Top
PRIMECLUSTER Global Link Services Configuration and AdministrationGuide 4.6Redundant Line Control Function
FUJITSU Software

A.1 Messages Displayed by Redundant Line Control Function

This section explains the meaning of, and action to take for each message output by Redundant Line Control Function regarding such commands as the configuration commands and operation commands.

Each message has the following format:

[Output message]

  1. A format for information messages and error output messages:

    hanet: BBBCC: DDDDD: EEEEE FFFFF
     (1)    (3)    (4)    (5)   (6) 
  2. A format for console output messages:

    hanet: AAAAA: BBBCC EEEEE FFFFF
     (1)    (2)    (3)   (5)   (6) 

(1) Component name

Always begins with "hanet".

(2) Error Kind

Included in the console messages. AAAAA provides the following information:

ERROR:

Error message

WARNING:

Warning message

INFO:

Information message.

(3) Message number (Displayed in total five digits.)

Outputs an output message with a unique number. Not displayed when output an internal message.

The first three digits (BBB) indicate the message number.
The last two digits (CC) indicate the internal code.

(4) Outline of errors

The output information (DDDDD) is as follows. Not output when it is a console message.

information:

Means that an output message is the information.

warning:

Means that there is an error in the definition information (a process continues).

operation error:

Means that the executed command method has an error.

configuration error:

Means that there is an error in the definition information.

internal error:

Means that there is a fatal error.

(5) Error details

Message may be output as required.

(6) Others

The complimentary information (FFFFF) is occasionally output if necessary.