannot be deleted.

Parameters

0: Name of the virtual enclosure

User action

Release the virtual enclosure from all of the copy security groups with which it has been registered.

ssvsc1325

ssvsc1325: Because the copy operates by the specified virtual enclosure, a virtual enclosure cannot be deleted.

Explanation

The specified virtual enclosure cannot be deleted because one of its virtual disks is being used by an ETERNUS SF AdvancedCopy Manager replication.

User action

Use the Virtual Storage window (Copy) to check whether an ETERNUS SF AdvancedCopy Manager replication is being performed.

ssvsc1326

ssvsc1326: The specified copy security group does not exist. The number of succeeded in processing = {0}/{1}units

Explanation

Either there is a problem with the copy security group, or the copy security group does not exist.

Parameters

0: Number of units successfully created
1: Specified number of units

User action

Use the Virtual Storage window (View and Create) to check the name of the copy security group.

ssvsc1327

ssvsc1327: The virtual enclosure is registered with the specified copy security group. Copy security group name = {0} The number of succeeded in processing = {1}/{2}units

Explanation

Copy security groups where virtual enclosures have been registered cannot be deleted.

Parameters

0: Name of the copy security group
1: Number of units successfully created
2: Specified number of units

User action

Use the Virtual Storage window (View and Create) to check whether there are virtual enclosures in the copy security group to be deleted.

ssvsc1328

ssvsc1328: Because the copy security group is registered with the specified virtual enclosure, it is not possible to delete it. Virtual enclosure name = {0} The number of succeeded in processing = {1}/{2}units

Explanation

Virtual enclosures where copy security groups have been registered cannot be deleted.

Parameters

0: Name of the virtual enclosure
1: Number of units successfully created
2: Specified number of units

User action

Release all of the copy security groups that have been registered with the virtual enclosure.

ssvsc1329

ssvsc1329: Because the specified virtual enclosure is registerd with the copy security group, it is not possible to delete it. Virtual enclosure name = {0} The number of succeeded in processing = {1}/{2}units

Explanation

Virtual enclosures that have been registered with copy security groups cannot be deleted.

Parameters

0: Name of the virtual enclosure
1: Number of units successfully created
2: Specified number of units

User action

Release the virtual enclosure from all of the copy security groups with which it has been registered.

ssvsc1330

ssvsc1330: Because the copy operates by the specified virtual enclosure, a virtual enclosure cannot be deleted. The number of succeeded in processing = {0}/{1}units

Explanation

The specified virtual enclosure cannot be deleted because one of its virtual disks is being used by an ETERNUS SF AdvancedCopy Manager replication.

Parameters

0: Number of units successfully created
1: Specified number of units

User action

Use the Virtual Storage window (Copy) to check whether an ETERNUS SF AdvancedCopy Manager replication is being performed.

ssvsc1331

ssvsc1331: HostLUN number of the specified physical disk is different between VSC engines.

Explanation

The HostLUN number for the specified physical disk is not the same on all VSC Engines.

User action

Check the configuration of the storage device and the virtualization switch.

If the problem persists, collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).

Refer to "6.3 Collecting Data".

ssvsc1332

ssvsc1332: The specified physical disk is different switch group of copying source virtual disk.

Explanation

The specified physical disk does not belong to the same switch group as the copy source virtual disk.

User action

Check whether the specified physical disk belongs to the same switch group as the copy source virtual disk.

ssvsc1336

ssvsc1336: Some paths for LogicalVolume are using same CM. LogicalVolume = {0}

Explanation

The configuration is not recommended for a virtual storage environment because some logical volume paths use the same CM.

Parameters

0: Targeted logical volume number

User action

Correct the storage configuration and physical connections so that the same CM is not used. For details on the recommended configurations, refer to the "ETERNUS SN200 Model 540 Fibre Channel Switch Virtualization Blade and VS900 Model 300 Virtualization Switch System Build Procedure".

ssvsc1337

ssvsc1337: Some virtualization switches are using same CM between the virtualization switch and the storage. CM number = {0}

Explanation

The configuration is not recommended for a virtual storage environment because the paths between virtualization switches and storage include paths where more than one virtualization switch uses a CM.

Parameters

0: Targeted CM number

User action

Correct the storage configuration and physical connections so that the same CM is not used. For details on the recommended configurations, refer to the "ETERNUS SN200 Model 540 Fibre Channel Switch Virtualization Blade and VS900 Model 300 Virtualization Switch System Build Procedure".