Event traps are messages reported from a device. If you have any questions about the message contents, refer to the relevant hardware manual to take corrective actions.
Notification of Component Blockage
Target | Level | Event Display | Remarks |
---|---|---|---|
CM Unit | Error | P 010tMM00 CM#MM Fault | t : Type (1 - 3) |
CM Mantaray SP | Error | P 030tMMnn CM#MM DMA PORT Alarm | t : Type (1 - 3) |
CM DI NP | Error | P 040tMMnn CM#MM DI Alarm | t : Type (1 - 3) |
CM DI SP | Error | P 0500MMnn CM#MM DI PORT Alarm | MM : Module ID (10 - 17) |
CM SMC | Error | P 0600MM00 CM#MM SMC Alarm | MM : Module ID (10 - 11) |
CM MMC | Error | P 0700MM00 CM#MM MMC Alarm | MM : Module ID (10 - 17) |
CM DI SP/Path | Error | P 0A00MMnn CM#MM DI PORT/PATH Alarm | MM : Module ID (10 - 11) |
CM Memory:512MB | Error | P 0B1tMMnn CM#MM MEMORY(512MB) Fault | t : Type (1 - 2) |
CM Memory:1GB | Error | P 0B2tMMnn CM#MM MEMORY(1024MB) Fault | t : Type (1 - 2) |
CM Memory:2GB | Error | P 0B4tMMnn CM#MM MEMORY(2048MB) Fault | t : Type (1 - 2) |
CM Memory:4GB | Error | P 0B8tMMnn CM#MM MEMORY(4096MB) Fault | t : Type (1 - 2) |
Compact Flash | Error | P 0C0tMM00 CM#MM COMPACT FLASH Fault | t : Type (1 - 3) |
CM FAN UNIT | Error | P 0D00MM00 CM#MM FAN UNIT Fault | MM : Module ID (10 - 17) |
CA | Error | P 10ttMM00 CA#MM (on CM#XX) CaType Fault | tt : Type (00 - 19) |
CA Port | Error | P 11ttMMnn CA#MM (on CM#XX) CaType PORT Alarm | tt : Type (00 - 19) |
SFP Optical Shortwave | Error | P 1AttMMnn CA#MM (on CM#XX) CaType SFP OPTICAL SHORTWAVE Fault | tt : Type (00 - 1D) |
SFP Optical Longwave | Error | P 1BttMMnn CA#MM (on CM#XX) CaType SFP OPTICAL LONGWAVE Fault | tt : Type (00, 18) |
XFP (UndefCA) | Error | P 1CttMMnn CA#MM (on CM#XX) CaType XFP Fault | tt : Type (00 - 0F) |
SFP+ Optical Shortwave | Error | P 1CttMMnn CA#MM (on CM#XX) CaType SFP+ OPTICAL SHORTWAVE Fault | tt : Type (00 - 09) |
SFP Optical Longwave | Error | P 1DttMMnn CA#MM (on CM#XX) CaType SFP OPTICAL LONGWAVE Fault | tt : Type (00 - 06) |
SFP Unknown | Error | P 1FttMMnn CA#MM (on CM#XX) SFP Type Unknown Fault | tt : Type (03 - 06) |
FRT | Error | P 400tMM00 FRT Fault | t : Type (0, 1) |
BRT | Error | P 5000MM00 BRT Fault | MM : Module ID (B0 - B7) |
BRT Port/Path | Error | P 5100MMnn BRT PORT/PATH Alarm | MM : Module ID (B0 - B7) |
SFP Optical Shortwave (BRT) | Error | P 5A00MMnn BRT SFP OPTICAL SHORTWAVE Fault | MM : Module ID (B0 - B7) |
SVC | Error | P 6000MM00 SVC Fault | MM : Module ID (E0 - E1) |
CE FAN UNIT | Error | P 710tnn00 CE FAN UNIT Fault | t : Type (1, 2) |
OPNL UNIT | Error | P 720t0000 PANEL UNIT Fault | t : Type (1, 2) |
CPSU | Error | P 730tnn00 CPSU Fault | t : Type (1, 2) |
SCCI | Error | P 740tnn00 SCCI CABLE Fault | t : Type (1, 2) |
BCU | Error | P 7500nn00 BCU Fault | nn : Slot number |
BTU | Error | P 760tnn00 BTU Fault | t : Type (1, 2) |
BBU Signal CABLE | Error | P 7700MM00 BBU SIG CABLE Fault | MM : Module ID(10-11) |
3.5 Inch DISK | Error | P 80ttDDnn PP xxGB DISK(ccccccc) DE#DD/Slot#nn Fault | tt : Type |
3.5 Inch Disk (Failed Usable) | Error | P 80ttDDnn PP xxGB DISK(ccccccc) DE#DD/Slot#nn FailedUse | tt : Type |
3.5 Inch Disk (DISK performance abnormal) | Error | P 80ttDDnn PP xxGB DISK(ccccccc) DE#DD/Slot#nn Slowdown | tt : Type |
3.5 Inch DISK (Compare Error) | Error | P 88ttDDnn PP xxGB DISK(ccccccc) DE#DD/Slot#nn Fault | tt : Type |
2.5 Inch DISK | Error | P 81ttDDnn PP xxGB DISK(ccccccc) DE#DD/Slot#nn Fault | tt : Type |
2.5 Inch Disk (Failed Usable) | Error | P 81ttDDnn PP xxGB DISK(ccccccc) DE#DD/Slot#nn FailedUse | tt : Type |
2.5 Inch DISK (Compare Error) | Error | P 88ttDDnn PP xxGB DISK(ccccccc) DE#DD/Slot#nn Fault | tt : Type |
3.5 Inch SATA DISK | Error | P 82ttDDnn PP xxGB DISK(ccccccc) DE#DD/Slot#nn Fault | tt : Type |
3.5 Inch SATA Disk (Failed Usable) | Error | P 82ttDDnn PP xxGB DISK(ccccccc) DE#DD/Slot#nn FailedUse | tt : Type |
3.5 Inch SATA Disk (Compare Error) | Error | P 88ttDDnn PP xxGB DISK(ccccccc) DE#DD/Slot#nn Fault | tt : Type |
Solid State Drive | Error | P 84ttDDnn PP xxGB DISK(ccccccc) DE#DD/Slot#nn Fault | tt : Type |
Solid State Drive (Failed Usable) | Error | P 84ttDDnn PP xxGB DISK(ccccccc) DE#DD/Slot#nn FailedUse | tt : Type |
Solid State Drive (Compare Error) | Error | P 84ttDDnn PP xxGB DISK(ccccccc) DE#DD/Slot#nn Fault | tt : Type |
PBC (15DE) | Error | P 9001DD0N PBC Fault | DD : DE ID |
PBC (30DE) | Error | P 9002DD0N PBC Fault | DD : DE ID |
PBC Port | Error | P 9100DDNn PBC PORT Alarm | DD : DE ID |
SFP Optical Shortwave (PBC) | Error | P 9A00DDNn PBC SFP OPTICAL SHORTWAVE Fault | DD : DE ID |
SFP Copper (PBC) | Error | P 9B00DDNn PBC SFP COPPER Fault | DD : DE ID |
DEI CABLE | Error | P 9C00DD0N DEI CABLE Fault | DD : DE ID |
30 DE FAN UNIT | Error | P D100DD00 DE FAN UNIT Fault | DD : DE ID |
DPSU (15DE) | Error | P D20tDD0N DPSU Fault | t : Type (1 - 3) |
BBU CABLE | Error | P D300DD0N BBU CABLE Fault | DD : DE ID |
Warning (Temperature Alarm)
Target | Level | Event Display | Remarks |
---|---|---|---|
CE exhaust temperature alarm (FATAL) | Error | P 7A00EEEE CE OUT TEMP | EEEE : Position information |
CE exhaust temperature alarm (WARNING) | Warning | J 7A00EEEE CE OUT TEMP | EEEE : Position information |
CE intake air temperature alarm (WARNING) | Warning | J 7B00EEEE CE IN TEMP | EEEE : Position information |
DE exhaust temperature alarm (FATAL) | Error | P DA00EEEE DE OUT TEMP | EEEE : Position information |
DE exhaust temperature alarm (Sensor trouble) | Error | P DA00EEEE DE OUT TEMP | EEEE : Position information |
DE exhaust temperature alarm (WARNING) | Warning | J DA00EEEE DE OUT TEMP | EEEE : Position information |
DE intake air temperature alarm (Sensor trouble) | Error | P DB00EEEE DE IN TEMP | EEEE : Position information |
DE intake air temperature alarm (WARNING) | Warning | J DB00EEEE DE IN TEMP | EEEE : Position information |
Warning (Expiration)
Target | Level | Event Display | Remarks |
---|---|---|---|
Six months before battery life expiration | Warning | J 7006nn00 BATTERY N 6MONTH WARNING YYYY/MM | nn : Slot number |
One week before battery life expiration | Warning | J 7007nn00 BATTERY N 1WEEK WARNING YYYY/MM | nn : Slot number |
N day before battery life expiration | Warning | J 7007nn00 BATTERY N zDAY WARNING YYYY/MM | nn : Slot number |
Battery life expiration | Error | J 70FEnn00 BATTERY N EXPIRATION ALARM YYYY/MM | nn : Slot number |
Warning (Other)
Target | Level | Event Display | Remarks |
---|---|---|---|
CM Check1 | Warning | J C1MM0000 CM#MM Check-1 | MM : Module ID (10 - 17) |
CA Check1 | Warning | J C1MM0000 CA#MM Check-1 | MM : Module ID (40 - 4F, , , 70 - 7F) |
Frequent occurrence of a correctable memory error:512MB | Warning | J C31tMMnn CM#MM MEMORY(512MB) Correctable Error | t : Type (1, 2) |
Frequent occurrence of a correctable memory error:1GB | Warning | J C32tMMnn CM#MM MEMORY(1024MB) Correctable Error | t : Type (1, 2) |
Frequent occurrence of a correctable memory error:2GB | Warning | J C34tMMnn CM#MM MEMORY(2048MB) Correctable Error | t : Type (1, 2) |
Frequent occurrence of a correctable memory error:4GB | Warning | J C38tMMnn CM#MM MEMORY(4096MB) Correctable Error | t : Type (1, 2) |
CM warning (statistics/other) | Warning | J 01ttEEEE CM#MM Warning | tt : Type |
CM Warning (MCE Correctable) | Warning | J 01ttEEEE CM#MM MCE Correctable Error | tt : Type |
CM Warning (FAN) | Warning | J 01ttEEEE CM#MM FAN Alarm | tt : Type |
CM Warning (IN TEMP ALARM) | Warning | J 01ttEEEE CM#MM IN TEMP Alarm | tt : Type |
CM Warning (IN TEMP SENSOR) | Warning | J 01ttEEEE CM#MM IN TEMP SENSOR Alarm | tt : Type |
CM Warning (RTC ALARM) | Warning | J 01ttEEEE CM#MM RTC Alarm | tt : Type |
CF Warning | Warning | J 0C0tMM00 CM#MM COMPACT FLASH Warning | t : Type (1 - 3) |
CA Warning (Undefined) | Warning | J 10ttMM00 CA#MM (on CM#XX) CaType Warning | tt : Type (00 - 19) |
FRT Warning | Warning | J 400tMM00 FRT Warning | t : Type (1, 2) |
BRT Warning | Warning | J 5000MM00 BRT Warning | MM : BRT Module ID (B0 - B7) |
SMART notification from a disk (3.5-inch) | Warning | J 80ttEEEE PP xxxGB DISK(ccccccc) DE#DD/Slot#nn SMART | tt : Type |
SMART: Preventive disk disconnection (3.5-inch) | Warning | J 80ttEEEE PP xxxGB DISK(ccccccc) DE#DD/Slot#nn Warning | tt : Type |
SMART: Disk performance abnormal (3.5-inch) | Warning | J 80ttEEEE PP xxxGB DISK(ccccccc) DE#DD/Slot#nn WarnSlow | tt : Type |
Detection notification of disk performance abnormal (3.5-inch) | Warning | J 80ttEEEE PP xxxGB DISK(ccccccc) DE#DD/Slot#nn Slowdown | tt : Type |
SMART notification from a disk (2.5-inch) | Warning | J 81ttEEEE PP xxxGB DISK(ccccccc) DE#DD/Slot#nn SMART | tt : Type |
SMART: Preventive disk disconnection (2.5-inch) | Warning | J 81ttEEEE PP xxxGB DISK(ccccccc) DE#DD/Slot#nn Warning | tt : Type |
SMART notification from a SATA disk (3.5-inch) | Warning | J 82ttEEEE PP xxxGB DISK(ccccccc) DE#DD/Slot#nn SMART | tt : Type |
SMART: Preventive SATA disk disconnection (3.5-inch) | Warning | J 82ttEEEE PP xxxGB DISK(ccccccc) DE#DD/Slot#nn Warning | tt : Type |
SVC Alarm (Warning Level) | Warning | J 6000MM00 SVC | MM : Module ID |
SMC Alarm (Warning Level) | Warning | J 0600MM00 CM SMC | MM : Module ID |
PBC Alarm (Warning Level) | Warning | J 9001EEEE PBC 15DE | EEEE : Position information |
PBC Alarm (Warning Level) | Warning | J 9002EEEE PBC 30DE | EEEE : Position information |
Event Notification (M Messages)
Target | Level | Event Display | Remarks |
---|---|---|---|
Write Bad Data | Error | M E0050xxx WRITE BAD DATA | xxx : RLU number |
PINNED Data | Error | M E10300MM PINNED DATA | MM : CM Module ID where PINNED occurred |
NRDY (cause 01) | Error | M E2070001 NOT READY(01:Configuration Error) | |
NRDY (cause 02) | Error | M E2070002 NOT READY(02:CM F/W Version Error) | |
NRDY (cause 04) | Error | M E2070004 NOT READY(04:Restore Fail) | |
NRDY (cause 08) | Error | M E2070008 NOT READY(08:Basic Set Online(Normal) Error) | |
NRDY (cause 09) | Error | M E2070009 NOT READY(09:Maintenance Set Online Error) | |
NRDY (cause 11) | Error | M E207000B NOT READY(11:Power Off/Fail Incomplete) | |
NRDY (cause 12) | Error | M E207000C NOT READY(12:Backup Fail) | |
NRDY (cause 13) | Error | M E207000D NOT READY(13:Multi CM Down) | |
NRDY (cause 14) | Error | M E207000E NOT READY(14:Machine Down Recovery End) | |
NRDY (cause 15) | Error | M E207000F NOT READY(15:Machine Down Recovery Failed) | |
NRDY (cause 16) | Error | M E2070010 NOT READY(16:DE Build Error) | |
NRDY (cause 17) | Error | M E2070011 NOT READY(17:CM Memory Shortage) | |
NRDY (cause 18) | Error | M E2070012 NOT READY(18:PBC Combination Error) | |
NRDY (cause 19) | Error | M E2070013 NOT READY(19:FRT Fault) | |
NRDY (cause 20) | Error | M E2070014 NOT READY(20:BRT Fault) | |
Successful FC recovery | Error | M E406C0DD FC Loop Recovery Completed | DD : Lower DE number |
Unsuccessful FC loop recovery | Error | M E406F0DD FC Loop Recovery Failed | DD : Lower DE number |
Rebuilding to HS completed (bad data included) | Error | M 21810xxx RAID Group#0xxx REBUILD to HS (Recovered end) | xxx : RLU number |
Rebuilding to DV completed (bad data included) | Error | M 21810xxx RAID Group#0xxx REBUILD to DV (Recovered end) | xxx : RLU number |
Disconnected intra-cabinet path | Error | M 0732MMnn Remote Copy Path (MID#MM PORT#nn) Not Available | MM : Module ID |
REC automatic HALT occurrence | Error | M 13CF11xx REC Automatic HALT or ERROR occurred.(xx) | xx : 00 is path error, 01 heavy load, 02 ERROR |
Use capacity of Pool has changed. | Warning | M E8010xxx Pool#xxx turned to CAUTION (decrease of available capacity) | xxx : Thin Provisioning Pool number (hexadecimal notation) |
Use capacity of Pool has changed. | Warning | M E8020xxx Pool#xxx turned to WARNING (decrease of available capacity) | xxx : Thin Provisioning Pool number (hexadecimal notation) |
Use capacity of Pool has changed. | Warning | M E8010xxx Pool#xxx returned to CAUTION(decrease of available capacity) | xxx : Thin Provisioning Pool number (hexadecimal notation) |
Use capacity of Pool has changed. | Information | M E8040xxx Pool#xxx returned to NORMAL(increase of available capacity) | xxx : Thin Provisioning Pool number (hexadecimal notation) |