8.2.7 Configuring BIOS Settings of Managed Servers


The following BIOS configurations must be modified.

System BIOS

This is the system BIOS for a managed server.
Enable or disable and FC-HBA BIOS as appropriate, and set up the appropriate boot order.

Note

  • The BIOS settings of server blades include an option to automatically start up servers when their enclosing chassis is powered on. For details, refer to the server blade manual.

  • For PRIMERGY BX900/BX400, when a PG-LND203 is mounted as the LAN expansion card of the server blade, do not set the NIC of the LAN expansion card as [disable] in the server blade's BIOS settings.
    The connections between server blades and LAN switch blades are not shown correctly, when [disable] is set.
    The following functions do not operate correctly.

    • Changing and setting the VLAN for LAN switch blades (internal and external ports)

    • Server switchover (changing network settings while a server is switched over)

  • For PRIMERGY BX900/BX400 series, if "UEFI" and "Legacy" are displayed when configuring boot settings from the network interface, select [Legacy].

  • Set PXE VLAN Support to [Disabled] when the server switchover method is HBA address rename.

FC-HBA BIOS

This is a BIOS setting that relates to FC-HBAs that have been installed as an expansion card in the blade server.
Enable or disable SAN boot as well as the connection of a SAN storage environment by means of a Fibre Channel switch.


Configure the following settings depending on the operating environment.