This appendix describes the error messages output by VSC Manager.
Either English or Japanese messages are output as specified in environment variable LANG.
Messages output by VSC Manager consist of those output to the system log and those output to the operator terminal.
Message output format
VSC Manager outputs messages in the following output format:
label: error_type: message_ID: message_text
VSC Manager outputs messages with the following labels:
Label | Meaning |
---|---|
FSP_FJSVssvsc_Service | Common service |
FSP_FJSVssvsc_Virtual | Virtual disk operation |
FSP_FJSVssvsc_Copy | Migration or replication operation |
FSP_FJSVssvsc_Mainte | Maintenance operation |
VSC Manager outputs messages with the following error types:
Error type | Meaning |
---|---|
ERR | Take action as instructed. |
WARNING | Take any action required as instructed. |
INFO | The system administrator need not take any action. |
Item | Description |
---|---|
Message text | Text of a message to be output. Each message is output in the following format: Message ID : Message text |
Explanation | Explains why this message is output. |
Parameters | Explains the meanings of any parameters included in the message. |
User action | Explains the action to be taken for this message. |
ssvsc0000
Explanation
An unexpected error occurred.
User action
Referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
ssvsc0001
Explanation
The command name is invalid.
User action
Specify a correct command name.
For more information, refer to "Appendix B Admin Server Commands".
ssvsc0002
Explanation
An option is in an incorrect input form.
User action
Confirm that:
A value is specified after an option that requires a value.
A value is not specified after an option that doest not require a value
A correct option is specified.
No option is specified more than once.
Only one value is specified after an option.
For more information, refer to "Appendix B Admin Server Commands".
ssvsc0003
Explanation
No command string is specified.
User action
Refer to "Appendix B Admin Server Commands", and specify a command.
ssvsc0004
Explanation
The -h option and other options are specified simultaneously.
User action
The -h option cannot be specified simultaneously with other options.
To specify help, specify the -h option alone.
For more information, refer to "Appendix B Admin Server Commands".
ssvsc0005
Explanation
An option has an invalid value.
Parameters
Option with an invalid value specified
User action
Confirm that the %Option values:
Are the correct character type.
Are the correct length.
Are within the correct specification range.
Are correctly delimited with a comma or colon.
Consist of as many values as required.
Re-enter the command with the option specified in a valid form.
For more information, refer to "Appendix B Admin Server Commands".
ssvsc0006
Explanation
A mandatory option is not specified.
User action
Re-enter the command with the mandatory option specified.
For more information, refer to "Appendix B Admin Server Commands".
ssvsc0007
Explanation
There is already an existing virtualization switch with the specified host name.
User action
Specify a unique name for the virtualization switch.
For more information, refer to "Appendix B Admin Server Commands".
ssvsc0008
Explanation
The specified virtual target name already exists.
User action
Specify a unique name for the virtual target.
For more information, refer to "Appendix B Admin Server Commands".
ssvsc0009
Explanation
The specified combination of a WWN and LUN already exists.
User action
Specify a unique combination of a WWN and LUN.
For more information, refer to "Appendix B Admin Server Commands".
ssvsc0010
Explanation
The specified physical disk name already exists.
User action
Specify a unique name for the physical disk.
For more information, refer to "Appendix B Admin Server Commands"
ssvsc0101
Explanation
A mismatch was found in the configuration information between virtual switch = {0} and VSC Manager.
Parameters
0: The name of the virtual switch that does not match the configuration information
For virtualization switches other than the VS900 Model 200, the name of the virtualization switch is displayed as “virtualization switch name (host name)”.
User action
Perform the following for the virtualization switch (%SwitchName):
Restore the configuration information by referring to "6.2.3.3 Restoring the configuration information of a virtualization switch".
Confirm that the status of the configuration information of %SwitchName matches that on the Virtual Storage Window (Maintenance). Alternatively, using the getvsw command, confirm that the ConfigFile for %SwitchName has the correct status.
ssvsc0102
Explanation
The configuration data file contains %Item with an incorrectly specified value.
Parameters
0: Name of the item with an incorrectly specified value
User action
Verify the value specified for %Item in the configuration data file.
Correct any incorrect value, and restart the manager.
If it is not operating normally, refer to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
ssvsc0103
Explanation
No connection to VSC Manager can be established from the Virtual Storage Window (View and Create). VSC Manager may not be operating normally.
Parameters
0: IP address
1: Port number
User action
Confirm that VSC Manager is operating normally.
If it is not operating normally, refer to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
ssvsc0104
Explanation
No connection to VSC Manager can be established from the Virtual Storage Window. The VSC Manager may not be operating normally.
Parameters
0: IP address
1: Port number
User action
Confirm that VSC Manager is operating normally.
If it is not operating normally, refer to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
ssvsc0105
Explanation
An unrecoverable error was detected in communication between the Virtual Storage Window and VSC Manager. VSC Manager probably ended abnormally during communication, or the Virtual Storage Window and VSC Manager may have versions that do not match.
Parameters
0: IP address
1: Port number
User action
Confirm that VSC Manager is operating normally, or verify the versions of the Virtual Storage Window and VSC Manager. If VSC Manager is not operating normally, refer to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
ssvsc0106
Explanation
VSC Manager is not running.
User action
Re-execute the manager command.
If the problem persists, refer to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
ssvsc0107
Explanation
The user attempted to disable a virtualization switch, but it has already been disabled.
Parameters
0: Virtualization switch name (host name)
User action
Refresh the Virtual Storage (Maintenance) window. Then check whether the specified virtualization switch has been enabled in the Virtual Storage (Maintenance) window.
ssvsc0108
Explanation
The user attempted to enable a virtualization switch, but it has already been enabled.
Parameters
0: Virtualization switch name (host name)
User action
Refresh the Virtual Storage (Maintenance) window. Then check whether the specified virtualization switch has been disabled in the Virtual Storage (Maintenance) window.
ssvsc0109
Explanation
The virtualization blade may have been inserted into the wrong slot.
Parameters
0: Virtualization switch name (host name)
User action
Check the insertion position for the virtualization blade.
Otherwise, update the management status of physical resources to the latest status, and then execute the processing again
If the problem persists, refer to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
ssvsc0110
Explanation
The name of the switch may not match the registered information.
Parameters
0: Virtualization switch name (host name)
User action
Check whether the specified switch name is correct.
ssvsc0111
Explanation
The slot position and serial number of a virtualization blade do not match the registered information.
Parameters
0: Virtualization switch name (host name)
User action
When replacing virtualization blades, make sure that the new virtualization blade is inserted into the same slot as the old virtualization blade. When changing the slot position for a virtualization blade, make sure the serial number is the same as before.
ssvsc0200
Explanation
The requested processing could not be executed because processing was in progress on the virtualization switch.
The processing in progress was canceled.
Parameters
0: Virtualization switch name (host name)
User action
Perform the operation again.
If the problem persists, refer to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
ssvsc0201
Explanation
The host name of the virtualization switch is incorrect, or the virtualization switch is not registered.
User action
Confirm that the virtualization switch specified in the Virtual Storage Window (Maintenance) exists. Also, use the getvsw command to check whether the virtualization switch is registered. Then, specify the correct host name for the virtualization switch, or register the virtualization switch.
ssvsc0202
Explanation
Multiple virtual storage pools cannot be created with the same name.
User action
Check virtual storage pool names in the Virtual Storage Window (View and Create), and specify a virtual storage pool name not being used.
ssvsc0203
Explanation
The specified name of the virtual storage pool is incorrect. Alternatively, the specified virtual storage pool does not exist.
User action
Check the virtual storage pool name on the Virtual Storage Window (View and Create).
ssvsc0204
Explanation
Multiple physical disks cannot be registered with the same name.
User action
Check physical disk names in the Virtual Storage Window (View and Create), and specify a physical disk name not being used.
ssvsc0205
Explanation
The specified physical disk name is incorrect. Alternatively, the specified physical disk doesn't exist.
User action
In the Virtual Storage Window(View and Create), check the physical disk name.
ssvsc0206
Explanation
An attempt was made to create a virtual enclosure with an existing name.
User action
Check virtual enclosure names in the Virtual Storage Window (View and Create).
ssvsc0207
Explanation
The specified virtual enclosure name is incorrect. Alternatively, the specified virtual enclosure doesn't exist.
User action
Check virtual enclosure names in the Virtual Storage Window (View and Create).
ssvsc0208
Explanation
Multiple virtual targets cannot be created with the same name.
User action
Check virtual target names in the Virtual Storage Window (View and Create), and specify a virtual target name not being used.
ssvsc0209
Explanation
The virtual target name is incorrect. Alternatively, the specified virtual target doesn't exist.
User action
Check virtual target names in the Virtual Storage Window (View and Create).
ssvsc0210
Explanation
Multiple virtual disks cannot be created with the same name.
User action
Check virtual disk names in the Virtual Storage Window (View and Create), and specify a virtual disk name not being used.
ssvsc0211
Explanation
The specified virtual storage pool does not have any physical disk.
User action
Check the virtual storage pool in the Virtual Storage Window (View and Create), and register a physical disk in the virtual storage pool.
ssvsc0212
Explanation
A virtual disk with the specified capacity cannot be created because the virtual storage pool or physical disk is short of free space. Alternatively, migration could not be started because the empty capacity of the physical disk in copy destination virtual storage pool is smaller than the capacity of the copy source virtual disk.
User action
Check the size of unallocated space in the virtual storage pool or physical disk in the Virtual Storage Window (View and Create).
If a virtual disk is automatically created or capacity is added:
Register physical disks corresponding to the configuration conditions in the virtual storage pool.
Delete unnecessary virtual disks created in the specified virtual storage pool, which consist of physical disks corresponding to the configuration conditions.
If a virtual disk is selected and created or capacity is added by the user:
Select a physical disk with unallocated space.
Register the physical disk in the virtual storage pool.
Delete unnecessary virtual disks created in the specified virtual storage pool.
If a migration is started:
Check the empty capacity of the copy source virtual disk.
Register the physical disk in the virtual storage pool.
Delete unnecessary virtual disks created in the specified virtual storage pool.
ssvsc0213
Explanation
The virtual disk name is incorrect. Alternatively, the specified virtual disk doesn't exist.
User action
Check the name of the virtual disk being created on the Virtual Storage Window (View and Create).
ssvsc0214
Explanation
Multiple virtualization switches cannot be created with the same host name.
User action
Check the registered host names of virtualization switches in the Virtual Storage Window (Maintenance ). Alternatively, use the getvsw command to check the registered host names of virtualization switches.
ssvsc0215
Explanation
The virtualization switch with %HostName is being replaced. Functions are restricted during switch replacement.
Parameters
0: Name of the virtualization switch in an exchange state
For virtualization switches other than the VS900 Model 200, the name of the virtualization switch is displayed as “virtualization switch name (host name)”.
User action
After the virtualization switch is replaced, perform registration of the virtualization switch on the ESC Resource Management Window. Then, refer to "6.2.3.3 Restoring the configuration information of a virtualization switch".
ssvsc0216
Explanation
The memory space is running low.
User action
Restart VSC Manager.
If the problem persists, refer to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
ssvsc0217
Explanation
An invalid virtual storage pool name was specified. Alternatively, the specified virtual disk doesn't exist.
Parameters
0: Number of units successfully deleted
1: Specified number of units
User action
Check the name of the virtual storage pool on the Virtual Storage Window (View and Create).
ssvsc0218
Explanation
An invalid physical disk name was specified. Alternatively, the specified physical disk doesn't exist.
Parameters
0: Number of units successfully released
1: Specified number of units
User action
Check physical disk names in the Virtual Storage Window (View and Create).
ssvsc0219
Explanation
An invalid virtual enclosure name is specified, or the specified virtual enclosure name doesn't exist.
Parameters
0: Number of units successfully deleted
1: Specified number of units
User action
Check virtual enclosure names in the Virtual Storage Window (View and Create).
ssvsc0220
Explanation
An invalid virtual target name was specified. Alternatively, the specified virtual target doesn't exist.
Parameters
0: Number of units successfully deleted
1: Specified number of units
User action
Check virtual target names in the Virtual Storage Window (View and Create).
ssvsc0221
Explanation
An invalid virtual disk name was specified. Alternatively, the specified virtual disk doesn't exist.
Parameters
0: Number of units successfully deleted
1: Specified number of units
User action
Check the names of created virtual disks in the Virtual Storage Window (View and Create).
ssvsc0222
Explanation
Different firmware versions of VSC Engine are being used in a redundant configuration.
User action
Set up a redundant configuration using virtualization switches with the same firmware versions. If the problem persists, referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, and contact your Fujitsu engineer (CE or SE).
ssvsc0223
Explanation
The virtualization switch with %HostName is being replaced. Functions are restricted during switch replacement.
Parameters
0: Host name of the virtualization switch being replaced
For virtualization switches other than the VS900 Model 200, the name of the virtualization switch is displayed as “virtualization switch name (host name)”.
1: Number of units successfully deleted
2: Specified number of units
User action
After the virtualization switch is replaced perform registration on the ESC Resource Management Window. Then restore the configuration information; refer to "6.2.3.3 Restoring the configuration information of a virtualization switch".
ssvsc0224
Explanation
The virtualization switch with %HostName is being replaced. Functions are restricted during switch replacement.
Parameters
0: Host name of the virtualization switch being replaced
For virtualization switches other than the VS900 Model 200, the name of the virtualization switch is displayed as “virtualization switch name (host name)”.
User action
After the virtualization switch is replaced perform registration on the ESC Resource Management Window, and then restore the configuration information; refer to "6.2.3.3 Restoring the configuration information of a virtualization switch".
ssvsc0225
Explanation
Physical disk information could not be obtained because an error occurred when storage unit information was being retrieved.
User action
Referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
ssvsc0226
Explanation
The commit script start program was deleted.
Parameters
0: Path of the commit script start program file
User action
Referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
ssvsc0227
Explanation
The number of SCSI command queues of virtual targets exceeds the limit value for a CA port.
Parameters
0: Physical disk information
1: Information regarding the number of queues
2: Number of excess queues
User action
Select a physical disk from another CA port.
ssvsc0228
Explanation
The number of SCSI command queues of virtual targets exceeds the limit value for a CA port.
Parameters
0: Virtual disk information
1: Physical disk information
2: Information regarding the number of queues
3: Number of excess queues
User action
Using a physical disk under another CA port, create a virtual disk again.
ssvsc0229
Explanation
Processing to check whether the number of SCSI command queues of virtual targets exceeds the limit value has failed.
Parameters
0: VSC Engine error code
User action
Referring to "6.3 Collecting Data," collect the necessary data for troubleshooting, and then contact your Fujitsu engineer (CE or SE).
ssvsc0230
Explanation
A virtualization switch of the same name is not allowed to multi-register.
User action
Check virtualization switch names on the virtual storage window (maintenance) to set an unused virtualization switch name.
ssvsc0231
Explanation
The virtualization switch for %HostName is being replaced. While the device is being replaced, the functions are restricted.
Parameters
0: The host name of a virtualization switch that is being replaced
For virtualization switches other than the VS900 Model 200, the name of the virtualization switch is displayed as “virtualization switch name (host name)”.
1: Quantity that has succeeded in release
2: Specified quantity
User action
Since exchange virtualization switch, after the virtualization switch is replaced, execute "6.2.3.3 Restoring the configuration information of a virtualization switch" and perform registration on the ESC Resource Management Window.
ssvsc0232
Explanation
The necessary information could not be acquired from the principal switch.
User action
Check the following points:
Check whether there are any problems with the virtualization switches associated with the specified virtual storage pool or with the network environment for the FC switches in cascading connections to these virtualization switches.
Check whether the FC switches in cascading connections to the virtualization switches associated with the specified virtual storage pool have been registered.
ssvsc0233
Explanation
A failure occurred in a virtualization switch, and the information acquisition failed.
Parameters
0: Virtualization switch host name
For virtualization switches other than the VS900 Model 200, the name of the virtualization switch is displayed as “virtualization switch name (host name)”.
User action
Refer to "6.3 Collecting Data" to collect required data for troubleshooting and contact the Fujitsu engineer (CE/SE).
ssvsc0234
Explanation
The virtualization switch (%HostName) is being replaced. During device replacement, functions will be limited.
Parameters
0: Name of the host of the virtualization switch being replaced
For virtualization switches other than the VS900 Model 200, the name of the virtualization switch is displayed as “virtualization switch name (host name)”.
1: Number of units successfully processed
2: Number of units specified
User action
After the virtualization switch is replaced perform registration on the Physical Device Replacement Window. Refer to "6.2.3.3 Restoring the configuration information of a virtualization switch".
ssvsc0235
Explanation
The virtualization switch has been registered with the VSC Manager.
Parameters
0: Virtualization switch name (host name)
User action
None
ssvsc0236
Explanation
A virtualization switch has either been registered successfully or the virtualization switch function has started successfully.
User action
None
ssvsc0237
Explanation
A virtualization switch has failed to be registered or the virtualization switch function has failed to start.
User action
Take the action appropriate for the error messages that are displayed after this message.
ssvsc0238
Explanation
The virtualization switch function has stopped successfully.
User action
None
ssvsc0239
Explanation
Stopping the virtualization switch function has failed.
User action
Take the action appropriate for the error messages that are displayed after this message.
ssvsc0240
Explanation
The virtualization switch has been deleted from the VSC Manager.
Parameters
0: Virtualization switch name (host name)
User action
None
ssvsc0241
Explanation
There is a virtual disk for the specified physical disk.
User action
Use the Virtual Storage window (View and Create) to check that no virtual disks have been created for the specified physical disk.
ssvsc0300
Explanation
No more virtual storage pools can be created.
User action
Delete unnecessary virtual storage pools and try again.
For the number of virtual storage pools that can be created, refer to "Appendix D Limit Values."
ssvsc0301
Explanation
A virtual storage pool in which a physical disk is registered cannot be deleted.
User action
Confirm that the specified name of the virtual storage pool is correct.
In the Virtual Storage Window (View and Create), check for a physical disk in the virtual storage pool to be deleted.
If the virtual storage pool contains a physical disk, release the physical disk from the virtual storage pool before executing the command.
ssvsc0302
Explanation
An attempt was made to register a physical disk that has already been registered.
User action
Verify the WWN and LUN in the Virtual Storage Window (View and Create), and execute the command again.
ssvsc0303
Explanation
No more physical disks can be registered.
User action
Release unnecessary physical disks, and execute the command again.
For the number of physical disks that can be registered, refer to "Appendix D Limit Values".
ssvsc0304
Explanation
VSC Engine could not find the specified physical disk.
Parameters
0: VSC Engine error code
User action
Check the storage unit management window or the Design Sheet specifications to verify the WWN and LUN to be registered. In the related management windows, confirm that all the physical disks that constitute virtual disks are connected to virtualization switches.
ssvsc0305
Explanation
The specified physical disk did not respond.
Parameters
0: VSC Engine error code
User action
Check the power supply and connection cable of the disk unit.
Alternatively check the following settings of the disk unit; host worldwide name, host affinity and virtualization switch zoning.
For details, refer to "3.4.1.1 Using the zoning function of a virtualization switch" and "3.4.1.2 Using the host table settings mode of ETERNUS and GR".
If the problem persists, collect the necessary data for troubleshooting and contact your Fujitsu engineer (CE or SE).
ssvsc0306
Explanation
The specified physical disk is a non-supported disk unit or not a disk unit at all.
Parameters
0: VSC Engine error code
User action
Use supported hardware for operation.
For details, refer to "1.4.1 Supported hardware".
ssvsc0307
Explanation
Physical disk registration failed because an error occurred in a virtualization switch.
Parameters
0: VSC Engine error code
User action
Referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
ssvsc0308
Explanation
The specified physical disk is allocated to the real space of a virtual disk.
User action
Delete the allocated virtual disk and then execute the command again.
ssvsc0309
Explanation
The specified physical disk is registered in another virtual storage pool.
User action
Verify the relationship between the virtual storage pool and physical disk, which is registered in the virtual storage pool, in the Virtual Storage Window (View and Create), and execute the command again.
ssvsc0310
Explanation
No more virtual enclosures can be created.
User action
Delete unnecessary virtual enclosures, and execute the command again.
For the number of virtual enclosures that can be created, refer to "Appendix D Limit Values".
ssvsc0311
Explanation
An attempt was made to create a virtual enclosure with a BOX-ID that was already created.
User action
Verify the box_id for the virtual enclosure in the Virtual Storage Window (View and Create).
ssvsc0312
Explanation
A virtual enclosure in which a virtual target is registered cannot be deleted.
User action
Confirm that the specified virtual enclosure name is correct.
In the Virtual Storage Window (View and Create), check for a virtual target in the virtual enclosure to be deleted.
If the virtual enclosure contains a virtual target, delete the virtual target from the virtual enclosure before executing the command.
ssvsc0313
Explanation
A virtual target cannot be created because the relationship between the virtualization switch and the virtual enclosure is invalid.
User action
Verify the relationship between the registered virtualization switch and the virtual enclosure in the Virtual Storage Window (View and Create), and execute the command again.
ssvsc0314
Explanation
No more virtual targets can be created in the same virtual enclosure.
Parameters
0: VSC Engine error code
User action
Delete unnecessary virtual targets, and execute the command again.
For the number of virtual targets that can be created in the same virtual enclosure, refer to "Appendix D Limit Values".
ssvsc0315
Explanation
No more virtual targets can be created in the virtualization switch.
Parameters
0: VSC Engine error code
User action
Delete unnecessary virtual targets, and execute the command again.
For the number of virtual targets that can be created in a virtualization switch, refer to "Appendix D Limit Values".
ssvsc0316
Explanation
A virtual target could not be created because an error occurred in a virtualization switch.
Parameters
0: VSC Engine error code
User action
Referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
ssvsc0317
Explanation
The virtual target to which a virtual disk is assigned cannot be deleted.
User action
Unassign the virtual disk from the virtual target, and delete the virtual target.
ssvsc0318
Explanation
A virtual target could not be deleted because an error occurred in a virtualization switch.
Parameters
0: VSC Engine error code
User action
Referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
ssvsc0319
Explanation
A virtual disk cannot be allocated to the specified virtual target because the virtualization switch that controls the corresponding virtual storage pool does not have the virtual target.
User action
Check the Virtual Storage Window (View and Create) and ensure that the virtual disk is specified for the corresponding storage pool on the virtualization switch.
ssvsc0320
Explanation
The specified virtual target belongs to a different virtual enclosure.
User action
Check the virtual target name in the Virtual Storage Window (View and Create). Specify a virtual target that belongs to the same virtual enclosure.
ssvsc0322
Explanation
An attempt was made to create an extent that constitutes a virtual disk that exceeds the maximum number of extents that can be created.
User action
Take either of the following procedures on the Virtual Storage Window (View and Create) screen.
If a virtual disk is automatically created or capacity is added:
Register physical disks corresponding to the configuration conditions in the virtual storage pool.
Specify another virtual storage pool.
If a virtual disk is selected and created or capacity is added by the user:
Refer to "A.2.3 Displaying the virtual storage pool" to check the number of unallocated extents of the "View and Create" screen and specify physical disks so that the number of extents may not exceed the maximum permissible number. For details, refer to "Appendix D Limit Values".
Execute "Candidate Selection".
Register physical disks in the virtual storage pool.
If capacity is added, there are cases where the number of extents has already reached the maximum permissible number.
In this case, use Migration to expand the capacity.
ssvsc0324
Explanation
No more virtual disks can be created in the virtualization switch.
Parameters
0: VSC Engine error code
User action
Delete unnecessary virtual disks, and execute the command again.
For the number of virtual disks that can be created in a virtualization switch, refer to "Appendix D Limit Values".
ssvsc0325
Explanation
A virtual disk could not be created because an error occurred in a virtualization switch.
Parameters
0: VSC Engine error code
User action
Referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
ssvsc0326
Explanation
You cannot manipulate a virtual disk that is being copied.
Parameters
0: VSC Engine error code
User action
Check the copy status in the Virtual Storage Window (Copy). Alternatively, use the getsession command to check the copy status.
ssvsc0327
Explanation
A virtual disk could not be deleted because an error occurred in a virtualization switch.
Parameters
0: VSC Engine error code
User action
Referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
ssvsc0328
Explanation
Each host allocation number in the same virtual target must be unique.
User action
Check the host allocation numbers of virtual disks in the Virtual Storage Window (View and Create).
Specify a host allocation number that is unique within the virtual target.
ssvsc0329
Explanation
No more host allocation numbers can be created in the same virtual target.
Parameters
0: VSC Engine error code
User action
Delete unnecessary host allocation numbers, and execute the command again.
For the number of host allocation numbers that can be created in a virtual target, refer to "Appendix D Limit Values".
ssvsc0330
Explanation
A host allocation number could not be set because an error occurred in a virtualization switch.
Parameters
0: VSC Engine error code
User action
Referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
ssvsc0331
Explanation
An error was detected during access to the physical disk from the virtualization switch.
Parameters
0: VSC Engine error code
User action
Execute the command again.
If the problem persists, refer to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
ssvsc0332
Explanation
An error occurred in the virtualization switch.
Parameters
0: VSC Engine error code
User action
Check the disk unit status and execute the command again.
If the problem persists, refer to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
ssvsc0333
Explanation
The access path from the specified physical disk to the virtual storage pool is incorrect. Alternatively, the number of virtualization switches managed by the specified virtual storage pool and the number of paths for the physical disks do not match.
User action
Check the storage unit management window or the Design Sheet specifications to verify the WWN and LUN to be registered. Confirm that all the physical disks constituting the virtual disk are connected to the virtualization switches on the Relationship Management Window. Ensure that the physical disk can be seen from all the virtualization switches controlled by the specified virtual storage pool. Ensure that there is only one access path to a physical disk from each virtualization switch.
ssvsc0334
Explanation
There is no physical disk that meets the specified configuration conditions.
User action
Refresh the Virtual Storage Window (View and Create) and enter the configuration conditions again.
ssvsc0335
Explanation
Failed to add capacity to a virtual disk because an error occurred in the virtualization switch.
Parameters
0: VSC Engine error code
User action
Referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
ssvsc0336
Explanation
The specified physical disk is registered in a different virtual storage pool from the physical disk that constitutes the virtual disk.
User action
Specify a physical disk registered in the same virtual storage pool.
ssvsc0337
Explanation
You cannot delete the specified virtual disk because it is allocated to the virtual target.
User action
Unassign the virtual disk before deleting it.
ssvsc0338
Explanation
The information of the physical resources under management may be outdated.
Parameters
0: Physical disk information
User action
Refresh the physical resources management status to the latest one and register the physical disk again.
ssvsc0339
Explanation
The same virtualization switch group must control the virtual target and virtual disk.
User action
In the Virtual Storage Window (View and Create), check the virtualization switch of the virtual enclosure to which the virtual target belongs, and check the virtualization switch of the virtual storage pool containing the virtual disk. Specify a virtual target and virtual disk in the same virtualization switch.
ssvsc0340
Explanation
Either the specified virtual disk is in the process of migration or there is a migration backup.
Parameters
0: Virtual disk name
User action
In the Virtual Storage Window (Copy), confirm that the specified virtual disk is not in the process of migration or that there is no migration backup. Cancel migration or delete the backup, then execute the command again.
ssvsc0341
Explanation
The virtual disk can be allocated with only one host allocation number.
Parameters
0: Virtual disk name
User action
In the Virtual Storage Window (View and Create), check the host allocation number of virtual disks and allocate the virtual disk with the same host allocation number.
ssvsc0342
Explanation
A different virtual enclosure has the specified virtual target.
Parameters
0: Virtual disk name
User action
In the Virtual Storage Window (View and Create), check the virtual target name.
Specify a virtual target included in the same virtual enclosure.
ssvsc0343
Explanation
You cannot manipulate a virtual disk that is being copied.
Parameters
0: Virtual disk name
1: VSC Engine error code
User action
In the Virtual Storage Window (Copy), check the copying status.
ssvsc0344
Explanation
An error occurred in the virtualization switch.
Parameters
0: Virtual disk name
1: VSC Engine error code
User action
Check the disk unit status and repeat this operation.
If the problem persists, refer to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
ssvsc0345
Explanation
A virtual disk could not be allocated because an error occurred in a virtualization switch.
Parameters
0: VSC Engine error code
User action
Referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
ssvsc0346
Explanation
A virtual enclosure could not be created because an error occurred in a virtualization switch.
Parameters
0: VSC Engine error code
User action
Referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
ssvsc0347
Explanation
An error was detected during access from the virtualization switch to the physical disk.
Parameters
0: Physical disk information
1: VSC Engine error code
User action
Submit the request again.
If the problem persists, refer to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
ssvsc0348
Explanation
The specified physical disk is a non-supported disk unit or not a disk unit at all.
Parameters
0: Physical disk information
1: VSC Engine error code
User action
Use supported hardware for operation. For details, refer to "1.4.1 Supported hardware".
ssvsc0349
Explanation
The specified physical disk returned a busy status.
Parameters
0: Physical disk information
User action
Submit the request again.
ssvsc0350
Explanation
No more host allocation numbers can be created in the same virtual target.
Parameters
0: Virtual disk name
User action
In the Virtual Storage Window (View and Create), check the host allocation number of the virtual disk.
ssvsc0351
Explanation
An attempt was made to register a physical disk that has already been registered.
Parameters
0: Physical disk information
User action
Refresh the Virtual Storage Window (View and Create), verify the WWN and LUN, and execute the command again.
ssvsc0352
Explanation
The access path from the specified physical disk to the virtual storage pool is incorrect.
Or the number of virtualization switches managed by the specified virtual storage pool is not consistent with that of physical disk paths.
Parameters
0: Physical disk information
User action
Check the WWN and LUN of a physical disk to be registered on the management window of the storage device or on the specifications in design sheet.
Check on the related management window if the physical disks making up a virtual disk are connected to all the virtualization switches.
Set up so that the physical disks can be seen from all the virtualization switches managed by the specified virtual storage pool.
In addition, the number of access paths to the physical disks from each virtualization switch should be one.
ssvsc0353
Explanation
The specified physical disk could not be found from VSC Engine.
Parameters
0: Physical disk information
1: VSC Engine error code
User action
Check the storage unit management window or the Design Sheet specifications to verify the WWN and LUN to be registered.
In the related management windows, confirm that all the physical disks that constitutes the virtual disk are connected to virtualization switches.
ssvsc0354
Explanation
The specified physical disk is allocated to the real space of a virtual disk.
Parameters
0: Physical disk information
User action
In the Virtual Storage Window (View and Create), check the virtual disk allocated to the real space.
ssvsc0355
Explanation
The virtual disk that is most suitable considering the associated CM cannot be selected from the specified virtual storage pool.
User action
Perform one of the following actions in the Virtual Storage Window (View and Create):
To create a virtual disk in the specified virtual storage pool or add the capacity, do not use the <Candidate Selection> and <Automatic creation> button but directly select the physical disk.
Add physical disks corresponding to the configuration conditions to the specified virtual storage pool.
Specify another virtual storage pool.
ssvsc0356
Explanation
No more virtual disks can be created in the virtualization switch.
User action
Delete unnecessary virtual disks, and execute the command again.
For the number of virtual disks that can be created in a virtualization switch, refer to "Appendix D Limit Values".
ssvsc0357
Explanation
The maximum number of extents that can be created for the physical disks constituting a virtual disk has been exceeded.
Parameters
0: Number of units successfully created
1: Specified number of units
User action
Take either of the following procedures on the Virtual Storage Window (View and Create) screen.
If a virtual disk is automatically created or capacity is added:
Register physical disks corresponding to the configuration conditions in the virtual storage pool.
Specify another virtual storage pool.
If a virtual disk is selected and created or capacity is added by the user:
Refer to "A.2.3 Displaying the virtual storage pool" to check the number of unallocated extents of the "View and Create" screen and specify physical disks so that the number of extents may not exceed the maximum permissible number. For details, refer to "Appendix D Limit Values".
Execute "Candidate Selection".
Register physical disks in the virtual storage pool.
If capacity is added, there are cases where the number of extents has already reached the maximum permissible number. In this case, use Migration to expand the capacity.
ssvsc0358
Explanation
The virtual disk that is most suitable considering the associated CM cannot be selected from the specified virtual storage pool.
Parameters
0: Number of units successfully created
1: Specified number of units
User action
Perform one of the following actions in the Virtual Storage Window (View and Create):
To create a virtual disk in the specified virtual storage pool or add the capacity, do not use the <Candidate Selection> and <Automatic creation> button but directly select the physical disk.
Add physical disks corresponding to the configuration conditions to the specified virtual storage pool.
Specify another virtual storage pool.
ssvsc0359
Explanation
An error was detected during access from the virtualization switch to the physical disk.
Parameters
1: Number of units successfully created
2: Specified number of units
User action
Execute the command again.
If the problem persists, refer to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
ssvsc0360
Explanation
No response was issued from the selected physical disk.
Parameters
0: VSC Engine error code
1: Number of units successfully created
2: Specified number of units
User action
Execute the command again.
If the problem persists, refer to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
ssvsc0361
Explanation
A virtual disk could not be created because an error occurred in a virtualization switch.
Parameters
0: VSC Engine error code
1: Number of units successfully created
2: Specified number of units
User action
Referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
ssvsc0362
Explanation
An error occurred in the virtualization switch.
Parameters
0: VSC Engine error code
1: Number of units successfully created
2: Specified number of units
User action
Check the state of the disk unit and reenter the command.
If the problem persists, refer to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
ssvsc0363
Explanation
A virtual storage pool in which a physical disk is registered cannot be deleted.
Parameters
0: Number of units successfully deleted
1: Specified number of units
User action
In the Virtual Storage Window (View and Create), check for a physical disk in the virtual storage pool that is to be deleted.
If the virtual storage pool contains a physical disk, release the physical disk from the virtual storage pool before executing the command.
ssvsc0364
Explanation
The specified physical disk has already been allocated to the real space of a virtual disk.
Parameters
0: Number of units successfully released
1: Specified number of units
User action
Refresh the Virtual Storage Window (View and Create), select an unallocated physical disk, and execute the command again.
ssvsc0365
Explanation
A virtual enclosure in which a virtual target is registered cannot be deleted.
Parameters
0: Number of units successfully deleted
1: Specified number of units
User action
In the Virtual Storage Window (View and Create), check for a virtual target in the virtual enclosure that is to be deleted.
If the virtual enclosure contains a virtual target, delete the virtual target from the virtual enclosure before executing the command.
ssvsc0366
Explanation
A virtual target to which a virtual disk has been allocated cannot be deleted.
Parameters
0: Number of units successfully deleted
1: Specified number of units
User action
Unassign the virtual disk before deleting the virtual target.
ssvsc0367
Explanation
A virtual target could not be deleted because an error occurred in a virtualization switch.
Parameters
0: VSC Engine error code
1: Number of units successfully deleted
2: Specified number of units
User action
Referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
ssvsc0368
Explanation
You cannot operate a virtual disk that is subject to a copy operation.
Parameters
0: VSC Engine error code
1: Number of units successfully deleted
2: Specified number of units
User action
Check the copy status in the Virtual Storage Window (Copy). Alternatively, use the getsession command to check the copy status.
ssvsc0369
Explanation
An error occurred in the virtualization switch.
Parameters
0: VSC Engine error code
1: Number of units successfully deleted
2: Specified number of units
User action
Referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
ssvsc0370
Explanation
The specified virtual disk cannot be deleted because it is allocated to a virtual target.
Parameters
0: Number of units successfully deleted
1: Specified number of units
User action
Unassign the virtual disk before deleting it.
ssvsc0371
Explanation
An error occurred in the virtualization switch.
Parameters
0: VSC Engine error code
1: Number of units successfully deleted
2: Specified number of units
User action
Check the state of the disk unit and reenter the command.
If the problem persists, refer to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
ssvsc0372
Explanation
An error was detected during access to the physical disk from the virtualization switch.
Parameters
0: VSC Engine error code
1: Physical disk information
2: Number of units successfully created
3: Specified number of units
User action
Execute the command again.
If the problem persists, refer to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
ssvsc0373
Explanation
The specified physical disk is an unsupported disk unit or it is not a disk unit.
Parameters
0: VSC Engine error code
1: Physical disk information
2: Number of units successfully created
3: Specified number of units
User action
Use supported hardware for operation. For details, refer to "1.4.1 Supported hardware".
ssvsc0374
Explanation
An error occurred in the virtualization switch.
Parameters
0: VSC Engine error code
1: Physical disk information
2: Number of units successfully created
3: Specified number of units
User action
Confirm that the status of the disk unit is normal, then execute the command again.
If the problem persists, refer to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
ssvsc0375
Explanation
Batch conversion failed because an error occurred in a virtualization switch.
Parameters
0: VSC Engine error code
1: Physical disk information
2: Number of units successfully created
3: Specified number of units
User action
Referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
ssvsc0376
Explanation
No more virtual targets can be created in the same virtual enclosure.
User action
Delete unnecessary virtual targets, and execute the command again. For the number of virtual targets that can be created in a virtualization switch, refer to "Appendix D Limit Values".
ssvsc0377
Explanation
No more virtual targets can be created in the virtualization switch.
User action
Delete unnecessary virtual targets, then execute the command again. For the number of virtual targets that can be created in a virtualization switch, refer to "Appendix D Limit Values".
ssvsc0378
Explanation
No more host allocation numbers can be created in the same target.
User action
Delete unnecessary host allocation numbers, then execute the command again. For the number of host allocation numbers that can be created in a virtualization switch, refer to "Appendix D Limit Values".
ssvsc0379
Explanation
Each host allocation number in the same virtual target must be unique.
User action
Check the host allocation numbers of virtual disks in the Virtual Storage Window (View and Create). Specify a host allocation number that is unique within the virtual target.
ssvsc0380
Explanation
The access path from the specified physical disk to the virtual storage pool is incorrect.
Alternatively, the number of virtualization switches managed by the specified virtual storage pool does not match the number of paths for the physical disks.
Parameters
0: Physical disk information
1: Number of units successfully created
2: Specified number of units
User action
Check the storage unit management window or the Design Sheet specifications to verify the WWN and LUN of the physical disk to be registered.
Confirm that all the physical disks constituting the virtual disk are connected to the virtualization switches on the Relationship Management Window. Ensure that the physical disk can be seen from all the virtualization switches controlled by the specified virtual storage pool. Ensure that there is only one access path to a physical disk from individual virtualization switch.
ssvsc0381
Explanation
The specified physical disk could not be found from VSC Engine.
Parameters
0: VSC Engine error code
1: Physical disk information
2: Number of units successfully created
3: Specified number of units
User action
Check the storage unit management window or the Design Sheet specifications to verify the WWN and LUN to be registered.
In the related management windows, confirm that the physical disk is connected to all virtualization switches associated with the virtual storage used.
ssvsc0382
Explanation
Information on the physical resources under management is probably out of date.
Parameters
0: Physical disk information
1: Number of units successfully created
2: Specified number of units
User action
Update the physical resource management status, then register the physical disk again.
ssvsc0383
Explanation
An attempt was made to register an already registered physical disk.
Parameters
0: Name of the physical disk that could not be registered
1: Number of units successfully created
2: Specified number of units
User action
Verify the WWN and LUN in the Virtual Storage Window (View and Create).
ssvsc0384
Explanation
Although the physical disk is registered in the virtual storage pool, the values stored in VSC Manager are used as the name of storage unit and the LUNV number. The specified name of storage unit and LUNV number are not used.
User action
Confirm that the physical disk is not Fujitsu’s.
ssvsc0385
Explanation
A VS900 management area could not be created because no physical disk connected to the specified CA port had been registered.
User action
Register a physical disk connected to the specified CA port.
ssvsc0386
Explanation
Creating a VS900 management area failed because there is already an existing VS900 management area for the specified CA port.
User action
In the "List of VS900 Management Areas" window, confirm that the VS900 management area of the specified CA port already exists.
ssvsc0387
Explanation
A VS900 management area could not be created because the physical disk connected to the specified CA port does not have sufficient free space to accommodate the VS900 management area.
User action
Perform one of the following operations in the Virtual Storage Window (View and Create) until sufficient free space for the VS900 management area can be secured:
Increase the size of the physical disk connected to the specified CA port.
Delete a virtual disk to which the physical disk connected to the specified CA port is allocated.
ssvsc0388
Explanation
A VS900 management area could not be created because an error occurred in a virtualization switch.
Parameters
0: VSC Engine error code
User action
Referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
ssvsc0389
Explanation
Deleting the VS900 management area of the specified CA port failed because it was not found.
User action
In the "List of VS900 Management Areas" window, confirm that the VS900 management area of the specified CA port does not exist.
ssvsc0390
Explanation
The VS900 management area of the specified CA port could not be deleted because the session using the VS900 management area cannot be reallocated to another VS900 management area.
Parameters
0: ID of the session in use
If multiple sessions are in use, they are all displayed delimited by a comma ",".
User action
Terminate the target session(s), then execute the command again.
ssvsc0391
Explanation
An attempt was made to relocate the session using the VS900 management area of the specified CA port to another VS900 management area, but no alternative VS900 management area was found. Therefore, the VS900 management area could not be deleted.
Parameters
0: ID of the session in use
If multiple sessions are in use, they are all displayed delimited by a comma ",".
User action
Create another VS900 management area in the same switch group as that of the specified VS900 management area, then execute the command again.
If no other VS900 management area can be created, terminate the target session(s), then execute the command again.
ssvsc0392
Explanation
An attempt was made to relocate the session using the VS900 management area of the specified CA port to another VS900 management area, but the attempt failed. Therefore, the VS900 management area could not be deleted.
Parameters
0: ID of a relocatable session. If multiple sessions are in use, they are all displayed delimited by a comma ",".
1: ID of a non-relocatable session. If multiple sessions are in use, they are all displayed delimited by a comma ",".
User action
Perform one of the following operations, and execute the command again:
Terminate the non-relocatable session(s).
Create another VS900 management area in the same switch group as that of the specified VS900 management area.
If no other VS900 management area can be created, terminate the relocatable session(s).
ssvsc0393
Explanation
The VS900 management area could not be deleted because an error occurred in a virtualization switch.
Parameters
0: VSC Engine error code
User action
Referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
ssvsc0394
Explanation
The specified physical disk could not be released because it had been allocated to a VS900 management area.
Parameters
0: Physical disk information
User action
Delete the VS900 management area to which the disk is allocated, then execute the command again.
ssvsc0395
Explanation
The specified physical disk could not be released because it had been allocated to a VS900 management area.
Parameters
0: Number of units successfully released
1: Specified number of units
User action
Delete the VS900 management area to which the disk is allocated, then execute the command again.
ssvsc0399
Explanation
The specified physical disk is excluded from support. Therefore, it cannot be registered.
User action
Check the following information on a physical disk in which an error occurred.
Check if the physical disk capacity exceeds the maximum value defined in VSC Engine.
After correcting the above mentioned matter, update the management status of the physical resource to the latest status and then re-register the physical disk.
ssvsc0400
Explanation
A virtual disk having a backup cannot be migrated.
User action
Delete the backup disk in the Virtual Storage Window (Copy), then execute migration processing again.
ssvsc0401
Explanation
The specified session has already ended.
Otherwise, the specified session ID is incorrect.
User action
Confirm that the target session ID exists in the Virtual Storage Window (Copy).
Use the getsession command to check the session ID.
ssvsc0402
Explanation
The virtual storage pool that includes the virtual disk to be migrated and the destination virtual storage pool are not controlled by the same virtualization switch group.
User action
Specify a virtual storage pool associated with the same virtualization switch group as that of the virtual storage pool to which the virtual disk to be migrated belongs.
ssvsc0403
Explanation
The specified virtualization switch does not form a redundant configuration with the following virtualization switch:
The virtualization switch associated with the virtual storage pool to which the virtual disk to be migrated belongs
User action
Specify the virtualization switch associated with the virtual storage pool to which the virtual disk to be migrated belongs.
ssvsc0404
Explanation
The replication cannot be carried out in the same virtual disk.
User action
Specify a copy destination virtual disk that is different from the copy source virtual disk.
ssvsc0405
Explanation
The specified virtualization switch does not form a redundant configuration with the following virtualization switch:
The virtualization switch associated with the virtual storage pool to which the virtual disk to be replicated belongs
User action
Specify the virtualization switch associated with the virtual storage pool to which the virtual disk to be replicated belongs.
ssvsc0406
Explanation
No more copy processing can be started.
Parameters
0: VSC Engine error code
User action
Cancel copying in the Virtual Storage Window (Copy), or use the cancelrep command to cancel replication. For the maximum number of concurrent copy processing, refer to "Appendix D Limit Values".
ssvsc0407
Explanation
The specified session ID is not for migration. Therefore, migration can neither be canceled nor terminated.
User action
Check the copy status in the Virtual Storage Window (Copy). Alternatively, use the getsession command to check the session type.
ssvsc0408
Explanation
The specified session ID is not for replication. Therefore, replication can neither be canceled nor terminated.
User action
Check the copy status in the Virtual Storage Window (Copy). Alternatively, use the getsession command to check the session type.
ssvsc0409
Explanation
Migration or replication is in progress with the session of the specified session ID, so the session cannot be terminated.
User action
Check the copy status in the Virtual Storage Window (Copy), then execute the command again when the status changes to "synchronized".
Alternatively, use the getsession command to check the copy status, then execute the command again when "Phase" changes to "equivalent".
ssvsc0410
Explanation
There is no migration backup for the virtual disk.
User action
Confirm that the target virtual disk has a backup disk in the Virtual Storage Window (Copy).
ssvsc0411
Explanation
The specified virtual disk is already in the process of migration.
User action
Check the copy status in the Virtual Storage Window (Copy). Alternatively, use the
getsession command to check the copying status.
If the following conditions are all met, it is likely that an internal error occurred:
The Virtual Storage Window (copy) does not display a session for the specified virtual disk.
The migration backup disk list window does not display the specified virtual disk.
The detailed information on already allocated physical disks displayed in the Virtual Storage Window (View and Create) includes the specified virtual disk.
If the getsession command indicates that the relevant copy session is present:
Refresh the Virtual Storage Window (Copy). If the problem persists, close the Virtual Storage Window (Copy) and open it again. If the problem still persists, restart the admin client program.
If the getsession command indicates that the relevant copy session does not exist, or if the action taken as described in above fails to solve the problem:
Refer to "6.3 Collecting Data", collect the necessary data for troubleshooting, then restart the Manager. Also, contact your Fujitsu engineer (CE or SE).
ssvsc0412
Explanation
The specified virtual disk is already in the process of replication.
User action
Check the copy status in the Virtual Storage Window (Copy). Alternatively, use the getsession command to check the copying status.
ssvsc0413
Explanation
Failed to get session information.
User action
Check the status information for the virtualization switch in the Virtual Storage Window (Maintenance). If the status information indicates an error (abnormal), check the virtualization switch or network for errors.
Alternatively, use the getvsw command to check the status information for the virtualization switch. If the status information indicates an error (abnormal), check the virtualization switch or network for errors.
ssvsc0414
Explanation
Migration could not be started because an error occurred in a virtualization switch.
Parameters
0: VSC Engine error code
User action
Referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
ssvsc0415
Explanation
Migration could not be changed because an error occurred in a virtualization switch.
Parameters
0: VSC Engine error code
User action
Referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
ssvsc0416
Explanation
Migration could not be stopped because an error occurred in a virtualization switch.
Parameters
0: VSC Engine error code
User action
Referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
ssvsc0417
Explanation
A migration backup could not be restored because an error occurred in a virtualization switch.
Parameters
0: VSC Engine error code
User action
Referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
ssvsc0418
Explanation
A migration backup could not be deleted because an error occurred in a virtualization switch.
Parameters
0: VSC Engine error code
User action
Referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
ssvsc0419
Explanation
Replication could not be started because an error occurred in a virtualization switch.
Parameters
0: VSC Engine error code
User action
Referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
ssvsc0420
Explanation
Replication could not be isolated because an error occurred in a virtualization switch.
Parameters
0: VSC Engine error code
User action
If the VSC Engine error code is 0x3112, re-create the virtualization switch configuration information and then perform replication isolation again. If this does not solve the problem, referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
ssvsc0421
Explanation
Replication could not be stopped because an error occurred in a virtualization switch.
Parameters
0: VSC Engine error code
User action
Referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
ssvsc0422
Explanation
The specified name of the destination virtual disk is incorrect.
User action
Check the virtual disk in the Virtual Storage Window (View and Create), then specify a valid virtual disk name.
ssvsc0423
Explanation
Session status information could not be obtained because an error occurred in a virtualization switch.
Parameters
0: VSC Engine error code
User action
Referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
ssvsc0424
Explanation
The virtual storage pool that includes the virtual disk to be replicated and the destination virtual storage pool are not controlled by the same virtualization switch group.
Parameters
0: VSC Engine error code
User action
Specify a virtual storage pool associated with the same virtualization switch group as that of the virtual storage pool to which the virtual disk to be replicated belongs.
ssvsc0425
Explanation
Migration could not be automatically changed because an error occurred in a virtualization switch.
Parameters
0: VSC Engine error code
1: A session ID.
User action
Referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
ssvsc0426
Explanation
If migration is executed in a mode that does not retain a migration backup disk, the destination physical disk must have the same capacity as the source physical disk.
User action
Execute migration with the capacity of the destination physical disk equal to that of the source physical disk.
ssvsc0427
Explanation
An attempt to read the entire copy history failed.
User action
Check whether the copy history file is damaged.
ssvsc0428
Explanation
An attempt to read the copy history failed.
Parameters
0: Name of the copy history file
User action
Check whether the copy history file is damaged.
ssvsc0429
Explanation
Replication could not be stopped.
User action
Confirm that:
The switch status in the Maintenance window is normal.
The Engine status is active.
If the problem persists, refer to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
ssvsc0430
Explanation
Migration could not be stopped.
User action
Confirm that:
The switch status in the Maintenance window is normal.
The Engine status is active.
If the problem persists, refer to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
ssvsc0431
Explanation
The virtual disk to be copied has not been allocated to a virtual target.
User action
Allocate the target virtual disk to a virtual target.
ssvsc0432
Explanation
Replication cannot be carried out because the capacity of the virtual disk specified as the replication destination is smaller than that of the virtual disk of the replication source.
User action
Specify, as the replication destination, a virtual disk with a capacity larger than that of the replication source virtual disk.
ssvsc0433
Explanation
The encrypted volumes cannot be copied to the non-encrypted volumes.
User action
Specify a volume with the encryption attribute as the virtual disk of the replication destination. Alternatively, specify the "f" option and re-execute.
ssvsc0434
Explanation
Replication from the encrypted volumes to the non-encrypted volumes was carried out.
User action
If copying from an encrypted volume to a non-encrypted volume is not permitted, terminate the replication session.
ssvsc0435
Explanation
The session with the specified ID is being copied, and so cannot be terminated.
User action
Check the copy status on the Virtual Storage Window (Copy), and re-execute the command when it has changed to the equivalency maintain status.
Alternatively, check the copy status using the getssession command and re-execute the command when the phase has become equivalent.
ssvsc0436
Explanation
An error occurred with a virtualization switch, and migration could not be stopped.
Parameters
0: VSC Engine error code
1: Number of units successfully processed
2: Number of units specified
User action
Referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
ssvsc0437
Explanation
Migration could not be stopped.
Parameters
0: Number of units successfully processed
1: Number of units specified
User action
Confirm that:
the switch status on the maintenance window is normal
the engine is in the activation status
If the problem persists, by referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, and contact your Fujitsu engineer (CE or SE).
ssvsc0438
Explanation
Session information could not be obtained.
Parameters
0: Number of units successfully processed
1: Number of units specified
User action
Check the status information of the virtual switch on the Virtual Storage Window (Maintenance). If the status shows abnormal, check for errors in the virtual switch or the network.
Alternatively, check the status information of the virtualization switch using the getvsw command. If the status shows abnormal, check for errors in the virtual switch or the network.
ssvsc0439
Explanation
The specified session has already ended. Alternatively, an incorrect session ID has been specified.
Parameters
0: Number of units successfully processed
1: Number of units specified
User action
Check if the session ID exists on the Virtual Storage Window (Copy).
Check the session ID using the getsession command.
ssvsc0440
Explanation
Replication could not be stopped.
Parameters
0: Number of units successfully processed
1: Number of units specified
User action
Confirm that:
the switch status on the maintenance window shows normal
the engine is in the activation status
If the problem persists, by referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, and contact your Fujitsu engineer (CE or SE).
ssvsc0441
Explanation
An error occurred with a virtualization switch, and replication could not be stopped.
Parameters
0: VSC Engine error code
1: Number of units successfully processed
2: Number of units specified
User action
Referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
ssvsc0442
Explanation
An error occurred with a virtualization switch, and migration could not be switched.
Parameters
0: VSC Engine error code
1: Number of units successfully processed
2: Number of units specified
User action
Referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
ssvsc0443
Explanation
The session with the specified ID is not in the equivalency maintain status, and so cannot be ended.
Parameters
0: Number of units successfully processed
1: Number of units specified
User action
Check the copy status on the Virtual Storage Window (Copy), and re-execute the command when it has changed to the equivalency maintain status.
Alternatively, check the copy status using the getssession command and re-execute the command when the phase has become equivalent.
ssvsc0444
Explanation
An error occurred with a virtualization switch, and the migration backup could not be restored.
Parameters
0: VSC Engine error code
1: Number of units successfully processed
2: Number of units specified
User action
Referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
ssvsc0445
Explanation
The migration backup for the virtual disk cannot be found.
Parameters
0: Number of units successfully processed
1: Number of units specified
User action
Ensure that a backup disk exists for the virtual disk by checking the Virtual Storage Window (Copy).
ssvsc0446
Explanation
An error occurred with a virtualization switch, and the migration backup could not be deleted.
Parameters
0: VSC Engine error code
1: Number of units successfully processed
2: Number of units specified
User action
Referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
ssvsc0447
Explanation
The specified virtual disk has reached the maximum number of copies that can be executed. Therefore, no more copies can be made.
Parameters
0: VSC Engine error code
User action
Stop replication of the specified virtual disk of the copy source on the Virtual Storage Window (Copy) or using the cancelrep command.
For the maximum number of copies, refer to "Appendix D Limit Values".
ssvsc0448
Explanation
The specified backup disk cannot be restored because it has already been restored. This backup disk can only be deleted.
User action
Use the Virtual Storage window (Copy) to delete the backup disk for the target virtual disk.
ssvsc0449
Explanation
The specified backup disk cannot be restored because it has already been restored. This backup disk can only be deleted.
Parameters
0: Number of units successfully created
1: Specified number of units
User action
Use the Virtual Storage window (Copy) to delete the backup disk for the target virtual disk.
ssvsc0500
Explanation
Failed to communicate with the virtualization switch because the host name of the virtualization switch is invalid.
Parameters
0: Host name of the virtualization switch used for communication
For virtualization switches other than the VS900 Model 200, the name of the virtualization switch is displayed as “virtualization switch name (host name)”.
User action
Solaris OS/Linux OS
Confirm that:
The host name of the virtualization switch is registered in the /etc/hosts file.
The correct IP address of Ethernet port for virtualization control of the virtualization switch is entered in the /etc/hosts file.
Windows
Confirm that:
The host name of the virtualization switch is registered in the %SystemRoot%\system32\drivers\etc\hosts file.
The correct IP address of Ethernet port for virtualization control of the virtualization switch is entered in the %SystemRoot%\system32\drivers\etc\hosts file.
ssvsc0501
Explanation
No more virtualization switches can be registered.
User action
Delete unnecessary virtualization switches, then execute the command again. For the number of virtualization switches that can be registered, refer to "Appendix D Limit Values".
ssvsc0502
Explanation
Multiple virtualization switches cannot be registered with the same host name.
User action
Check the registered virtualization switch information in the Virtual Storage Window (Maintenance). Alternatively, use the getvsw command to check the registered host names of virtualization switches.
ssvsc0503
Explanation
The virtualization switch is in an error status.
Parameters
0: Name of the virtualization switch in error status
For virtualization switches other than the VS900 Model 200, the name of the virtualization switch is displayed as “virtualization switch name (host name)”.
User action
Verify the status of the target virtualization switch.
If the problem persists, refer to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
ssvsc0504
Explanation
There is virtual configuration information for the virtualization switch.
User action
If you want to proceed with device exchange, click the <Delete> button.
If you do not want to proceed with device exchange, delete all resources of virtual storage related to the specified device and try again.
ssvsc0505
Explanation
The specified information does not exist.
User action
Verify the configuration information in the Virtual Storage Window (View and Create).
ssvsc0506
Explanation
The virtualization switch is not initialized.
User action
Use the vscecreateconfigfile command of VSC Engine to initialize the virtualization switch.
ssvsc0507
Explanation
The VSC Engine trace level could not be set because an error occurred in a virtualization switch.
Parameters
0: VSC Engine error code
User action
Referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
ssvsc0508
Explanation
The configuration information in the virtualization switch could not be re-created because an error occurred in a virtualization switch.
Parameters
0: VSC Engine error code
User action
Referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
ssvsc0509
Explanation
VSC Engine could not be stopped because an error occurred in a virtualization switch.
User action
Referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
ssvsc0510
Explanation
The virtual enclosure BoxID could not be changed because an error occurred in a virtualization switch.
Parameters
0: VSC Engine error code
User action
Referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
ssvsc0511
Explanation
The virtualization switch is not registered as a device to be managed.
Parameters
0: Host name of the virtualization switch
For virtualization switches other than the VS900 Model 200, the name of the virtualization switch is displayed as “virtualization switch name (host name)”.
User action
On the ESC Resource Management Window, search for and add the device to be managed. If the problem persists, refer to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
ssvsc0512
Explanation
The managed device information for the virtualization switch is incorrect.
Parameters
0: Host name of the virtualization switch
For virtualization switches other than the VS900 Model 200, the name of the virtualization switch is displayed as “virtualization switch name (host name)”.
User action
On the Resource Management Window, perform the following procedures:
Delete the device to be managed.
Select Delete in the Replace Device message.
Add and delete the device to be managed.
If the problem persists, refer to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
ssvsc0513
Explanation
Information could not be obtained because an error was generated at the virtualization switch.
Parameters
0: VSC Engine error code
User action
Refer to "6.3 Collecting Data" and collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
ssvsc0514
Explanation
Information could not be obtained because an error was generated at the virtualization switch.
Parameters
0: VSC Engine error code
1: Host name of Virtualization switch
For virtualization switches other than the VS900 Model 200, the name of the virtualization switch is displayed as “virtualization switch name (host name)”.
User action
Refer to "6.3 Collecting Data" and collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
ssvsc0515
Explanation
Virtual configuration information for the virtualization switch already exists.
Parameters
0: Virtualization switch name (host name)
User action
To replace the virtualization switch, use the Virtual Storage window (Maintenance) to disable the virtualization switch, and then execute the processing again.
To delete the virtualization switch, delete all of the resources for the virtual storage device associated with the specified virtualization switch, and then execute the processing again.
ssvsc0516
Explanation
The host name of the virtualization switch could not be acquired.
User action
If the user has attempted to use the virtualization function start settings to register a switch that has an application function other than the VS900 series, no action is required because only VS900 virtualization switches are supported. These switches can still be used as normal switches without making any changes.
If the user has attempted to use the virtualization switch function start settings to register a VS900 series virtual switch, check the settings for the virtualization switch. If the problem persists, collect the data necessary for troubleshooting and contact a Fujitsu engineer (CE or SE).
Refer to "6.3 Collecting Data".
ssvsc0517
Explanation
The virtualization blade may have been inserted into the wrong slot.
Parameters
0: Virtualization switch name (host name)
User action
Check the insertion position for the virtualization blade.
Otherwise, update the management status of physical resources to the latest status, and then execute the processing again
If the problem persists, collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
Refer to "6.3 Collecting Data".
ssvsc0518
Explanation
The user has attempted to either stop or disable the virtualization switch function for a virtualization blade, but the serial number for the virtualization blade that has been inserted in the slot does not match the registered information.
Parameters
0: Virtualization switch name (host name)
User action
Check the slot position and settings for the virtualization blade.
Otherwise, update the management status of physical resources to the latest status, and then execute the processing again
If the problem persists, collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
Refer to "6.3 Collecting Data".
ssvsc0519
Explanation
Virtual configuration information for the virtualization switch already exists.
User action
To replace the virtualization switch, use the Virtual Storage window (Maintenance) to disable the virtualization switch, and then execute the processing again.
To delete the virtualization switch, delete all of the resources for the virtual storage device associated with the specified virtualization switch, and then execute the processing again.
ssvsc0521
Explanation
The login name or password is incorrect.
Parameters
0: IP address of Ethernet port for virtualization control of the connection destination virtualization switch
User action
Check the login name and password for the connection destination.
ssvsc0522
Explanation
Failed in the connection to the virtualization switch.
Parameters
0: IP address of Ethernet port for virtualization control of the connection destination virtualization switch
User action
Check the following points, and then repeat the operation that resulted in issue of this error message:
・Has the virtualization switch registered in ETERNUS SF Storage Cruiser been powered up?
・Has the IP address of the virtualization switch registered in ETERNUS SF Storage Cruiser been changed?
・Is there a fault in the network environment?
ssvsc0523
Explanation
A timeout occurred during connection to the virtualization switch.
Parameters
0: IP address of Ethernet port for virtualization control of the connection destination virtualization switch
User action
Check the following points, and then repeat the operation that resulted in issue of this error message:
・Has the virtualization switch registered in ETERNUS SF Storage Cruiser been powered up?
・Is there a fault in the network environment?
ssvsc0524
Explanation
A communication fault occurred during connection to the virtualization switch.
Parameters
0: IP address of Ethernet port for virtualization control of the connection destination virtualization switch
User action
Check if there is a fault in the network environment, and then repeat the operation that resulted in issue of this error message.
If the problem persists, refer to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
ssvsc0525
Explanation
The connection to the virtualization switch was refused.
There may already be two names logged in as admin users to the virtualization switch.
Parameters
0: IP address of Ethernet port for virtualization control of the connection destination virtualization switch
User action
Check if login restrictions have been set for the connection destination IP address of Ethernet port for virtualization control.
If you are logged into the virtualization switch as an admin user, log out and then repeat the operation that resulted in issue of this error.
ssvsc0526
Explanation
An error occurred during acquisition of the firmware information.
User action
Refer to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
ssvsc0527
Explanation
License information acquisition failed because an error occurred during acquisition of the firmware information.
User action
Refer to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
ssvsc0528
Explanation
Connection to the FTP server failed.
Parameters
0: IP address of the connection destination FTP server
User action
Check the following points, and then repeat the operation that resulted in issue of this error message:
・Is the IP address of the specified FTP server correct?
・Is the FTP server activated?
ssvsc0529
Explanation
Login to the FTP server failed.
Parameters
0: IP address of the connection destination FTP server
User action
Check the following points, and then repeat the operation that resulted in issue of this error message:
・Are the specified user name and password correct?
・Are the specified user name and password set as an FTP server account?
・Do the FTP server access settings prohibit to access to the FTP server by the specified user?
・Do the FTP server access settings prohibit to access to the FTP server by the IP address of Ethernet port for virtualization control of the virtualization switch?
ssvsc0530
Explanation
A timeout occurred during connection to the FTP server.
Parameters
0: IP address of the connection destination FTP server
User action
Check the following points, and then repeat the operation that resulted in issue of this error message:
・Is the FTP server activated?
・Is there a fault in the network environment?
ssvsc0531
Explanation
A communication error occurred during connection to the FTP server.
Parameters
0: IP address of the connection destination FTP server
User action
Check the following points, and then repeat the operation that resulted in issue of this error message:
・Is the FTP server activated?
・Is there a fault in the network environment?
ssvsc0532
Explanation
The specified directory could not be found.
Parameters
0: Specified directory
User action
Check the following points, and then repeat the operation that resulted in issue of this error message:
・Is the specified directory correct?
・Does the specified directory exist in the connection destination FTP server?
ssvsc0533
Explanation
The value entered for backup of the VSC Engine environment settings is incorrect.
User action
Check the following points, and then repeat backup of the VSC Engine environment settings:
・Is the FTP server activated?
・Is the FTP server IP address correct?
・Are the FTP server login name and password correct?
・Do the FTP server access settings prohibit to access to the FTP server by the specified user name?
・Do the FTP server access settings prohibit to access to the FTP server by the IP address of Ethernet port for virtualization control of the virtualization switch?
・Does the backup directory for the VSC Engine environment settings exist?
・Is writing to the backup directory for the VSC Engine environment settings permitted?
・Is there enough free space in the backup directory for the VSC Engine environment settings?
ssvsc0534
Explanation
The VSC Engine configuration information could not be backed up because the maximum number of backup files stored under the specified directory has been exceeded.
User action
Delete backup files under the specified directory, or change the backup destination directory.
ssvsc0535
Explanation
The information required for firmware installation is incorrect.
Parameters
0: Type of firmware being installed (FOS, SAS, VSC Engine)
User action
The information required for installation of the firmware might have changed during firmware installation. Check the following information and then install the firmware again:
・Storage directory of the FOS firmware, and the stored FOS firmware
・Storage directory of the SAS firmware, and the stored SAS firmware
・Storage directory of the VSC Engine firmware, and the stored VSC Engine firmware
・FOS configuration filename being backed up
・Backup directory of the VSC Engine configuration file
ssvsc0536
Explanation
An incorrect value was entered for backup of the FOS settings information.
User action
Check the following points, and then execute backup of the FOS settings information again.
・Is the FTP server activated?
・Is the IP address of the FTP server correct?
・Are the FTP server login name and password correct?
・Does the FTP server configuration prohibit access by the specified user name?
・Does the FTP server configuration prohibit access by the IP address of Ethernet port for virtualization control of the virtualization switch?
・Does the backup directory for the VSC configuration file exist?
・Is writing to the backup directory for the VSC configuration file permitted?
・Is there enough space in the backup directory for the VSC settings information?
ssvsc0537
Explanation
An incorrect value was entered for restoration of the VSC Engine environment settings.
User action
Check the following points, and then execute restoration of the VSC Engine environment settings again:.
・Is the FTP server activated?
・Is the IP address of the FTP server correct?
・Are the FTP server login name and password correct?
・Does the FTP server configuration prohibit access by the specified user name?
・Does the FTP server configuration prohibit access by the IP address of Ethernet port for virtualization control of the virtualization switch?
・Does the VSC Engine configuration file being restored exist in the specified directory?
ssvsc0538
Explanation
Backup file generation failed for the VSC Engine environment settings.
Parameters
0: Filename
User action
Check whether the file exists.
Check whether writing to the directory is permitted.
A backup file that does not have the host name attached to the start of the filename may be generated. Such a file is not a valid backup file of the VSC Engine environment settings. Therefore, do not use such a file to restore the VSC Engine environment settings.
ssvsc0539
Explanation
The FOS firmware version is not supported.
Parameters
0: FOS firmware version
User action
Check the FOS firmware version.
If the FOS firmware version is not supported, then install one supported by the virtualization switch.
ssvsc0540
Explanation
Firmware installation is in progress.
User action
Wait until installation of the firmware ends, then try again.
ssvsc0541
Explanation
Execution of FOS and VSC Engine command failed.
Parameters
0: Name of executed command
User action
If command is vscerestore:
Restore the VSC Engine configuration, then reactivate the virtualization switch in order to apply the VSC Engine configuration to it.
If command is not vscerestore:
Re-execute the operation for which this error message was displayed.
If recovery is not possible after the above action, refer to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
ssvsc0542
Explanation
The virtualization function settings failed because an incompatibility was detected in the VSC Engine status.
User action
Refresh the virtual storage window (Maintenance window).
Then, configure the virtualization function again.
ssvsc0543
Explanation
The following virtualization function settings could not be set because the VSC Engine is operating:
・Virtualization function settings for the local switch
・Virtualization function settings for the redundancy switch
・Port number setting
User action
Execute the following procedures:
On the virtual storage window (Maintenance window), click <Enable> and set the logical status of the virtualization switch to "Enabled".
On the virtual storage window (Maintenance window), click <Stop> to stop the VSC Engine.
On the virtual storage window (Maintenance window), click <Disable> and set the logical status of the virtualization switch to "Disabled".
Configure the virtualization function again.
ssvsc0544
Explanation
Completion confirmation processing for the firmware installation terminated abnormally.
User action
Reactivate the virtualization switch, and then check the firmware version number.
ssvsc0546
Explanation
An incorrect value was entered for restoration of the FOS settings information.
User action
Check the following points, and then execute restoration of the FOS settings information again:.
・Is the FTP server activated?
・Is the IP address of the FTP server correct?
・Are the FTP server login name and password correct?
・Does the FTP server configuration prohibit access by the specified user name?
・Does the FTP server configuration prohibit access by the IP address of Ethernet port for virtualization control of the virtualization switch?
・Does the FOS configuration file being restored exist in the specified directory?
ssvsc0548
Explanation
The SSH key settings failed.
User action
Check the status of the targeted switch on the ESC resource management window, then check for a password error. If there was a password error, then update the ESC registration information (for details, refer to the "ETERNUS SF Storage Cruiser User's Guide", section "Environment Configuration" > "Fibre Channel Switch" > "SN200 (Brocade) Fibre Channel switch" > "Problem handling (FAQ)", item "A warning for a device is displayed (in yellow)").
Then, take the following actions:
Firmware installation
Restore the VSC Engine configuration, then reactivate the virtualization switch in order to apply the VSC Engine configuration to it.
Virtualization function settings
Wait a few moments, then execute the virtualization function settings again.
Restoration of VSC Engine configuration
Restore the VSC Engine configuration, then reactivate the virtualization switch in order to apply the VSC Engine configuration to it.
If recovery is not possible after the above action, then collect the data needed for troubleshooting as explained in "6.3 Collecting Data",a contact your Fujitsu engineer (CE or SE).
ssvsc0549
Explanation
An incorrect value was entered in the basic settings for the storage virtualization function.
User action
Check for incorrect values entered in the basic settings of the storage virtualization function.
ssvsc0550
Explanation
The file name is not specified.
User action
Check whether the file name was specified in the entered values.
ssvsc0551
Explanation
A folder with the specified name already exists in the FTP server.
User action
Check the following points, and then repeat the operation for which this error message was issued:
・Is the entered value correct?
・Is a directory on the FTP server the same as the file name?
ssvsc0552
Explanation
Log information could not be collected.
Parameters
0: Module for which collection not possible (CP, CP0, CP1, VSCEngine)
User action
Check the following points, and then execute collection of log information again:
・Is the FTP server activated?
・Is the IP address of the FTP server correct?
・Are the FTP server login name and password correct?
・Does the FTP server configuration prohibit access by the specified user name?
・Does the FTP server configuration prohibit access by the IP address of Ethernet port for virtualization control of the virtualization switch?
・Does the log information backup destination directory exist?
・Is writing to the log information backup destination directory permitted?
・Is there enough space in the log information backup destination directory?
ssvsc0554
Explanation
VSC log information could not be collected to the specified directory because it is incorrect. The log information may have been collected to the FTP server home directory.
Parameters
0: Log information storage directory
User action
Check whether the log information was collected to the FTP server home directory.
If it was not, then check the value entered as the log collection directory and try again.
ssvsc0555
Explanation
The firmware update failed.
Parameters
0: Firmware type for which firmware update was executed (FOS, SAS, VSC Engine)
User action
If Firmware = FOS
Execute installation of the FOS, SAS, and VSC Engine firmware again.
If Firmware = SAS
Execute installation of the SAS and VSC Engine firmware again.
If Firmware = VSCEngine
Execute installation of the VSC Engine firmware again.
If recovery is not possible after the above action, then collect the data needed for troubleshooting as explained in "6.3 Collecting Data",a contact your Fujitsu engineer (CE or SE).
ssvsc0556
Explanation
A backup file was created for the VSC Engine environment settings but the file existence check terminated abnormally.
Parameters
0: Filename of the VSC Engine environment settings that were backed up
User action
Firmware installation
Check the following points, and then repeat the backup of the VSC Engine environment settings:
・Does the VSC Engine configuration backup directory exist?
・Is writing to the VSC Engine configuration backup directory permitted?
・Is there enough space in the VSC Engine configuration backup directory?
After checking the above points, repeat installation of the firmware.
If the same message is displayed despite taking the above action, then collect the data needed for troubleshooting as explained in "6.3 Collecting Data",a contact your Fujitsu engineer (CE or SE).
Backup of VSC Engine environment settings
Check the following points:
・Does the VSC Engine configuration backup directory exist?
・Is writing to the VSC configuration backup directory permitted?
・Is there enough space in the VSC Engine configuration backup directory?
After checking the above points, repeat the backup of the VSC Engine environment settings.
ssvsc0600
Explanation
The firmware version of the VSC Engine concerned does not meet the requirement for this function to be executed.
User action
Refer to the VSC Engine manual and upgrade the firmware of the VSC Engine.
ssvsc0700
Explanation
Failed to read the configuration information file.
User action
Confirm the status of the vsccompose file in the following directory.
Platform | Directory that vsccompose exists |
---|---|
Windows | $TMP_DIR\Manager\var\opt\FJSVssmgr\current |
Solaris OS, | /var/opt/FJSVssmgr/current |
No disk error has occurred.
The directory does not contain another directory.
The directory contains only files with extension .repository.
The directory contains a file.
If no file exists, use the commit script to restore the backup virtual storage configuration information into the following directory. After restoration, restart the manager.
Solaris OS, Linux: /vsccompose
Windows: \vsccompose
When all the conditions above are met, the configuration information file may be corrupt.
If the problem persists, refer to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
ssvsc0701
Explanation
The configuration information file could not be written to the directory specified.
Or, the update process of configuration information to VSC Engine failed.
User action
Take the following procedures to make checks.
Update the Virtual Storage Window (Maintenance) screen to check the latest status of the virtualization switch.
If the virtualization switche is stopped:
Check if the virtualization switch has been started. If not, proceed to step 2.
If the virtualization switch is working:
Proceed to step 3.
Take the following procedures.
Log into the virtualization switch by the username "admin" and enter the vscecreateconfigfile command to initialize the configuration information.
Log into the virtualization switch by the username "admin" and enter the reboot command to reboot the virtualization switch.
After the virtualization switch has been rebooted, proceed to step 3.
Once again update the Virtual Storage Window (Maintenance) screen to the latest status to check the status of the configuration information.
When the state of the composition data is Inconsistent
Refer to "6.2.3.3 Restoring the configuration information of a virtualization switch" to restore the configuration information.
When the state of the composition data is consistent
Confirm the status of the vsccompose file in the following directory.
Platform | Directory that vsccompose exists |
---|---|
Windows | $TMP_DIR\Manager\var\opt\FJSVssmgr\current |
Solaris OS, | /var/opt/FJSVssmgr/current |
No disk error has occurred.
The directory or file is not write-protected.
The file system of the directory has sufficient free disk space.
If migration or replication is in progress, cancel copying that has ended abnormally in the copying status view.
When all the conditions above are met, the configuration information file may be corrupt.
If the problem persists, refer to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
ssvsc0702
Explanation
The copy log file in the configuration data file is incorrect.
User action
Confirm the status of the vsclog file in the following directory.
Platform | Directory that vsclog exists |
---|---|
Windows | $TMP_DIR\Manager\var\opt\FJSVssmgr\current |
Solaris OS, | /var/opt/FJSVssmgr/current |
The directory or file has not been moved or deleted.
After confirming, restart VSC Manager.
ssvsc0703
Explanation
The copy log file could not be written to the directory specified.
User action
Confirm the status of the vsclog file in the following directory.
Platform | Directory that vsclog exists |
---|---|
Windows | $TMP_DIR\Manager\var\opt\FJSVssmgr\current |
Solaris OS, | /var/opt/FJSVssmgr/current |
No disk error has occurred.
The directory or file is not write-protected.
The file system has sufficient free disk space.
When all the conditions above are met, the copy log file may be corrupt. Move or delete the copy log file.
If the problem persists, refer to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
ssvsc0705
Explanation
Failed to write to the log file.
User action
Confirm the status of the vsclog file in the following directory.
Platform | Directory that vsclog exists |
---|---|
Windows | $TMP_DIR\Manager\var\opt\FJSVssmgr\current |
Solaris OS, | /var/opt/FJSVssmgr/current |
No disk error has occurred.
The directory or file is not write-protected.
The file system has sufficient free disk space.
When all the conditions above are met, the copy log file may be corrupt. Move or delete the copy log file.
If the problem persists, refer to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
ssvsc0800
Explanation
An error occurred in communication with the virtualization switch.
Parameters
0: Name of the virtualization switch used for communication
For virtualization switches other than the VS900 Model 200, the name of the virtualization switch is displayed as “virtualization switch name (host name)”.
User action
Confirm that:
VSC Engine starts
The network environment is normal
If the problem persists, refer to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
ssvsc0801
Explanation
Failed to communicate with the virtualization switch because the host name of the virtualization switch is invalid.
Parameters
0: Host name of the virtualization switch used for communication
For virtualization switches other than the VS900 Model 200, the name of the virtualization switch is displayed as “virtualization switch name (host name)”.
User action
Confirm that:
The port number of VSC Engine is correct.
VSC Engine is running.
Confirm that the network environment is normal.
If the problem persists, refer to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
ssvsc0802
Explanation
The specified physical disk returned a busy status.
User action
Execute the command again.
ssvsc0803
Explanation
The virtualization switch encountered an internal error.
User action
Referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
ssvsc0804
Explanation
In communication with the virtualization switch, the wait time (three minutes) was exceeded.
Parameters
0: Host name of the virtualization switch used for communication
For virtualization switches other than the VS900 Model 200, the name of the virtualization switch is displayed as “virtualization switch name (host name)”.
User action
Confirm that:
The virtualization switch specified as %HostName is operating.
The network environment is normal.
If the problem persists, refer to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
ssvsc0805
Explanation
The communication between virtualization switches failed.
User action
Confirm that the network environment is normal.
If the problem persists, refer to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
ssvsc0806
Explanation
An error occurred during communication with the virtualization switch.
Parameters
0: Host name of the virtualization switch to communicate with
For virtualization switches other than the VS900 Model 200, the name of the virtualization switch is displayed as “virtualization switch name (host name)”.
1: Number of units created successfully
2: Specified number of units
User action
Confirm that:
VSC Engine starts
The network environment is normal
If the problem persists, refer to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
ssvsc0807
Explanation
Communication with the virtualization switch failed because the host name of the virtualization switch was invalid.
Parameters
0: Host name of the virtualization switch to communicate with
For virtualization switches other than the VS900 Model 200, the name of the virtualization switch is displayed as “virtualization switch name (host name)”.
1: Number of units created successfully
2: Specified number of units
User action
Ensure that:
The port number of the VSC Engine is valid.
The VSC Engine is active.
The network environment contains no error.
If the problem persists, refer to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
ssvsc0808
Explanation
The busy status was reported from the specified physical disk.
Parameters
0: Number of units successfully created
1: Specified number of units
User action
Reenter the command.
ssvsc0809
Explanation
An internal error occurred on the visualization switch.
Parameters
0: Number of units successfully created
1: Specified number of units
User action
Referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
ssvsc0810
Explanation
In communication with the virtualization switch, the wait time (three minutes) was exceeded.
Parameters
0: Host name of the virtualization switch
For virtualization switches other than the VS900 Model 200, the name of the virtualization switch is displayed as “virtualization switch name (host name)”.
1: Number of units successfully created
2: Specified number of units
User action
Ensure that:
The virtualization switch that was set by %HostName is active.
The network environment contains no error.
If the problem persists, refer to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
ssvsc0811
Explanation
Communication between visualization switches failed.
Parameters
0: Number of units successfully created
1: Specified number of units
User action
Check for errors in the network environment.
If the problem persists, refer to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
ssvsc0812
Explanation
Communication between visualization switches failed.
Parameters
0: Host name of the virtualization switch to communicate with
For virtualization switches other than the VS900 Model 200, the name of the virtualization switch is displayed as “virtualization switch name (host name)”.
1: Number of units successfully deleted
2: Specified number of units
User action
Confirm that:
VSC Engine starts
The network environment is normal
If the problem persists, refer to "6.3 Collecting Data""6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
ssvsc0813
Explanation
Communication with the virtualization switch failed because the host name of the virtualization switch was invalid.
Parameters
0: Host name of the virtualization switch to communicate with
For virtualization switches other than the VS900 Model 200, the name of the virtualization switch is displayed as “virtualization switch name (host name)”.
1: Number of units successfully deleted
2: Specified number of units
User action
Ensure that:
The port number of the VSC Engine is valid.
The VSC Engine is active.
The network environment contains no error.
If the problem persists, refer to "6.3 Collecting Data""6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
ssvsc0814
Explanation
The busy status was reported from the specified physical disk.
Parameters
0: Number of units successfully deleted
1: Specified number of units
User action
Reenter the command.
ssvsc0815
Explanation
An internal error occurred in the visualization switch.
Parameters
0: Number of units successfully deleted
1: Specified number of units
User action
Referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
ssvsc0816
Explanation
In communication with the virtualization switch, the wait time (three minutes) was exceeded.
Parameters
0: Host name of the virtualization switch
For virtualization switches other than the VS900 Model 200, the name of the virtualization switch is displayed as “virtualization switch name (host name)”.
1: Number of units successfully deleted
2: Specified number of units
User action
Ensure that:
The virtualization switch that was set by %HostName is active.
The network environment contains no error.
If the problem persists, refer to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
ssvsc0817
Explanation
Communication between virtualization switches failed.
Parameters
0: Number of units successfully deleted
1: Specified number of units
User action
Check for errors in the network environment.
If the problem persists, refer to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
ssvsc0818
Explanation
Busy Status was returned from the specified physical disk.
Parameters
1: Physical disk information
2: Number of units successfully created
3: Specified number of units
User action
Execute the command again.
ssvsc0819
Explanation
Communication between virtualization switches failed.
Parameters
1: Physical disk information
2: Number of units successfully created
3: Specified number of units
User action
Check the network environment for errors.
If the problem persists, refer to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
ssvsc0820
Explanation
An internal error occurred in the virtualization switch.
Parameters
1: Physical disk information
2: Number of units successfully deleted
3: Specified number of units
User action
Referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
ssvsc0821
Explanation
An error occurred during communication with the virtualization switch.
Parameters
0: Host name of the virtualization switch to communicate with
For virtualization switches other than the VS900 Model 200, the name of the virtualization switch is displayed as “virtualization switch name (host name)”.
1: Physical disk information
2: Number of units successfully created
3: Specified number of units
User action
Confirm that:
VSC Engine starts
The network environment is normal
If the problem persists, refer to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
ssvsc0822
Explanation
Communication with the virtualization switch failed because the host name of the virtualization switch is invalid.
Parameters
0: Host name of the virtualization switch communicated with
For virtualization switches other than the VS900 Model 200, the name of the virtualization switch is displayed as “virtualization switch name (host name)”.
1: Physical disk information
2: Number of units successfully created
3: Specified number of units
User action
Confirm that:
The port number of VSC Engine is correct.
VSC Engine is active.
The network environment contains no error.
If the problem persists, refer to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
ssvsc0823
Explanation
A timeout (3 minutes) occurred during communication with the virtualization switch.
Parameters
0: Host name of the virtualization switch communicated with
For virtualization switches other than the VS900 Model 200, the name of the virtualization switch is displayed as “virtualization switch name (host name)”.
1: Physical disk information
2: Number of units successfully created
3: Specified number of units
User action
Confirm that:
The virtualization switch set with %HostName is active.
The network environment contains no error.
If the problem persists, refer to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
ssvsc0824
Explanation
Communication with a virtualization switch failed.
Parameters
0: Host name of virtualization switch in communication with
For virtualization switches other than the VS900 Model 200, the name of the virtualization switch is displayed as “virtualization switch name (host name)”.
1: Number of units successfully processed
2: Number of units specified
User action
Confirm that:
VSC Engine starts
The network environment is normal
If the problem persists, by referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, and contact your Fujitsu engineer (CE or SE).
ssvsc0825
Explanation
Communication with a virtualization switch failed because the host name of the virtualization switch is incorrect.
Parameters
0: Host name of the virtualization switch in communication with
For virtualization switches other than the VS900 Model 200, the name of the virtualization switch is displayed as “virtualization switch name (host name)”.
1: Number of units successfully processed
2: Number of units specified
User action
Confirm that:
VSC Engine port number is correct
VSC Engine is running
the network environment is normal
Referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
ssvsc0826
Explanation
An internal error was generated with the virtualization switch.
Parameters
0: Number of units successfully processed
1: Number of units specified
User action
Referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
ssvsc0827
Explanation
The communication timeout (3 minutes) for the virtualization switch has exceeded.
Parameters
0: Host name of virtualization switch
For virtualization switches other than the VS900 Model 200, the name of the virtualization switch is displayed as “virtualization switch name (host name)”.
1: Number of units successfully processed
2: Number of units specified
User action
Confirm that:
The virtualization switch specified with %HostName is activated
The network environment is normal
If the problem persists, by referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, and contact your Fujitsu engineer (CE or SE).
ssvsc0828
Explanation
Communication with a virtualization switch failed.
Parameters
0: Number of units successfully processed
1: Number of units specified
User action
Confirm that the network environment is normal.
If the problem persists, by referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, and contact your Fujitsu engineer (CE or SE).
ssvsc0829
Explanation
The operation terminated abnormally because an error was returned from the VSC Engine.
Parameters
0: VSC Engine error code
User action
Refer to “VSC Engine”.
ssvsc0830
Explanation
The operation terminated abnormally because an error was returned from the VSC Engine.
Parameters
0: VSC Engine error code
1: Number of units successfully created
2: Specified number of units
User action
Refer to “VSC Engine”.
ssvsc0902
Explanation
The command started.
Parameters
0: Name of the command that started
User action
None
ssvsc0903
Explanation
The command ended.
Parameters
0: Name of the command that ended
User action
None
ssvsc0905
Explanation
An error occurred in the commit script.
Parameters
0: Error information of the commit script
User action
Confirm that the commit script is correctly written.
Confirm that the commit script runs normally by itself.
ssvsc0906
Explanation
The commit script file cannot be found in the specified folder.
Parameters
0: File name of the commit script
User action
Confirm that:
the commit script file is stored in the specified folder
the directory or file specified in the commit script is not write-protected.
ssvsc0907
Explanation
The commit script output %Message to standard output.
Parameters
0: Message that was output
User action
None
ssvsc0908
Explanation
The commit script output %Message to standard error output.
Parameters
0: Error message that was output
User action
Confirm that the commit script is correctly written.
Confirm that the commit script runs normally by itself.
ssvsc0909
Explanation
VSC Manager stopped normally.
User action
None
ssvsc0913
Explanation
The specified device is used by virtual storage.
User action
The device cannot be deleted.
To delete the device, release all physical disks of the specified device.
ssvsc1300
Explanation
There is an inconsistency in the configuration information for the virtual storage device.
User action
Collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
Refer to "6.3 Collecting Data".
ssvsc1301
Explanation
A virtualization switch from a different switch group has been specified.
Parameters
0: The specified switch group
User action
Open the Virtual Storage window (Maintenance), specify all of the virtualization switches that belong to the same switch group, and then execute the command again.
ssvsc1302
Explanation
A virtualization switch from a different switch group has been specified.
Parameters
0: The specified switch group
User action
Open the Virtual Storage window (Maintenance), specify all of the virtualization switches that belong to the same switch group, and then execute the command again.
ssvsc1304
Explanation
The SAN management information or the relationship management information may not be in the latest status.
User action
Update the SAN management information or the relationship management information to the latest.
Otherwize, check the connection cable of physical resources and the following settings of physical resources.
host affinity of storage device
virtualization switch zoning
If the problem persists, by referring to "6.3 Collecting Data", collect the necessary data for troubleshooting, and contact your Fujitsu engineer (CE or SE).
ssvsc1305
Explanation
The logical volume is configured with multiple affinity groups.
Parameters
0: Specified logical volume
User action
Check the configuration of affinity groups related to the specified logical volume on the storage device.
ssvsc1306
Explanation
The logical volume is configured with multiple Host LUNs.
Parameters
0: Specified logical volume
User action
Check the configuration of Host LUNs related to the specified logical volume on the storage device.
ssvsc1307
Explanation
A virtual disk that is optimal in terms of assigned CMs cannot be configured for the specified virtual disk because it consists of physical disks with different assigned CMs.
Parameters
0: VSC Engine error code
User action
Take one of the following actions:
Select the physical disks directly, without using the [Candidate Selection] or [Automatic Creation] button.
Use the migration function to increase the capacity of the disk.
ssvsc1308
Explanation
The allocation for the virtualization disk failed to be released because an error occurred on the virtualization switch.
Parameters
0: VSC Engine error code
User action
Collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
Refer to "6.3 Collecting Data".
ssvsc1309
Explanation
It is not possible to create multiple copy security groups with the same name.
User action
Use the Virtual Storage window (View and Create) to check the names of the existing copy security groups, and specify a copy security group name that is not being used.
ssvsc1310
Explanation
No more copy security groups can be created.
User action
Delete any copy security groups that are no longer required, and then execute the processing again.
Refer to Appendix D, "Appendix D Limit Values" for information about the number of copy security groups that can be created.
ssvsc1311
Explanation
Either there is a problem with the copy security group, or the copy security group does not exist.
User action
Use the Virtual Storage window (View and Create) to check the name of the copy security group.
ssvsc1312
Explanation
Copy security groups where virtual enclosures have been registered cannot be deleted.
Parameters
0: Name of the copy security group
User action
Use the Virtual Storage window (View and Create) to check whether there are virtual enclosures in the copy security group to be deleted.
ssvsc1313
Explanation
The specified virtual enclosure has already been registered with the copy security group.
Parameters
0: Name of the virtual enclosure
User action
Use the Virtual Storage window (View and Create) to check which virtual enclosures have been registered with the copy security group.
ssvsc1314
Explanation
No more virtual enclosures can be registered with the copy security group.
User action
Delete any virtual enclosures in the copy security group that are no longer required, and then execute the processing again.
Refer to Appendix D, "Appendix D Limit Values" for information about the number of virtual enclosures that can be registered in each copy security group.
ssvsc1315
Explanation
The specified virtual enclosure has not been registered with the specified copy security group.
Parameters
0: Name of the virtual enclosure
User action
Use the Virtual Storage window (View and Create) to check the copy security group.
ssvsc1316
Explanation
A virtual disk in the specified virtual enclosure may be being used by an ETERNUS SF AdvancedCopy Manager replication.
User action
Use the Virtual Storage window (Copy) to check whether an ETERNUS SF AdvancedCopy Manager replication is being performed.
ssvsc1317
Explanation
The specified copy security group has already been registered with the virtual enclosure.
Parameters
0: Name of the copy security group
User action
Use the Virtual Storage window (View and Create) to check which copy security groups have been registered with the virtual enclosure.
ssvsc1318
Explanation
The specified virtual enclosure has not been registered with the specified copy security group.
Parameters
0: Name of the copy security group
User action
Use the Virtual Storage window (View and Create) to check the copy security group.
ssvsc1319
Explanation
It is possible that a virtual disk in a virtual enclosure that has been registered with the specified copy security group is being used by an ETERNUS SF AdvancedCopy Manager replication.
User action
Use the Virtual Storage window (Copy) to check whether an ETERNUS SF AdvancedCopy Manager replication is being performed.
ssvsc1320
Explanation
An invalid value has been specified for the maximum number of copy sessions.
User action
Specify a valid value and then execute the processing again.
Refer to Appendix D, "Appendix D Limit Values" for information about valid values.
ssvsc1321
Explanation
The value specified for the maximum number of copy sessions cannot be set because it is lower than the number of copy sessions currently in progress.
User action
Use the Virtual Storage window (Copy) to check the number of copy sessions currently in progress, and then make the setting again.
Refer to “Max copy multiplicity” in Appendix D, "Appendix D Limit Values" for information about the maximum number of copy sessions.
ssvsc1322
Explanation
There are too many virtual enclosures that permit ETERNUS SF AdvancedCopy Manager replications that can be registered with virtual enclosures.
User action
Use the Virtual Storage window (Copy) to check the copy security groups registered with the virtual enclosure.
ssvsc1323
Explanation
Virtual enclosures where copy security groups have been registered cannot be deleted.
User action
Release all of the copy security groups that have been registered with the virtual enclosure.
ssvsc1324
Explanation
Virtual enclosures that have been registered with copy security groups cannot be deleted.
Parameters
0: Name of the virtual enclosure
User action
Release the virtual enclosure from all of the copy security groups with which it has been registered.
ssvsc1325
Explanation
The specified virtual enclosure cannot be deleted because one of its virtual disks is being used by an ETERNUS SF AdvancedCopy Manager replication.
User action
Use the Virtual Storage window (Copy) to check whether an ETERNUS SF AdvancedCopy Manager replication is being performed.
ssvsc1326
Explanation
Either there is a problem with the copy security group, or the copy security group does not exist.
Parameters
0: Number of units successfully created
1: Specified number of units
User action
Use the Virtual Storage window (View and Create) to check the name of the copy security group.
ssvsc1327
Explanation
Copy security groups where virtual enclosures have been registered cannot be deleted.
Parameters
0: Name of the copy security group
1: Number of units successfully created
2: Specified number of units
User action
Use the Virtual Storage window (View and Create) to check whether there are virtual enclosures in the copy security group to be deleted.
ssvsc1328
Explanation
Virtual enclosures where copy security groups have been registered cannot be deleted.
Parameters
0: Name of the virtual enclosure
1: Number of units successfully created
2: Specified number of units
User action
Release all of the copy security groups that have been registered with the virtual enclosure.
ssvsc1329
Explanation
Virtual enclosures that have been registered with copy security groups cannot be deleted.
Parameters
0: Name of the virtual enclosure
1: Number of units successfully created
2: Specified number of units
User action
Release the virtual enclosure from all of the copy security groups with which it has been registered.
ssvsc1330
Explanation
The specified virtual enclosure cannot be deleted because one of its virtual disks is being used by an ETERNUS SF AdvancedCopy Manager replication.
Parameters
0: Number of units successfully created
1: Specified number of units
User action
Use the Virtual Storage window (Copy) to check whether an ETERNUS SF AdvancedCopy Manager replication is being performed.
ssvsc1331
Explanation
The HostLUN number for the specified physical disk is not the same on all VSC Engines.
User action
Check the configuration of the storage device and the virtualization switch.
If the problem persists, collect the necessary data for troubleshooting, then contact your Fujitsu engineer (CE or SE).
Refer to "6.3 Collecting Data".
ssvsc1332
Explanation
The specified physical disk does not belong to the same switch group as the copy source virtual disk.
User action
Check whether the specified physical disk belongs to the same switch group as the copy source virtual disk.
ssvsc1336
Explanation
The configuration is not recommended for a virtual storage environment because some logical volume paths use the same CM.
Parameters
0: Targeted logical volume number
User action
Correct the storage configuration and physical connections so that the same CM is not used. For details on the recommended configurations, refer to the "ETERNUS SN200 Model 540 Fibre Channel Switch Virtualization Blade and VS900 Model 300 Virtualization Switch System Build Procedure".
ssvsc1337
Explanation
The configuration is not recommended for a virtual storage environment because the paths between virtualization switches and storage include paths where more than one virtualization switch uses a CM.
Parameters
0: Targeted CM number
User action
Correct the storage configuration and physical connections so that the same CM is not used. For details on the recommended configurations, refer to the "ETERNUS SN200 Model 540 Fibre Channel Switch Virtualization Blade and VS900 Model 300 Virtualization Switch System Build Procedure".