Top
Systemwalker Desktop Patrol V14g Operation Guide: for Administrators
Systemwalker

7.5.3 Usage mode of Regular Confirmation and Installation of Security Patches (Use as Per Original Setup)

CS automatically acquires the security patches made public by Microsoft company. The security patches will be regularly confirmed on CT, when there are security patches to be installed, installation of the security patches will begin after the confirmation message is displayed. Whether it is necessary to install the security patches will be decided by the user’s intention.

In addition, in this usage mode, the user can install the security patches without having to log on Windows. At this time, message of installation confirmation won’t be displayed.


Use Chart

See below for use chart of the security patches of regular confirmation and installation.

Symbol

Symbol meaning

Windows startup and shutdown.

is to startup Windows, is to shutdown Windows.

Log on and log off Windows.

is to log on Windows, is to log off Windows.

Installation of security patches.

Collection Inventory information after installation of security patches is done.

When installation of the security patches requires restart of Windows, collect Inventory information after restart of Windows.

In the usage mode of security patches of regular confirmation and installation, whether there are security patches needed to be installed to CT will be confirmed as per the interval(original value: 180 minutes) of the confirmation policy.

In the original setup, installation of the security patches will process upon log on of Windows.

Through the following setup change, the user can install the security patches even without log on Windows.

Use chart of security patches installation without log on Windows is show as below.

Symbol

Symbol meaning

Windows startup and shutdown.

◆━ is to startup Windows, ━◆ is to shutdown Windows.

Log on and log off Windows.

is to log on Windows, is to log off Windows.

Installation of security patches.

Collect Inventory information after installation of security patches is done.

If installation of the security patches requires restart of Windows, collect Inventory information after restart of Windows.


Point of Setup

No need for setup when using as per the original setup.

In addition, please refer to “7.2 Setup” for the setup needed for installation of the security patches. It explains herein the key points of set up at the Client.


Setup at Client

See below for Settings of tab of “patch installation” in “Basic operation policy” in “Customize various policies” in “Policy Group Management” in “Environment Setup”.

See below for the necessary setup items. The optional items will be set up as needed.

Setup item

Set value

Mandatory/optional

”Automatic installation of security patch”

Select one of the following setups.

  • Regularly installed when connecting the power

  • Regularly installed when logging on

Mandatory