Top
ETERNUS SF Express V16.9 / Storage Cruiser V16.9 / AdvancedCopy Manager V16.9 Web Console Guide
FUJITSU Storage

3.1 Update of Information (Refresh Screen)

The information displayed on the screen is updated automatically at intervals (Default is 30 seconds) set to Screen Refresh Interval. The input item in the screen is held before and after the update.

According to the setting of Target of the screen refresh preference, the area updated automatically is different as shown in the following tables.

Object to Be Updated

Explanation

Entire

Automatic refresh is active for the whole area (Menu area, Category pane, Main pane, Action pane, and Job Status pane) of the screen.

However, when it meets any following requirements, the Category pane, the Main pane, and the Action pane are not updated automatically.

  • The screen for setting or the Map View screen is displayed.

  • A dialog box is displayed.

Menu area and Job Status pane

Automatic refresh is active for the menu area and Job Status pane only.

None (Disabled)

Automatic refresh is inactive.

The screen can be updated manually by clicking in the menu area.

Information

Note

  • The automatic refresh never operates on the screen before log in and the screen displayed by another window.

    • Login screen

    • Session Timeout screen

    • Logical Path View

    • End to End View detail screen

    • Performance Chart window

  • The balancing level of the Tier pool balancing is not refreshed automatically. To show the latest balancing level, perform the Status Update operation of Automated Storage Tiering.

  • Clicking resets the following setting values in the Main pane to the default value. Refer to "2.5.3 Main Pane" for respective setting.

    • Filter setting

    • Page setting

    • Displayed records setting

    In addition, when information screen has tabs, clicking displays the leftmost tab information on the Main pane regardless of the current tab.

  • Clicking does not reset values in the Filter Setting on the Job Status pane.

  • Clicking displays the existing information held by ETERNUS SF system. It does not acquire updated information from the devices. Clicking Reload Conf. or Refresh in an Action pane obtains updated information from the device. To update the information of Automated Storage Tiering to the latest status, you need to perform the procedure that is described in "9.14.25 Update Automated Storage Tiering Information".
    However, automatically collected device information excludes system information, status (*1), device resource usage capacity / rate and performance management configuration information (*2) for the following devices. Clicking displays the automatically collected information.

    • ETERNUS DX S5/S4/S3 series (All firmware versions)

    • ETERNUS DX S2 series (excluding the ETERNUS DX60 S2. V10L40 or later firmware)

    • ETERNUS AF All-Flash Arrays (All firmware versions)

    • ETERNUS DX200F (All firmware versions)

    *1: For devices that support automatic updates of the device component status, this product acquires the device configuration status automatically from the device. For this reason, you do not need to perform the Reload Conf. operation for the device. For devices that support automatic updates of the device component status, refer to "Monitoring Device Component Status" in the Storage Cruiser Operation Guide.

    *2: The performance management configuration information is automatically updated when "All" is selected for the range of monitored volumes at the start of performance management. Refer to "Instruction for Performance Management" in the Storage Cruiser Operation Guide for details.