7.3.5 ILOM

ILOM shutdown agent is the shutdown agent for SPARC Enterprise T5120, T5220, T5140, T5240, T5440 series, and SPARC T3, T4, T5, T7, S7 series.

Setup and configuration

The ILOM must be configured according to the directions below:

Moreover, you must set the user name and password to allow the operation in ILOM.

When using ILOM, check the configuration of ILOM by referring to "5.1.2.3.1 Checking Console Configuration" of the "PRIMECLUSTER Installation and Administration Guide."

Shutdown Agent

There are two kinds of ILOM SAs:

The ILOM log file is as follows:

/var/opt/SMAWsf/log/SA_ilomp.log
/var/opt/SMAWsf/log/SA_ilomr.log

Note

  • The IP address of ILOM belongs to the same segment as the Administrative LAN.

    However, if the network routing is configured, the IP address of ILOM does not need to belong to the same segment as the Administrative LAN of the cluster node.

  • If ILOM is used for the console, the No.7040 error message might appear on the other nodes in the following cases:

    • Turning off a node for maintenance

    • Changing the network configuration of ILOM

    • Updating the ILOM firmware

    If the error message is displayed, take corrective action of the No.7040 error message after each operation is completed.

  • After Shutdown Facility (SF) startup, it can take up to 30 seconds to detect hardware failures such as ILOM errors or a disconnected cable, and setting errors like incorrect IP addresses.