Top
Systemwalker Operation Manager  Message Guide
FUJITSU Software

3.3.2 Detail Error Messages

Failed to initialize the socket.(YYY:ZZZ)

[Description]

Network setup may not be performed.

[Parameter]

YYY : Error code

ZZZ : System error code

[System Action]

Aborts processing.

[User Response]

Contact your system administrator.

[System Administrator Response]

Perform network setup.

Timed-out. (YYY:ZZZ)

[Description]

A timeout occurred on the client.

[Parameter]

YYY : Error code

ZZZ : System error code

[System Action]

Aborts processing.

[User Response]

Contact your system administrator.

[System Administrator Response]

Change the timeout interval according to the following procedure:

[Windows version]

Confirm the method of changing the timeout interval with a Fujitsu's system engineer.

[UNIX version]

  1. Confirm the link source file of the /opt/systemwalker/etc/MpFwsec.ini file.

    1. ls -l /opt/systemwalker/etc/MpFwsec.ini

  2. Check the timeout interval currently specified.

    1. /opt/FJSVfwseo/bin/secgetini -f filename(*) -s Connection -k TimeOut -i

  3. Change the timeout interval.

    1. /opt/FJSVfwseo/bin/secsetini -f filename(*) -s Connection -k TimeOut -v timeoutinterval (unit: milliseconds)

    (*) The name of the link source file name confirmed in 1)

Failed to receive data. (YYY:ZZZ)

[Description]

A timeout occurred on the server.

[Parameter]

YYY : Error code

ZZZ : System error code

[System Action]

Aborts processing.

[User Response]

Contact your system administrator.

[System Administrator Response]

Change the timeout interval.

Failed to forward the data. (YYY:ZZZ)

[Description]

The network may be overloaded.

[Parameter]

YYY : Error code

ZZZ : System error code

[System Action]

Aborts processing.

[User Response]

Contact your system administrator.

[System Administrator Response]

Run the network with lesser loads.

Failed to get port number. (YYY:ZZZ)

[Description]

No port number is specified.

[Parameter]

YYY : Error code

ZZZ : System error code

[System Action]

Aborts processing.

[User Response]

Contact your system administrator.

[System Administrator Response]

Set a port number for security in the services file. See the Systemwalker Operation Manager Installation Guide for how to set a port number.

Failed to login to host. (YYY:ZZZ)

[Description]

Wrong user name or password was entered.

[Parameter]

YYY : Error code

ZZZ : System error code

[System Action]

Aborts processing.

[User Response]

Check the user name and password you entered.

Failed to connect with the host. (YYY:ZZZ)

[Description]

The service is paused or the host name is incorrect.

[Parameter]

YYY : Error code

ZZZ : System error code

[System Action]

Aborts processing.

[User Response]

Confirm the host name.

[System Administrator Response]

Start the service if it has been paused.

Failed to get memory. (YYY:ZZZ)

[Description]

Insufficient memory.

[Parameter]

YYY : Error code

ZZZ : System error code

[System Action]

Aborts processing.

[User Response]

Close other applications.

Virtually failed. (YYY:ZZZ)

[Description]

Failed to check access rights.

[Parameter]

YYY : Error code

ZZZ : System error code

[System Action]

Aborts processing.

[User Response]

Contact your system administrator.

[System Administrator Response]

Collect security information with the Maintenance Information Collection Tool and contact a Fujitsu's system engineer.

[Data Collection]

[Windows version]

On the Maintenance Information Collection Tool, check Framework and Security.

[UNIX version]

Use the swcolinf maintenance information collection command (for servers) to collect the information. See the Systemwalker Operation Manager Reference Guide for the use of the swcolinf command.

[Windows]Not validated. (YYY:ZZZ)

[Description]

The dynamic link library security.dll may not exist in the system directory.

[Parameter]

YYY : Error code

ZZZ : System error code

[System Action]

Aborts processing.

[User Response]

Contact your system administrator.

[System Administrator Response]

Collect security information with the Maintenance Information Collection Tool and contact a Fujitsu's system engineer.

[Data Collection]
[Windows version]

On the Maintenance Information Collection Tool, check Framework and Security.

[UNIX version]

Use the swcolinf maintenance information collection command (for servers) to collect the information. For the swcolinf command, see the Systemwalker Operation Manager Reference Guide.