Top
ETERNUS SF Express V16.3 / Storage Cruiser V16.3 Event Guide
FUJITSU Storage

4.3 ETERNUS DX S2 series (DX60 S2 excluded)

Event traps are messages reported from a device. If you have any questions about the message contents, refer to the relevant hardware manual to take corrective actions.

Notification of Component Blockage

Target

Level

Event Display

Remarks

CM Unit

Error

P 01SSMM00 Controller Module#m(zz) Fault <pp ss rr>

SS : Parts subtype
MM : Module ID
m : CM number
zz : Model
pp : Parts number
ss : Serial number
rr : Revision

CM DMA Port

Error

P 02SSMM0p Controller Module#m(zz) DMA PORT#p Fault <pp ss rr>

SS : Parts subtype
MM : Module ID
p : Port number
zz : Model
pp : Parts number
ss : Serial number
rr : Revision

CM BIOS

Error

P 03SSMM0v Controller Module#m(zz) BIOS#v Fault <pp ss rr>

SS : Parts subtype
MM : Module ID
v : Device number
zz : Model
pp : Parts number
ss : Serial number
rr : Revision

CM RTC

Error

P 04SSMM00 Controller Module#m(zz) RTC Fault <pp ss rr>

SS : Parts subtype
MM : Module ID
zz : Model
pp : Parts number
ss : Serial number
rr : Revision

CM NVRAM

Error

P 05SSMM00 Controller Module#m(zz) NVRAM Fault <pp ss rr>

SS : Parts subtype
MM : Module ID
zz : Model
pp : Parts number
ss : Serial number
rr : Revision

CM MMC

Error

P 0600MM00 Controller Module#m(zz) MMC Fault <pp ss rr>

MM : Module ID
m : CM number
zz : Model
pp : Parts number
ss : Serial number
rr : Revision

CM Expander

Error

P 06SSMM0v Controller Module#m(zz) EXP#v Fault <pp ss rr>

SS : Parts subtype
MM : Module ID
v : Device number
m : CM number
zz : Model
pp : Parts number
ss : Serial number
rr : Revision

CM DI PORT

Error

P 08SSMMvp Controller Module#m(zz) DI Port#p Fault <pp ss rr>

SS : Parts subtype
MM : Module ID
v : Device number
p : Port number
m : CM number
zz : Model
pp : Parts number
ss : Serial number
rr : Revision

CM Expander In Port

Error

P 09SSMMvp Controller Module#m(zz) EXP#v In Port#p Fault <pp ss rr>

SS : Parts subtype
MM : Module ID
v : Device number
p : Port number
m : CM number
zz : Model
pp : Parts number
ss : Serial number
rr : Revision

CM Expander Out Port

Error

P 0ASSMMvp Controller Module#m(zz) EXP#v Out Port#p Fault <pp ss rr>

SS : Parts subtype
MM : Module ID
v : Device number
p : Port number
m : CM number
zz : Model
pp : Parts number
ss : Serial number
rr : Revision

CM Memory

Error

P 0BSSMMnn Controller Module#m(zz) Cache(MEM #xGB) Slot#nn Fault <pp ss rr>

SS : Parts subtype
MM : Module ID
nn : Slot number
m : CM number
zz : Model
x : Capacity
pp : Parts number
ss : Serial number
rr : Revision

CM BUD

Error

P 0CSSMM00 Controller Module#m(zz) BUD(#xxGB) Fault <pp ss rr>

SS : Parts subtype
MM : Module ID
m : CM number
zz : Model
xx : Capacity
pp : Parts number
ss : Serial number
rr : Revision

CM FAN

Error

P 0DSSMM00 Controller Module#m(zz) FAN Fault <pp ss rr>

SS : Parts subtype
MM : Module ID
m : CM number
zz : Model
pp : Parts number
ss : Serial number
rr : Revision

CM NAND Controller

Error

P 0ESSMM00 Controller Module#m(zz) NAND Controller Fault <pp ss rr>

SS : Parts subtype
MM : Module ID
m : CM number
zz : Model
pp : Parts number
ss : Serial number
rr : Revision

CM SCU

Error

P 0FSSMM00 Controller Module#m(zz) SCU Fault <pp ss rr>

SS : Parts subtype
MM : Module ID
m : CM number
zz : Model
pp : Parts number
ss : Serial number
rr : Revision

CA

Error

P 10SSMM00 CA Slot#n-v(zz) (on CM#m) Fault <pp ss rr>

SS : Parts subtype
MM : Module ID
n : Slot number
v : Device number
zz : Model
m : CM number
pp : Parts number
ss : Serial number
rr : Revision

CA Port

Error

P 11SSMM0p CA Slot#n-v(zz) (on CM#m) Port#p Fault <pp ss rr>

SS : Parts subtype
MM : Module ID
p : Port number
n : Slot number
v : Device number
zz : Model
m : CM number
pp : Parts number
ss : Serial number
rr : Revision

SFP for FC-CA

Error

P 1ASSMM0p FC SFP CA Slot#n-v(zz) (on CM#m) Port#p Fault <pp ss rr oo>

SS : Parts subtype
MM : Module ID
p : Port number
n : Slot number
v : Device number
zz : Model
m : CM number
pp : Parts number
ss : Serial number
rr : Revision
oo : Other Information

SFP for FCLink-CA

Error

P 1BSSMM0p FCLink SFP CA Slot#n-v(zz) (on CM#m) Port#p Fault <pp ss rr oo>

SS : Parts subtype
MM : Module ID
p : Port number
n : Slot number
v : Device number
zz : Model
m : CM number
pp : Parts number
ss : Serial number
rr : Revision
oo : Other Information

SFP+ for FC-CA

Error

P 1CSSMM0p FC SFP+ CA Slot#n-v(zz) (on CM#m) Port#p Fault <pp ss rr oo>

SS : Parts subtype
MM : Module ID
p : Port number
n : Slot number
v : Device number
zz : Model
m : CM number
pp : Parts number
ss : Serial number
rr : Revision
oo : Other Information

SFP+ for 10G-iSCSI-CA

SFP+ for FCoE-CA

Error

P 1DSSMM0p iSCSI FCoE SFP+ CA Slot#n-v(zz) (on CM#m) Port#p Fault <pp ss rr oo>

SS : Parts subtype
MM : Module ID
p : Port number
n : Slot number
v : Device number
zz : Model
m : CM number
pp : Parts number
ss : Serial number
rr : Revision
oo : Other Information

SFP+ Copper for 10G-iSCSI-CA

SFP+ for FCoE-CA

Error

P 1E00MM0p iSCSI FCoE SFP+Cp CA Slot#S(zz) (on CM#m) Port#p Fault <pp ss rr oo>

MM : Module ID
p : Port number
m : CM number
zz : Model
pp : Parts number
ss : Serial number
rr : Revision
oo : Other Information

SFP+ Longwave for FC-CA

Error

P 1900MM0p FC SFP+ Longwave CA Slot#S(zz) (on CM#m) Port#p Fault <pp ss rr oo>

MM : Module ID
p : Port number
m : CM number
zz : Model
pp : Parts number
ss : Serial number
rr : Revision
oo : Other Information

SFP Type Unknown

Error

P 1FSSMM0p SFP(Type Unknown) CA Slot#n-v(zz) (on CM#m) Port#p Fault <pp ss rr oo>

SS : Parts subtype
MM : Module ID
p : Port number
n : Slot number
v : Device number
zz : Model
m : CM number
pp : Parts number
ss : Serial number
rr : Revision
oo : Other Information

CM FPGA

Error

P 21SSMM00 Controller Module#m(zz) FPGA Fault <pp ss rr>

SS : Parts subtype
MM : Module ID
m : CM number
zz : Model
pp : Parts number
ss : Serial number
rr : Revision

CM LAN Port

Error

P 22SSMM0p Controller Module#m(zz) LAN PORT#p Fault <pp ss rr>

SS : Parts subtype
MM : Module ID
p : Port number
m : CM number
zz : Model
pp : Parts number
ss : Serial number
rr : Revision

CM PCH

Error

P 2300MM00 Controller Module#m(zz) PCH Fault <pp ss rr>

MM : Module ID
m : CM number
zz : Model
pp : Parts number
ss : Serial number
rr : Revision

CM QSFP

Error

P 2ASSMMvp Controller Module#m(zz) QSFP#v#p Fault <pp ss rr>

SS : Parts subtype
MM : Module ID
v : Device number
p : Port number
m : CM number
zz : Model
pp : Parts number
ss : Serial number
rr : Revision

FRT

Error

P 4000MM00 FRT#n Fault <pp ss rr>

MM : Module ID
n : FRT number
pp : Parts number
ss : Serial number
rr : Revision

BRT

Error

P 5000MM00 BRT#n Fault <pp ss rr>

MM : Module ID
n : BRT number
pp : Parts number
ss : Serial number
rr : Revision

BRT Out Port

Error

P 5100MM0P BRT#n Out Port#P Fault <pp ss rr>

MM : Module ID
n : BRT number
p : Port number
pp : Parts number
ss : Serial number
rr : Revision

BRT In Port

Error

P 5200MMvP BRT#n InPort#P Fault <pp ss rr>

MM : Module ID
v : EXP number
p : Port number
n : BRT number
pp : Parts number
ss : Serial number
rr : Revision

BRT EXP

Error

P 5300MM0v BRT#n EXP#v Fault <pp ss rr>

MM : Module ID
v : EXP number
n : BRT number
pp : Parts number
ss : Serial number
rr : Revision

BRT QSFP

Error

P 5A00MM0P BRT#n QSFP#P Fault <pp ss rr>

MM : Module ID
n : BRT number
P : Port number
pp : Parts number
ss : Serial number
rr : Revision

SVC

Error

P 6000MM00 SVC#n Fault <pp ss rr>

MM : Module ID
n : SVC number
pp : Parts number
ss : Serial number
rr : Revision

SVC LAN Port

Error

P 6100MM0P SVC#n LAN PORT#P Fault <pp ss rr>

MM : Module ID
P : Port number
n : SVC number
pp : Parts number
ss : Serial number
rr : Revision

SVC PCIe SW

Error

P 6200MM00 SVC#n PCIe SW Fault <pp ss rr>

MM : Module ID
n : SVC number
pp : Parts number
ss : Serial number
rr : Revision

SVC RCI board

Error

P 6300MM00 SVC#n RCI board Fault <pp ss rr>

MM : Module ID
n : SVC number
pp : Parts number
ss : Serial number
rr : Revision

CE FAN UNIT

Error

P 71000n00 CE FAN UNIT#n Fault <pp ss rr>

n : Slot number
pp : Parts number
ss : Serial number
rr : Revision

PANEL UNIT

Error

P 72000000 PANEL UNIT Fault <pp ss rr>

pp : Parts number
ss : Serial number
rr : Revision

CPSU

Error

P 73000n00 Power Supply Unit/CPSU#n Fault <pp ss rr>

n : Slot number
pp : Parts number
ss : Serial number
rr : Revision

SCCB

Error

P 74000n00 SCCB#n Fault <pp ss rr>

n : Slot number
pp : Parts number
ss : Serial number
rr : Revision

BBU

Error

P 75000n00 BBU#n Fault <pp ss rr>

n : Slot number
pp : Parts number
ss : Serial number
rr : Revision

BCU

Error

P 75000n00 BCU#n Fault <pp ss rr>

n : Slot number
pp : Parts number
ss : Serial number
rr : Revision

BTU

Error

P 76000n00 BTU#n Fault <pp ss rr>

n : Slot number
pp : Parts number
ss : Serial number
rr : Revision

3.5 Inch DISK

Error

P 80SSUU0N HDD 3.5 DE#UU-Disk#n(SAS xxxGB yykrpm cc) Fault <pp ss rr tt uu>

SS : Parts subtype
UU : DE ID
N : Slot number (hexadecimal notation)
n : Slot number (decimal notation)
xxx : Disk capacity
yy : Disk rotation
cc : Disk information
pp : Parts number
ss : Serial number
rr : Revision
tt : Date Code
uu : Config Code

3.5 Inch Disk
(Failed Usable)

Error

P 80SSUU0N HDD 3.5 DE#UU-Disk#n(SAS xxxGB yykrpm cc) Failed Usable <pp ss rr tt uu>

SS : Parts subtype
UU : DE ID
N : Slot number (hexadecimal notation)
n : Slot number (decimal notation)
xxx : Disk capacity
yy : Disk rotation
cc : Disk information
pp : Parts number
ss : Serial number
rr : Revision
tt : Date Code
uu : Config Code

3.5 Inch Disk
(Disk abnormal performance)

Error

P 80SSUU0N HDD 3.5 DE#UU-Disk#n(SAS xxxGB yykrpm cc) Slow Down <pp ss rr tt uu>

SS : Parts subtype
UU : DE ID
N : Slot number (hexadecimal notation)
n : Slot number (decimal notation)
xxx : Disk capacity
yy : Disk rotation
cc : Disk information
pp : Parts number
ss : Serial number
rr : Revision
tt : Date Code
uu : Config Code

2.5 Inch DISK

Error

P 81SSUUNN HDD 2.5 DE#UU-Disk#n(SAS xxxGB yykrpm cc) Fault <pp ss rr tt uu>

SS : Parts subtype
UU : DE ID
N : Slot number (hexadecimal notation)
n : Slot number (decimal notation)
xxx : Disk capacity
yy : Disk rotation
cc : Disk information
pp : Parts number
ss : Serial number
rr : Revision
tt : Date Code
uu : Config Code

2.5 Inch Disk
(Failed Usable)

Error

P 81SSUUNN HDD 2.5 DE#UU-Disk#n(SAS xxxGB yykrpm cc) Failed Usable <pp ss rr tt uu>

SS : Parts subtype
UU : DE ID
N : Slot number (hexadecimal notation)
n : Slot number (decimal notation)
xxx : Disk capacity
yy : Disk rotation
cc : Disk information
pp : Parts number
ss : Serial number
rr : Revision
tt : Date Code
uu : Config Code

2.5 Inch Disk
(Disk abnormal performance)

Error

P 81SSUUNN HDD 2.5 DE#UU-Disk#n(SAS xxxGB yykrpm cc) Slow Down <pp ss rr tt uu>

SS : Parts subtype
UU : DE ID
N : Slot number (hexadecimal notation)
n : Slot number (decimal notation)
xxx : Disk capacity
yy : Disk rotation
cc : Disk information
pp : Parts number
ss : Serial number
rr : Revision
tt : Date Code
uu : Config Code

3.5 Inch SSD

Error

P 84SSUU0N SSD 3.5 DE#UU-Slot#n(SAS xxxGB yykrpm cc) Fault <pp ss rr tt uu>

SS : Parts subtype
UU : DE ID
N : Slot number (hexadecimal notation)
n : Slot number (decimal notation)
xxx : Disk capacity
yy : Disk rotation
cc : Disk information
pp : Parts number
ss : Serial number
rr : Revision
tt : Date Code
uu : Config Code

3.5 Inch SSD
(Failed Usable)

Error

P 84SSUU0N SSD 3.5 DE#UU-Slot#n(SAS xxxGB yykrpm cc) Failed Usable <pp ss rr tt uu>

SS : Parts subtype
UU : DE ID
N : Slot number (hexadecimal notation)
n : Slot number (decimal notation)
xxx : Disk capacity
yy : Disk rotation
cc : Disk information
pp : Parts number
ss : Serial number
rr : Revision
tt : Date Code
uu : Config Code

2.5 Inch SSD

Error

P 85SSUUNN SSD 2.5 DE#UU-Slot#n(SAS xxxGB yykrpm cc) Fault <pp ss rr tt uu>

SS : Parts subtype
UU : DE ID
N : Slot number (hexadecimal notation)
n : Slot number (decimal notation)
xxx : Disk capacity
yy : Disk rotation
cc : Disk information
pp : Parts number
ss : Serial number
rr : Revision
tt : Date Code
uu : Config Code

2.5 Inch SSD
(Failed Usable)

Error

P 85SSUUNN SSD 2.5 DE#UU-Slot#n(SAS xxxGB yykrpm cc) Failed Usable <pp ss rr tt uu>

SS : Parts subtype
UU : DE ID
N : Slot number (hexadecimal notation)
n : Slot number (decimal notation)
xxx : Disk capacity
yy : Disk rotation
cc : Disk information
pp : Parts number
ss : Serial number
rr : Revision
tt : Date Code
uu : Config Code

3.5 Inch DISK
(Compare Error)

Error

P 88SSUU0N HDD 3.5 DE#UU-Disk#n(SAS xxxGB yykrpm cc) Fault <pp ss rr tt uu>

SS : Parts subtype
UU : DE ID
N : Slot number (hexadecimal notation)
n : Slot number (decimal notation)
xxx : Disk capacity
yy : Disk rotation
cc : Disk information
pp : Parts number
ss : Serial number
rr : Revision
tt : Date Code
uu : Config Code

2.5 Inch DISK
(Compare Error)

Error

P 88SSUUNN HDD 2.5 DE#UU-Disk#n(SAS xxxGB yykrpm cc) Fault <pp ss rr tt uu>

SS : Parts subtype
UU : DE ID
N : Slot number (hexadecimal notation)
n : Slot number (decimal notation)
xxx : Disk capacity
yy : Disk rotation
cc : Disk information
pp : Parts number
ss : Serial number
rr : Revision
tt : Date Code
uu : Config Code

3.5 Inch SSD
(Compare Error)

Error

P 88SSUU0N SSD 3.5 DE#UU-Slot#n(SAS xxxGB yykrpm cc) Fault <pp ss rr tt uu>

SS : Parts subtype
UU : DE ID
N : Slot number (hexadecimal notation)
n : Slot number (decimal notation)
xxx : Disk capacity
yy : Disk rotation
cc : Disk information
pp : Parts number
ss : Serial number
rr : Revision
tt : Date Code
uu : Config Code

2.5 Inch SSD
(Compare Error)

Error

P 88SSUUNN SSD 2.5 DE#UU-Slot#n(SAS xxxGB yykrpm cc) Fault <pp ss rr tt uu>

SS : Parts subtype
UU : DE ID
N : Slot number (hexadecimal notation)
n : Slot number (decimal notation)
xxx : Disk capacity
yy : Disk rotation
cc : Disk information
pp : Parts number
ss : Serial number
rr : Revision
tt : Date Code
uu : Config Code

IOM6

Error

P 90SSUU0n IOM6 DE#UU/IOM#n Fault <pp ss rr>

SS : Parts subtype
UU : DE ID
n : EXP number
pp : Parts number
ss : Serial number
rr : Revision

IOM6 Port

Error

P 91SSUUnp IOM6 Port DE#UU/IOM#n/Port#p Fault <pp ss rr>

SS : Parts subtype
UU : DE ID
n : EXP number
p : Port number
pp : Parts number
ss : Serial number
rr : Revision

IOM6 QSFP

Error

P 9ASSUUnp IOM6 QSFP DE#UU/IOM#n/Port#p Fault <pp ss rr>

SS : Parts subtype
UU : DE ID
n : EXP number
p : Port number
pp : Parts number
ss : Serial number
rr : Revision

PSU

Error

P D2SSUU0n Power Supply Unit DE#UU/PSU#n Fault <pp ss rr>

SS : Parts subtype
UU : DE ID
n : Slot number
pp : Parts number
ss : Serial number
rr : Revision

Warning (Temperature Alarm)

Target

Level

Event Display

Remarks

CE Abnormal exhaust gas temperature
(FATAL)

Error

P 7A000000 CE Exhaust temperature Fatal

CE Abnormal exhaust gas temperature
(Sensor failure)

Error

P 7A000000 CE Exhaust temperature sensor Fault

CE Abnormal exhaust gas temperature
(WARNING)

Warning

J 7A000000 CE Exhaust temperature Warning

CE Abnormal intake temperature
(Sensor failure)

Error

P 7B000000 CE Intake temperature sensor Fault

CE Abnormal intake temperature
(WARNING)

Warning

J 7B000000 CE Intake temperature Warning

DE Abnormal exhaust gas temperature
(FATAL)

Error

P DASSUU00 DE Exhaust temperature DE#UU Fatal

SS : Parts subtype
UU : DE ID

DE Abnormal exhaust gas temperature
(Sensor failure)

Error

P DASSUU00 DE Exhaust temperature sensor DE#UU Fault

SS : Parts subtype
UU : DE ID

DE Abnormal exhaust gas temperature
(WARNING)

Warning

J DASSUU00 DE Exhaust temperature DE#UU Warning

SS : Parts subtype
UU : DE ID

DE Abnormal intake temperature
(Sensor failure)

Error

P DBSSUU00 DE Intake temperature sensor DE#UU Fault

SS : Parts subtype
UU : DE ID

DE Abnormal intake temperature
(WARNING)

Warning

J DBSSUU00 DE Intake temperature DE#UU Warning

SS : Parts subtype
UU : DE ID

Warning (Expiration)

Target

Level

Event Display

Remarks

Six months before battery life expiration

Warning

J 70060n00 BATTERY#b 6MONTH WARNING YYYY/MM

n : Slot number
b : BTU number
YYYY/MM : Term of validity (year/month)

One week before battery life expiration

Warning

J 70070n00 BATTERY#b 1WEEK WARNING WARNING YYYY/MM

n : Slot number
b : BTU number
YYYY/MM : Term of validity (year/month)

N days before battery life expiration

Warning

J 70070n00 BATTERY#b NDAY WARNING WARNING YYYY/MM

n : Slot number
b : BTU number
N : Days
YYYY/MM : Term of validity (year/month)

Battery life expiration

Error

J 70FE0n00 BATTERY#b EXPIRATION ALARM YYYY/MM

n : Slot number
b : BTU number
YYYY/MM : Term of validity (year/month)

Warning (Other)

Target

Level

Event Display

Remarks

CM Warning

Warning

J 01SSMM00 Controller Module#m(zz) Warning factor(ww) <pp ss rr>

SS : Parts subtype
MM : Module ID
m : CM number
zz : Model
ww : Factor Code
pp : Parts number
ss : Serial number
rr : Revision

CM DMA Port Warning

Warning

J 02SSMM0p Controller Module#m(zz) DMA PORT#p Warning <pp ss rr>

SS : Parts subtype
MM : Module ID
p : Port number
m : CM number
zz : Model
pp : Parts number
ss : Serial number
rr : Revision

CM BIOS Warning

Warning

J 03SSMM0v Controller Module#m(zz) BIOS#v Warning <pp ss rr>

SS : Parts subtype
MM : Module ID
v : Device number
m : CM number
zz : Model
pp : Parts number
ss : Serial number
rr : Revision

CM RTC Warning

Warning

J 04SSMM00 Controller Module#m(zz) RTC Warning <pp ss rr>

SS : Parts subtype
MM : Module ID
m : CM number
zz : Model
pp : Parts number
ss : Serial number
rr : Revision

CM NVRAM Warning

Warning

J 05SSMM00 Controller Module#m(zz) NVRAM Warning <pp ss rr>

SS : Parts subtype
MM : Module ID
m : CM number
zz : Model
pp : Parts number
ss : Serial number
rr : Revision

CM MMC Warning

Warning

J 0600MM00 Controller Module#m(zz) MMC Warning <pp ss rr>

MM : Module ID
m : CM number
zz : Model
pp : Parts number
ss : Serial number
rr : Revision

CM Expander Warning

Warning

J 06SSMM0v Controller Module#m(zz) EXP#v Warning <pp ss rr>

SS : Parts subtype
MM : Module ID
v : Device number
m : CM number
zz : Model
pp : Parts number
ss : Serial number
rr : Revision

CM DI PORT Warning

Warning

J 08SSMMvp Controller Module#m(zz) DI Port#p Warning <pp ss rr>

SS : Parts subtype
MM : Module ID
v : Device number
p : Port number
m : CM number
zz : Model
pp : Parts number
ss : Serial number
rr : Revision

CM Expander In Port Warning

Warning

J 09SSMMvp Controller Module#m(zz) EXP#v In Port#p Warning <pp ss rr>

SS : Parts subtype
MM : Module ID
v : Device number
p : Port number
m : CM number
zz : Model
pp : Parts number
ss : Serial number
rr : Revision

CM Expander Out Port Warning

Warning

J 0ASSMMvp Controller Module#m(zz) EXP#v Out Port#p Warning <pp ss rr>

SS : Parts subtype
MM : Module ID
v : Device number
p : Port number
m : CM number
zz : Model
pp : Parts number
ss : Serial number
rr : Revision

CM BUD Warning

Warning

J 0CSSMM00 Controller Module#m(zz) BUD(#xxGB) Warning <pp ss rr>

SS : Parts subtype
MM : Module ID
m : CM number
zz : Model
xx : Capacity
pp : Parts number
ss : Serial number
rr : Revision

CM FAN Warning

Warning

J 0DSSMM00 Controller Module#m(zz) FAN Warning <pp ss rr>

SS : Parts subtype
MM : Module ID
m : CM number
zz : Model
pp : Parts number
ss : Serial number
rr : Revision

CM NAND Controller Warning

Warning

J 0ESSMM00 Controller Module#m(zz) NAND Controller Warning <pp ss rr>

SS : Parts subtype
MM : Module ID
m : CM number
zz : Model
pp : Parts number
ss : Serial number
rr : Revision

CM SCU Warning

Warning

J 0FSSMM00 Controller Module#m(zz) SCU Warning <pp ss rr>

SS : Parts subtype
MM : Module ID
m : CM number
zz : Model
pp : Parts number
ss : Serial number
rr : Revision

CA Warning

Warning

J 10SSMM00 CA Slot#n-v(zz) (on CM#m) Warning <pp ss rr>

SS : Parts subtype
MM : Module ID
n : Slot number
v : Device number
zz : Model
m : CM number
pp : Parts number
ss : Serial number
rr : Revision

CA Port Warning

Warning

J 11SSMM0p CA Slot#n-v(zz) (on CM#m) Port#p Warning <pp ss rr>

SS : Parts subtype
MM : Module ID
p : Port number
n : Slot number
v : Device number
zz : Model
m : CM number
pp : Parts number
ss : Serial number
rr : Revision

CM FPGA Warning

Warning

J 21SSMM00 Controller Module#m(zz) FPGA Warning <pp ss rr>

SS : Parts subtype
MM : Module ID
m : CM number
zz : Model
pp : Parts number
ss : Serial number
rr : Revision

CM LAN Port Warning

Warning

J 22SSMM0p Controller Module#m(zz) LAN PORT#p Warning <pp ss rr>

SS : Parts subtype
MM : Module ID
p : Port number
m : CM number
zz : Model
pp : Parts number
ss : Serial number
rr : Revision

CM PCH Warning

Warning

J 2300MM00 Controller Module#m(zz) PCH Warning <pp ss rr>

MM : Module ID
m : CM number
zz : Model
pp : Parts number
ss : Serial number
rr : Revision

FRT Warning

Warning

J 4000MM00 FRT#n Warning <pp ss rr>

MM : Module ID
n : FRT number
pp : Parts number
ss : Serial number
rr : Revision

BRT Warning

Warning

J 5000MM00 BRT#n Warning <pp ss rr>

MM : Module ID
n : BRT number
pp : Parts number
ss : Serial number
rr : Revision

BRT Out Port Warning

Warning

J 5100MM0P BRT#n Out Port#P Warning <pp ss rr>

MM : Module ID
n : BRT number
P : Port number
pp : Parts number
ss : Serial number
rr : Revision

BRT In Port Warning

Warning

J 5200MMvP BRT#n In Port#P Warning <pp ss rr>

MM : Module ID
v : EXP number
n : BRT number
P : Port number
pp : Parts number
ss : Serial number
rr : Revision

BRT EXP Warning

Warning

J 5300MM0v BRT#n EXP#v Warning <pp ss rr>

MM : Module ID
v : EXP number
n : BRT number
pp : Parts number
ss : Serial number
rr : Revision

BRT QSFP Warning

Warning

J 5A00MM0P BRT#n QSFP#P Warning <pp ss rr>

MM : Module ID
n : BRT number
P : Port number
pp : Parts number
ss : Serial number
rr : Revision

SVC Warning

Warning

J 6000MM00 SVC#n Warning <pp ss rr>

MM : Module ID
n : SVC number
pp : Parts number
ss : Serial number
rr : Revision

CE FAN UNIT

Warning

J 71000n00 CE FAN UNIT#n Warning <pp ss rr>

n : Slot number
pp : Parts number
ss : Serial number
rr : Revision

PANEL UNIT

Warning

J 72000000 PANEL UNIT Warning <pp ss rr>

pp : Parts number
ss : Serial number
rr : Revision

CPSU Warning

Warning

J 73000n00 Power Supply Unit/CPSU#n Warning <pp ss rr>

n : Slot number
pp : Parts number
ss : Serial number
rr : Revision

BBU Warning

Warning

J 75000n00 BBU#n Warning <pp ss rr>

n : Slot number
pp : Parts number
ss : Serial number
rr : Revision

BCU Warning

Warning

J 75000n00 BCU#n Warning <pp ss rr>

n : Slot number
pp : Parts number
ss : Serial number
rr : Revision

BTU Warning

Warning

J 76000n00 BTU#n Warning <pp ss rr>

n : Slot number
pp : Parts number
ss : Serial number
rr : Revision

SMART notice from Disk
(3.5inch)

Warning

J 80SSUU0N HDD 3.5 DE#UU-Disk#n(SAS xxxGB yykrpm cc) SMART <pp ss rr tt uu>

SS : Parts subtype
UU : DE ID
N : Slot number (hexadecimal notation)
n : Slot number (decimal notation)
xxx : Disk capacity
yy : Disk rotation
cc : Disk information
pp : Parts number
ss : Serial number
rr : Revision
tt : Date Code
uu : Config Code

Disk preventative separation SMART
(3.5inch)

Warning

J 80SSUU0N HDD 3.5 DE#UU-Disk#n(SAS xxxGB yykrpm cc) Warning <pp ss rr tt uu>

SS : Parts subtype
UU : DE ID
N : Slot number (hexadecimal notation)
n : Slot number (decimal notation)
xxx : Disk capacity
yy : Disk rotation
cc : Disk information
pp : Parts number
ss : Serial number
rr : Revision
tt : Date Code
uu : Config Code

Disk abnormal performance SMART
(3.5inch)

Warning

J 80SSUU0N HDD 3.5 DE#UU-Disk#n(SAS xxxGB yykrpm cc) WarnSlow <pp ss rr tt uu>

SS : Parts subtype
UU : DE ID
N : Slot number (hexadecimal notation)
n : Slot number (decimal notation)
xxx : Disk capacity
yy : Disk rotation
cc : Disk information
pp : Parts number
ss : Serial number
rr : Revision
tt : Date Code
uu : Config Code

Disk abnormal performance notice
(3.5inch)

Warning

J 80SSUU0N HDD 3.5 DE#UU-Disk#n(SAS xxxGB yykrpm cc) SlowDown <pp ss rr tt uu>

SS : Parts subtype
UU : DE ID
N : Slot number (hexadecimal notation)
n : Slot number (decimal notation)
xxx : Disk capacity
yy : Disk rotation
cc : Disk information
pp : Parts number
ss : Serial number
rr : Revision
tt : Date Code
uu : Config Code

SMART notice from Disk
(2.5inch)

Warning

J 81SSUUNN HDD 2.5 DE#UU-Disk#n(SAS xxxGB yykrpm cc) SMART <pp ss rr tt uu>

SS : Parts subtype
UU : DE ID
N : Slot number (hexadecimal notation)
n : Slot number (decimal notation)
xxx : Disk capacity
yy : Disk rotation
cc : Disk information
pp : Parts number
ss : Serial number
rr : Revision
tt : Date Code
uu : Config Code

Disk preventative separation SMART
(2.5inch)

Warning

J 81SSUUNN HDD 2.5 DE#UU-Disk#n(SAS xxxGB yykrpm cc) Warning <pp ss rr tt uu>

SS : Parts subtype
UU : DE ID
N : Slot number (hexadecimal notation)
n : Slot number (decimal notation)
xxx : Disk capacity
yy : Disk rotation
cc : Disk information
pp : Parts number
ss : Serial number
rr : Revision
tt : Date Code
uu : Config Code

Disk abnormal performance SMART
(2.5inch)

Warning

J 81SSUUNN HDD 2.5 DE#UU-Disk#n(SAS xxxGB yykrpm cc) WarnSlow <pp ss rr tt uu>

SS : Parts subtype
UU : DE ID
N : Slot number (hexadecimal notation)
n : Slot number (decimal notation)
xxx : Disk capacity
yy : Disk rotation
cc : Disk information
pp : Parts number
ss : Serial number
rr : Revision
tt : Date Code
uu : Config Code

Disk abnormal performance notice
(2.5inch)

Warning

J 81SSUUNN HDD 2.5 DE#UU-Disk#n(SAS xxxGB yykrpm cc) SlowDown <pp ss rr tt uu>

SS : Parts subtype
UU : DE ID
N : Slot number (hexadecimal notation)
n : Slot number (decimal notation)
xxx : Disk capacity
yy : Disk rotation
cc : Disk information
pp : Parts number
ss : Serial number
rr : Revision
tt : Date Code
uu : Config Code

SMART notice from SSD
(3.5inch)

Warning

J 84SSUU0N SSD 3.5 DE#UU-Slot#n(SAS xxxGB yykrpm cc) SMART <pp ss rr tt uu>

SS : Parts subtype
UU : DE ID
N : Slot number (hexadecimal notation)
n : Slot number (decimal notation)
xxx : Disk capacity
yy : Disk rotation
cc : Disk information
pp : Parts number
ss : Serial number
rr : Revision
tt : Date Code
uu : Config Code

SSD preventative separation SMART
(3.5inch)

Warning

J 84SSUU0N SSD 3.5 DE#UU-Slot#n(SAS xxxGB yykrpm cc) Warning <pp ss rr tt uu>

SS : Parts subtype
UU : DE ID
N : Slot number (hexadecimal notation)
n : Slot number (decimal notation)
xxx : Disk capacity
yy : Disk rotation
cc : Disk information
pp : Parts number
ss : Serial number
rr : Revision
tt : Date Code
uu : Config Code

SMART notice from SSD
(2.5inch)

Warning

J 85SSUUNN SSD 2.5 DE#UU-Slot#n(SAS xxxGB yykrpm cc) SMART <pp ss rr tt uu>

SS : Parts subtype
UU : DE ID
N : Slot number (hexadecimal notation)
n : Slot number (decimal notation)
xxx : Disk capacity
yy : Disk rotation
cc : Disk information
pp : Parts number
ss : Serial number
rr : Revision
tt : Date Code
uu : Config Code

SSD preventative separation SMART
(2.5inch)

Warning

J 85SSUUNN SSD 2.5 DE#UU-Slot#n(SAS xxxGB yykrpm cc) Warning <pp ss rr tt uu>

SS : Parts subtype
UU : DE ID
N : Slot number (hexadecimal notation)
n : Slot number (decimal notation)
xxx : Disk capacity
yy : Disk rotation
cc : Disk information
pp : Parts number
ss : Serial number
rr : Revision
tt : Date Code
uu : Config Code

IOM6 Warning

Warning

J 90SSUU0n IOM6 DE#UU/IOM#n Warning <pp ss rr>

SS : Parts subtype
UU : DE ID
n : EXP number
pp : Parts number
ss : Serial number
rr : Revision

IOM6 Port Warning

Warning

J 91SSUUnp IOM6 Port DE#UU/IOM#n/Port#p Warning <pp ss rr>

SS : Parts subtype
UU : DE ID
n : EXP number
p : Port number
pp : Parts number
ss : Serial number
rr : Revision

IOM6 QSFP Warning

Warning

J 9ASSUUnp IOM6 QSFP DE#UU/IOM#n/Port#p Warning <pp ss rr>

SS : Parts subtype
UU : DE ID
n : EXP number
p : Port number
pp : Parts number
ss : Serial number
rr : Revision

IOM6 Check1

Warning

J C190UUnp IOM6 DE#UU/IOM#n Reboot <pp ss rr>

UU : DE ID
n : EXP number
p : Port number
pp : Parts number
ss : Serial number
rr : Revision

CM Check1

Warning

J C1MM0000 Controller Module#m(zz) Reboot <pp ss rr>

MM : Module ID
m : CM number
zz : Model
pp : Parts number
ss : Serial number
rr : Revision

CA Check1

Warning

J C1MM0000 CA Slot#n-v(zz) (on CM#m) Reboot <pp ss rr>

MM : Module ID
n : Slot number
v : Device number
zz : Model
m : CM number
pp : Parts number
ss : Serial number
rr : Revision

BRT Check1

Warning

J C1MM0000 BRT#n Reboot <pp ss rr>

MM : Module ID
n : BRT number
pp : Parts number
ss : Serial number
rr : Revision

Multiple memory collectable error

Warning

J C3SSMM00 Controller Module#m(zz) Cache(MEM #xGB) Slot#nn Correctable Error <pp ss rr>

SS : Parts subtype
MM : Module ID
m : CM number
zz : Model
x : Capacity
pp : Parts number
ss : Serial number
rr : Revision

PSU Warning

Warning

J D2SSUU0n Power Supply Unit DE#UU/PSU#n Warning <pp ss rr>

SS : Parts subtype
UU : DE ID
n : Slot number
pp : Parts number
ss : Serial number
rr : Revision

RAID Recovery Notification

Target

Level

Event Display

Remarks

Start failure of rebuild to HS
(non HS)

Error

M A0110xxx RAID Group#0xxx start failure of Rebuild processing

xxx : RAID group number

Start of rebuild to HS

Error

M A0410xxx RAID Group#0xxx start procedure of Rebuild processing

xxx : RAID group number

End of rebuild to HS

Error

M A0810xxx RAID Group#0xxx normal end of Rebuild processing

xxx : RAID group number

Abnormal end of rebuild to HS
(source disk problem)

Error

M A0A10xxx RAID Group#0xxx abnormal end of Rebuild processing because of source disk problem

xxx : RAID group number

Abnormal end of rebuild to HS

Error

M A0B10xxx RAID Group#0xxx abnormal end of Rebuild processing

xxx : RAID group number

Retry of rebuild to HS

Error

M A0C10xxx RAID Group#0xxx retry procedure of Rebuild processing

xxx : RAID group number

Start of rebuild to DV

Error

M A1410xxx RAID Group#0xxx start procedure of Rebuild processing

xxx : RAID group number

End of rebuild to DV

Error

M A1810xxx RAID Group#0xxx normal end of Rebuild processing

xxx : RAID group number

Abnormal end of rebuild to DV
(source disk problem)

Error

M A1A10xxx RAID Group#0xxx abnormal end of Rebuild processing because of source disk problem

xxx : RAID group number

Abnormal end of rebuild to DV

Error

M A1B10xxx RAID Group#0xxx abnormal end of Rebuild processing

xxx : RAID group number

Retry of rebuild to DV

Error

M A1C10xxx RAID Group#0xxx retry procedure of Rebuild processing

xxx : RAID group number

Start of Copyback

Error

M A3420xxx RAID Group#0xxx start procedure of Copyback processing

xxx : RAID group number

End of Copyback

Error

M A3820xxx RAID Group#0xxx normal end of Copyback processing

xxx : RAID group number

Abnormal end of Copyback
(source disk problem)

Error

M A3A20xxx RAID Group#0xxx abnormal end of Copyback processing because of source disk problem

xxx : RAID group number

Abnormal end of Copyback

Error

M A3B20xxx RAID Group#0xxx abnormal end of Copyback processing

xxx : RAID group number

Retry of Copyback

Error

M A3C20xxx RAID Group#0xxx retry procedure of Copyback processing

xxx : RAID group number

Start failure of Redundant Copy
(non HS)

Error

M A4130xxx RAID Group#0xxx start failure of Redundant Copy processing

xxx : RAID group number

Start of Redundant Copy

Error

M A4430xxx RAID Group#0xxx start procedure of Redundant Copy processing

xxx : RAID group number

End of Redundant Copy
(Disk)

Error

P 21830xxx Disk Drive DE#uu-Disk#nn(SAS xxGB yykrpm cc) Redundant Copy end <pp ss rr>

xxx : RAID group number
UU : DE ID
nn : Slot number
xx : Disk capacity
yy : Disk rotation
cc : Disk information
pp : Parts number
ss : Serial number
rr : Revision

End of Redundant Copy
(SSD 3.5inch)

Error

P 21830xxx SSD 3.5 DE#uu-Slot#nn(SAS xxGB cc) Redundant Copy end <pp ss rr>

xxx : RAID group number
UU : DE ID
nn : Slot number
xx : Disk capacity
cc : Disk information
pp : Parts number
ss : Serial number
rr : Revision

End of Redundant Copy
(SSD 2.5inch)

Error

P 21830xxx SSD 2.5 DE#uu-Slot#nn(SAS xxGB cc) Redundant Copy end <pp ss rr>

xxx : RAID group number
UU : DE ID
nn : Slot number
xx : Disk capacity
cc : Disk information
pp : Parts number
ss : Serial number
rr : Revision

Abnormal end of Redundant Copy
(source disk problem)

Error

M A4A30xxx RAID Group#0xxx abnormal end of Redundant Copy processing because of source disk problem

xxx : RAID group number

Abnormal end of Redundant Copy

Error

M A4B30xxx RAID Group#0xxx abnormal end of Redundant Copy processing

xxx : RAID group number

Retry of Redundant Copy

Error

M A4C30xxx RAID Group#0xxx retry procedure of Redundant Copy processing

xxx : RAID group number

Event Notification (M Messages)

Target

Level

Event Display

Remarks

Write Bad Data

Error

M E0050xxx WRITE BAD DATA

xxx : RLU number

PINNED Data (Occurred)

Error

M E10300MM PINNED DATA was created CM#m-CPU#v

MM : CM Module ID where PINNED occurred
m : CM number
v : CM CPU number

PINNED Data (Cleared)

Error

M E1FF00MM PINNED DATA was cleared CM#m-CPU#v

MM : CM Module ID where PINNED cleared
m : CM number
v : CM CPU number

NRDY (Factor 01)

Error

M E2070001 NOT READY(01:Configuration Error)

NRDY (Factor 02)

Error

M E2070002 NOT READY(02:CM F/W Version Error)

NRDY (Factor 04)

Error

M E2070004 NOT READY(04:Restore Fail)

NRDY (Factor 11)

Error

M E207000B NOT READY(11:Power Off/Fail Incomplete)

NRDY (Factor 12)

Error

M E207000C NOT READY(12:Backup Fail)

NRDY (Factor 13)

Error

M E207000D NOT READY(13:Multi CM Down)

NRDY (Factor 14)

Error

M E207000E NOT READY(14:Machine Down Recovery End)

NRDY (Factor 15)

Error

M E207000F NOT READY(15:Machine Down Recovery Failed)

NRDY (Factor 16)

Error

M E2070010 NOT READY(16:DE Build Error)

NRDY (Factor 17)

Error

M E2070011 NOT READY(17:CM Memory Shortage)

NRDY (Factor 19)

Error

M E2070013 NOT READY(19:FRT Fault)

NRDY (Factor 20)

Error

M E2070014 NOT READY(20:BRT Fault)

NRDY (Factor 21)

Error

M E2070015 NOT READY(21:Auto CFD)

NRDY (Factor 22)

Error

M E2070016 NOT READY(22:No Version)

NRDY (Factor 23)

Error

M E2070017 NOT READY(23:AC Input Shortage)

NRDY (Factor 24)

Error

M E2070018 NOT READY(24:Configuration Data restored from System Disk)

NRDY (Factor 25)

Error

M E2070019 NOT READY(25:BUD Capacity Shortage)

NRDY (Factor 26)

Error

M E207001A NOT READY(26:TPV Table Restore Fail from System Area)

NRDY (Factor 27)

Error

M E207001B NOT READY(27:TPV Table Restore Fail to BUD)

End of rebuild to HS
(Bad Data)

Error

M 21810xxx RAID Group#0xxx recovered end of Rebuild processing

xxx : RLU number

End of rebuild to DV
(Bad Data)

Error

M 21810xxx RAID Group#0xxx recovered end of Rebuild processing

xxx : RLU number

Disconnected intra-cabinet path

Error

M 0732MMpp Remote Copy Path (CM#xx CA#yy PORT#pp) Not Available

MM : Module ID
pp : Port number
xx : CM number
yy : CA Slot number

REC automatic HALT occurrence

Error

M 13CF11xx REC Buffer HALT occurred.(xx)

xx : 00 is path error, 01 heavy load, 02 ERROR

Use capacity of Pool has changed.
NORMAL -> CAUTION

Warning

M E8010xxx TPP#xxx turned to CAUTION(decrease of available capacity)

xxx : Thin Provisioning Pool number (hexadecimal notation)

Use capacity of Pool has changed.
NORMAL or CAUTION -> WARNING

Warning

M E8020xxx TPP#xxx turned to WARNING(decrease of available capacity)

xxx : Thin Provisioning Pool number (hexadecimal notation)

Lack of pool capacity

Error

M E8050xxx TPP#xxx was all allocated

xxx : Thin Provisioning Pool number (hexadecimal notation)

Use capacity of Ftier Pool has changed.
NORMAL -> CAUTION

Warning

M E8070xxx FTRP#xxx turned to CAUTION(decrease of available capacity)

xxx : FTRP number (hexadecimal notation)

Use capacity of Ftier Pool has changed.
NORMAL or CAUTION -> WARNING

Warning

M E8080xxx FTRP#xxx turned to WARNING(decrease of available capacity)

xxx : FTRP number (hexadecimal notation)

Lack of Ftier pool capacity

Error

M E8090xxx FTRP#xxx was all allocated

xxx : FTRP number (hexadecimal notation)

Copy session
[Active -> Error]

Error

M 13CE0001 Error session was detected. (Local:xxxxx Remote:xxxxx)

xxxxx : Number of copy sessions that status is Error

Copy session
[Suspend -> Error]

Error

M 13CE0002 Foreseen error session was detected. (Local:xxxxx Remote:xxxxx)

xxxxx : Number of copy sessions that status changed from Suspend to Error

Copy session
[Active -> Halt]

Error

M 13CE0003 Halt session was detected. (Remote:xxxxx)

xxxxx : Number of copy sessions that status is Halt

Copy session
[Error -> Idle]

Error

M 13CE0004 Error session was cleared.

Copy session
[Suspend -> Error -> Idle]

Error

M 13CE0005 Foreseen error session was cleared.

Copy session
[Halt -> Active]

Error

M 13CE0006 Halt session was cleared.

Key Management Server communication Error

Error

M E928xxyy Key Management Server communication Error (Key Server ID #xx)(Key Group ID#yy)

xx : Key server ID
yy : Key group ID

Recovery Notification

Target

Level

Event Display

Remarks

CM Warning recovery

Information

R 01SSMM00 Controller Module#m(zz) Normal <pp ss rr>

SS : Parts subtype
UU : Module ID
m : CM number
zz : Model
pp : Parts number
ss : Serial number
rr : Revision

CM Expander Warning recovery

Information

R 01SSMM0v Controller Module#m(zz) EXP#v Normal <pp ss rr>

SS : Parts subtype
UU : Module ID
v : Device number
m : CM number
zz : Model
pp : Parts number
ss : Serial number
rr : Revision

IOM6 Warning recovery

Information

R 90SSUU0n IOM6 DE#UU/IOM#n Normal <pp ss rr>

SS : Parts subtype
UU : DE ID
n : EXP number
pp : Parts number
ss : Serial number
rr : Revision

CPSU Alarm recovery (AC-Fail clear)

Information

R 73000n00 Power Supply Unit/CPSU#n Normal <pp ss rr>

N : Side 0, side 1
pp : Parts number
ss : Serial number
rr : Revision

PSU Alarm recovery (AC-Fail clear)

Information

R D2SSUU0n Power Supply Unit DE#UU/PSU#n Normal <pp ss rr>

SS : Parts subtype
UU : DE ID
N : Side 0, side 1
pp : Parts number
ss : Serial number
rr : Revision

CE exhaust temperature alarm recovery

Information

R 7A000000 CE Exhaust temperature Normal

CE intake air temperature alarm recovery

Information

R 7B000000 CE Intake temperature Normal

DE exhaust temperature alarm recovery

Information

R DASSUU00 DE Exhaust temperature DE#UU Normal

SS : Parts subtype
UU : DE ID

DE intake air temperature alarm recovery

Information

R DBSSUU00 DE Intake temperature DE#UU Normal

SS : Parts subtype
UU : DE ID

CA Port Link Status Notification

Target

Level

Event Display

Remarks

CA port link status

Information

I 03000001 The status of Link became $a in CM#$b CA#$c Port#$d.

$a : Link Status (LinkUp, LinkDown)
$b : CM number (0 - 7)
$c : CA number (0 - 3)
$d : Port number (0 - 3)