Top
PRIMECLUSTER Global Link Services Configuration and AdministrationGuide 4.6Redundant Line Control Function
FUJITSU Software

1.1.1 Functional comparison

Table 1.1 Function comparison (1) and Table 1.2 Function comparison (2) compare the functions of each network switching mode.

Table 1.1 Function comparison (1)

Function

Redundant line switching mode

Fast switching mode

NIC switching mode

Network control

Makes both of redundant transmission routes active and uses them concurrently. A stream of data is sent on a TCP connection.

Activates and uses one redundant transmission route exclusively and deactivates the other route. If the transmission route is not multiplexed, used the route as it is active.

Fault monitoring

Detectable failures

NIC, cable, switch/HUB, remote host (system down etc.)

NIC, cable, switch/HUB

Fault monitoring

Monitoring method

Monitors framework between the NIC of the host and that of the remote host. If the frame communication is disrupted, a transmission route failure will be detected.

Monitoring can be done by combining the following 2 monitoring functions.

  • Monitors switch/HUB using the ping command:
    If there is no response for a certain period of time, a transmission route failure will be detected.

  • Monitors link status of NIC:
    If the NIC is link down, a transmission route failure will be detected.

Failure detection time

5 to 10 seconds (Default)

  • When an error is detected by ping:
    22 to 27 seconds
    (Default)

  • When a NIC link down is detected:
    Using ping monitoring at the same time: 2 to 7 seconds (Default)
    Using ping monitoring not at the same time: 1 to 6 seconds (Default)

Recovery monitoring

Monitoring recovery method

Monitors framework between the NIC of the host and that of the remote host. If the frame communication is disrupted, a transmission route failure will be detected.

If a monitoring framework is sent from a standby NIC to an operating NIC, and the standby NIC receives a reply from the operating NIC within a specified time, transmission route recovery will be detected.

Recovery detection time

1 to 5 seconds (Default)

1 to 30 seconds (Default)

Fault monitoring
start/stop

Automatically starts along with virtual interface activation and stops along with its deactivation.

Automatically starts along with virtual interface activation and stops along with its deactivation.
Manual startup or stop of fault monitoring is also allowed with the operational command.

Line switching

Switchover

Automatically disconnects a failed transmission route and uses the other transmission route.
Manual disconnection of the failed route is also allowed with the operational command.

Automatically deactivates NIC of a failed transmission route and activates a standby NIC.
Manual switching operation is also allowed with the operational command.

Switchback

If a failed transmission route is recovered, it will automatically rejoin an ongoing operation.
Manual disconnection of the failed route is also allowed with the operational command.

If a failed transmission route is recovered, it will automatically rejoin operation as a standby NIC.
Manual rejoining is also allowed with the operational command.

Conditions

Remote hosts

PRIMEQUEST, PRIMERGY, SPARC M10, SPARC Enterprise, PRIMEPOWER, and other systems where GLS's Fast switching mode is running

Arbitrary host

IP address

IPv4 address, IPv6 address

IPv4 address, IPv6 address

GLS: Global Link Services

Table 1.2 Function comparison (2)

Function

Redundant line switching mode

Virtual NIC mode

GS linkage mode

Network control

Activates and uses one redundant transmission route exclusively and deactivates the other route.

Makes both of redundant transmission routes active and uses them concurrently. A stream of data is sent on a TCP connection.

Fault monitoring

Detectable failures

NIC, cable, switch/HUB

NIC, cable, HUB, router, remote host (system failure, etc)

Fault monitoring

Monitoring method

Link status monitoring:
Monitors the link status of a physical NIC. If the link is down, the line is considered to be faulty.

Network monitoring:
Monitors the connectivity between active NIC/standby NIC and switch/HUB. If no response is received within a specified period of time, the line is considered to be faulty.

Monitors a remote host using the ping command. If the communication is disrupted, a transmission route failure will be detected.

Failure detection time

  • When a NIC link down is detected (Link status monitoring):
    About 1 second

  • Network monitoring:
    14 to 17 seconds (Default)

25 to 30 seconds. (Default)

Recovery monitoring

Recovery monitoring method

If a monitoring framework is sent from a standby NIC to an operating NIC, and the standby NIC receives a reply from the operating NIC, transmission route recovery will be detected.

Monitors a remote host using the ping command. If the system receives a reply from the remote host within a specified time, transmission route recovery will be detected.

Detectable recovery time

3 to 5 seconds. (Default)

1 to 5 seconds. (Default)

Fault monitoring
start/stop

Automatically starts along with virtual interface activation and stops along with its deactivation.
Manual startup or stop of fault monitoring is also allowed with the operational command.

Automatically starts along with virtual interface activation and stops along with its deactivation.

Manual startup or stop of fault monitoring is also allowed with the operational command.

Line switching

Switchover

Automatically deactivates NIC of a failed transmission route and activates a standby NIC.
Manual switching operation is also allowed with the operational command.

Automatically disconnects a failed transmission route and uses the other transmission route.
Manual switching operation is not supported.

Switchback

If a failed transmission route is recovered, it will automatically rejoin operation as a standby NIC.
Manual rejoining is also allowed with the operational command.

If a failed transmission route is recovered, it will automatically join communication.
Manual rejoining is not supported.

Conditions

Remote hosts

Arbitrary host

GS (Global Server), PRIMEQUEST, PRIMERGY

IP addresses

IPv4 address, IPv6 address

IPv4 address