Top
ETERNUS SF Express V16.3 / Storage Cruiser V16.3 Event Guide
FUJITSU Storage

4.1 ETERNUS DX60/DX60 S2/DX80/DX90

Event traps are messages reported from a device. If you have any questions about the message contents, refer to the relevant hardware manual to take corrective actions.

Notification of Component Blockage

Target

Level

Event Display

Remarks

CM Unit

Error

P 01SSMM00 Controller Module#m(zz xxHz) Fault <pp ss rr>

SS : Parts subtype
MM : Module ID (10 - 11)
m : CM number
zz : Model (FC/SAS/iSCSI)
xx : Frequency (800MHz/1.2GHz)
pp : Parts number
ss : Serial number
rr : Revision

CM BE Expander

Error

P 06SSMM00 Controller Module#m(zz xxHz) BE Expander Fault <pp ss rr>

SS : Parts subtype
MM : Module ID (10 - 11)
m : CM number
zz : Model (FC/SAS/iSCSI)
xx : Frequency (800MHz/1.2GHz)
pp : Parts number
ss : Serial number
rr : Revision

CM DI PORT

Error

P 08SSMM0n Controller Module#m(zz xxHz) DI Port#n Fault <pp ss rr>

SS : Parts subtype
MM : Module ID (10 - 11)
n : Port number (0 - 1)
m : CM number
zz : Model (FC/SAS/iSCSI)
xx : Frequency (800MHz/1.2GHz)
pp : Parts number
ss : Serial number
rr : Revision

CM SAS Port

Error

P 09SSMM00 Controller Module#m(zz xxHz) SAS Port Fault <pp ss rr>

SS : Parts subtype
MM : Module ID (10 - 11)
m : CM number
zz : Model (FC/SAS/iSCSI)
xx : Frequency (800MHz/1.2GHz)
pp : Parts number
ss : Serial number
rr : Revision

CM BE Expander Port

Error

P 0ASSMM0n Controller Module#m(zz xxHz) BE Expander Port#n Fault <pp ss rr>

SS : Parts subtype
MM : Module ID (10 - 11)
n : Port number (0 - 2)
m : CM number
zz : Model (FC/SAS/iSCSI)
xx : Frequency (800MHz/1.2GHz)
pp : Parts number
ss : Serial number
rr : Revision

CM Memory

Error

P 0BSSMM00 Controller Module#m(zz xxHz) Cache(MEM) Fault <pp ss rr>

SS : Parts subtype
MM : Module ID (10 - 11)
m : CM number
zz : Model (FC/SAS/iSCSI)
xx : Frequency (800MHz/1.2GHz)
MEM: Memory capacity
pp : Parts number
ss : Serial number
rr : Revision

CM Flash ROM

Error

P 0CSSMM00 Controller Module#m(zz xxHz) Flash ROM Fault <pp ss rr>

SS : Parts subtype
MM : Module ID (10 - 11)
m : CM number
zz : Model (FC/SAS/iSCSI)
xx : Frequency (800MHz/1.2GHz)
pp : Parts number
ss : Serial number
rr : Revision

CM NAND Controller

Error

P 0ESSMM00 Controller Module#m(zz xxHz) NAND Controller Fault <pp ss rr>

SS : Parts subtype
MM : Module ID (10 - 11)
m : CM number
zz : Model (FC/SAS/iSCSI)
xx : Frequency (800MHz/1.2GHz)
pp : Parts number
ss : Serial number
rr : Revision

SCU

Error

P 0FSSMM00 Controller Module#m(zz xxHz) Super Capacitor Unit Fault <pp ss rr>

SS : Parts subtype
MM : Module ID (10 - 11)
m : CM number
zz : Model (FC/SAS/iSCSI)
xx : Frequency (800MHz/1.2GHz)
pp : Parts number
ss : Serial number
rr : Revision

CA Port

Error

P 11SSMM0n Controller Module#m(zz xxHz) Port#n Fault <pp ss rr>

SS : Parts subtype
MM : Module ID (10 - 11)
n : Port number (0 - 1)
m : CM number
zz : Model (FC/SAS/iSCSI)
xx : Frequency (800MHz/1.2GHz)
pp : Parts number
ss : Serial number
rr : Revision

CM FE Expander

Error

P 12SSMM00 Controller Module#m(zz xxHz) FE Expander Fault <pp ss rr>

SS : Parts subtype
MM : Module ID (10 - 11)
m : CM number
zz : Model (FC/SAS/iSCSI)
xx : Frequency (800MHz/1.2GHz)
pp : Parts number
ss : Serial number
rr : Revision

CM FE Expander Port

Error

P 13SSMM0n Controller Module#m(zz xxHz) FE Expander Port#n Fault <pp ss rr>

SS : Parts subtype
MM : Module ID (10 - 11)
nn : Port number (0 - 1)
xx : Frequency (800MHz/1.2GHz)
zz : Model (FC/SAS/iSCSI)
yy : Number of ports (1 - 2)
pp : Parts number
ss : Serial number
rr : Revision

SFP Optical Shortwave

Error

P 1A00MM0n FC SFP Controller Module#m Port#n Fault <pp ss rr oo>

MM : Module ID (10 - 11)
n : Port number (0 - 1)
m : CM number
pp : Parts number
ss : Serial number
rr : Revision
oo : Other Information

SFP+ Optical Shortwave

Error

P 1C00MM0n FC SFP+ Controller Module#m Port#n Fault <pp ss rr oo>

MM : Module ID (10 - 11)
n : Port number (0 - 1)
m : CM number
pp : Parts number
ss : Serial number
rr : Revision
oo : Other Information

3.5 Inch DISK

Error

P 80SSDDNN Disk Drive DE#DD-Disk#n(SAS xxxGB yykrpm cc) Fault <pp ss rr>

SS : Parts subtype
DD : DE ID
NN : Slot number (00 - 0b)
n : Slot number (00 - 11)
xxx : Disk capacity
yy : Disk rotation
cc : Disk information
pp : Parts number
ss : Serial number
rr : Revision

3.5 Inch Disk
(Failed Usable)

Error

P 80SSDDNN Disk Drive DE#DD-Disk#n(SAS xxxGB yykrpm cc) Failed Usable <pp ss rr>

SS : Parts subtype
DD : DE ID
NN : Slot number (00 - 0b)
n : Slot number (00 - 11)
xxx : Disk capacity
yy : Disk rotation
cc : Disk information
pp : Parts number
ss : Serial number
rr : Revision

3.5 Inch DISK
(Compare Error)

Error

P 88SSDDNN Disk Drive DE# DD-Disk#n(SAS xxxGB yykrpm cc) Fault <pp ss rr>

SS : Parts subtype
DD : DE ID
NN : Slot number (00 - 0b)
n : Slot number (00 - 11)
xxx : Disk capacity
yy : Disk rotation
cc : Disk information
pp : Parts number
ss : Serial number
rr : Revision

2.5 Inch DISK

Error

P 81SSDDNN Disk Drive DE#DD-Disk#n(SAS xxxGB yykrpm cc) Fault <pp ss rr>

SS : Parts subtype
DD : DE ID
NN : Slot number (00 - 17)
n : Slot number (00 - 23)
xxx : Disk capacity
yy : Disk rotation
cc : Disk information
pp : Parts number
ss : Serial number
rr : Revision

2.5 Inch Disk
(Failed Usable)

Error

P 81SSDDNN Disk Drive DE#DD-Disk#n(SAS xxxGB yykrpm cc) Failed Usable <pp ss rr>

SS : Parts subtype
DD : DE ID
NN : Slot number (00 - 17)
n : Slot number (00 - 23)
xxx : Disk capacity
yy : Disk rotation
cc : Disk information
pp : Parts number
ss : Serial number
rr : Revision

2.5 Inch DISK
(Compare Error)

Error

P 88SSDDNN Disk Drive DE# DD-Disk#n(SAS xxxGB yykrpm cc) Fault <pp ss rr>

SS : Parts subtype
DD : DE ID
NN : Slot number (00 - 17)
n : Slot number (00 - 23)
xxx : Disk capacity
yy : Disk rotation
cc : Disk information
pp : Parts number
ss : Serial number
rr : Revision

3.5 Inch DISK

Error

P 82SSDDNN Disk Drive DE#DD-Disk#n(SATA xxxGB cc) Fault <pp ss rr>

SS : Parts subtype
DD : DE ID
NN : Slot number (00 - 0b)
n : Slot number (00 - 11)
xxx : Disk capacity
cc : Disk information
pp : Parts number
ss : Serial number
rr : Revision

3.5 Inch Disk
(Failed Usable)

Error

P 82SSDDNN Disk Drive DE#DD-Disk#n(SATA xxxGB cc) Failed Usable <pp ss rr>

SS : Parts subtype
DD : DE ID
NN : Slot number (00 - 0b)
n : Slot number (00 - 11)
xxx : Disk capacity
cc : Disk information
pp : Parts number
ss : Serial number
rr : Revision

3.5 Inch DISK
(Compare Error)

Error

P 88SSDDNN Disk Drive DE# DD-Disk#n(SATA xxxGB cc) Fault <pp ss rr>

SS : Parts subtype
DD : DE ID
NN : Slot number (00 - 0b)
n : Slot number (00 - 11)
xxx : Disk capacity
cc : Disk information
pp : Parts number
ss : Serial number
rr : Revision

3.5 Inch SSD

Error

P 84SSDDNN SSD 3.5 DE#dd-Slot#n(SAS xxxGB cc) Fault <pp ss rr>

SS : Parts subtype
DD : DE ID
NN : Slot number (00 - 0b)
n : Slot number (00 - 11)
xxx : Disk capacity
cc : Disk information
pp : Parts number
ss : Serial number
rr : Revision

3.5 Inch SSD
(Failed Usable)

Error

P 84SSDDNN SSD 3.5 DE#dd-Slot#n(SAS xxxGB cc) Failed Usable <pp ss rr>

SS : Parts subtype
DD : DE ID
NN : Slot number (00 - 0b)
n : Slot number (00 - 11)
xxx : Disk capacity
cc : Disk information
pp : Parts number
ss : Serial number
rr : Revision

3.5 Inch SSD
(Compare Error)

Error

P 88SSDDNN SSD 3.5 DE#dd-Slot#n(SAS xxxGB cc) Fault <pp ss rr>

SS : Parts subtype
DD : DE ID
NN : Slot number (00 - 0b)
n : Slot number (00 - 11)
xxx : Disk capacity
cc : Disk information
pp : Parts number
ss : Serial number
rr : Revision

2.5 Inch SSD

Error

P 85SSDDNN SSD 2.5 DE#dd-Slot#n(SAS xxxGB cc) Fault <pp ss rr>

SS : Parts subtype
DD : DE ID
NN : Slot number (00 - 17)
n : Slot number (00 - 23)
xxx : Disk capacity
cc : Disk information
pp : Parts number
ss : Serial number
rr : Revision

2.5 Inch SSD
(Failed Usable)

Error

P 85SSDDNN SSD 2.5 DE#dd-Slot#n(SAS xxxGB cc) Failed Usable <pp ss rr>

SS : Parts subtype
DD : DE ID
NN : Slot number (00 - 17)
n : Slot number (00 - 23)
xxx : Disk capacity
cc : Disk information
pp : Parts number
ss : Serial number
rr : Revision

2.5 Inch SSD
(Compare Error)

Error

P 88SSDDNN SSD 2.5 DE#dd-Slot#n(SAS xxxGB cc) Fault <pp ss rr>

SS : Parts subtype
DD : DE ID
NN : Slot number (00 - 17)
n : Slot number (00 - 23)
xxx : Disk capacity
cc : Disk information
pp : Parts number
ss : Serial number
rr : Revision

EXP

Error

P 9000DD0N Expander DE#DD/EXP#N Fault <pp ss rr>

DD : DE ID
N : Side 0, side 1
pp : Parts number
ss : Serial number
rr : Revision

EXP Port

Error

P 9100DDNn Expander Port DE#DD/EXP#N/Port#n Fault <pp ss rr>

DD : DE ID
N : Side 0, side 1
n : Port number (0 - 1)
pp : Parts number
ss : Serial number
rr : Revision

PSU

Error

P D200DD0n Power Supply Unit DE#DD/PSU#n Fault <pp ss rr>

DD : DE ID
n : Slot number (0 - 1)
pp : Parts number
ss : Serial number
rr : Revision

Warning (Temperature Alarm)

Target

Level

Event Display

Remarks

DE Abnormal exhaust gas temperature
(FATAL)

Error

P DA0tDD00 DE Exhaust temperature DE#DD Fatal

t : Type(1=1U, 2=2U)
DD : DE ID

DE Abnormal exhaust gas temperature
(Sensor failure)

Error

P DA0tDD00 DE Exhaust temperature sensor DE#DD Fault

t : Type(1=1U, 2=2U)
DD : DE ID

DE Abnormal exhaust gas temperature
(WARNING)

Warning

J DA0tDD00 DE Exhaust temperature DE#DD Warning

t : Type(1=1U, 2=2U)
DD : DE ID

DE Abnormal intake temperature
(Sensor failure)

Error

P DB0tDD00 DE Intake temperature sensor DE#DD Fault

t : Type(1=1U, 2=2U)
DD : DE ID

DE Abnormal intake temperature
(WARNING)

Warning

J DB0tDD00 DE Intake temperature DE#DD Warning

t : Type(1=1U, 2=2U)
DD : DE ID

Warning (Other)

Target

Level

Event Display

Remarks

CM Check1

Warning

J C1MM0000 Controller Module#m(zz xxHz) Reboot <pp ss rr>

MM : Module ID (10 - 11)
m : CM number
zz : Model (FC/SAS/iSCSI)
xx : Frequency (800MHz/1.2GHz)
pp : Parts number
ss : Serial number
rr : Revision

Multiple memory collectable error

Warning

J C301MM00 Controller Module#m(zz xxHz) Cache(MEM) Correctable Error <pp ss rr>

MM : Module ID (10 - 11)
m : CM number
zz : Model (FC/SAS/iSCSI)
xx : Frequency (800MHz/1.2GHz)
MEM: Memory capacity
pp : Parts number
ss : Serial number
rr : Revision

CM Warning

Warning

J 01SSMM00 Controller Module#m(zz xxHz) Warning factor(ww) <pp ss rr>

SS : Parts subtype
m : CM number
zz : Model (FC/SAS/iSCSI)
xx : Frequency (800MHz/1.2GHz)
ww : Factor Code
pp : Parts number
ss : Serial number
rr : Revision

CM BE Expander Warning

Warning

J 06SSMM00 Controller Module##m(zz xxHz) BE Expander Warning <pp ss rr>

SS : Parts subtype
MM : Module ID (10 - 11)
m : CM number
zz : Model (FC/SAS/iSCSI)
xx : Frequency (800MHz/1.2GHz)
pp : Parts number
ss : Serial number
rr : Revision

CM SAS Port Warning

Warning

J 09SSMM0n Controller Module#m(zz xxHz) SAS Port#n Warning <pp ss rr>

SS : Parts subtype
MM : Module ID (10 - 11)
n : Port number (0 - 1)
zz : Model (FC/SAS/iSCSI)
xx : Frequency (800MHz/1.2GHz)
pp : Parts number
ss : Serial number
rr : Revision

CM BE Expander Port Warning

Warning

J 0ASSMM0n Controller Module#m(zz xxHz) BE Expander Port#n Warning <pp ss rr>

SS : Parts subtype
MM : Module ID (10 - 11)
n : Port number (0 - 2)
zz : Model (FC/SAS/iSCSI)
xx : Frequency (800MHz/1.2GHz)
pp : Parts number
ss : Serial number
rr : Revision

CM FLASH ROM

Warning

J 0CSSMM00 Controller Module#m(zz xxHz) Flash ROM Warning <pp ss rr>

SS : Parts subtype
MM : Module ID (10 - 11)
zz : Model (FC/SAS/iSCSI)
xx : Frequency (800MHz/1.2GHz)
pp : Parts number
ss : Serial number
rr : Revision

CM NAND Controller

Warning

J 0ESSMM00 Controller Module#m(zz xxHz) NAND Flash Warning <pp ss rr>

SS : Parts subtype
MM : Module ID (10 - 11)
zz : Model (FC/SAS/iSCSI)
xx : Frequency (800MHz/1.2GHz)
pp : Parts number
ss : Serial number
rr : Revision

SMART notice from Disk
(3.5inch)

Warning

J 80SSDDNN Disk Drive DE#DD-Disk#n(SAS xxxGB yykrpm cc) SMART <pp ss rr>

SS : Parts subtype
DD : DE ID
NN : Slot number (00 - 0b)
n : Slot number (00 - 11)
xxx : Disk capacity
yy : Disk rotation
cc : Disk information
pp : Parts number
ss : Serial number
rr : Revision

Disk preventative separation SMART
(3.5inch)

Warning

J 80SSDDNN Disk Drive DE#DD-Disk#n(SAS xxxGB yykrpm cc) Warning <pp ss rr>

SS : Parts subtype
DD : DE ID
NN : Slot number (00 - 0b)
n : Slot number (00 - 11)
xxx : Disk capacity
yy : Disk rotation
cc : Disk information
pp : Parts number
ss : Serial number
rr : Revision

SMART notice from Disk
(2.5inch)

Warning

J 81SSDDNN Disk Drive DE#DD-Disk#n(SAS xxxGB yykrpm cc) SMART <pp ss rr>

SS : Parts subtype
DD : DE ID
NN : Slot number (00 - 17)
n : Slot number (00 - 23)
xxx : Disk capacity
yy : Disk rotation
cc : Disk information
pp : Parts number
ss : Serial number
rr : Revision

Disk preventative separation SMART
(2.5inch)

Warning

J 81SSDDNN Disk Drive DE#DD-Disk#n(SAS xxxGB yykrpm cc) Warning <pp ss rr>

SS : Parts subtype
DD : DE ID
NN : Slot number (00 - 17)
n : Slot number (00 - 23)
xxx : Disk capacity
yy : Disk rotation
cc : Disk information
pp : Parts number
ss : Serial number
rr : Revision

SATA Disk notice from Disk
(3.5inch)

Warning

J 82SSDDNN Disk Drive DE#DD-Disk#n(SATA xxxGB cc) SMART <pp ss rr>

SS : Parts subtype
DD : DE ID
NN : Slot number (00 - 0b)
n : Slot number (00 - 11)
xxx : Disk capacity
cc : Disk information
pp : Parts number
ss : Serial number
rr : Revision

SATA Disk preventative separation SMART
(3.5inch)

Warning

J 82SSDDNN Disk Drive DE#DD-Disk#n(SATA xxxGB cc) Warning <pp ss rr>

SS : Parts subtype
DD : DE ID
NN : Slot number (00 - 0b)
n : Slot number (00 - 11)
xxx : Disk capacity
cc : Disk information
pp : Parts number
ss : Serial number
rr : Revision

SMART notice from SSD
(3.5inch)

Warning

J 84SSDDNN SSD 3.5 DE#dd-Slot#n(SAS xxxGB cc) SMART <pp ss rr>

SS : Parts subtype
DD : DE ID
NN : Slot number (00 - 0b)
n : Slot number (00 - 11)
xxx : Disk capacity
cc : Disk information
pp : Parts number
ss : Serial number
rr : Revision

SSD preventative separation SMART
(3.5inch)

Warning

J 84SSDDNN SSD 3.5 DE#dd-Slot#n(SAS xxxGB cc) Warning <pp ss rr>

SS : Parts subtype
DD : DE ID
NN : Slot number (00 - 0b)
n : Slot number (00 - 11)
xxx : Disk capacity
cc : Disk information
pp : Parts number
ss : Serial number
rr : Revision

SMART notice from SSD
(2.5inch)

Warning

J 85SSDDNN SSD 2.5 DE#dd-Slot#n(SAS xxxGB cc) SMART <pp ss rr>

SS : Parts subtype
DD : DE ID
NN : Slot number (00 - 17)
n : Slot number (00 - 23)
xxx : Disk capacity
cc : Disk information
pp : Parts number
ss : Serial number
rr : Revision

SSD preventative separation SMART
(2.5inch)

Warning

J 85SSDDNN SSD 2.5 DE#dd-Slot#n(SAS xxxGB cc) Warning <pp ss rr>

SS : Parts subtype
DD : DE ID
NN : Slot number (00 - 17)
n : Slot number (00 - 23)
xxx : Disk capacity
cc : Disk information
pp : Parts number
ss : Serial number
rr : Revision

EXP Alarm
(Warning Level)

Warning

J 9000DD0N Expander DE#DD/EXP#n Warning <pp ss rr>

DD : DE ID
N : Side 0, side 1
pp : Parts number
ss : Serial number
rr : Revision

EXP Port
(Warning Level)

Warning

J 9100DDNn Expander Port DE#DD/EXP#N/Port#n Warning <pp ss rr>

DD : DE ID
N : Side 0, side 1
n : Port number (0 - 1)
pp : Parts number
ss : Serial number
rr : Revision

Event Notification (M Messages)

Target

Level

Event Display

Remarks

Write Bad Data

Error

M E0050xxx WRITE BAD DATA

xxx : RLU number

PINNED Data

Error

M E10300MM PINNED DATA

MM : CM Module ID where PINNED occurred

NRDY (Factor 01)

Error

M E2070001 NOT READY(01:Configuration Error)

NRDY (Factor 02)

Error

M E2070002 NOT READY(02:CM F/W Version Error)

NRDY (Factor 04)

Error

M E2070004 NOT READY(04:Restore Fail)

NRDY (Factor 11)

Error

M E207000B NOT READY(11:Power Off/Fail Incomplete)

NRDY (Factor 12)

Error

M E207000C NOT READY(12:Backup Fail)

NRDY (Factor 13)

Error

M E207000D NOT READY(13:Multi CM Down)

NRDY (Factor 14)

Error

M E207000E NOT READY(14:Machine Down Recovery End)

NRDY (Factor 15)

Error

M E207000F NOT READY(15:Machine Down Recovery Failed)

NRDY (Factor 16)

Error

M E2070010 NOT READY(16:DE Build Error)

NRDY (Factor 17)

Error

M E2070011 NOT READY(17:CM Memory Shortage)

NRDY (Factor 21)

Error

M E2070015 NOT READY(21:Configuration Data restored from System Disk)

NRDY (Factor 22)

Error

M E2070016 NOT READY(22:No Version)

End of rebuild to HS
(Bad Data)

Error

M 21810xxx RAID Group#0xxx recovered end of Rebuild processing

xxx : RLU number

End of rebuild to DV
(Bad Data)

Error

M 21810xxx RAID Group#0xxx recovered end of Rebuild processing

xxx : RLU number

Disconnected intra-cabinet path

Error

M 0732xxyy Remote Copy Path (MID#xx PORT#yy) Not Available

xx : MID
yy : Port

REC automatic HALT occurrence

Error

M 13CF11xx REC Automatic HALT or ERROR occurred.(xx)

xx : 00 is path error, 01 heavy load, 02 ERROR

Copy session
[Active -> Error]

Error

M 13CE0001 Error session was detected. (Local:xxxxx Remote:xxxxx)

xxxxx : Number of copy sessions that status is Error

Copy session
[Suspend -> Error]

Error

M 13CE0002 Foreseen error session was detected. (Local:xxxxx Remote:xxxxx)

xxxxx : Number of copy sessions that status changed from Suspend to Error

Copy session
[Active -> Halt]

Error

M 13CE0003 Halt session was detected. (Remote:xxxxx)

xxxxx : Number of copy sessions that status is Halt

Copy session
[Error -> Idle]

Error

M 13CE0004 Error session was cleared.

Copy session
[Suspend -> Error -> Idle]

Error

M 13CE0005 Foreseen error session was cleared.

Copy session
[Halt -> Active]

Error

M 13CE0006 Halt session was cleared.

Recovery Notification

Target

Level

Event Display

Remarks

CM BE Expander Warning recovery

Information

R 06SSMM00 Controller Module#n(zz xxHz) BE Expander Normal <pp ss rr>

SS : Parts subtype
MM
: CM MID (10 - 11)
n : Port number (0 - 1)
zz : Model (FC/SAS/iSCSI)
xx : Frequency (800MHz/1.2GHz)
pp : Parts number
ss : Serial number
rr : Revision

EXP Warning recovery

Information

R 9000DDnn Expander DE#DD/EXP#n Normal <pp ss rr>

DD : DE ID
nn : Port number (00 - 01)
n : Port number (0 - 1)
pp : Parts number
ss : Serial number
rr : Revision

PSU Alarm recovery (AC-Fail clear)

Information

R D200DD0N Power Supply Unit DE#DD /PSU#N Normal <pp ss rr>

DD : DE ID
N : Side 0, side 1
pp : Parts number
ss : Serial number
rr : Revision

DE exhaust temperature alarm recovery

Information

R DA0tDD00 DE OUT TEMP Normal

DD : DE ID
t : Type(1: 3.5"DE / 2: 2.5"DE)

DE intake air temperature alarm recovery

Information

R DB0tDD00 DE IN TEMP Normal

DD : DE ID
t : Type(1: 3.5"DE / 2: 2.5"DE)