Refer to the management controller (XSCF) manual to apply the settings chosen in "8.1.5 Setting Values for SPARC Enterprise M4000/M5000/M8000/M9000 and SPARC M10-4S/M12-2S/M12-2S" to configure the following on the IPMI controller.
Note that the SNMP community must be set to Write (read and write) access.
Admin IP address (IP address of the remote management controller)
User name
Password
SNMP community name
SNMP trap destination
This must be the IP address of the admin server.
Refer to the instructions given in the XSCF manual and enable the following functions.
SNMP Agent (Also enable SP_MIB)
SSH Service
HTTPS Service
Domain Autoboot
Note
For SNMP settings in XSCF, enable SNMPv1 communication.
Set as follows to automatically start up the OS when powering on.
Set the "Autoboot" of the Domain Mode to "on".
Set the mode switch of the operator panel to "Locked".