7.5.4 Operation of Security Patches Installation at Night

In the operation of security patches installation at night, the security patches made public by Microsoft company will be acquired and installed to CT at night, therefore there is no impact on the business in the day.

It is necessary to turn on the CT power for installation of the security patches. When the power is turned off, it won’t be possible to install the security patches.

Perform the following corresponding actions.

Note) Wakeup On LAN function needs support from the PC itself. Please refer to the PC’s operation instructions for support status of the PC itself.


Operation Image

See below for use chart of installation of the security patches at night.

Symbol

Symbol meaning

Windows startup and shutdown.

◆━ is to startup Windows, ━◆ is to shutdown Windows.

Installation of security patches.

Collect Inventory information after installation of security patches is done.

If installation of the security patches requires restart of Windows, collect Inventory information after restart of Windows.

In the usage mode of security patches installation at night, whether there are security patches needed to be installed to CT will be confirmed as per the interval(original value: 180 minutes) of the confirmation policy.

Point of Setup

To realize installation of the security patches at night, it is necessary to finish the setup in “Environment Setup” in the Main Menu.

In addition, please refer to “7.2 Setup” for the setup needed for installation of the security patches. It explains herein the key points of set up at the Client.


Setup at Client

See below for Settings of tab of “patch Installation” in “Basic operation policy” in “Customize various policies” in “Policy Group Management” in “Environment Setup”.

Compulsory setup items are shown as below. Settings of an optional item should be performed according to usage needs.

Setup item

Set value

Mandatory/optional

”Automatic installation of security patch”

Regularly installed when connecting the power

Mandatory

”Installation is limited to specified time frame only”

Selection

Mandatory

”Restart the PC automatically without displaying the message after patch installation”

Yes

Optional(Note)

”Display message when the security patch installation file exists”

No

Mandatory

”Display message during installation process”

No

Mandatory

”Display message after the installation has completed”

No

Mandatory

”Error message displayed when the installation retry limit is exceeded”

No

Mandatory

Note) for the security patches require restart of OS, installation won’t be completed without the restart, therefore, even though there are following security patches to be installed, the next security patch won’t be installed.