This section explains the meaning and the action to take for each message output by Redundant Line Control function if startup of the cluster system fails.
Cluster system logs are stored in the following directories:
For details on each log file (switchlog, appX.log), see "PRIMECLUSTER Reliant Monitor Services (RMS) with Wizard Tools Configuration and Administration Guide."
/var/opt/SMAWRrms/log |
Message number | Message | Meaning | Action |
---|---|---|---|
- | (Gls): ERROR: virtual interface resource not found. | There is no resource setting. | Pay attention to the following points and make sure that the system, the Redundant Line Control Function, and the cluster system are correctly set. - Ensure that the setting of the takeover IP address is identical in each node of the cluster which takes over the IP address. - For NIC switching mode, ensure that the ping monitoring is set. - If a host name is used in GLS, ensure that host name is already recorded in /etc/hosts. - Ensure that the IP address setting of RMS Wizard is identical to that of the GLS takeover IP address. If those settings are not correct, see the following sections to configure the settings correctly. After that, reboot the system or execute resethanet -s. "3.5 Deleting configuration information" "5.2 Configuration for Cluster system" If those settings are correct or the same phenomenon still occurs after configuring the settings, collect materials for the examination of the Redundant Line Control Function and the cluster system, and then contact field engineers to report the error message. |
- | (Gls): ERROR: GdBegin failed. (rsc_name, host_name) | Failed to activate the Gls detector. rsc_name: Resource name of the cluster host_name: Takeover virtual IP address (host name) | |
- | online request failed.(errno) | Failed to activate the Gls resource in the online or standby state. 19: An appropriate is not recognized by GLS. 201: Failed to activate the physical interface. 203: Failed to activate the takeover virtual interface. | Pay attention to the following points and make sure that the system, the Redundant Line Control Function, and the cluster system are correctly set. - Ensure that the setting of the takeover IP address is identical in each node of the cluster which takes over the IP address. - For NIC switching mode, ensure that the ping monitoring is set. - If a host name is used in GLS, ensure that host name is already recorded in /etc/hosts. - Ensure that the IP address setting of RMS Wizard is identical to that of the GLS takeover IP address. - Ensure that the network settings of the operating system (such as the setting of ifcfg-ethX or deactivation of HOTPLUG) are correct. For the network settings, see "3.2.2.1 Setup common to modes." If those settings are not correct, see the following sections to configure the settings correctly. After that, reboot the system or execute resethanet -s. "3.5 Deleting configuration information" "5.2 Configuration for Cluster system" If those settings are correct or the same phenomenon still occurs after configuring the settings, collect materials for the examination of the Redundant Line Control Function and the cluster system, and then contact field engineers to report the error message. |
GLS: Global Link Services