Top
PRIMECLUSTER Global Link Services Configuration and AdministrationGuide 4.6Redundant Line Control Function
FUJITSU Software

A.1.3 Console output messages (numbers 800 to 900)

The following describes the messages output on the console by Redundant Line Control Function, explanation, and operator response.

The following table shows facilities and priorities for the message numbers output to the system log.

Facility

Priority

Message number

kern

info

800, 801, 990, 991, 992

kern

error

910, 911, 912, 913, 914

user

info

888, 889, 890, 891, 892, 893, 894, 895

user

warning

848

user

error

other than those above

Note

Messages with the following message numbers are not output on the console but output only on the system log.

888, 889, 890, 891, 892, 893, 894, 895

Table A.5 Message number 8xx

Message number

Message

Meaning

Action

800

line status changed: Link Down at TRUNKING mode (interface on devicename, target=host_name)

An error occurred in the communication with the remote host system (host_name) using the physical interface (interface) controlled by the virtual interface (devicename) that is operating in the Fast switching mode.

Check whether an error has occurred on the communication path to the remote host system.

801

line status changed: Link Up at TRUNKING mode (interface on devicename, target=host_name)

The communication with the remote host system (host_name) using the physical interface (interface) controlled by the virtual interface (devicename) is recovered.

No action is required.

802

file open failed.

Failed to open the file.

No action is required.

803

file read failed.

Failed to read the file.

Collect materials for examination of Redundant Line Control Function, and then contact field engineers to report the error message.

804

pipe create failed.

Failed to create the internal communication pipe.

Collect materials for examination of Redundant Line Control Function, and then contact field engineers to report the error message.

805

internal error.

An internal error occurred.

Collect materials for examination of Redundant Line Control Function, and then contact field engineers to report the error message.

806

cannot get my process id

Failed to obtain the local process ID.

Collect materials for examination of Redundant Line Control Function, and then contact field engineers to report the error message.

814

cannot up interface.

Failed to up the virtual interface.

Check if the operating system configuration file (ifcfg-ethX) is correct. For details, see "3.2.2 Network configuration". If a virtual bridge has been connected to the virtual interface, check that the virtual bridge has been activated.

If no problem has been found, collect materials for the examination of the Redundant Line Control function and contact field engineers to report the error message.

815

sha device open failed.

Failed to open the "sha" driver.

Collect materials for examination of Redundant Line Control Function, and then contact field engineers to report the error message.

822

no data in cluster event.

No data was found in the cluster event.

Make sure that the Redundant Line Control Function and the cluster system are correctly set. If there is no problem, collect materials for the examination of the Redundant Line Control Function and the cluster system, and then contact field engineers to report the error message. See the manual of the cluster system as to the materials necessary for examining the cluster system.

823

ClSetStat failed.

The cluster resource status could not be set.

Make sure that the Redundant Line Control Function and the cluster system are correctly set. If there is no problem, collect materials for the examination of the Redundant Line Control Function and the cluster system, and then contact field engineers to report the error message. See the manual of the cluster system as to the materials necessary for examining the cluster system.

824

directory open failed.

Failed to open the directory.

Collect materials for examination of Redundant Line Control Function, and then contact field engineers to report the error message.

825

signal send failed.

Failed to send the signal.

Collect materials for examination of Redundant Line Control Function, and then contact field engineers to report the error message.

826

command can be executed only with super-user.

The execution-time authority is invalid.

Collect materials for examination of Redundant Line Control Function, and then contact field engineers to report the error message.

827

could not allocate memory.

Failed to obtain the memory.

Collect materials for examination of Redundant Line Control Function, and then contact field engineers to report the error message.

828

fork failed.

The fork () failed.

Collect materials for examination of Redundant Line Control Function, and then contact field engineers to report the error message.

829

child process execute failed.

Failed to generate the child process.

Collect materials for examination of Redundant Line Control Function, and then contact field engineers to report the error message.

830

getmsg failed.

Failed to receive the data from the "sha" driver.

Collect materials for examination of Redundant Line Control Function, and then contact field engineers to report the error message.

833

ioctl(SHAIOCSETIPADDR) failed.

Failed to notify the IP address.

Collect materials for examination of Redundant Line Control Function, and then contact field engineers to report the error message.

847

internal error retry over. polling stop.

A HUB monitoring internal error occurred. The HUB monitoring is stopped.

Make sure that the system, the Redundant Line Control Function, and the cluster system are correctly set. If the same phenomenon occurs, collect materials for the examination of the Redundant Line Control Function and the cluster system, and then contact field engineers to report the error message. See the manual of the cluster system as to the materials necessary for examining the cluster system.

848

device is inactive. polling stop.

The virtual interface for HUB monitoring is not activated. The HUB monitoring function is disabled.

Activate the virtual interface. Then, inactivate and activate the HUB monitoring function. This message may be displayed when cluster switching occurs during cluster operation, but in this case, no action is needed.

850

cannot down interface.

Failed to inactivate the physical interface.

Check if the Redundant Line Control function and the system are correctly set, and check if the operating system configuration file (ifcfg-ethX) is correct. For details, see "3.2.2 Network configuration". If no problem has been found, collect materials for the examination of the Redundant Line Control function and contact field engineers to report the error message.

853

physical interface up failed.

Failed to activate a physical interface.

Make sure that the Redundant Line Control Function and the system are correctly set. If there is no problem, collect materials for the examination of the Redundant Line Control Function, and then contact field engineers to report the error message.

857

polling information is not defined.

Monitoring destination information is not defined.

Define monitoring destination information using the hanetpoll command.

858

observe information is not defined.

Monitoring destination information is not defined.

Define monitoring destination information using the hanetobserv command.

860

interface does not exist.

There is no interface which NIC switching mode is using.

Collect materials for examination of Redundant Line Control Function, and then contact field engineers to report the error message.

861

cannot set interface flags.

The flag operation to an interface in use became failure.

Collect materials for examination of Redundant Line Control Function, and then contact field engineers to report the error message.

870

polling status changed: Primary polling failed. (ifname,target=pollip)

Ping monitoring on the primary side has failed.
ifname: Interface name pollip: Monitoring destination address
vlanid: VLAN for monitoring destination

Check that there is no problem in communication routes to the monitoring destination. Perform recovery steps as needed (see "H.3.1 Error messages(870) and corresponding actions for HUB monitoring"). When monitoring is failed even if communication is normal, tuning is required for the monitoring interval and the number of monitoring.

polling status changed: Primary polling failed. (ifname,target=pollip, vlan=vlanid)

871

polling status changed: Secondary polling failed. (ifname,target=pollip)

Ping monitoring on the secondary side has failed.
ifname: Interface name pollip: Monitoring destination address
vlanid: VLAN for monitoring destination

Check that there is no problem in communication routes to the monitoring destination. Perform recovery steps as needed (see "H.3.1 Error messages(870) and corresponding actions for HUB monitoring"). When monitoring is failed even if communication is normal, tuning is required for the monitoring interval and the number of monitoring.

polling status changed: Secondary polling failed. (ifname,target=pollip, vlan=vlanid)

872

polling status changed: PrimaryHUB to SecondaryHUB polling failed. (ifname,target=pollip)

An error in the secondary HUB was detected by HUB-to-HUB communication monitoring from the primary interface.
ifname: Interface name
pollip: Monitoring destination address

Check for any failure on the communication path to the monitoring destination. If monitoring fails even though possible to communicate normally, tune the intervals and the number of the times of monitoring, and the time to wait for a linkup with the hanetpoll command. Review "H.3.1 Error messages(870) and corresponding actions for HUB monitoring".

873

polling status changed: SecondaryHUB to PrimaryHUB polling failed. (ifname,target=pollip)

An error in the primary HUB was detected by HUB-to-HUB communication monitoring from the secondary interface.
ifname: Interface name
pollip: Monitoring destination address

Check for any failure on the communication path to the monitoring destination. If monitoring fails even though possible to communicate normally, tune the intervals and the number of the times of monitoring, and the time to wait for a linkup with the hanetpoll command. Review "H.3.1 Error messages(870) and corresponding actions for HUB monitoring".

874

polling status changed: HUB repair (target=pollip)

Line failure in ping monitoring has repaired.
pollip: Monitoring destination address
vlanid: VLAN for monitoring destination

No action is required.

polling status changed: HUB repair (target=pollip,vlan=vlanid)

875

standby interface failed.(ifname)

Route failure was detected by the standby patrol.
ifname: Interface name of standby patrol
vlanid: VLAN for monitoring destination

Check that there is no problem in communication routes between the operating NIC and the standby NIC. Perform recovery steps as needed (see "H.3.2 Error messages(875) and corresponding actions for standby patrol"). When monitoring is failed even if communication is normal, tuning is required for the monitoring interval and the number of monitoring.

standby interface failed.(ifname, vlan=vlanid)

876

node status is noticed.(sourceip:status)

A node status change was notified from the remote system.
sourceip: Source address
status: Notified status

Check the status of the source.

877

route error is noticed.(sourceip)

A communication path failure was notified from the remote system.
sourceip: Source address

Check for any failure on the communication path to the source.

878

route error is detected.(target=IP)

A communication path failure was detected from the remote system.
IP: Remote system address

Check for any failure on the communication path to the source.

879

message received from unknown host.(srcaddr)

A message was received from an unregistered remote system.
srcaddr: Source address

Register the corresponding remote host using the hanetobserve command.

880

failed to send node down notice by time out. (dstip)

Node status notification failed due to timeout.
dstip: Destination address

Check for any failure of the remote system and on the communication path to the remote system.

881

semaphore is broken. (errno)

Creates a semaphore again because it is deleted.

It is not necessary to deal with.

882

shared memory is broken. (errno)

Creates a shared memory again because it is deleted.

It is not necessary to deal with.

883

activation of a wrong interface has been detected. (ifname) (code)

Since the interface was unjustly activated by the user, the state of an interface is restored.
ifname: interface name
code: detailed code

Check that the interface has been recovered correctly.
If this message was output except when a user has intentionally performed Up/Down of the physical interface, investigate the cause of Up/Down.

884

unexpected interface deactivation has been detected. (ifname) (code)

Since the interface was unjustly deactivated by the user, the state of an interface is restored.
ifname: interface name
code: detailed code

Check that the interface has been recovered correctly.
If this message was output except when a user has intentionally performed Up/Down of the physical interface, investigate the cause of Up/Down.

885

standby interface recovered.(ifname)

The recovery of the route in the standby side was detected by standby patrol.
ifname: Interface name of standby patrol
vlanid: VLAN for monitoring destination

It is not necessary to deal with.

standby interface recovered.(ifname, vlan=vlanid)

886

recover from route error is noticed.(ifname)

The recovery was notified from the remote system.
ifname: Interface name

It is not necessary to deal with.

887

recover from route error is detected. (target=IP)

The recovery of the remote system was detected.
IP: Remote system address

It is not necessary to deal with.

888

interface is activated. (ifname)

The physical interface was activated.
ifname: Interface name

It is not necessary to deal with.

889

interface is inactivated. (ifname)

The physical interface was inactivated.
ifname: Interface name

It is not necessary to deal with.

890

logical IP address is activated. (logicalIP)

The logical IP address was activated.
logicalIP: Logical IP

It is not necessary to deal with.

891

logical IP address is inactivated. (logicalIP)

The logical IP address was inactivated.
logicalIP: Logical IP

It is not necessary to deal with.

892

logical virtual interface is activated. (ifname)

The logical virtual interface was activated.
ifname: Interface name

It is not necessary to deal with.

893

logical virtual interface is inactivated. (ifname)

The logical virtual interface was inactivated.
ifname: Interface name

It is not necessary to deal with.

894

virtual interface is activated. (ifname)

The virtual interface was activated.
ifname: Interface name

It is not necessary to deal with.

895

virtual interface is inactivated. (ifname)

The virtual interface was inactivated.
ifname: Interface name

It is not necessary to deal with.

896

path to standby interface is established. (ifname)

Monitoring by standby patrol has started normally.
Ifname: Interface name of standby patrol
vlanid: VLAN for monitoring destination

It is not necessary to deal with.

path to standby interface is established. (ifname, vlan=vlanid)

897

immediate exchange to primary interface is canceled. (ifname)

The immediate automatic fail-back to the primary interface by the standby patrol was restrained.
ifname: A name of an interface.
This message is output when the monitor-to information to set by a hanetpoll create command is other than HUB.

It is not necessary to deal with.

898

unexpected interface flags have been detected. (ifname) (code)

Since the interface was unjustly changed by the user, the state of an interface is restored.
ifname: interface name
code: detailed code

Check that the interface has been recovered correctly. In addition, when this message is displayed to the user operating nothing, please investigate the cause of the interface flag change.

899

route to polling address is inconsistent.

The network address defined to virtual interface and monitoring target is not the same, or since inappropriate routing information was registered into routing table, the mistaken monitoring is performed.

Please correct, when you check monitoring target address and there is an error. When there is no error in monitoring target address, please check whether inappropriate routing information is registered into the routing table. When using tagged VLAN interface, please confirm whether a virtual interface is a setting of NIC switching mode (operation mode "d").
If you are using NIC switching (operation mode "e"), change the operation mode, or perform asynchronous switching. Also, change the monitored remote system settings according to the message.

Table A.6 Message number 9xx

Message number

Message

Meaning

Action

900

routing information has inconsistency.

Routing information of the communication target, which is set by using the hanetobserv command, is not registered into the routing table, or inconsistent routing information is registered.

Check if there is any inconsistency between the following information:

  • A gateway address of the real IP address of the communication target set by using the hanetobserv command

  • Routing information registered into the routing table

906

route error to virtual ip address is detected. (target=xxx.xxx.xxx.xxx)

Every monitoring path for the virtual addresses of the remote system failed.

Check that there is no problem with the communication path to the virtual IP addresses of the remote system.

907

recover from route error to virtual ip address is detected. (target=xxx.xxx.xxx.xxx)

Monitoring the virtual IP addresses of the remote system is now possible.

No action is required.

908

hanetctld restarted.

The control daemon of the GLS is restarted.

No action is required.

909

failed to restart daemon.

Restarting the control daemon of the GLS is failed.

Restart the Redundant Line Control Function for recovery (/opt/FJSVhanet/usr/sbin/resethanet -s). When recovery is failed, restart the OS.

910

link up detected: the physical interface link is up. (devicename: ifname)

The physical interface is linked up.

devicename: Virtual interface name

ifname: Physical interface name

No action is required.

911

link down detected: the physical interface link is down. (devicename: ifname)

The physical interface is linked down.

devicename: Virtual interface name

ifname: Physical interface name

Check the link state based on the execution results of the /usr/sbin/ip addr show ifname command (LOWER_UP flag displayed) and the /sbin/ethtool ifname command ("Link detected: yes" displayed).

If the link is down, check whether the neighboring switch works, and whether the speed settings (auto negotiation, full-duplex, etc) for the switch and server are correctly set.

912

link up detected: the virtual interface link is up. (devicename)

The virtual interface is linked up.

devicename: Virtual interface name

No action is required.

913

link down detected: the virtual interface link is down. (devicename)

The virtual interface is linked down.

devicename: Virtual interface name

Check the link status of the physical interface bundled by the virtual interface.

914

the physical interface of the virtual interface was switched. (devicename: vlantype

from=ifname1 to=ifname2)

The physical interface which is used for communication of the virtual interface has been switched.

devicename: Virtual interface name

vlantype: "untagged" or "tagged"

ifname1: Physical interface before switching

ifname2: Physical interface after switching

Check the link status of the physical interface bundled by the virtual interface.

No action is required when the "hanetnic change" command is executed.

*vlantype

The "vlantype" is output when a tagged VLAN interface is created on the virtual interface. Take note that depending on the OS version, the "vlantype" is output even when a virtual bridge is created on the virtual interface.

916

monitoring function detected failures in the entire transfer route. (ifname)

Failures in all transfer routes are detected by the network monitoring function.

ifname: Interface name
vlanid: VLAN for monitoring destination

Check that there is no problem in transfer routes to the monitoring destination and transfer routes between the operating NIC and the standby NIC.

monitoring function detected failures in the entire transfer route. (ifname, vlan=vlanid)

923

physical interface is already linked by another network device. (device:ifname)

The specified physical interface cannot be bundled. It has already been used by another network device such as bonding.

device: Virtual interface name

ifname: Physical interface name

Review the setting of the interface.

927

physical interface settings is incorrect.(name=device ifname=interface param=XXXX)

There is an error in the physical interface settings.

Modify the physical interface configuration file (/etc/sysconfig/network-scripts/ifcfg-ethX). For details, see "3.2.2 Network configuration." After the modification is completed, restart the operating system.

928

physical interface configuration file not found.(name=device ifname=interface)

There is no physical interface configuration file.

Failed to see the physical interface configuration file (/etc/sysconfig/network-scripts/ifcfg-ethX). Check the file. For details, see "3.2.2 Network configuration." After the modification is completed, restart the operating system.

929

SHAMACADDR is not specified. (name=device)

SHAMACADDR is not specified.

device: Virtual interface name

It is necessary to specify SHAMACADDR on a guest OS on VMware or on Hyper-V. Check the setting of SHAMACADDR in the virtual interface configuration file (/etc/sysconfig/network-scripts/ifcfg-shaX).

930

SHAMACADDR is invalid MAC address. (name=device)

The MAC address specified to SHAMACADDR is invalid.

device: Virtual interface name

Specify the correct MAC address to SHAMACADDR. After that, restart the operating system.

931

hangup of ping command has been detected. (target=pollip)

A hang-up of the ping command for the monitoring destination is detected.

pollip: Monitoring destination IP address

Collect materials for examination of Redundant Line Control Function, and then contact field engineers to report the error message.

932

cannot send fhsp message. (dest=hostip, code)

The message of Fujitsu Hot Standby Protocol failed to be sent.

hostip: Destination IP address

code: Detailed code

Check if the setting to pass through the firewall is correctly set for Fujitsu Hot Standby Protocol (UDP: port number 1807). If no problem has been found, collect materials for the examination of the Redundant Line Control function and contact field engineers to report the error message.

973

failed to startup self-checking.

The self-checking function failed to start.

Follow the instructions of the previously displayed message.

974

sha driver error has been detected.

GLS driver error has been detected.

Follow "3.11.2.2 Error detection of the self-checking function" to take the appropriate action.

976

hanetctld error has been detected.

GLS daemon error has been detected.

If a recovery message of 977 is displayed, no action is required. If not displayed, follow "3.11.2.2 Error detection of the self-checking function" to take the appropriate action.

977

hanetctld recovery has been detected.

GLS daemon recovery has been detected.

No action is required.

979

failed to execute a shell script.

User script execution has failed.

Check that the user script file is present. Also, check whether the system resources are running out by checking the message output time.

980

sha driver does not exist.

The virtual driver is not installed.

Check whether the GLS package is installed.
# rpm -qi kmod-FJSVhanet-drv

981

hanetctld does not exist.

The control daemon is not running.

Check whether the GLS package (FJSVhanet) is installed. Also, check that the system has been rebooted after installation.
# rpm -qi FJSVhanet
# pgrep hanetctld

987

configuration is invalid.

Failed to switch virtual networks on the virtual machine.

Review the setting referenced in the message.

988

The virtual network link operation failed.

Failed to switch virtual networks on the virtual machine.

Make sure that the system, the Redundant Line Control Function, and the cluster system are correctly set. If the same phenomenon occurs, collect materials for the examination of the Redundant Line Control Function and the cluster system, and then contact field engineers to report the error message.

989

The virtual network link operation ended normally.

Successfully switched virtual networks on the virtual machine.

No action is required.

990

line status changed: all lines disabled: (devicename: interface1=Down, interface2=Down, ...)

In Fast switching mode, it is not possible to continue communicating with the other end host because all physical interfaces (interfaceN) bundled by a virtual interface in operation (devicename) became Down.

Check if or not there is any error in a transfer route of communication to the other end host for all physical interfaces.

991

line status changed: some lines in operation: (devicename: interface1=[Up|Down], interface2=[Up|Down], ...)

In Fast switching mode, part of the physical interfaces (interfaceN) bundled by a virtual interface in operation (devicename) became Down (or Up).

Check if or not there is any error in a transfer route of communication to the other end host for physical interfaces in Down status.

992

line status changed: all lines enabled: (devicename: interface1=Up, interface2=Up, ...)

In Fast switching mode, all physical interfaces (interfaceN) bundled by a virtual interface in operation (devicename) became Up and communication with the other end host recovered.

No action is required.

993

link down detected: Primary polling failed. (ifname,target=pollip)

Link is down for the primary interface in use.

ifname: interface name

polip: monitoring destination address

Check the link state based on the execution results of the /usr/sbin/ip addr show ifname command (LOWER_UP flag displayed) and the /sbin/ethtool ifname command ("Link detected: yes" displayed). If the link is down, check whether the neighboring switch works, and whether the speed settings (auto negotiation, full-duplex, etc) for the switch and server are correctly set.

994

link down detected: Secondary polling failed. (ifname,target=pollip)

Link is down for the primary interface in use.

ifname: interface name

polip: monitoring destination address

Check the link state based on the execution results of the /usr/sbin/ip addr show ifname command (LOWER_UP flag displayed) and the /sbin/ethtool ifname command ("Link detected: yes" displayed). If the link is down, check whether the neighboring switch works, and the speed settings (auto negotiation, fullduplex, etc) for the switch and server are correctly set.

995

failed to start daemon.

Control daemon of GLS failed to be started.

Restart the redundant line control function (/opt/FJSVhanet/usr/sbin/resethanet -s) for the restoration. If the restoration fails, reboot the system.

996

polling status changed: Primary polling recovered.(ifname,target=pollip)

Primary monitoring has recovered.

ifname: interface name

pollip: monitoring destination address

No action is required.

GLS: Global Link Services