ETERNUS SF Storage Cruiser User's Guide 13.2 - Solaris (TM) Operating System / Linux / Microsoft(R) Windows(R) -
Contents Index PreviousNext

Chapter 3 Operation Design

3.1 LAN Connections

Manager manages devices, using the LAN I/Fs of a device subject to management.

Connect the LAN for management to all devices subject to management.

In this case, transactions affected by management can be minimized by separating the LAN for management from that for transaction.

3.1.1 Network requirements

When a firewall is placed between Manager and a device subject to management, set the following port numbers to be able to pass the firewall.

+Communication with the client

Transmission destination

Port/protocol

Transmission start direction

Function

Manager

23456/tcp

Client -> manager

GUI display/operation

Device subject to management

Depends on the device subject to management

Depends on the device subject to management

Calling Management Software

+Communication with the manager

Transmission destination device

Port/protocol

Transmission start direction

Function

Server node (Agent)

4917/tcp

Manager -> device

Configuration management, polling monitoring, fault monitoring

162/udp

Device -> Manager

Fault management

Fibre Channel switch
ETERNUS SN200
BX600 Fibre Channel switch blade

161/udp

Manager -> device

Configuration management, performance management,

Polling monitoring

23/tcp

Manager -> device

Configuration management

162/udp

Device -> Manager

Fault management

Virtualization switch device
ETERNUS VS900

5988/tcp

Manager -> Brocade SMI Agent

Configuration management

7420/tcp

7420/udp

Device -> Manager

Configuration management

162/udp

Device -> Manager

Fault monitoring

ping/icmp

Manager -> device

Polling monitoring

Disk array unit
ETERNUS8000
ETERNUS6000
ETERNUS4000
ETERNUS3000 (excluding M50)

ETERNUS2000
ETERNUS GR series (excluding GR710 and GR720)

161/udp

Manager -> device

Configuration management, performance management, polling monitoring

1999/tcp

Manager -> device

Configuration management

162/udp

Device -> Manager

Fault management

Disk array unit
ETERNUS3000 M50
ETERNUS GR710,GR720

161/udp

Manager -> device

Configuration management, polling monitoring

80/tcp

Manager -> device

Configuration management

1999/tcp

Manager -> device

Configuration management

162/udp

Device -> Manager

Fault management

Hitachi

SANRISE1000/2000

161/udp

Manager -> device

Configuration management

162/udp

Device -> Manager

Fault management

ping/icmp

Manager -> device

Polling monitoring

EMC Symmetrix 3000/5000/ESP/8000

161/udp

Manager -> device

Configuration management

162/udp

Device -> Manager

Fault management

ping/icmp

Manager -> device

Polling monitoring

Tape library unit
LT270,LT250,LT160

161/udp

Manager -> device

Configuration management

162/udp

Device -> Manager

Fault management

ping/icmp

Manager -> device

Polling monitoring

Bridge unit
Crossroads

161/udp

Manager -> device

Configuration management

23/tcp

Manager -> device

Configuration management

ping/icmp

Manager -> device

Polling monitoring

Network disk array

NR1000

162/udp

Device -> Manager

Fault management

161/udp

Manager -> device

Polling monitoring

Manual embedding, and others

162/udp

Device -> Manager

Fault management

ping/icmp

Manager -> device

Polling monitoring

3.1.2 SNMP Community  

The manager and managed devices use the following SNMP community.

Transmission destination device

Default (*)

Access

Method of settings

Fibre channel switch
ETERNUS SN200
BX600 Fibre channel switch blade

public

read

Refer to 4.2.1.1 Setting"for detailed settings.

private

read/write

SN200 MDS(Cisco MDS) Fibre channel switch

public

read

Refer to 4.2.4.1 Settings"for detailed settings.

McDATA Fibre channel switch

public

read

Refer to 4.2.5.1 Settings"for detailed settings.

Disk array devices ETERNUS8000
ETERNUS6000
ETERNUS4000
ETERNUS3000
ETERNUS2000
ETERNUS GR series

public

read

Refer to 4.3.1.1 Setting"for detailed settings.

*: The changes listed are performed on the "SNMP_COMMUNITY_NAME_FOR_IP" parameter in the sanma.conf file.Refer to "Appendix D Customization" for details.


Contents Index PreviousNext