ETERNUS SF Storage Cruiser 14.1 Message Guide

1.2 Messages of swsag prefix

swsag0001

Command terminated normally.

Explanation

The command was executed successfully.

System action

The command is completed normally.

System administrator response

None

swsag0002

Since the selected LogicalVolume has already been set for another HBA, there is a possibility of data corruption when the system is not used for a multi path driver/ Cluster environment.

Explanation

An access path has already been set by another host bus adapter (HBA) for the area (LUN) of the GR series (storage) for which the access path is to be set. Therefore, the data via the relevant access path may be damaged by access from that host bus adapter, except when constructing a system that requires common area access setting in a SynfinityCLUSTER or another cluster (nodal failover) environment or multipath disk control (MPLB, MPHD) environment.

System action

The command is completed normally.

System administrator response

Because it is dangerous to set a relevant access path except when constructing a cluster or multipath control environment, cancel this setting. When constructing a cluster or multipath environment, check and set the access path carefully.

swsag0004

Unexpected condition detected for diagnostic access path.

Explanation

Access path diagnosis cannot be performed.

System action

Interrupt the access path diagnosis.

System administrator response

The access path cannot be diagnosed. Check the LAN connection with the server node to be diagnosed.

swsag0005

A path failure was detected.

Explanation

A path error was detected as a result of access path diagnosis.

System action

Interrupts the processing upon the detection of a path error during access path diagnosis

System administrator response

Check the connection of the physical fibre channel that forms the access path.

swsag0006

Access path was defined normally for server node. You can make device path of server node using server node device awareness method (e.g. server node reboot or dynamic reconfiguration function.).

Explanation

WWPN binding for Fibre Channel HBA was set in the server node, and LUN information was set in kernel/drv/sd.conf. The server node must be rebooted in reconfigure mode to reconfigure the device special file. The server node need not be rebooted, however, if it supports the dynamic reconfiguration function.

System action

The command is completed normally.

System administrator response

Reboot the sever node in reconfigure mode.

(This is necessary only if the server node does not support the dynamic reconfiguration function.)

swsag0007

Access path was defined normally for server node and storage. You can make device path of server node using server node device awareness method (e.g. server node reboot or dynamic reconfiguration function.) after the reboot of selected storage.

Explanation

WWPN binding for Fibre Channel HBA was set in the server node, and LUN information was set in kernel/drv/sd.conf. Also, the host affinity was set for the storage.

To reconfigure the device special file on the server node, first restart the storage and, after it has restarted normally, reboot the target server node in reconfigure mode. The server node need not be rebooted, however, if it supports the dynamic reconfiguration function.

System action

The command is completed normally.

System administrator response

Restart the storage and then reboot the server node in reconfigure mode. (This is necessary only if the server node does not support the dynamic reconfiguration function.)

swsag0008

Access path was defined normally for server node. You can make device path of server node using server node device awareness method (e.g. server node reboot or dynamic reconfiguration function.).

Explanation

WWPN binding for Fibre Channel HBA was set on the server node, and LUN information was set in kernel/drv/sd.conf. The server node must be rebooted in reconfigure mode to reconfigure the device special file. The server node need not be rebooted, however, if it supports the dynamic reconfiguration function.

System action

The command is completed normally.

System administrator response

Reboot the server node in reconfigure mode. (This is necessary if the server node does not support the dynamic reconfiguration function.)

swsag0009

Access path was defined normally for storage. You can make device path of server node using server node device awareness method (e.g. server node reboot or dynamic reconfiguration function.) after the reboot of selected storage.

Explanation

A host affinity operation was performed for the storage. Restart the storage to enable the storage settings, and then reboot the server node in reconfigure mode to reconfigure the device special file. The server node need not be rebooted, however, if it supports the dynamic reconfiguration function.

System action

The command is completed normally.

System administrator response

Restart the storage to enable the storage settings. Then, reboot the server node in reconfigure mode. (This is necessary only if the server node does not support the dynamic reconfiguration function.)

swsag0010

The command terminated normally.

Explanation

The command was executed successfully.

System action

The command is completed normally.

System administrator response

None

swsag0011

Access path was defined normally for switch. You can make device path of server node using server node device awareness method (e.g. server node reboot or dynamic reconfiguration function.).

Explanation

Zoning was set for the switch to define the access path.

System action

The command is completed normally.

System administrator response

The target server node must be rebooted in reconfigure mode to enable the access path settings. (This is necessary only if the server node does not support the dynamic reconfiguration function.)

swsag0012

Access path was defined normally for server node and switch. You can make device path of server node using server node device awareness method (e.g. server node reboot or dynamic reconfiguration function.).

Explanation

For access path definition, HBA WWPN binding was set for the server node, /kernel/drv/sd.conf was set, and zoning was set for the switch.

System action

The command is completed normally.

System administrator response

The target server node must be rebooted in reconfigure mode to enable the access path settings. (This is necessary only if the server node does not support the dynamic reconfiguration function.)

swsag0013

Access path was defined normally for server node and switch and storage. You can make device path of server node using server node device awareness method (e.g. server node reboot or dynamic reconfiguration function.) after the reboot of selected storage.

Explanation

For access path definition, HBA WWPN binding was set for the server node, /kernel/drv/sd.conf was set, and zoning was set for the switch.

System action

The command is completed normally.

System administrator response

To enable the access path settings, restart the target storage and, after it has started normally, reboot the target server node in reconfigure mode. (This is necessary only if the server node does not support the dynamic reconfiguration function.)

swsag0014

Access path was defined normally for server node and switch. You can make device path of server node using server node device awareness method (e.g. server node reboot or dynamic reconfiguration function.).

Explanation

For access path definition, HBA WWPN binding was set for the server node, /kernel/drv/sd.conf was set, and zoning was set for the switch.

System action

The command is completed normally.

System administrator response

The target server node must be rebooted in reconfigure mode to enable the access path settings. (This is necessary only if the server node does not support the dynamic reconfiguration function.)

swsag0015

Access path was defined normally for switch and storage. You can make device path of server node using server node device awareness method (e.g. server node reboot or dynamic reconfiguration function.) after the reboot of selected storage.

Explanation

To define the access path, zoning was set for the switch and host affinity was set for the storage.

System action

The command is completed normally.

System administrator response

To enable the access path settings, restart the target storage and, after it has started normally, reboot the target server node in reconfigure mode. (This is necessary only if the server node does not

port the dynamic reconfiguration function.)

swsag0016

The access path setting was executed normally.

Explanation

Access path setting was performed normally.

System action

The command is completed normally.

System administrator response

None

swsag0017

New device(s) was/were detected.

Explanation

A new device was detected.

System action

The command is completed normally.

System administrator response

Register the device for management.

swsag0018

The selected IP device cannot be found.

Explanation

No new device could be detected at the specified IP address.

System action

The command is completed normally.

System administrator response

Check whether the specified IP address and network environment settings for the Managed device and the settings for detecting the Managed device are valid.

Refer to "Chapter 4 Environment Configuration" and "D.4.1 No detection of device is possible" in the ETERNUS SF Storage Cruiser User's Guide.

swsag0019

Some devices' access path was modified (XXXX_NAME). Reboot of some device are required to enable definition (REBOOT_XXXX_NAME). 'EDIT_HBA_NAME' means checking driver configuration file (sd.conf/st.conf/etc...) and editing by manual if necessary is required. :
XXXX_NAME="%name"
REBOOT_XXXX_NAME="%name"
EDIT_HBA_NAME=%name

Explanation

SAN configuration information (access path definition) for some devices was changed. For the server node, the HBA WWPN binding and /kernel/drv/sd.conf settings were changed. For the switch, the zoning settings were changed. For the storage, the host affinity settings were changed. The device is indicated by XXXX_NAME, where XXXX shows the device type such as HOST, SWITCH, or STORAGE.

If the device definition files (sd.conf/st.conf etc.) are relevant to HBA of a server node and are checked and deemed it is a necessity, then it is necessary to edit.

The device may need to be restarted depending on the device type or the software or hardware status. In this case, the device is indicated by REBOOT_XXXX_NAME, where XXXX is the device type, such as HOST, SWITCH, or STORAGE.

Parameters

%name : Device name

System action

The command is completed normally.

System administrator response

If the device definition files (sd.conf/st.conf etc.) are relevant to HBA of a server node and are checked and deemed it is a necessity, then it is necessary to edit.

Restart the device that needs to be restarted.

swsag0020

A problem occurred during this command operation affecting some devices. Some operation(s) failed or was/were skipped (ERR_XXXX_NAME/SKIP_XXXX_NAME). 'EDIT_HBA_NAME' means checking driver configuration file (sd.conf/st.conf/etc...) and editing by manual if necessary is required. :
ERR_XXXX_NAME="%name", "%msg"
SKIP_XXXX_NAME="%name", "%msg"
EDIT_HBA_NAME="%name"

Explanation

An attempt was made to change the SAN configuration information (access path definition) for some devices but it failed or was skipped for a certain device or devices.

If SAN configuration information (access path definition) could not be changed for a device, the device is indicated by ERR_XXXX_NAME, where XXXX shows the device type such as HOST, SWITCH, or STORAGE. The failure cause is also indicated.

If the device definition files (sd.conf/st.conf etc.) are relevant to HBA of a server node and are checked and deemed it is a necessity, then it is necessary to edit.

If processing was skipped for a device, the device is indicated by SKIP_XXXX_NAME, where XXXX shows the device type such as HOST, SWITCH, or STORAGE.

Parameters

%name : Device name
%msg : Detail information (message)

System action

Partially completes the command

System administrator response

Check the error information and then re-enter the command.

If the device definition files (sd.conf/st.conf etc.) are relevant to HBA of a server node and are checked and deemed it is a necessity, then it is necessary to edit.

(Re-execution may not be necessary depending on the command option. Change the SAN configuration information for each device directly (using Telnet or the Web server node function.). )

swsag0021

The access path for some devices was modified (XXXX_NAME). Reboot of some devices required to enable definition (REBOOT_XXXX_N AME). Also, a problem occurred during this operation. Some operation(s) failed or was/were skipped (ERR_XXXX_NAME/SKIP_XXXX_NAME). 'EDIT_HBA_NAME' means checking driver configuration file(sd.conf/st.conf/etc..) and editing by manual if necessary is required. :
XXXX_NAME="%name"
REBOOT_XXXX_NAME="%name"
ERR_XXXX_NAME="%name", "%msg"
SKIP_XXXX_NAME="%name", "%msg"
EDIT_HBA_NAME="%name"

Explanation

An attempt was made to change the SAN configuration information (access path definition) for multiple devices.

That device for which the SAN configuration information (access path definition) could be changed is indicated by XXXX_NAME, where XXXX is the device type such as HOST, SWITCH, or STORAGE. (For the server node, the HBA WWPN binding and /kernel/drv/sd.conf settings were changed. For the switch, the zoning settings were changed. For the storage, the host affinity settings were changed.) The device may need to be restarted depending on the device type or the software or hardware status. In this case, the device is indicated by REBOOT_XXXX_NAME.

If the device definition files (sd.conf/st.conf etc.) are relevant to HBA of a server node and are checked and deemed it is a necessity, then it is necessary to edit.

If the SAN configuration information could not be changed for a device, the device is indicated by ERR_XXXX_NAME and the failure cause is also indicated. Any device for which processing was skipped is indicated by SKIP_XXXX_NAME.

Parameters

%name : Device name
%msg : Message code message

System action

Partially completes the command

System administrator response

Restart the device that needs to be restarted.

If the device definition files (sd.conf/st.conf etc.) are relevant to HBA of a server node and are checked and deemed it is a necessity, then it is necessary to edit.

Check the information for the device for which processing failed or was skipped, and then re-execute the processing.

(Re-execution may not be performed depending on the command option. Change the SAN configuration information for each device directly (using Telnet or the Web server node function). )

swsag0022

The selected IP device already exists in DB of administrative server.

Explanation

The device that responds to the specified IP address already exists in the database.

System action

The command is completed normally.

System administrator response

Check whether the entered IP address is valid.

swsag0023

Deleting the device terminated normally.

Explanation

The registered device was deleted successfully.

System action

The command was executed successfully.

System administrator response

None

swsag0024

Deleting the device terminated normally. During deleting the device, some processing of deleting access paths was done.
%detail_Information

Explanation

Registered devices were deleted. The access path subject to the deletion processing was processed.

Parameters

%detail_information : Detail information on the result of access path processing

System action

The command was executed successfully.

System administrator response

Follow the instructions given in the detail information. If necessary, save the detail information.

swsag0025

Deleting the device terminated. During deleting the device, some processing of deleting access paths was done. Some problems found.
%detail_Information

Explanation

Registered devices were deleted. The access path subject to deletion processing was processed. A problem was detected during the access path processing.

Parameters

%detail_information : Detail information on the result of access path processing

System action

Partially completes the command.

System administrator response

Follow the instructions given in the detail information. If necessary, save the detail information.

swsag0030

A new Fujitsu RAID device (Managed by GRSC) was detected.

Explanation

A new Fujitsu-manufactured RAID device was detected.

System action

The command was processed normally.

System administrator response

None

swsag0031

The selected IP Fujitsu RAID device cannot be found.

Explanation

A Fujitsu RAID device having the specified IP address could not be detected.

System action

The command was processed normally.

System administrator response

Check the IP address.

swsag0032

The selected IP Fujitsu RAID device (Managed by GRC) already exists in DB of administrative server.

Explanation

The Fujitsu RAID device having the specified IP address is already registered in the database.

System action

The command was processed normally.

System administrator response

Check the IP address.

swsag0033

Adding WWPN Zoning to the switch terminated normally. :
DONE_SWITCH_NAME="%name"

Explanation

WWPN Zoning has been set for the switch.

Parameters

%name : Switch name

System action

The command was processed normally.

System administrator response

None

swsag0034

Processing to switch is skipped. :
SKIP_SWITCH_NAME="%name"

Explanation

No processing was performed for the switch.

Parameters

%name : Switch name

System action

Interrupts the command processing.

System administrator response

For the skipped switch, check whether the device monitoring status is normal or check the firmware version, and then re-enter the command.

swsag0035

Adding WWPN Zoning to the switch terminated normally. Also processing to switch is skipped. :
DONE_SWITCH_NAME="%name"
SKIP_SWITCH_NAME="%name"

Explanation

The zone setting command was executed for one switch and processing was skipped for another.

Parameters

%name : Switch name

System action

Partially completes the command.

System administrator response

Check the error information and then re-enter the command.

For the skipped switch, check whether the device monitoring status is normal or check the firmware version, and then re-enter the command.

swsag0036

Deleting WWPN Zoning from the switch terminated normally. :
DONE_SWITCH_NAME="%name"

Explanation

The WWPN zoning setting has been deleted from the switch.

Parameters

%name : Switch name

System action

The command is completed normally.

System administrator response

None

swsag0037

Deleting WWPN Zoning from the switch terminated normally. Also processing to switch is skipped. :
DONE_SWITCH_NAME="%name"
SKIP_SWITCH_NAME="%name"

Explanation

The zone setting command was executed for one switch and processing was skipped for another.

Parameters

%name : Switch name

System action

Partially completes the command.

System administrator response

Check the error information and then re-enter the command.

For the skipped switch, check whether the device monitoring status is normal or check the firmware version, and then re-enter the command.

swsag0038

Some storage's access path was modified. Reboot of the storages are required to enable definition. :
REBOOT_STORAGE_NAME="%name"

Explanation

SAN configuration information for some storage devices was changed.

Parameters

%name : Storage name

System action

The command was executed successfully.

System administrator response

Restart the displayed storage.

swsag0039

A problem occurred during this command operation affecting some storages/switch. Some operation(s) failed or was/were skipped. :
SKIP_STORAGE_NAME="%name"
ERR_STORAGE_NAME="%name"
ERR_SWITCH_NAME="%name"

Explanation

A problem was detected during command processing for some storages or switches such that some devices were terminated abnormally, or processing for some devices was interrupted.

Parameters

%name : Device name

System action

Partially completes the command.

System administrator response

For the switch or storage for which processing was skipped or which was terminated abnormally, check whether the device status is normal. For the switch for which processing was skipped, also check the firmware version.

swsag0040

The access paths for same storages were modified. Reboot of the storages are required to enable definition. Also, a problem occurred during this operation. Some operation(s) failed or was/were skipped. :
REBOOT_STORAGE_NAME="%name"
SKIP_STORAGE_NAME="%name"
ERR_STORAGE_NAME="%name"
ERR_SWITCH_NAME="%name"

Explanation

A problem was detected during command processing for some storages or switches such that some devices were terminated abnormally, or processing for some devices was interrupted.

Parameters

%name : Device name

System action

Partially completes the command.

System administrator response

For the switch or storage for which processing was skipped or which was terminated abnormally, check whether the device status is normal. For the switch for which processing was skipped, also check the firmware version.

swsag0041

The switch is NO_SECURITY status. Processing with switch was skipped.

Explanation

Processing for a switch was skipped because the switch status was NO_SECURITY.

System action

The command is completed normally.

System administrator response

None

(WWPN zoning can also be set for a switch to increase the security level of the entire SAN configuration. )

swsag0042

Skipped processing storage, cause it is a Manually Embedded Device. The switch is NO_SECURITY status. Processing with switch was skipped.

Explanation

Access path processing was not performed for the storage device or FC-CA adapter because the device was set up using the manual embedding function. Perform manual access path processing for the storage that has the host affinity function.

Zoning processing for a switch was skipped because the switch status was NO_SECURITY.

System action

The command is completed normally.

System administrator response

Perform manual access path processing for storage that has the host affinity function.

(WWPN zoning can also be set for a switch to increase the security level of the entire SAN configuration. )

swsag0043

Skipped processing server node, cause it is a Manually Embedded Device. The switch is NO_SECURITY status. Processing with switch was skipped.

Explanation

Access path processing was not performed for the server node or FC-HBA adapter because the device was set up using the manual embedding function. Perform manual access path processing for the server node that has a storage affinity function such as HBA WWPN binding.

Zoning processing for a switch was skipped because the switch status was NO_SECURITY.

System action

The command is completed normally.

System administrator response

Perform manual access path processing for the server node that has a storage affinity function such as HBA WWPN binding.

(WWPN zoning can also be set for the switch to increase the security level of the entire SAN configuration.)

swsag0044

Skipped processing server node and Storage, cause it is a Manually Embedded Device. The switch is NO_SECURITY status. Processing with switch was skipped.

Explanation

Access path processing was not performed for the server node (or FC-HBA adapter) and storage device (or FC-CA adapter) because the devices were set up using the manual embedding function.

Perform manual access path processing for the storage that has the host affinity function. Perform manual access path processing for the server node that has a storage affinity function such as HBA WWPN binding.

Zoning processing for a switch was skipped because the switch status was NO_SECURITY.

System action

The command is completed normally.

System administrator response

Perform manual access path processing for the server node that has a storage affinity function such as HBA WWPN binding.

Perform manual access path processing for storage that has a host affinity function.

(WWPN zoning can also be set for the switch to increase the security level of the entire SAN configuration.)

swsag0045

Please modify HBA and driver configuration file(sd.conf/st.conf/etc..) manually for new devices. Then you can make device path of server node using server node device awareness method (e.g. server node reboot or dynamic reconfiguration function.). The switch is NO_SECURITY status. Processing with switch was skipped.

Explanation

Changing the access path definition for a combination of the specified FC-HBA and storage type is not supported. Set the server node access path manually. After this setting has been made, the target server node must be rebooted in reconfigure mode (this is not necessary if the server node supports the dynamic reconfiguration function.).

Zoning processing for a switch was skipped because the switch status was NO_SECURITY.

System action

Partially completes the command.

System administrator response

Manually change the access path definition related to the specified FC-HBA and storage type.

Then, the target server node must be rebooted in reconfigure mode. (This is necessary only if the server node does not support the dynamic reconfiguration function.)

(WWPN zoning can also be set for the switch to increase the security level of the entire SAN configuration.)

swsag0046

Skipped processing storage, cause it is a Manually Embedded Device. Please modify HBA and driver configuration file (sd.conf/st.conf/etc...) manually for new devices. Then you can make device path of server node using server node device awareness method (e.g. server node reboot or dynamic reconfiguration function.). The switch is NO_SECURITY status. Processing with switch was skipped."

Explanation

Access path processing was not performed for the storage device or FC-CA adapter because the device was set up using the manual embedding function. Perform manual access path processing for the storage that has the host affinity function.

Changing of the access path definition for the combination of the specified FC-HBA and storage type is not supported. Set the server node access path manually.

After the server node access path definition has been changed, the target server node must be rebooted in reconfigure mode (the server node need not be rebooted if the server node supports the dynamic reconfiguration function.).

Zoning processing for a switch was skipped because the switch status was NO_SECURITY.

System action

The command is completed normally.

System administrator response

Manually change the access path definition related to the specified FC-HBA and storage type.

Perform manual access path processing for the storage that has the host affinity function.

Then, the target server node must be rebooted in reconfigure mode. (This is necessary only if the server node does not support the dynamic reconfiguration function.)

(WWPN zoning can also be set for the switch to increase the security level of the entire SAN configuration.)

swsag0047

Access path was defined normally for storage. You can make device path of server node using server node device awareness method (e.g. server node reboot or dynamic reconfiguration function.) after the reboot of selected storage. The switch is NO_SECURITY status. Processing with switch was skipped.

Explanation

A host affinity operation was performed for the storage. Restart the storage to enable the storage settings, and then reboot the server node in reconfigure mode to reconfigure the device special file. The server node need not be rebooted, however, if it supports the dynamic reconfiguration function.

Zoning processing for a switch was skipped because the switch status was NO_SECURITY.

System action

The command is completed normally.

System administrator response

Restart the storage to enable the storage settings. Then, reboot the server node in reconfigure mode. (This is necessary only if the server node does not support the dynamic reconfiguration function.)

(WWPN zoning can also be set for the switch to increase the security level of the entire SAN configuration.)

swsag0048

Access path was defined normally for storage. You can make device path of server node (Manually Embedded server node) using server node device awareness method (e.g. server node reboot or dynamic reconfigure function.) after the reboot of selected storage. Skipped processing server node, cause it is a Manually Embedded Device. The switch is NO_SECURITY status. Processing with switch was skipped.

Explanation

A host affinity operation was performed for the storage.

Access path processing was not performed for the server node or FC-HBA adapter because the device was set up using the manual embedding function.

Perform manual access path processing for the server node that has a storage affinity function, such as HBA WWPN binding.

Restart the storage to enable the storage settings, and then reboot the server node in reconfigure mode to reconfigure the device special file. The server node need not be rebooted, however, if it supports the dynamic reconfiguration function.

Zoning processing for a switch was skipped because the switch status was NO_SECURITY.

System action

The command is completed normally.

System administrator response

Perform manual access path processing for the server node that has a storage affinity function such as HBA WWPN binding.

Restart the storage to enable the storage settings, and then reboot the server node in reconfigure mode to reconfigure the device special file. The server node need not be rebooted, however, if it supports the dynamic reconfiguration function.

(WWPN zoning can also be set for the switch to increase the security level of the entire SAN configuration.)

swsag0049

Access path was defined normally for storage. Please modify HBA and driver configuration file (sd.conf/st.conf/etc...) manually for new devices. And after the reboot of selected storage, you can make device path of server node using server node device awareness method (e.g. server node reboot or dynamic reconfiguration function.). The switch is NO_SECURITY status. Processing with switch was skipped.

Explanation

A host affinity operation was performed for the storage.

Changing of the access path definition for the combination of the specified FC-HBA and storage type is not supported.

Set the server node access path manually.

Restart the storage to enable the storage settings, and then reboot the server node in reconfigure mode to reconfigure the device special file. The server node need not be rebooted, however, if it supports the dynamic reconfiguration function.

Zoning processing for a switch was skipped because the switch status was NO_SECURITY.

System action

Partially completes the command.

System administrator response

Manually change the access path definition related to the specified FC-HBA and storage type.

Restart the storage to enable the storage settings, and then reboot the server node in reconfigure mode to reconfigure the device special file. The server node need not be rebooted, however, if it supports the dynamic reconfiguration function.

(WWPN zoning can also be set for the switch to increase the security level of the entire SAN configuration.)

swsag0050

The switch is NO_SECURITY status. Processing with switch was skipped.

Explanation

Processing for a switch was skipped because the switch status was NO_SECURITY.

System action

The command is completed normally.

System administrator response

None

(WWPN zoning can also be set for the switch to increase the security level of the entire SAN configuration.)

swsag0051

Skipped processing server node, cause it is a Manually Embedded Device. The switch is NO_SECURITY status. Processing with switch was skipped.

Explanation

Access path processing was not performed for the server node or FC-HBA adapter because the device was set up using the manual embedding function. Perform manual access path processing for the server node that has a storage affinity function such as HBA WWPN binding.

Zoning processing for a switch was skipped because the switch status was NO_SECURITY.

System action

The command is completed normally.

System administrator response

Perform manual access path processing for the server node that has a storage affinity function such as HBA WWPN binding.

(WWPN zoning can also be set for the switch to increase the security level of the entire SAN configuration.)

swsag0052

Please modify HBA and driver configuration file (sd.conf/st.conf/etc...) manually for new devices. Then you can make device path of server node using server node device awareness method (e.g. server node reboot or dynamic reconfiguration function.). The switch is NO_SECURITY status. Processing with switch was skipped.

Explanation

Changing of the access path definition for the combination of the specified FC-HBA and storage type is not supported. Set the server node access path manually. After this setting has been made, the target server node must be rebooted in reconfigure mode (this is not necessary if the server node supports the dynamic reconfiguration function.).

Zoning processing for a switch was skipped because the switch status was NO_SECURITY.

System action

Partially completes the command.

System administrator response

Manually change the access path definition related to the specified FC-HBA and storage type.

Then, the target server node must be rebooted in reconfigure mode. (This is necessary only if the server node does not support the dynamic reconfiguration function.)

(WWPN zoning can also be set for the switch to increase the security level of the entire SAN configuration.)

swsag0053

Access path was defined normally for storage. You can make device path of server node using server node device awareness method (e.g. server node reboot or dynamic reconfiguration function.). The switch is NO_SECURITY status. Processing with switch was skipped.

Explanation

A host affinity operation was performed for the storage. The server node must be rebooted in reconfigure mode to reconfigure the server node special file. The server node need not be rebooted, however, if it supports the dynamic reconfiguration function.

Zoning processing for a switch was skipped because the switch status was NO_SECURITY.

System action

The command is completed normally.

System administrator response

Reboot the server node in reconfigure mode. (This is necessary only if the server node does not support the dynamic reconfiguration function.)

(WWPN zoning can also be set for the switch to increase the security level of the entire SAN configuration.)

swsag0054

Access path was defined normally for storage. You can make device path of server node (Manually Embedded server node) using server node device awareness method (e.g. server node reboot or dynamic reconfigure function.). Skipped processing server node, cause it is a Manually Embedded Device. The switch is NO_SECURITY status. Processing with switch was skipped.

Explanation

A host affinity operation was performed for the storage.

Access path processing was not performed for the server node or FC-HBA adapter because the device was set up using the manual embedding function. Perform manual access path processing for the server node that has a storage affinity function such as HBA WWPN binding.

Next, the server node must be rebooted in reconfigure mode to reconfigure the device special file. The server node need not be rebooted, however, if it supports the dynamic reconfiguration function.

Zoning processing for a switch was skipped because the switch status was NO_SECURITY.

System action

Partially completes the command.

System administrator response

Perform manual access path processing for the server node that has a storage affinity function such as HBA WWPN binding.

Next, the server node must be rebooted in reconfigure mode to reconfigure the device special file. The server node need not be rebooted, however, if it supports the dynamic reconfiguration function.

(WWPN zoning can also be set for the switch to increase the security level of the entire SAN configuration.)

swsag0055

Access path was defined normally for storage. Please modify HBA and driver configuration file (sd.conf/st.conf/etc...) manually for new devices. Then you can make device path of server node using server node device awareness method (e.g. server node reboot or dynamic reconfiguration function.). The switch is NO_SECURITY status. Processing with switch was skipped.

Explanation

A host affinity operation was performed for the storage.

Changing of the access path definition for the combination of the specified FC-HBA and storage type is not supported. Set the server node access path manually. Next, the server node must be rebooted in reconfigure mode to reconfigure the device special file. The server node need not be rebooted, however, if it supports the dynamic reconfiguration function.

Zoning processing for a switch was skipped because the switch status was NO_SECURITY.

System action

Partially completes the command.

System administrator response

Manually change the access path definition related to the specified FC-HBA and storage type.

Next, the server node must be rebooted in reconfigure mode to reconfigure the device special file. The server node need not be rebooted, however, if it supports the dynamic reconfiguration function.

(WWPN zoning can also be set for the switch to increase the security level of the entire SAN configuration.)

swsag0056

Access path was defined normally for server node. You can make device path of server node using server node device awareness method (e.g. server node reboot or dynamic reconfiguration function.). The switch is NO_SECURITY status. Processing with switch was skipped.

Explanation

WWPN binding for Fibre Channel HBA was set in the server node, and LUN information was set in kernel/drv/sd.conf.

The server node must be rebooted in reconfigure mode to reconfigure the device special file. The server node need not be rebooted, however, if it supports the dynamic reconfiguration function.

Zoning processing for a switch was skipped because the switch status was NO_SECURITY.

System action

Partially completes the command.

System administrator response

The server node must be rebooted in reconfigure mode. The server node need not be rebooted, however, if it supports the dynamic reconfiguration function.

(WWPN zoning can also be set for the switch to increase the security level of the entire SAN configuration.)

swsag0057

Access path was defined normally for server node. You can make device path of server node using server node device awareness method (e.g. server node reboot or dynamic reconfiguration function.). Skipped processing storage, cause it is a Manually Embedded Device. The switch is NO_SECURITY status. Processing with switch was skipped.

Explanation

WWPN binding for Fibre Channel HBA was set in the server node, and LUN information was set in kernel/drv/sd.conf. The server node must be rebooted in reconfigure mode to reconfigure the device special file. The server node need not be rebooted, however, if it supports the dynamic reconfiguration function.

Access path processing was not performed for the storage device or FC-CA adapter because the device was set up using the manual embedding function. Perform manual access path processing for the storage that has the host affinity function.

Zoning processing for a switch was skipped because the switch status was NO_SECURITY.

System action

Partially completes the command.

System administrator response

Perform manual access path processing for the storage that has the host affinity function.

Next, the server node must be rebooted in reconfigure mode to reconfigure the device special file. The server node need not be rebooted, however, if it supports the dynamic reconfiguration function.

(WWPN zoning can also be set for the switch to increase the security level of the entire SAN configuration.)

swsag0058

Access path was defined normally for server node. Please modify driver configuration file (sd.conf/st.conf/etc...) manually for new devices. Then you can make device path of server node using server node device awareness method (e.g. server node reboot or dynamic reconfiguration function.). The switch is NO_SECURITY status. Processing with switch was skipped.

Explanation

Access path operation was performed for the server node. For server node access path setting, only the configuration file (WWPN binding) of Fibre Channel HBA was edited. First edit the appropriate driver configuration file (such as /kernel/drv/st.conf) manually.

The server node must be rebooted in reconfigure mode to reconfigure the device special file. However, a server node that supports the dynamic reconfiguration function need not be rebooted.

Zoning processing for a switch was skipped because the switch status was NO_SECURITY.

System action

Partially completes the command.

System administrator response

Manually edit the appropriate driver configuration file (such as /kernel/drv/st.conf). Next, the server node must be rebooted in reconfigure mode to reconfigure the device special file. The server node need not be rebooted, however, if it supports the dynamic reconfiguration function.

(WWPN zoning can also be set for the switch to increase the security level of the entire SAN configuration.)

swsag0059

Access path was defined normally for server node. Please modify driver configuration file (sd.conf/st.conf/etc...) manually for new devices. Then you can make device path of server node using server node device awareness method (e.g. server node reboot or dynamic reconfiguration function.). Skipped processing storage, cause it is a Manually Embedded Device. The switch is NO_SECURITY status. Processing with switch was skipped.

Explanation

Access path operation was performed for the server node. For server node access path setting, only the configuration file (WWPN binding) of Fibre Channel HBA was edited. First edit the appropriate driver configuration file (such as /kernel/drv/st.conf) manually.

Access path processing was not performed for the storage device or FC-CA adapter because the device was set up using the manual embedding function. Perform manual access path processing for the storage that has the host affinity function.

The server node must be rebooted in reconfigure mode to reconfigure the device special file. However, a server node that supports the dynamic reconfiguration function need not be rebooted.

Zoning processing for a switch was skipped because the switch status was NO_SECURITY.

System action

Partially completes the command.

System administrator response

Manually edit the appropriate driver configuration file (such as /kernel/drv/st.conf).

Perform manual access path processing for the storage that has the host affinity function.

Next, the server node must be rebooted in reconfigure mode to reconfigure the device special file. The server node need not be rebooted, however, if it supports the dynamic reconfiguration function.

(WWPN zoning can also be set for the switch to increase the security level of the entire SAN configuration.)

swsag0060

Access path was defined normally for server node and storage. You can make device path of server node using server node device awareness method (e.g. server node reboot or dynamic reconfiguration function.) after the reboot of selected storage. The switch is NO_SECURITY status. Processing with switch was skipped.

Explanation

WWPN binding for Fibre Channel HBA was set in the server node, and LUN information was set in kernel/drv/sd.conf. Also, host affinity was set for the storage.

To reconfigure the device special file on the server node, first restart the storage and then, after it has restarted normally, reboot the target server node in reconfigure mode. The server node need not be rebooted, however, if it supports the dynamic reconfiguration function.

Zoning processing for a switch was skipped because the switch status was NO_SECURITY.

System action

The command is completed normally.

System administrator response

Restart the storage and then reboot the server node in reconfigure mode. (This is necessary only if the server node does not support the dynamic reconfiguration function.)

(WWPN zoning can also be set for the switch to increase the security level of the entire SAN configuration.)

swsag0061

Access path was defined normally for server node and storage. Please modify driver configuration file (sd.conf/st.conf/etc...) manually for new devices. Then you can make device path of server node using server node device awareness method (e.g. server node reboot or dynamic reconfiguration function.) after the reboot of selected storage. The switch is NO_SECURITY status. Processing with switch was skipped.

Explanation

Access path operation was performed for the server node. For server node access path setting, only the configuration file (WWPN binding) of the Fibre Channel HBA was edited. First edit the appropriate driver configuration file (such as /kernel/drv/st.conf) manually.

A host affinity operation was performed for the storage. The storage must be restarted to enable the storage settings. Then, the server node must be rebooted in reconfigure mode to reconfigure the device special file. However, a server node that supports the dynamic reconfiguration function need not be rebooted.

Zoning processing for a switch was skipped because the switch status was NO_SECURITY.

System action

Partially completes the command.

System administrator response

Manually edit the appropriate driver configuration file (such as /kernel/drv/st.conf).

Restart the storage to enable the storage settings. Then, reboot the server node in reconfigure mode. (This is necessary only if the server node does not support the dynamic reconfiguration function.)

(WWPN zoning can also be set for the switch to increase the security level of the entire SAN configuration.)

swsag0062

Access path was defined normally for server node. You can make device path of server node using server node device awareness method (e.g. server node reboot or dynamic reconfiguration function.). The switch is NO_SECURITY status. Processing with switch was skipped.

Explanation

WWPN binding for Fibre Channel HBA was set in the server node, and LUN information was set in kernel/drv/sd.conf. The server node must be rebooted in reconfigure mode to reconfigure the device special file. The server node need not be rebooted, however, if it supports the dynamic reconfiguration function.

Zoning processing for a switch was skipped because the switch status was NO_SECURITY.

System action

The command is completed normally.

System administrator response

Reboot the server node in reconfigure mode.

(This is necessary only if the server node does not support the dynamic reconfiguration function.)

(WWPN zoning can also be set for the switch to increase the security level of the entire SAN configuration.)

swsag0063

Access path was defined normally for server node. Please modify driver configuration file (sd.conf/st.conf/etc...) manually for new devices. Then you can make device path of server node using server node device awareness method (e.g. server node reboot or dynamic reconfiguration function.). The switch is NO_SECURITY status. Processing with switch was skipped.

Explanation

Access path operation was performed for the server node. For server node access path setting, only the configuration file (WWPN binding) of Fibre Channel HBA was edited. First edit the appropriate driver configuration file (such as /kernel/drv/st.conf) manually.

The server node must be rebooted in reconfigure mode to reconfigure the device special file. However, a server node that supports the dynamic reconfiguration function need not be rebooted.

Zoning processing for a switch was skipped because the switch status was NO_SECURITY.

System action

Partially completes the command.

System administrator response

Manually edit the appropriate driver configuration file (such as /kernel/drv/st.conf). Next, the server node must be rebooted in reconfigure mode to reconfigure the device special file. The server node need not be rebooted, however, if it supports the dynamic reconfiguration function.

(This is necessary only if the server node does not support the dynamic reconfiguration function.)

(WWPN zoning can also be set for the switch to increase the security level of the entire SAN configuration.)

swsag0064

Access path was defined normally for server node and storage. You can make device path of server node using server node device awareness method (e.g. server node reboot or dynamic reconfiguration function.). The switch is NO_SECURITY status. Processing with switch was skipped.

Explanation

WWPN binding for Fibre Channel HBA was set for the server node, and LUN information was set in kernel/drv/sd.conf. Also, host affinity was set for the storage.

The server node must be rebooted in reconfigure mode to reconfigure the device special file on the server node. The server node need not be rebooted, however, if it supports the dynamic reconfiguration function.

Zoning processing for a switch was skipped because the switch status was NO_SECURITY.

System action

The command is completed normally.

System administrator response

The server node must be rebooted in reconfigure mode to reconfigure the device special file. The server node need not be rebooted, however, if it supports the dynamic reconfiguration function.

(WWPN zoning can also be set for the switch to increase the security level of the entire SAN configuration.)

swsag0065

Access path was defined normally for server node and storage. Please modify driver configuration file (sd.conf/st.conf/etc...) manually for new devices. Then you can make device path of server node using server node device awareness method (e.g. server node reboot or dynamic reconfiguration function.). The switch is NO_SECURITY status. Processing with switch was skipped.

Explanation

Access path operation was performed for the server node. For server node access path setting, only the configuration file (WWPN binding) of the Fibre Channel HBA was edited. The appropriate driver configuration file (such as /kernel/drv/st.conf) must be edited manually first.

A host affinity operation was performed for the storage.

The server node must be rebooted in reconfigure mode to reconfigure the device special file. However, a server node that supports the dynamic reconfiguration function need not be rebooted.

Zoning processing for a switch was skipped because the switch status was NO_SECURITY.

System action

Partially completes the command.

System administrator response

Manually edit the appropriate driver configuration file (such as /kernel/drv/st.conf).

The server node must be rebooted in reconfigure mode to reconfigure the device special file. The server node need not be rebooted, however, if it supports the dynamic reconfiguration function.

(WWPN zoning can also be set for the switch to increase the security level of the entire SAN configuration.)

swsag0066

The switch is NO_SECURITY status. Processing with switch was skipped.

Explanation

Zoning processing for a switch was skipped because the switch status was NO_SECURITY.

System action

Partially completes the command.

System administrator response

None

(WWPN zoning can also be set for the switch to increase the security level of the entire SAN configuration.)

swsag0067

Skipped processing storage, cause it is a Manually Embedded Device. The switch is NO_SECURITY status. Processing with switch was skipped.

Explanation

Access path processing was not performed for the storage device or FC-CA adapter because the device was set up using the manual embedding function. Perform manual access path processing for the storage that has the host affinity function.

Zoning processing for a switch was skipped because the switch status was NO_SECURITY.

System action

Partially completes the command.

System administrator response

Perform manual access path processing for the storage that has the host affinity function.

(WWPN zoning can also be set for the switch to increase the security level of the entire SAN configuration.)

swsag0068

Access path was defined normally for storage. Reboot of the selected server node is required to enable definition after the reboot of selected storage. The switch is NO_SECURITY status. Processing with switch was skipped.

Explanation

A host affinity operation was performed for the storage. The storage must be restarted to enable the storage settings and the server node must be rebooted.

Zoning processing for a switch was skipped because the switch status was NO_SECURITY.

System action

Ends the processing normally.

System administrator response

Restart the storage to enable the storage settings. Then, reboot the server node.

(WWPN zoning can also be set for the switch to increase the security level of the entire SAN configuration.)

swsag0069

The switch is NO_SECURITY status. Processing with switch was skipped.

Explanation

Zoning processing for a switch was skipped because the switch status was NO_SECURITY.

System action

Partially completes the command.

System administrator response

None

(WWPN zoning can also be set for the switch to increase the security level of the entire SAN configuration.)

swsag0070

Access path was defined normally for storage. Reboot of the selected server node is required to enable definition. The switch is NO_SECURITY status. Processing with switch was skipped.

Explanation

A host affinity operation was performed for the storage. The server node must be rebooted.

Zoning processing for a switch was skipped because the switch status was NO_SECURITY.

System action

Partially completes the command.

System administrator response

Reboot the server node.

(WWPN zoning can also be set for the switch to increase the security level of the entire SAN configuration.)

swsag0071

Processing to switch is skipped. Skipped Switch Name (SKIP_SWITCH_NAME):
SKIP_SWITCH_NAME="%name"

Explanation

No processing was performed for the switch.

Parameters

%name : Switch name

System action

Interrupts the command processing.

System administrator response

For the switch for which processing was skipped, also check the firmware version.

swsag0072

New device(s) was/were detected and added.

Explanation

A new device was detected and registered.

System action

Ends the processing normally.

System administrator response

None

swsag0073

New device(s) was/were detected and added. Reboot or SNMP Agent restart of the client server node machine is required to enable the problem-reporting function of client server node machine.

Explanation

A new device was detected and registered. To enable management of the error report settings for the server node, the server node must be rebooted or the SNMP agent in the server node must be restarted.

System action

Ends the processing normally.

System administrator response

Reboot the target server node, or restart the SNMP agent on the target server node.

swsag0101

An Internal Program inconsistency was detected.

Explanation

An internal fatal error was detected.

System action

Interrupts the processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag0102

A critical problem was found in DB of administrative server.

Explanation

Fatal inconsistent data was detected in the CIM database.

System action

Interrupts the processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag0103

An inconsistency was detected in DB of administrative server.

Explanation

Inconsistent data was detected in the CIM database.

System action

Partially completes the command.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag0104

A CIM access error was detected.

Explanation

A CIM error was detected during CIM database access.

System action

Interrupts the processing.

System administrator response

One of the reasons for this message being output may be that the CIM data area is full (/var/sadm/wbem/logr).

Use the "df -k /var/sadm/wbem/logr" command to check whether the disk is full.

If the disk is not full, re-execute processing.

If re-executing the processing fails to solve this problem, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

swsag0105

Input value is invalid. An Internal Program inconsistency was detected.

Explanation

An unexpected value was detected as an input parameter.

System action

Interrupts the processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag0106

The input IP address or device name is incorrect.

Explanation

The format of the input IP address or device name is invalid.

System action

Interrupts the processing.

System administrator response

Check the format of the input IP address or device name.

swsag0107

The Input AffinityGroup was not found in the configuration of the Storage/Ca.

Explanation

An AffinityGroup name that was not defined for the storage device was specified.

System action

Interrupts the processing.

System administrator response

Check whether the AffinityGroup name defined for the storage device was specified correctly.

swsag0108

The input LUN(s) is/are not included in the configured Luns on Storage/CA.

Explanation

An LUN that was not defined for the storage device was specified.

System action

Interrupts the processing.

System administrator response

Check whether the LUN defined for the storage device was specified correctly.

swsag0109

The input Lun lists includes Lun DELETE requirement. Lun deleting is not supported function.

Explanation

LUN cannot be deleted directly.

System action

Interrupts the processing.

System administrator response

LUN can be deleted by deleting the corresponding LUN statement from the /kernel/drv/sd.conf file on the target server node.

swsag0110

An Internal Program Error occurred: The input Hba does not have the information on the last WWPN of the Hba.

Explanation

An internal error was detected in the program.

System action

Interrupts the processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag0111

TargetID cannot be changed.

Explanation

An existing target ID that was set in the server node during access path setting cannot be changed.

System action

Interrupts the processing.

System administrator response

To change the target ID, first delete the access path and then perform access path setting again using a new target ID.

swsag0112

TargetID is already being used.

Explanation

The same target ID as that used for an access path that was already set from the target host bus adapter (HBA) was specified for access path setting.

System action

Interrupts the processing.

System administrator response

Multiple access paths cannot be set with the same target ID from one HBA. Use another target ID.

swsag0113

The device observe status is not appropriate for the operation.

Explanation

The device monitoring status is inappropriate for command execution.

System action

Interrupts the processing.

System administrator response

If the device is not registered, first register the device and then re-enter the command.

If the device status is abnormal, restore the device to the normal status and then re-enter the command.

For access path settings, refer to "D.4.7 Access path setting has failed" in the ETERNUS SF Storage Cruiser User's Guide.

swsag0114

The device observe status of the server node is not appropriate for the operation.

Explanation

The server node device monitoring status is inappropriate for command execution.

System action

Interrupts the processing.

System administrator response

If the server node device is not registered, first register the device and then re-enter the command.

If the server node device status is abnormal, restore the device to the normal status and then re-enter the command.

For access path settings, refer to "D.4.7 Access path setting has failed" in the ETERNUS SF Storage Cruiser User's Guide.

swsag0115

The device observe status of the HBA is not appropriate for the operation.

Explanation

The device monitoring status of the target HBA is inappropriate for executing the specified operation.

System action

Interrupts the processing.

System administrator response

Open to the property window of the target HBA from the side view of the Resource View, and check the monitoring status. According to the monitoring status, do the following:

  • When the status is "timeout"

    The target HBA cannot be recognized. Check whether hardware and drivers function normally. Also check whether the SNIA HBA API library is installed normally. For installation, refer to "Appendix B SNIA HBA API library installation" in the ETERNUS SF Storage Cruiser Installation Guide.

  • When the status is "The access path must be inherited"

    For details on the required action, refer to the "ETERNUS SF Storage Cruiser User's Guide", section "Operation" > "Access Path Management" > "Access path inheritance".

    For details on access path settings, refer to the "ETERNUS SF Storage Cruiser User's Guide", section "Troubleshooting" > "Configuration management functionality" > "Access path setting has failed".

swsag0116

The device observe status of the server node and the HBA are not appropriate for the operation.

Explanation

The device monitoring statuses of the target server node and HBA are inappropriate for executing the specified operation.

System action

Interrupts the processing.

System administrator response

Restore the target server node and HBA to the normal status and then re-execute the operation.

For access path settings, refer to "D.4.7 Access path setting has failed" in the ETERNUS SF Storage Cruiser User's Guide.

swsag0117

The device observe status of the Storage is not appropriate for the operation.

Explanation

The device monitoring status of the target storage is inappropriate for executing the specified operation.

System action

Interrupts the processing.

System administrator response

Restore the target storage to the normal status and then re-execute the operation.

For access path settings, refer to "D.4.7 Access path setting has failed" in the ETERNUS SF Storage Cruiser User's Guide.

swsag0118

The device observe status of the server node and the Storage are not appropriate for the operation.

Explanation

The device monitoring statuses of the target server node and storage are inappropriate for executing the specified operation.

System action

Interrupts the processing.

System administrator response

Restore the target server node and storage to the normal status and then re-execute the operation.

For access path settings, refer to "D.4.7 Access path setting has failed" in the ETERNUS SF Storage Cruiser User's Guide.

swsag0119

The device observe status of the HBA and the Storage are not appropriate for the operation.

Explanation

The device monitoring statuses of the target server node and HBA are inappropriate for executing the specified operation.

System action

Interrupts the processing.

System administrator response

Restore the target HBA and storage to the normal status and then re-execute the operation.

For access path settings, refer to "D.4.7 Access path setting has failed" in the ETERNUS SF Storage Cruiser User's Guide.

swsag0120

The device observe status of the server node, HBA and the Storage are not appropriate for the operation.

Explanation

The device monitoring statuses of the target server node and storage are inappropriate for executing the specified operation.

System action

Interrupts the processing.

System administrator response

Restore the target server node, HBA, and storage to the normal status and then re-execute the operation.

For access path settings, refer to "D.4.7 Access path setting has failed" in the ETERNUS SF Storage Cruiser User's Guide.

swsag0121

The device observe status of the CA is not appropriate for the operation.

Explanation

The device monitoring status of the target CA is inappropriate for executing the specified operation.

System action

Interrupts the processing.

System administrator response

Restore the target CA to the normal status and then re-execute the operation.

For access path settings, refer to "D.4.7 Access path setting has failed" in the ETERNUS SF Storage Cruiser User's Guide.

swsag0122

The device observe status of the server node and the CA are not appropriate for the operation.

Explanation

The device monitoring statuses of the target server node and CA are inappropriate for executing the specified operation.

System action

Interrupts the processing.

System administrator response

Restore the target server node and CA to the normal status and then re-execute the operation.

For access path settings, refer to "D.4.7 Access path setting has failed" in the ETERNUS SF Storage Cruiser User's Guide.

swsag0123

The device observe status of the HBA and the CA are not appropriate for the operation.

Explanation

The device monitoring statuses of the HBA and CA are inappropriate for executing the specified operation.

System action

Interrupts the processing.

System administrator response

Restore the target HBA and CA to the normal status and then re-execute the operation.

For access path settings, refer to "D.4.7 Access path setting has failed" in the ETERNUS SF Storage Cruiser User's Guide.

swsag0124

The device observe status of the server node, HBA and the CA are not appropriate for the operation.

Explanation

The device monitoring statuses of the server node, HBA, and CA are inappropriate for executing the specified operation.

System action

Interrupts the processing.

System administrator response

Restore the target server node, HBA, and CA to the normal status and then re-execute the operation.

For access path settings, refer to "D.4.7 Access path setting has failed" in the ETERNUS SF Storage Cruiser User's Guide.

swsag0125

The device observe status of the Storage and the CA are not appropriate for the operation.

Explanation

The device monitoring statuses of the target storage and CA are inappropriate for executing the specified operation.

System action

Interrupts the processing.

System administrator response

Restore the target storage and CA to the normal status and then re-execute the operation.

For access path settings, refer to "D.4.7 Access path setting has failed" in the ETERNUS SF Storage Cruiser User's Guide.

swsag0126

The device observe status of the server node, Storage and the CA are not appropriate for the operation.

Explanation

The device monitoring statuses of the target server node, storage, and CA are inappropriate for executing the specified operation.

System action

Interrupts the processing.

System administrator response

Restore the target server node, storage, and CA to the normal status and then re-execute the operation.

For access path settings, refer to "D.4.7 Access path setting has failed" in the ETERNUS SF Storage Cruiser User's Guide.

swsag0127

The device observe status of the HBA,Storage and the CA are not appropriate for the operation.

Explanation

The device monitoring statuses of the target HBA, storage, and CA are inappropriate for executing the specified operation.

System action

Interrupts the processing.

System administrator response

Restore the HBA, storage, and CA to the normal status and then re-execute the operation.

For access path settings, refer to "D.4.7 Access path setting has failed" in the ETERNUS SF Storage Cruiser User's Guide.

swsag0128

The device observe status of the server node, HBA,Storage and the CA are not appropriate for the operation.

Explanation

The device monitoring statuses of the target server node, HBA, storage, and CA are inappropriate for executing the specified operation.

System action

Interrupts the processing.

System administrator response

Restore the target server node, HBA, storage, and CA to the normal status and then re-execute the operation.

For access path settings, refer to "D.4.7 Access path setting has failed" in the ETERNUS SF Storage Cruiser User's Guide.

swsag0129

The storage affinity of one HBA is WWNN_BINDING, It is not appropriate for adding to the server node.

Explanation

WWNN (World Wide Node Name) binding is defined for the server node HBA. Because the management unit of this program is WWPN (World Wide Port Name), registration of the relevant server node is restricted.

System action

Interrupts the processing.

System administrator response

Define WWPN binding instead of WWNN binding for the HBA of the server node to be registered, and then perform server node registration again.

swsag0130

The storage affinity of one HBA is PID_BINDING. It is not appropriate for adding to the server node.

Explanation

PID (Fibre Channel PID) binding is defined for the server node HBA. Because the management unit of this program is WWPN (World Wide Port Name), registration of the relevant server node is restricted.

System action

Interrupts the processing.

System administrator response

Define WWPN binding instead of PID binding for the HBA of the server node to be registered, and then perform server node registration again.

swsag0131

The storage affinity of one HBA is TID_BINDING. It is not appropriate for adding to the server node.

Explanation

PID (Fibre Channel TID) binding is defined for the server node HBA. Because the management unit of this program is WWPN (World Wide Port Name), registration of the relevant server node is restricted.

System action

Interrupts the processing.

System administrator response

Define WWPN binding instead of TID binding for the HBA of the server node to be registered, and then perform server node registration again.

swsag0132

The zoning configuration of the switch is WWNNZoning. It is not appropriate for adding to switch.

Explanation

The switch zoning definition includes WWNN.

System action

Interrupts the processing.

System administrator response

Use WWPN for the switch zoning definition to implement correct zoning management.

swsag0133

The switch is connected to a device which is not confirmed whether it is CA or HBA.

Explanation

An adapter, which cannot be recognized as either CA or HBA, is connected to the switch.

System action

Interrupts the processing.

System administrator response

Register CA and HBA information.

swsag0134

Communication with the device could not be executed.

Explanation

The state of device subject to command processing is such that it cannot be detected on the LAN.

System action

Interrupts the processing.

System administrator response

Check the LAN connection of the target device.

swsag0135

No device could be found that was being managed by administrative server for the IP address.

Explanation

An attempt to find the monitored device with the specified IP address failed.

System action

Interrupts the processing.

System administrator response

Check whether the specified IP address is valid.

In some cases, the community name of a device such as fibre channel switch that uses the SNMP protocol for communication may be set to something other than "public" and the community name of the administrative server may not be changed. If so, communication is disabled because of a mismatch of the community name. The community name of the target device needs to be set for the administrative server.

Set the community name by referring to the "SNMP_COMMUNITY_NAME_FOR_IP" parameter provided in "C.2 sanma.conf Parameter" in the ETERNUS SF Storage Cruiser User's Guide, and reflect the contents of the setting file on this software.

For the server, check the network environment and Agent activation.

Also check whether the settings required for device detection have been made. For details of the settings, refer to "Chapter 4 Environment Configuration" in the ETERNUS SF Storage Cruiser User's Guide.

swsag0136

To execute this operation, the Port Type of HBA must be 'N' port.

Explanation

This operation cannot be performed because the HBA FC port type is not set to N.

System action

Interrupts the processing.

System administrator response

Set the HBA FC port type to N. Refer to the manual for information on how to set the port to N.

swsag0137

The Fibre Channel cable is not physically connected.

Explanation

The Fibre Channel cable for the path between the operation target HBA and CA is broken.

System action

Interrupts the processing.

System administrator response

Execute "Refresh" in the resource view, determine where the Fibre Channel cable between the HBA and CA is broken, and then physically re-connect the cable.

If information cannot be obtained from the Fibre Channel cable refer to "D.4.3 Device is not possible to communicate" in the ETERNUS SF Storage Cruiser User's Guide.

swsag0138

There is a critical problem with the FC Port type of HBA, CA or Switch.

Explanation

HBA or CA is not set for the N-type port, or the switch is not set for the F-type port.

System action

Interrupts the processing.

System administrator response

Set the HBA and CA Fibre Channel port connection types to Fabric connection (N-type port). For details of the settings, refer to "Chapter 4 Environment Configuration" in the ETERNUS SF Storage Cruiser User's Guide.

If re-executing the processing displays the same message, it is assumed that the switch port cannot be set to F type for some reasons.

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag0139

There is a problem with the FC port type of HBA/CA (1).

Explanation

The HBA and CA ports were not set to N type.

System action

Interrupts the processing.

System administrator response

Set the HBA and CA Fibre Channel port connection types to Fabric connection (N-type port). For setting procedures, refer to "Chapter 4 Environment Configuration" in the ETERNUS SF Storage Cruiser User's Guide.

swsag0140

There is a problem with the FC port type of HBA/CA (2).

Explanation

The HBA and CA ports were not set to N type.

System action

Interrupts the processing.

System administrator response

Set the HBA and CA Fibre Channel port connection types to Fabric connection (N-type port). For setting procedures, refer to "Chapter 4 Environment Configuration" in the ETERNUS SF Storage Cruiser User's Guide.

swsag0141

The connection route and setup for connection between HBA and CA is not appropriate for setAccessPath().

Explanation

The specified connection route/combination between the HBA and CA is not supported.

System action

Interrupts the processing.

System administrator response

Refer to the manual to determine which connection route/combinations are supported.

swsag0142

A fatal error occurred during the server node operation.

Explanation

An error was detected during command processing for the server node.

System action

Interrupts the processing.

System administrator response

Re-enter the command.

swsag0143

A fatal error occurred during the server node operation. Please call our engineer.(Do not run this operation again.)

Explanation

A fatal error occurred during command execution for the server node.

System action

Interrupts the processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag0144

A fatal error occurred during the storage operation.

Explanation

An error was detected during command processing for the storage.

System action

Interrupts the processing.

System administrator response

Re-enter the command.

swsag0145

Fatal error occurred during switch operation. Server node configuration has already been updated.

Explanation

An error was detected during the execution of this command for the storage. The server node configuration information has been changed from the state existing before the execution of this command.

System action

Setting for the server node was executed but other processing was interrupted.

System administrator response

Re-enter the command.

swsag0146

Fatal error occurred during storage operation and server node error recovery failed. Server node configuration has already been updated.

Explanation

An error was detected during execution of this operation command for the storage.

System action

Setting for the server node was executed but other processing was interrupted.

System administrator response

Re-enter the command.

swsag0147

Fatal error occurred during storage operation and server node error recovery failed. Please call our engineer.(Do not run this operation again.)

Explanation

An error was detected during the execution of this operation command for the storage.

Also, a fatal error was detected in the server node operation.

System action

Interrupts the processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag0148

Fatal error occurred during storage operation. Please call our engineer.(Do not run this operation again.)

Explanation

An error was detected during the execution of this operation command for the storage.

System action

Interrupts the processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag0149

Fatal error occurred during storage operation. Please call our engineer.(Do not run this operation again.) Server node configuration has already been updated.

Explanation

The command was executed for the server node but a fatal error was detected during command execution for the storage.

System action

Setting on the server node was executed but processing for the storage was interrupted.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag0150

Fatal error occurred during storage operation and server node error recovery failed. Server node configuration has already been updated. Please call our engineer.(Do not run this operation again.)

Explanation

A serious error was detected during the execution of this command for the storage. An error was detected during the execution of ERP processing for the server node. The server node configuration information has been changed from the state existing before the execution of this command.

System action

Setting for the server node was executed but processing for the storage was interrupted.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag0151

Fatal error occurred during storage operation and server node error recovery failed. Please call our engineer.(Do not run this operation again.)

Explanation

A serious error was detected during the execution of this command for the storage.

System action

Interrupts the processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag0152

Fatal error occurred during switch operation.

Explanation

An error was detected during the execution of this operation on the switch.

System action

Interrupts the processing.

System administrator response

Re-enter the command.

swsag0153

Fatal error occurred during switch operation. Server node configuration has already been updated.

Explanation

An error was detected during the execution of this command for the switch.

The command was executed successfully for the server node.

System action

Executes the setting on the server node but interrupts the processing on the switch.

System administrator response

Re-enter the command.

swsag0154

Fatal error occurred during switch operation. Server node error recovery failed and server node configuration was updated.

Explanation

An error was detected during the execution of this command for the switch.

The command was executed successfully for the server node.

System action

Setting for the server node was executed but processing for the switch was interrupted.

System administrator response

Re-enter the command.

swsag0155

Fatal error occurred during switch operation and server node error recovery failed. Please call our engineer. (Do not run this operation again.)

Explanation

A serious error was detected during the execution of this command for the storage.

The command was executed for the server node.

System action

Interrupts the processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag0156

Fatal error occurred during switch operation. Server node configuration has already been updated.

Explanation

An error was detected during the execution of this command for the switch.

The command was executed successfully for the server node.

System action

Executes the processing for the server node but interrupts that for the switch.

System administrator response

Re-enter the command.

swsag0157

Fatal error occurred during switch operation and server node error recovery failed. Server node configuration was updated.

Explanation

An error was detected during the execution of this operation for the switch.

The operation was executed successfully for the server node.

System action

Executes the processing on the server node but interrupts that on the switch.

System administrator response

Re-enter the command.

swsag0158

Fatal error occurred during switch operation and server node error recovery failed. Please call our engineer. (Do not run this operation again.)

Explanation

An error was detected during the execution of this operation for the switch.

Also, a fatal error was detected during the execution of this operation for the server node.

System action

Interrupts the processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag0159

Fatal error occurred during switch operation. Storage recovery procedure failed and storage configuration was updated.

Explanation

An error was detected during the execution of this operation for the switch.

This operation was executed successfully for the storage.

System action

Executes the processing for the storage but interrupts that for the switch.

System administrator response

Re-enter the command.

swsag0160

Fatal error occurred during switch operation. Storage recovery procedure failed and storage configuration was updated.

Explanation

An error was detected during the execution of this operation for the switch.

This operation was executed for the storage.

System action

Executes the processing for the storage but interrupts that for the switch.

System administrator response

Re-enter the command.

swsag0161

Fatal error occurred during switch operation. Storage recovery procedure failed and storage and server node configuration was updated.

Explanation

An error was detected during the execution of this operation for the switch.

This operation was executed successfully for the storage and server node.

System action

Executes the processing for the storage and server node but interrupts that for the switch.

System administrator response

Re-enter the command.

swsag0162

Fatal error occurred during switch operation. Storage and server node recovery procedure failed and storage and server node configuration was updated.

Explanation

An error was detected during the execution of this operation for the switch.

This operation was executed successfully for the storage and server node.

System action

Executes the processing for the storage and server node but interrupts that for the switch.

System administrator response

Re-enter the command.

swsag0163

Fatal error occurred during switch operation. Storage and server node recovery procedure failed and storage configuration was updated. Please call our engineer. (Do not run this operation again.)

Explanation

An error was detected during the execution of this operation for the switch.

Also, a fatal error was detected during the execution of this operation for the server node.

This operation was executed successfully for the storage.

System action

Interrupts the processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag0164

Fatal error occurred during switch operation. Storage recovery procedure failed. Please call our engineer. (Do not run this operation again.)

Explanation

An error was detected during the execution of this operation for the switch.

Also, a fatal error was detected during the execution of this operation for the server node.

This operation was executed successfully for the storage.

System action

Interrupts the processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag0165

Fatal error occurred during switch operation. Storage recovery procedure failed. Server node configuration was updated. Please call our engineer. (Do not run this operation again.)

Explanation

An error was detected during the execution of this operation for the switch.

Also, a fatal error was detected during the execution of this operation for the storage.

System action

Interrupts the processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag0166

Fatal error occurred during switch operation. Storage and server node recovery procedure failed. Server node configuration was updated. Please call our engineer. (Do not run this operation again.)

Explanation

An error was detected during the execution of this operation on the switch.

Also, a fatal error was detected during the execution of this operation for the storage.

This operation was executed successfully for the server node.

System action

Executes this operation for the server node but interrupts all other processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag0167

Fatal error occurred during switch operation. Storage and server node recovery procedure failed. Please call our engineer. (Do not run this operation again.)

Explanation

An error was detected during the execution of this operation for the switch.

Also, a fatal error was detected during the execution of this operation for the server node.

System action

Interrupts the processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag0168

Unable to obtain Storage Affinity Information. This operation could not be processed.

Explanation

Storage Affinity Information from the HBA could not be obtained.

System action

Interrupts the processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag0172

Internal Program Error occurred.

Explanation

An internal error was detected in the program.

System action

Interrupts the processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag0173

Server node agent is already communicating with another manager.

Explanation

The Agent of the target server node is busy communicating with another administrative server.

System action

Interrupts the processing.

System administrator response

Re-execute the processing later.

swsag0174

Internal Program Error occurred.

Explanation

An internal error was detected in the program.

System action

Interrupts the processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag0175

Unexpected Exception occurred

Explanation

Unexpected exception processing was detected during a management operation.

This message may be output as a result of one of the following reasons:

  • The target server node failed while it was processing a request issued by the Manager, or communication failed because of a LAN error.

  • The Agent on the relevant server node is stopped.

  • Exception processing other than the above was detected in the program. An unexpected exception occurred.

System action

Interrupts the processing.

System administrator response

  • If the relevant server node failed or a LAN error occurred during communication with the relevant server, remove the cause of the error.

  • If the Agent is stopped, start it.

  • When none of the above items apply,

    Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag0176

Internal Program Error occurred.

Explanation

An internal error was detected in the program.

System action

Interrupts the processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag0177

Internal Program Error occurred.

Explanation

An internal error was detected in the program.

System action

Interrupts the processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag0178

SNMP error occurred in communication with server node.

Explanation

An SNMP error occurred during communication with the server node.

System action

Interrupts the processing.

System administrator response

Check the LAN environment for problems.

swsag0179

Socket error occurred in communication with server node.

Explanation

A SOCKET error occurred during communication with the Agent. A possible cause is that the resources (memory and process tables) of the server node on which the Manager is running have been exhausted. A socket error occurred during communication with the server node.

System action

Interrupts the processing.

System administrator response

Check whether any application that causes a server node resource shortage is running. Also check whether there is an application that generates processes in succession. If resource shortages tend to occur frequently, expand the amount of installed memory.

swsag0180

Unable to find selected server node.

Explanation

The IP address of the server node on which the Manager is running could not be determined.

System action

Interrupts the processing.

System administrator response

  • Review the definition of the address of the server node on which the Manager is running.

  • Check whether the system resources, such as process tables and memory, have been exhausted.

  • Check the LAN for errors.

When none of the above items apply, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

swsag0181

No response from server node agent.

Explanation

This message may be output as a result of any one of the following:

  • The server node to which a processing request was issued by the Manager failed, or communication failed because of a LAN error.

  • The Agent on the relevant server node has stopped.

System action

Interrupts the processing.

System administrator response

If the relevant server failed or a LAN error occurred during communication with the relevant server, remove the failure cause.

When none of the above items apply, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

swsag0182

Socket error occurred in switch/hub communication. The target device address: %IP_ADDRESS

Explanation

A socket error occurred during communication between the Manager and the switch or hub.

Parameters

%IP_ADDRESS : Indicates the IP address of the destination switch or hub on which the error occurred.

System action

Interrupts the processing.

System administrator response

Check whether the target switch or hub is connected to the LAN. Alternatively, check the LAN environment for problems.

swsag0183

Unable to find selected switch/hub. The target device address: %IP_ADDRESS

Explanation

The specified switch or hub was not found.

Parameters

%IP_ADDRESS : Indicates the IP address of the specified switch or hub.

System action

Interrupts the processing.

System administrator response

Check the LAN environment for problems.

In some cases, the community name of a device such as fibre channel switch that uses the SNMP protocol for communication may be set to something other than "public" and the community name of the admin server may not be changed. If so, communication is disabled because of a mismatch of the community name. The community name of the target device needs to be set for the admin server.

Set the community name by referring to the "SNMP_COMMUNITY_NAME_FOR_IP" parameter provided in "C.2 sanma.conf Parameter" in the ETERNUS SF Storage Cruiser User's Guide, and reflect the contents of the setting file on this software.

If the problem persists even after checking the above environment settings, collect the data required for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag0184

Network I/O error occurred in switch/hub communication. The target device address: %IP_ADDRESS

Explanation

A network I/O error occurred during communication between the Manager and the switch or hub.

Parameters

%IP_ADDRESS : Indicates the IP address of the destination switch or hub in which an error occurred.

System action

Interrupts the processing.

System administrator response

Check the applicable switch or hub for errors. Alternatively, check the LAN environment for problems.

In some cases, the community name of a device such as fibre channel switch that uses the SNMP protocol for communication may be set to something other than "public" and the community name of the admin server may not be changed. If so, communication is disabled because of a mismatch of the community name. The community name of the target device needs to be set for the admin server.

Set the community name by referring to the "SNMP_COMMUNITY_NAME_FOR_IP" parameter provided in "C.2 sanma.conf Parameter" in the ETERNUS SF Storage Cruiser User's Guide, and reflect the contents of the setting file on this software.

If the problem persists even after checking the above environment settings, collect the data required for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag0185

Timeout error occurred in switch/hub communication. The target device address: %IP_ADDRESS

Explanation

A time-out was detected during communication between the Manager and the switch or hub.

Parameters

%IP_ADDRESS : Indicates the IP address of the destination switch or hub in which an error occurred.

System action

Interrupts the processing.

System administrator response

Check whether the target switch or hub is connected to the LAN. Alternatively, check the LAN environment for problems.

In some cases, the community name of a device such as fibre channel switch that uses the SNMP protocol for communication may be set to something other than "public" and the community name of the admin server may not be changed. If so, communication is disabled because of a mismatch of the community name. The community name of the target device needs to be set for the admin server.

Set the community name by referring to the "SNMP_COMMUNITY_NAME_FOR_IP" parameter provided in "C.2 sanma.conf Parameter" in the ETERNUS SF Storage Cruiser User's Guide, and reflect the contents of the setting file on this software.

If the problem persists even after checking the above environment settings, collect the data required for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag0186

No response from switch/hub. The target device address: %IP_ADDRESS

Explanation

The specified switch or hub was not found.

Parameters

%IP_ADDRESS : Indicates the IP address of the specified switch or hub.

System action

Interrupts the processing.

System administrator response

Check whether the target switch or hub is connected to the LAN. Alternatively, check the LAN environment for problems.

In some cases, the community name of a device such as fibre channel switch that uses the SNMP protocol for communication may be set to something other than "public" and the community name of the admin server may not be changed. If so, communication is disabled because of a mismatch of the community name. The community name of the target device needs to be set for the admin server.

Set the community name by referring to the "SNMP_COMMUNITY_NAME_FOR_IP" parameter provided in "C.2 sanma.conf Parameter" in the ETERNUS SF Storage Cruiser User's Guide, and reflect the contents of the setting file on this software.

If the problem persists even after checking the above environment settings, collect the data required for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag0187

This device is not supported. The target device address: %IP_ADDRESS

Explanation

The device with the specified IP address is not to be managed.

Parameters

%IP_ADDRESS : Indicates the IP address of the specified switch or hub.

System action

Interrupts the processing.

System administrator response

Check whether the specified IP address is valid.

swsag0188

User Name or Password is incorrect for switch/hub. The target device address: %SYS_NAME:%IP_ADDRESS

Explanation

Login to the switch or hub failed because the user name or password was invalid.

Parameters

%SYS_NAME : Indicates sysName that is set for the switch or hub to which login failed.
%IP_ADDRESS : Indicates the IP address of the switch or hub to which login failed.

System action

Interrupts the processing.

System administrator response

If this message was displayed during device registration, re-execute the processing and enter a valid user name and password.

If this message is displayed on a device that has already been registered, first determine the relevant device from "Detail" and then turn off the device power. Select "Refresh" and then "Delete device". Then, select "Equipment registration" again and enter a valid user name and password.

swsag0189

Another user has logged into switch/hub. Logout and run function again. The target device address: %SYS_NAME:%IP_ADDRESS

Explanation

The Manager could not login to the switch or hub because another user has already logged into the device.

Parameters

%SYS_NAME : Indicates sysName that is set for the switch or hub to which login failed.
%IP_ADDRESS : Indicates the IP address of the switch or hub to which login failed.

System action

Interrupts the processing.

System administrator response

Log out the process logged into the target device, and then re-execute.

If the target device is unknown, determine it from "Detail".

swsag0190

Parse error on telnet for switch/hub. The target device address: %SYS_NAME:%IP_ADDRESS

Explanation

Analysis of the execution results of the TELNET command issued to the switch or hub failed.

Parameters

%SYS_NAME : Indicates sysName that is set for the switch or hub to which login failed.
%IP_ADDRESS : Indicates the IP address of the switch or hub to which login failed.

System action

Interrupts the processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag0191

Command failure on telnet for switch/hub. The target device address: %IP_ADDRESS

Explanation

Execution of the TELNET command issued to the switch or hub failed.

Parameters

%IP_ADDRESS : Indicates the IP address of the switch or hub in which an error occurred.

System action

Interrupts the processing.

System administrator response

Re-enter the command. If execution still fails, the following are possible causes.

  • Check if all the cascade-connected fibre channel switches are registered to this software.
    If not so, register all the switches.

  • Make sure that the icon statuses of all the cascade-connected fibre channel switches are normal (green). If they are not, then check the status of devices. For details on how to do that, refer to the " ETERNUS SF Storage Cruiser User's Guide", section "Operation" > "Resource View" > "Main view", table "Device status indications".

If the above are not applicable, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

swsag0192

Index out of bounds. The target device address: %IP_ADDRESS

Explanation

An attempt was made to access an address outside of the range of the Manager's internal buffer.

Parameters

%IP_ADDRESS : Indicates the IP address of the switch or hub in which an error occurred.

System action

Interrupts the processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag0193

This is not supported device. : %IP_ADDRESS

Explanation

The device with the specified IP address is not to be managed for errors.

Parameters

%IP_ADDRESS : IP address of the device not to be managed

System action

Interrupts the processing.

System administrator response

Check the devices to be managed.

swsag0194

Unrecovered SNMP error occurred. The target device address:%IP_ADDRESS

Explanation

An unrecoverable error occurred during processing of the SNMP protocol.

Parameters

%IP_ADDRESS : Indicates the IP address of the switch or hub in which an error occurred.

System action

Interrupts the processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag0196

Administrative server using zone name is already registered in this switch. Registered zoning name: %TYPE:%NAME (IP:%IP_ADDRESS)

Explanation

The zoning name used by the Manager is already registered as Zone or Alias for a switch.

Parameters

%TYPE : Zoning type (Zone or Alias) of the name that is already used
%NAME : Name that is already used
%IP_ADDRESS : Indicates the IP address of the switch in which an error occurred.

System action

Interrupts the processing.

System administrator response

To set zoning manually, use a name beginning with other than "SNM".

swsag0197

Too many zones for switch. The target device address:%IP_ADDRESS

Explanation

The zone setting limit has been reached.

Parameters

%IP_ADDRESS : Indicates the IP address of the switch in which an error occurred.

System action

Interrupts the processing.

System administrator response

Delete any unnecessary zone settings. If there are no unnecessary zone settings that can be deleted, configure another SAN.

swsag0198

Unable to delete zone for switch. This is because of port zoning possibly due to zone setting not being one-to-one. Zone setting: %ZONES (IP:%IP_ADDRESS)

Explanation

The Manager can delete only one-to-one correspondent WWPN (World Wide Port Name) zone settings.

Parameters

%ZONES : Indicates the zone setting that could not be deleted.
%IP_ADDRESS : Indicates the IP address of the switch in which an error occurred.

System action

Interrupts the processing.

System administrator response

Login directly to the switch and then adjust the zone setting manually.

swsag0200

Firmware version switch/hub not supported. Firmware Version: %VERSION (IP:%IP_ADDRESS)

Explanation

The switch or hub is of an unsupported firmware version.

Parameters

%VERSION : Unsupported firmware version
%IP_ADDRESS : Indicates the IP address of the switch or hub in which an error occurred.

System action

Interrupts the processing.

System administrator response

Firmware not supported ETERNUS SF Storage Cruiser is used for the target device.

Contact your Fujitsu engineer (CE or SE) because patches need to be applied to ETERNUS SF Storage Cruiser.

swsag0201

Registration of SNMP Trap address is full on switch/hub. Failed Registration: %REGISTRATION (IP:%IP_ADDRESS)

Explanation

No more switch or hub SNMP trap send destinations can be registered because the registry is full.

Parameters

%REGISTRATION : Indicates the IP address of the SNMP trap send destination that could not be registered
%IP_ADDRESS : Indicates the IP address of the switch or hub in which the error occurred.

System action

Interrupts the processing.

System administrator response

Login to the switch or hub directly and delete any unnecessary SNMP trap send destinations.

swsag0202

Device-specific class loading error. The target device address: %IP_ADDRESS

Explanation

The device-specific class could not be loaded.

Parameters

%IP_ADDRESS : Indicates the IP address of the device to be processed.

System action

Interrupts the processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag0203

Unexpected Interrupt occurred during processing. The target device address: %IP_ADDRESS

Explanation

An interrupt occurred during processing.

Parameters

%IP_ADDRESS : Indicates the IP address of the device to be processed.

System action

Interrupts the processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag0204

Unexpected error occurred. %IP_ADDRESS

Explanation

An unexpected error occurred.

Parameters

%IP_ADDRESS : Indicates the IP address of the device to be processed.

System action

Interrupts the processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag0205

Internal Program Error occurred.

Explanation

An internal program error was detected.

System action

Interrupts the processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag0206

SNMP error occurred on storage communication.

Explanation

An SNMP error occurred during communication between the storage and server.

System action

Interrupts the processing.

System administrator response

Check the LAN environment for problems.

When the target device is an ETERNUS disk array, the following environment settings may not be correct. For details, refer to "Chapter 4 Environment Configuration" in the ETERNUS SF Storage Cruiser User's Guide.

  • The network environment settings in the disk array (Check whether the network settings for communication with the Manager have been made.)

  • SNMP agent environment settings in the disk array

In some cases, the community name of a device such as an ETERNUS disk array, which uses the SNMP protocol for communication, may be set to something other than "public" and the community name of the admin server may not be changed.

If so, communication is disabled because of a mismatch of the community name. The community name of the target device needs to be set for the admin server.

Set the community name by referring to the "SNMP_COMMUNITY_NAME_FOR_IP" parameter provided in "C.2 sanma.conf Parameter" in the ETERNUS SF Storage Cruiser User's Guide, and reflect the contents of the setting file on this software.

swsag0207

Socket error occurred on storage communication.

Explanation

A socket error occurred during communication between the storage and server.

System action

Interrupts the processing.

System administrator response

Check the LAN environment for problems.

swsag0208

Selected storage is not found.

Explanation

The specified storage is not found.

System action

Interrupts the processing.

System administrator response

Check whether the specified storage is connected to the LAN.

When the target device is an ETERNUS disk array, the following environment settings may not be correct. For details, refer to "Chapter 4 Environment Configuration" in the ETERNUS SF Storage Cruiser User's Guide.

  • The network environment settings in the disk array (Check whether the network settings for communication with the Manager have been made.)

  • SNMP agent environment settings in the disk array

In some cases, the community name of a device such as an ETERNUS disk array, which uses the SNMP protocol for communication, may be set to something other than "public" and the community name of the admin server may not be changed. If so, communication is disabled because of a mismatch of the community name. The community name of the target device needs to be set for the admin server.

Set the community name by referring to the "SNMP_COMMUNITY_NAME_FOR_IP" parameter provided in "C.2 sanma.conf Parameter" in the ETERNUS SF Storage Cruiser User's Guide, and reflect the contents of the setting file on this software.

swsag0209

Network I/O Error on storage communication.

Explanation

An I/O error occurred during communication with the storage.

System action

Interrupts the processing.

System administrator response

Check the LAN environment for problems.

swsag0210

Timeout Error on storage communication.

Explanation

A time-out occurred during communication with the storage.

System action

Interrupts the processing.

System administrator response

Check the LAN environment for problems.

Poor and slow communications can cause a timeout when one communication mode is set to "Auto Negoiation" and the other is set to "Full (all dual)".

swsag0211

No response from storage.

Explanation

A required storage was not found.

System action

Interrupts the processing.

System administrator response

Check whether the specified storage is connected to the LAN.

When the target device is an ETERNUS disk array, the following environment settings may not be correct. For details, refer to "Chapter 4 Environment Configuration" in the ETERNUS SF Storage Cruiser User's Guide.

  • The network environment settings in the disk array (Check whether the network settings for communication with the Manager have been made.)

  • SNMP agent environment settings in the disk array

In some cases, the community name of a device such as an ETERNUS disk array, which uses the SNMP protocol for communication, may be set to something other than "public" and the community name of the admin server may not be changed. If so, communication is disabled because of a mismatch of the community name. The community name of the target device needs to be set for the admin server.

Set the community name by referring to the "SNMP_COMMUNITY_NAME_FOR_IP" parameter provided in "C.2 sanma.conf Parameter" in the ETERNUS SF Storage Cruiser User's Guide, and reflect the contents of the setting file on this software.

swsag0212

This device is not supported.

Explanation

Management of the specified IP device is not supported.

System action

Interrupts the processing.

System administrator response

Check whether the specified IP device is valid.

swsag0213

User ID for storage is incorrect.

Explanation

An attempt to login to the storage failed because the user ID was invalid.

System action

Interrupts the processing.

System administrator response

If this message is displayed for device registration, re-execute the processing and then enter a valid user ID.

If this message is displayed for a device that has already been registered, determine the relevant device from "Detail" and then turn off the device power. Select "Refresh" and then "Delete device". Then, execute "Equipment registration" again and enter a valid user ID and password.

swsag0214

Password for storage is incorrect.

Explanation

An attempt to login to the storage failed because the entered password was invalid.

System action

Interrupts the processing.

System administrator response

If this message is displayed for device registration, re-execute the processing and then enter a valid password.

If this message is displayed for a device that has already been registered, determine the relevant device from "Detail" and then turn off the device power. Select "Refresh" and then "Delete device". Then, execute "Equipment registration" again and then enter a valid password.

swsag0215

Another user is logged into the storage. Logout and run function again. login IP: %IP_ADDRESS

Explanation

The command issued from the Manager cannot be executed because another user has already logged into the storage.

Parameters

%IP_ADDRESS : Login source IP address. (For the GR720/GR730, the login user name is displayed after IP_ADDRESS. This may not be displayed depending on the type of the storage device.)

System action

Interrupts the processing.

System administrator response

Logout the process logged into the target device, and then re-execute it. If the user fails to explicitly log out from ETERNUSmgr/GRmgr after login, such as when the user terminates the Web server while logging into ETERNUSmgr/GRmgr, ETERNUSmgr/GRmgr remains logged in. In this case, login to ETERNUSmgr/GRmgr again and forcibly logout the invalid login process.

swsag0216

User lacks storage-setting authority.

Explanation

The user is not authorized to make settings for the storage.

System action

Interrupts the processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag0217

No root password is registered in storage.

Explanation

The root password is not set in the storage.

System action

Interrupts the processing.

System administrator response

Set the root password in the storage.

swsag0218

CGI access error occurred in storage communication.

Explanation

An error occurred during CGI access to the storage.

System action

Interrupts the processing.

System administrator response

Check the LAN status.

swsag0219

CGI internal command error occurred in storage communication.

Explanation

An error occurred during send of the CGI command to the storage.

System action

Interrupts the processing.

System administrator response

Check the LAN status.

swsag0220

Internal Program Error: (Added HBA WWPN for a HBA of Security MODE off)

Explanation

An internal program error was detected. (An attempt was made to register HBA WWPN in the CA for which the security function is invalid.)

System action

Interrupts the processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag0221

Internal Program Error: (Tried defining indefinable host affinity for storage)

Explanation

An internal program error was detected. (An attempt was made to set an access path for the storage for which AffinityGroup setting is disabled.)

System action

Interrupts the processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag0222

Internal Program Error: (No Affinity Group setting for device run with affinity group function.)

Explanation

An internal program error was detected. (An affinity group was not set for the device on which the affinity function is active.)

System action

Interrupts the processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag0223

CA has another affinity group definition for selected HBA.

Explanation

The CA selected for access path setting already has another affinity group definition for the relevant HBA.

Only one affinity group can be defined from one HBA.

System action

Interrupts the processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag0224

Selected affinity group not defined in storage

Explanation

The storage affinity group specified for access path setting is not defined in the storage device.

System action

Interrupts the processing.

System administrator response

Check whether a correct affinity group has been selected.

swsag0225

Internal Program Error: (Different Affinity Group selected)

Explanation

An internal program error was detected. (The zone assigned to the HBA to be deleted differs from the specified zone.)

System action

Interrupts the processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag0226

Internal Program Error: (Invalid CA Logical ID)

Explanation

An internal program error was detected. (An invalid CA ID was specified. )

System action

Interrupts the processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag0227

Registration of Host affinity HBA WWPN is full on storage CA.

Explanation

No more host affinity HBAs can be registered for the storage CA specified for access path setting because the registry is full.

System action

Interrupts the processing.

System administrator response

Delete any unnecessary access paths for the specified CA, or expand the size of the storage CA.

swsag0228

Registration of SNMP Trap address is full on storage.

Explanation

Another IP address cannot be set for the SNMP trap send destination on the storage side because the number of the registered IP addresses has reached the maximum.

System action

Interrupts the processing.

System administrator response

Delete any unnecessary SNMP trap send destination IP addresses from those defined in the storage. Use the appropriate storage tool to delete them.

swsag0229

Registration of SNMP Trap address area is full on storage.

Explanation

The SNMP trap setting area in the storage is full and no additional registration is permitted.

System action

Interrupts the processing.

System administrator response

Delete any unnecessary SNMP trap send destination IP addresses from those defined in the storage. Use the proper tool to delete them from storage.

swsag0230

CGI processing failed in storage communication. (Some storage settings made.)

Explanation

An error occurred during the CGI processing from the Manager to the storage.

System action

Interrupts the processing. The setting for the storage has not been changed.

System administrator response

Re-enter the command.

swsag0231

CGI processing failed in storage communication. (Some storage settings made.)

Explanation

An error occurred during the CGI processing from the Manager to the storage.

System action

Interrupts the processing. The setting for the storage is unclear.

System administrator response

Re-enter the command.

swsag0232

CGI processing failed in storage communication. (Some storage settings made.)

Explanation

An error occurred during the CGI processing from the Manager to the storage.

System action

Interrupts the processing. The setting for the storage has been partially changed.

System administrator response

Re-enter the command.

swsag0233

Incorrect Storage Configuration.

Explanation

A storage internal configuration information error was detected.

System action

Interrupts the processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag0235

Selected path is using by other application

Explanation

The diagnostic path is being used (open) by another application.

System action

Interrupts the processing.

System administrator response

Re-enter the command.

swsag0236

Administrative server detected error for selected path

Explanation

An error occurred during diagnosis of the selected path.

System action

Interrupts the processing.

System administrator response

Re-enter the command.

swsag0237

Manager cannot diagnose access path

Explanation

Path diagnosis cannot be executed.

System action

Interrupts the processing.

System administrator response

Re-enter the command.

swsag0238

Path error detected on server node.

Explanation

The Agent detected a path error.

System action

Interrupts the processing.

System administrator response

Re-enter the command.

swsag0239

Server node environment error detected. detail: [s1]

Explanation

An environment error was detected on the administrative server.

Parameters

s1 : Detail message output by the Agent

System action

Interrupts the processing.

System administrator response

Apply countermeasures as described in the detail message output by the Agent. For an explanation of the detail message, refer to "Chapter 2 Agent Messages".

swsag0240

Invalid information on server node. detail: [s1]

Explanation

Invalid information was detected on the administrative server.

Parameters

s1 : Detail message output by the Agent

System action

Interrupts the processing.

System administrator response

Apply countermeasures as described in the detail message output by the Agent. For an explanation of the detail message, refer to "Chapter 2 Agent Messages".

swsag0241

Invalid parameter at SNMP command is detected on server node. detail: [s1]

Explanation

An invalid value was detected during communication with the administrative server.

The operator made a specification mistake, or the LAN environment may have a problem.

Parameters

s1 : Detail message output by the Agent

System action

Interrupts the processing.

System administrator response

Apply countermeasures as described in the detail message output by the Agent. For an explanation of the detail message, refer to "Chapter 2 Agent Messages".

swsag0242

Invalid operation server node. detail: [s1]

Explanation

The Agent detected an operation error.

Parameters

s1 : Detail message output by the Agent

System action

Interrupts the processing.

System administrator response

Apply countermeasures as described in the detail message output by the Agent. For an explanation of the detail message, refer to "Chapter 2 Agent Messages".

swsag0243

System error occurred on server node. detail: [s1]

Explanation

A system error was detected.

Parameters

s1 : Detail message output by the Agent

System action

Interrupts the processing.

System administrator response

Apply countermeasures as described in the detail message output by the Agent. For an explanation of the detail message, refer to "Chapter 2 Agent Messages".

swsag0244

Internal Program Error occurred on server node.

Explanation

The Agent detected a program internal error.

System action

Interrupts the processing.

System administrator response

If the command for changing the IP address of SNMP Trap destination (sanadmsh chtraprcvip) is executed, check the argument and re-execute the command.

If the problem is not solved or other cases, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

swsag0245

Failed to update definition file. detail: [s1]

Explanation

The Agent failed to update the server node device and Fibre Channel environment definition files.

Parameters

s1 : Detail message output by the Agent

System action

Interrupts the processing.

System administrator response

Apply countermeasures as described in the detail message output by the Agent. For an explanation of the detail message, refer to "Chapter 2 Agent Messages".

swsag0246

Internal Program error occurred.

Explanation

An internal program error was detected.

System action

Interrupts the processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag0247

Timeout occurred to startup of snmp trap handler thread.

Explanation

A thread start time-out occurred when the SNMP trap handler was started.

System action

Interrupts the processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag0248

unable to find SNMP library.

Explanation

A library required for the SNMP trap handler was not detected.

System action

Interrupts the processing.

System administrator response

The SNMP library may not be installed normally. Check whether the library has been installed normally.

swsag0249

Unable to update zoning configuration, because current zoning configuration is inconsistent. The zoning configuration:

Explanation

The current zoning setting could not be updated because the current zoning setting contained an error.

System action

Interrupts the processing.

System administrator response

Check the zoning setting, and then re-execute.

swsag0250

Not supported switch/hub. The target device address: %IP_ADDRESS

Explanation

The relevant switch or hub is not supported.

Parameters

%IP_ADDRESS : Indicates the IP address of the device to be processed.

System action

Interrupts the processing.

System administrator response

Check whether the device with the relevant IP address is supported by this software. Also, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

swsag0251

The device does not support Beacon function,

Explanation

The specified device does not support the beacon function.

System action

None

System administrator response

None

swsag0252

The instance is already in DB of SANmgr.

Explanation

The specified device or instance already exists in the database.

System action

None

System administrator response

Check the device status or selection again.

swsag0253

The association of same kind device is already in DB of administrative server.

Explanation

The association for the same device type already exists in the database. For instance, HBA can have a physical line only with a single hub.

System action

Interrupts the processing.

System administrator response

Check the device status or selection again.

swsag0254

More than one device has a same IP address.

Explanation

Two or more devices have the same IP address.

System action

Interrupts the processing.

System administrator response

Check the IP address of each device.

swsag0255

More than one HBA/Storage FC Port has a same WWPN.

Explanation

Two or more HBA/Storage FC Ports have the same WWPN.

System action

Interrupts the processing.

System administrator response

Check the environment. Particularly, confirm the following.

  • Pay careful attention to the Agent configuration file in the Windows operating system. Some values may present a problem.

  • Turn back WWPN to before it changes, when the WWPN of Storage FC Port is changed by using the storage migration function.

  • When this message is output during detects the device in the subnet, there is a possibility that IP address on the Slave CM side is set with ETERNUS. Please correspond either as follows when IP address on the Slave CM side is set with ETERNUS.

    • Please execute "Detect device in subnet" again after invalidating IP address on the Slave CM side.

    • Please put into the state that the communication between the administrative server and Slave CM cannot be done, and execute "Detect device in subnet" again.

    • Do not perform "Detect device in subnet", please detect devices by "Detect by IP address".

swsag0256

The specified device is Manually Embedded Device.

Explanation

The specified device was set up using the manual embedding function.

This operation cannot be applied to a device that was set up using the manual embedding function.

System action

None

System administrator response

None

swsag0257

An Internal Program Error occurred: The specified device is Manually Embedded Device.

Explanation

An internal program error was detected. (The specified device was set up using the manual embedding function.)

This operation cannot be applied to a device that was set up using the manual embedding function.

System action

Interrupts the processing.

System administrator response

None

swsag0258

The specified device is not Manually Embedded Device.

Explanation

The specified device was not set up using the manual embedding function.

This operation cannot be applied to a device that was set up using the manual embedding function.

System action

Interrupts the processing.

System administrator response

None

swsag0259

An Internal Program Error occurred: The specified device is not Manually Embedded Device.

Explanation

An internal program error was detected. (The specified device was not set up using the manual embedding function.)

System action

Interrupts the processing.

System administrator response

None

swsag0260

An Internal Program Error occurred: The logical number of inputted HBA is null.

Explanation

An internal program error was detected. (The specified HBA logical number is invalid.)

System action

Interrupts the processing.

System administrator response

None

swsag0261

The cascaded hub group which the inputted Hub included already has one association to Switch.

Explanation

The FC rules permit only one Fibre Channel cable to be connected from a group of hubs that are cascaded with Fibre Channel cables to the switch. (Normally, only a single connection is permitted.)

System action

None

System administrator response

None

swsag0262

The specified FC Port type is not FC-AL.

Explanation

The type of the FC port specified for connection is not FC-AL. The FC port type must be FC-AL for connection between the hub and physical line.

System action

None

System administrator response

Check the FC port type.

Set the HBA and CA Fibre Channel port connection types to Loop connection (FC-AL type port). For information on how to set the ports, refer to the respective HBA driver manuals and the manuals for individual devices.

swsag0263

The kind of specified FC-Adaptor is changed. Need try again.

Explanation

The FC adapter type (HBA or CA) has been changed. Re-enter the command.

System action

None

System administrator response

Re-enter the command.

swsag0264

An Internal Program Error occurred: Bad combination for Manager association.

Explanation

An internal program error was detected. (An invalid device combination was specified.)

System action

Interrupts the processing.

System administrator response

Check the device combination.

swsag0265

An Internal Program Error occurred: Bad combination for administrative server association.

Explanation

An internal program error was detected. (An invalid device combination was specified.)

System action

Interrupts the processing.

System administrator response

Check the device combination.

swsag0266

An Internal Program Error occurred: Specified devices are same.

Explanation

An internal program error was detected. (An association cannot be set up between the same devices.)

System action

Interrupts the processing.

System administrator response

None

swsag0267

An Internal Program Error occurred: Specified devices are same.

Explanation

An internal program error was detected. (An association cannot be set up between the same devices.)

System action

Interrupts the processing.

System administrator response

None

swsag0268

The device observe status of the Bridge is not appropriate for the operation.

Explanation

The device monitoring status of the bridge is inappropriate for executing the specified operation.

System action

Interrupts the processing.

System administrator response

Make sure that the device monitoring status is normal, and then re-execute the processing.

For access path settings, refer to "D.4.7 Access path setting has failed" in the ETERNUS SF Storage Cruiser User's Guide.

swsag0269

The device observe status of the server node and the Bridge is not appropriate for the operation.

Explanation

The device monitoring statuses of the server node and bridge are inappropriate for executing the specified operation.

System action

Interrupts the processing.

System administrator response

Make sure that the device monitoring status is normal, and then re-execute the processing.

For access path settings, refer to "D.4.7 Access path setting has failed" in the ETERNUS SF Storage Cruiser User's Guide.

swsag0270

The device observe status of the HBA and the Bridge is not appropriate for the operation.

Explanation

The device monitoring statuses of the HBA and bridge are inappropriate for executing the specified operation.

System action

Interrupts the processing.

System administrator response

Make sure that the device monitoring status is normal, and then re-execute the processing.

For access path settings, refer to "D.4.7 Access path setting has failed" in the ETERNUS SF Storage Cruiser User's Guide.

swsag0271

The device observe status of the server node, HBA and the Bridge is not appropriate for the operation.

Explanation

The device monitoring statuses of the server node, HBA, and bridge are inappropriate for executing the specified operation.

System action

Interrupts the processing.

System administrator response

Make sure that the device monitoring status is normal, and then re-execute the processing.

For access path settings, refer to "D.4.7 Access path setting has failed" in the ETERNUS SF Storage Cruiser User's Guide.

swsag0272

The device observe status of the Bridge and the CA is not appropriate for the operation.

Explanation

The device monitoring statuses of the bridge and CA are inappropriate for executing the specified operation.

System action

Interrupts the processing.

System administrator response

Make sure that the device monitoring status is normal, and then re-execute the processing.

For access path settings, refer to "D.4.7 Access path setting has failed" in the ETERNUS SF Storage Cruiser User's Guide.

swsag0273

The device observe status of the server node, Bridge and the CA is not appropriate for the operation.

Explanation

The device monitoring statuses of the server node, bridge, and CA are inappropriate for executing the specified operation.

System action

Interrupts the processing.

System administrator response

Make sure that the device monitoring status is normal, and then re-execute the processing.

For access path settings, refer to "D.4.7 Access path setting has failed" in the ETERNUS SF Storage Cruiser User's Guide.

swsag0274

The device observe status of the HBA, Bridge and the CA is not appropriate for the operation.

Explanation

The device monitoring statuses of the HBA, bridge, and CA are inappropriate for executing the specified operation.

System action

Interrupts the processing.

System administrator response

Make sure that the device monitoring status is normal, and then re-execute the processing.

For access path settings, refer to "D.4.7 Access path setting has failed" in the ETERNUS SF Storage Cruiser User's Guide.

swsag0275

The device observe status of the server node, HBA, Bridge and the CA is not appropriate for the operation.

Explanation

The device monitoring statuses of the server node, HBA, bridge, and CA are inappropriate for executing the specified operation.

System action

Interrupts the processing.

System administrator response

Make sure that the device monitoring status is normal, and then re-execute the processing.

For access path settings, refer to "D.4.7 Access path setting has failed" in the ETERNUS SF Storage Cruiser User's Guide.

swsag0276

Could not find any accessible switch.

Explanation

No enabled switch is found. Check the device monitoring status.

System action

Interrupts the processing.

System administrator response

Make sure that the device monitoring status of the switch is normal and that the model name and the firmware version number are correct, and then re-execute the processing.

swsag0277

Could not find any accessible switch.

Explanation

No enabled switch is found. Check the device monitoring status.

System action

Interrupts the processing.

System administrator response

Make sure that the device monitoring status of the switch is normal and that the model name and the firmware version number are correct, and then re-execute the processing.

For access path settings, refer to "D.4.7 Access path setting has failed" in the ETERNUS SF Storage Cruiser User's Guide.

swsag0278

The FC Adaptor has some access-path(s), could not delete the device which has access-path.

Explanation

Device deletion cannot be continued because the FC adapter holds an access path.

System action

Interrupts the processing.

System administrator response

Delete the access path associated with the FC adapter, and then re-execute the processing.

swsag0279

Deleting the device finished. But stopping SNMP Trap function to administrative server failed.

Explanation

Device deletion has been executed. Send of the SNMP trap to the administrative server could not be stopped.

System action

None

System administrator response

If necessary, cancel the SNMP Trap send setting that has been manually specified for the device.

swsag0280

Internal Program Error occurred (The input value is not appropriate), or the device was already deleted by another Management Window.

Explanation

The specified device has already been deleted from another management screen, or a program internal error (abnormal input value) may have occurred.

System action

Interrupts the processing.

System administrator response

Check whether multiple clients were used and "Delete device" was executed from another client. Also, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

swsag0281

CGI access error occurred in storage communication. Please check that ETERNUSmgr or GRmgr or GR Service Console is working surely.

Explanation

An error occurred during the CGI processing from the Manager to the storage.

System action

Interrupts the processing. The setting for the storage is unclear.

System administrator response

Re-enter the command.

swsag0282

Agent version is incorrect.

Explanation

An error occurred during the CGI processing from the Manager to the storage.

System action

Interrupts the processing. The setting for the storage is unclear.

System administrator response

Re-enter the command.

swsag0283

HBA type is incorrect.

Explanation

An error occurred during CGI processing from the Manager to the storage.

System action

Interrupts the processing. The setting for the storage is unclear.

System administrator response

Re-enter the command.

swsag0284

As other operation of the same Manager is being executed to the storage, this operation could not be executed.

Explanation

As the storage is being logged in by other operation of the same Manager, the command cannot be executed.

System action

Interrupts the processing.

System administrator response

Re-execute on completion of other operation of the same Manager.

swsag0285

Invalid CA port was specified.

Explanation

The access path cannot be set to the specified CA.

System action

Interrupts the processing.

System administrator response

Confirm the adapter type of the CA port to set the access path.
The adapter type that can be set the access path is FCCA only.

swsag0300

Command processing for devices ended abnormally on detection of processing error (ERR_XXXX_NAME). 'EDIT_HBA_NAME' means checking device definition file (e.g. sd.conf/st.conf) and editing by manual if necessary is required. :

Explanation

Command processing was stopped because an error was detected during processing.

System action

Interrupts the processing after changing the access path settings for some devices.

System administrator response

It will edit, if the device definition files (sd.conf/st.conf etc.) relevant to HBA of a server node are checked and there is necessity.

Check the error information displayed in "Detail" and then re-enter the command.

swsag0301

Command processing for devices ended abnormally on detection of processing error (ERR_XXXX_NAME). Some devices' access path was modified (XXXX_NAME). Reboot of some devices are required to enable definition (if the device is server node and supports dynamic reconfiguration function, unnecessary) (REBOOT_XXXX_NAME). 'EDIT_HBA_NAME' means checking device definition file (e.g. sd.conf/st.conf) and editing by manual if necessary is required. :

Explanation

The processing could not be performed for the device because the status of a certain device was not normal.

System action

Interrupts the processing after changing the access path settings for some devices.

System administrator response

It will edit, if the device definition files (sd.conf/st.conf etc.) relevant to HBA of a server node are checked and there is necessity.

Check the error information displayed in "Detail", and then re-enter the command.

swsag0302

Some device processing was skipped (SKIP_XXXX_NAME). 'EDIT_HBA_NAME' means checking device definition file (e.g. sd.conf/st.conf) and editing by manual if necessary is required. :

Explanation

Completes the processing by skipping the access path setting for some devices.

System action

Command processing was stopped because an error was detected during processing.

System administrator response

It will edit, if the device definition files (sd.conf/st.conf etc.) relevant to HBA of a server node are checked and there is necessity.

Check the status of the storage (for which processing was skipped) indicated in "Detail", and then re-enter the command.

swsag0303

Some device processing was skipped (SKIP_XXXX_NAME). And some devices' access path were modified (XXXX_NAME). Reboot of some devices are required to enable definition (if the device is server node and supports dynamic reconfiguration function, unnecessary) (REBOOT_XXXX_NAME). 'EDIT_HBA_NAME' means checking device definition file (e.g. sd.conf/st.conf) and editing by manual if necessary is required. :

Explanation

Completes the processing by skipping access path setting for some devices.

System action

Command processing was stopped because an error was detected during processing.

System administrator response

It will edit, if the device definition files (sd.conf/st.conf etc.) relevant to HBA of a server node are checked and there is necessity.

Check the status of the storage (for which processing was skipped) indicated in "Detail", and then re-enter the command.

swsag0304

Command processing for devices ended abnormally on detection of processing error (ERR_XXXX_NAME). And some device processing was skipped (SKIP_XXXX_NAME). 'EDIT_HBA_NAME' means checking device definition file (e.g. sd.conf/st.conf) and editing by manual if necessary is required. :

Explanation

Errors were detected in the access path settings of several devices.

Also, the processing was skipped for a certain device because the device status was not normal.

System action

Command processing was stopped because an error was detected during processing.

System administrator response

It will edit, if the device definition files (sd.conf/st.conf etc.) relevant to HBA of a server node are checked and there is necessity.

Check the status of the storage for which processing was skipped and error information indicated in "Detail", and then re-enter the command.

swsag0305

Command processing for devices ended abnormally on detection of processing error (ERR_XXXX_NAME). And some device processing was skipped (SKIP_XXXX_NAME). And some devices' access path were modified (XXXX_NAME). Reboot of some devices are required to enable definition (REBOOT_XXXX_NAME). 'EDIT_HBA_NAME' means checking device definition file (e.g. sd.conf/st.conf) and editing by manual if necessary is required. :

Explanation

Errors were detected in the access path setting for several devices.

Also, the processing was skipped for a certain device because the device status was not normal.

System action

Command processing was stopped because an error was detected during processing.

System administrator response

It will edit, if the device definition files (sd.conf/st.conf etc.) relevant to HBA of a server node are checked and there is necessity.

Check the status of the storage (for which processing was skipped because of an error) indicated in "Detail", and then re-enter the command.

swsag0306

A problem was found in DB of administrative server. Some device's access path configuration was MODIFIED. Reboot device to make this configuration valid(if the device is server node and supports dynamic reconfiguration function, unnecessary). 'EDIT_HBA_NAME' means checking device definition file(e.g. sd.conf/st.conf) and editing by manual if necessary is required. :

Explanation

An inconsistency was detected in the database data. Also, the access path settings for several devices were changed. To validate the settings, the devices must be rebooted.

System action

Command processing was stopped because an error was detected during processing.

System administrator response

Contact your Fujitsu systems engineer.

swsag0307

Unable to delete zone for switch. This is because of port zoning possibly due to zone setting not being one-to-one. Zone setting: %ZONES

Explanation

The Manager can delete only a WWPN (World Wide Port Name) zone with one-to-one zone setting.

Parameters

%ZONES : Indicates the zone setting that could not be deleted.

System action

Interrupts the processing.

System administrator response

Login to the switch directly and then manually adjust the zone setting.

swsag0310

The specified switch is NO SECURITY state, it does not have any Zoning setting. All ports are accessible but it is low level security. The user setting is 'KEEP this state'. If you set the switch as 'Set WWPN Zoning', you can get higher security level when connection new Access Path. (Note: 'Set WWPN Zoning' may cause the problem of current Access Path). Please refer the user/operation manual for the problem of current Access Path, how to change the switch setting and details.

Explanation

The status of the specified switch is NO_SECURITY.

System action

None

System administrator response

Check the system security.

swsag0311

The specified switch is NO SECURITY state; it does not have any Zoning setting. All ports are accessible but it is low level security. The user setting is 'Set WWPN Zoning', so you can get higher security level when connection new Access Path. But 'Set WWPN Zoning' may cause the problem of current AccessPath, to avoid the problem, you can set the switch as 'KEEP this state'. Please refer the user/operation manual for the problem of current Access Path, how to change the switch setting and details.

Explanation

The status of the switch to be operated is NO_SECURITY.

System action

None

System administrator response

Check the system security.

swsag0312

The specified switch is NO SECURITY state, it does not have any Zoning setting. The user setting is 'Set WWPN Zoning'. Setting WWPN Zoning to the switch bring you higher security level, but it may cause the problem of current Access Path. Please refer the user/operation manual for the problem of current Access Path, how to change the switch setting and details. If you really want to continue to set WWPN Zoning, change the argument and Try again.

Explanation

The status of the switch to be operated is NO_SECURITY.

System action

None

System administrator response

Check the system security.

swsag0313

The specified switch is NO SECURITY state; it does not have any Zoning setting. Processing stopped because the user setting is 'KEEP this state'. If you change the switch setting to 'Set WWPN Zoning', you can get higher security level when connection new Access Path. (Note: 'Set WWPN Zoning' may case the problem of current Access Path). Please refer the user/operation manual for the problem of current Access Path, how to change the switch setting and details.

Explanation

The status of the switch to be operated is NO_SECURITY.

System action

None

System administrator response

Check the system security.

swsag0314

Input value is invalid. Deleting the UnknownFcPort is only supported with process level=0. An Internal Program inconsistency was detected.

Explanation

A device deletion request was issued with the access path deletion option to an UnknownFcPort device.

System action

None

System administrator response

None

swsag0315

An error occurred when processing WWPN Zoning to the switch. Error switch name (ERR_SWITCH_NAME), Skipped switch name (SKIP_SWITCH_NAME), Processed switch name (SWITCH_NAME):

Explanation

A problem was detected during the processing for the WWPN zoning of a switch

System action

None

System administrator response

None

swsag0316

The device observe status of server node should be 'TIMEOUT' for deleting MultiPath driver on Windows system.

Explanation

The device monitoring status of the server node must be "communication disabled" to enable deletion of the MultiPath driver under Windows system.

System action

None

System administrator response

Delete the access path with the server powered down

After access path deletion, start the server to execute "Recreation of MultiPath" from the GUI of the MultiPath driver. For "Recreation of MultiPath", refer to the manual for MultiPath driver.

swsag0317

The device observe status of server node should be 'TIMEOUT' for deleting MultiPath driver on Windows system. And one of HBA is also not appropriate for this operation.

Explanation

The device monitoring status of the server node must be "communication disabled" to enable deletion of the MultiPath driver under Windows system. The device monitoring status of HBA is also inappropriate.

System action

None

System administrator response

Delete the access path with the server powered down.

After access path deletion, start the server to execute "Recreation of MultiPath" from the GUI of the MultiPath driver. For "Recreation of MultiPath", refer to the manual for MultiPath driver.

swsag0318

The device observe status of server node should be 'TIMEOUT' for deleting MultiPath driver on Windows system. And one of Storage is also not appropriate for this operation.

Explanation

The device monitoring status of the server node must be "communication disabled" to enable deletion of the MultiPath driver under Windows system. The device monitoring status of the storage is also inappropriate.

System action

None

System administrator response

Delete the access path with the server powered down.

After access path deletion, start the server to execute "Recreation of MultiPath" from the GUI of the MultiPath driver. For "Recreation of MultiPath", refer to the manual for MultiPath driver.

swsag0319

The device observe status of server node should be 'TIMEOUT' for deleting MultiPath driver on Windows system. And one of Storage and HBA is also not appropriate for this operation.

Explanation

The device monitoring status of the server node must be "communication disabled" to enable deletion of the MultiPath driver under Windows system. The device monitoring statuses of the storage and HBA are also inappropriate.

System action

None

System administrator response

Delete the access path with the server powered down.

After access path deletion, start the server to execute "Recreation of MultiPath" from the GUI of the MultiPath driver. For "Recreation of MultiPath", refer to the manual for MultiPath driver.

swsag0320

The device observe status of server node should be 'TIMEOUT' for deleting MultiPath driver on Windows system. And one of CA is also not appropriate for this operation.

Explanation

The device monitoring status of the server node must be "communication disabled" to enable deletion of the MultiPath driver under Windows system. The device monitoring status of CA is also inappropriate.

System action

None

System administrator response

Delete the access path with the server powered down.

After access path deletion, start the server to execute "Recreation of MultiPath" from the GUI of the MultiPath driver. For "Recreation of MultiPath", refer to the manual for MultiPath driver.

swsag0321

The device observe status of server node should be 'TIMEOUT' for deleting MultiPath driver on Windows system. And one of HBA and CA is also not appropriate for this operation.

Explanation

The device monitoring status of the server node must be "communication disabled" to enable deletion of the MultiPath driver under Windows system. The device monitoring statuses of HBA and CA are also inappropriate.

System action

None

System administrator response

Delete the access path with the server powered down.

After access path deletion, start the server to execute "Recreation of MultiPath" from the GUI of the MultiPath driver. For "Recreation of MultiPath", refer to the manual for MultiPath driver.

swsag0322

The device observe status of server node should be 'TIMEOUT' for deleting MultiPath driver on Windows system. And one of Storage and CA is also not appropriate for this operation.

Explanation

The device monitoring status of the server node must be "communication disabled" to enable deletion of the MultiPath driver under Windows system. The device monitoring statuses of the storage and CA are also inappropriate.

System action

None

System administrator response

Delete the access path with the server powered down.

After access path deletion, start the server to execute "Recreation of MultiPath" from the GUI of the MultiPath driver. For "Recreation of MultiPath", refer to the manual for MultiPath driver.

swsag0323

The device observe status of server node should be 'TIMEOUT' for deleting MultiPath driver on Windows system. And one of Storage, CA and HBA is also not appropriate for this operation.

Explanation

The device monitoring status of the server node must be "communication disabled" to enable deletion of the MultiPath driver under Windows system. The device monitoring statuses of HBA, storage, and CA are also inappropriate.

System action

None

System administrator response

Delete the access path with the server powered down.

After access path deletion, start the server to execute "Recreation of MultiPath" from the GUI of the MultiPath driver. For "Recreation of MultiPath", refer to the manual for MultiPath driver.

swsag0324

The device observe status of server node should be 'TIMEOUT' for deleting MultiPath driver on Windows system. And one of Bridge is also not appropriate for this operation.

Explanation

The device monitoring status of the server node must be "communication disabled" to enable deletion of the MultiPath driver under Windows system. The device monitoring status of the bridge is also inappropriate.

System action

None

System administrator response

Delete the access path with the server powered down.

After access path deletion, start the server to execute "Recreation of MultiPath" from the GUI of the MultiPath driver. For "Recreation of MultiPath", refer to the manual for MultiPath driver.

swsag0325

The device observe status of server node should be 'TIMEOUT' for deleting MultiPath driver on Windows system. And one of Bridge and HBA is also not appropriate for this operation.

Explanation

The device monitoring status of the server node must be "communication disabled" to enable deletion of the MultiPath driver under Windows system. The device monitoring statuses of the bridge and HBA are also inappropriate.

System action

None

System administrator response

Delete the access path with the server powered down.

After access path deletion, start the server to execute "Recreation of MultiPath" from the GUI of the MultiPath driver. For "Recreation of MultiPath", refer to the manual for MultiPath driver.

swsag0326

The device observe status of server node should be 'TIMEOUT' for deleting MultiPath driver on Windows system. And one of Bridge and CA is also not appropriate for this operation.

Explanation

The device monitoring status of the server node must be "communication disabled" to enable deletion of the MultiPath driver under Windows system. The device monitoring statuses of the bridge and CA are also inappropriate.

System action

None

System administrator response

Delete the access path with the server powered down.

After access path deletion, start the server to execute "Recreation of MultiPath" from the GUI of the MultiPath driver. For "Recreation of MultiPath", refer to the manual for MultiPath driver.

swsag0327

The device observe status of server node should be 'TIMEOUT' for deleting MultiPath driver on Windows system. And one of Bridge, CA and HBA is also not appropriate for this operation.

Explanation

The device monitoring status of the server node must be "communication disabled" to enable deletion of the MultiPath driver under Windows system. The device monitoring statuses of the HBA, bridge, and CA are also inappropriate.

System action

None

System administrator response

Delete the access path with the server powered down.

After access path deletion, start the server to execute "Recreation of MultiPath" from the GUI of the MultiPath driver. For "Recreation of MultiPath", refer to the manual for MultiPath driver.

swsag0328

Processing stopped. PORT Zoning to the switch is not supported yet.

Explanation

Zoning processing in the PORT ZONING format was specified for the switch. The present Manager does not support PORT ZONING.

System action

None

System administrator response

None

swsag0329

The WWPN of source and destination is SAME. Command terminated.

Explanation

The move source WWPN matches the move destination WWPN. Processing was interrupted.

System action

None

System administrator response

None

swsag0330

The HBA WWPN of Host Affinity for Create already exists in another AffinityGroup, Please set or check Affinity setting by ETERNUSmgr or GRmgr or GR Service Console.

Explanation

The HBA WWPN for host affinity to be created has already been set for another affinity group. Use ETERNUSmgr/GRmgr or GR service console to set host affinity directly.

System action

None

System administrator response

Set host affinity directly.

swsag0331

Inputted device does not support Performance function for administrative server.

Explanation

The performance display function does not support the specified device.

System action

None

System administrator response

None

swsag0332

The device does not support Port Beacon function.

Explanation

The specified device does not support the port beacon function.

System action

None

System administrator response

None

swsag0333

An Internal Program Error occurred: IP address is required for Performance function.

Explanation

An internal program error was detected (IP address information is needed to execute the performance display function.).

System action

None

System administrator response

None

swsag0334

An Internal Program Error occurred: Enterprise code is required for Performance function.

Explanation

An internal program error was detected (ENTERPRISE CODE is needed to execute the performance display function.).

System action

None

System administrator response

None

swsag0335

An Internal Program Error occurred: Inputted LUN information is invalid.

Explanation

An internal program error was detected (LUN information is needed to execute the performance display function.).

System action

None

System administrator response

None

swsag0336

Source and Destination WWPN is same. Command processing is terminated.

Explanation

The inheritance source and destination WWPNs are the same. Processing was interrupted.

System action

None

System administrator response

None

swsag0337

The Fc-Port type of two FcPorts must be same.

Explanation

The port types of the two specified FC ports do not match. A connection cannot be set up.

System action

None

System administrator response

Change the port connection type settings according to the environment.

A port connected to the Fibre Channel switch needs to be set to Fabric connection (N-type port). Set individual ports according to the device type by referring to "Chapter 4 Environment Configuration" in the ETERNUS SF Storage Cruiser User's Guide.

For a port connected to a hub or ports not connected to a Fibre Channel switch, the connection type needs to be set to Loop connection (FC-AL type port). Set the ports by referring the respective driver manuals for HBA or the device manuals for the CA-type port.

swsag0338

The Fibre Channel cable is not physically connected via Switch. Connect Access Path in this case is not supported.

Explanation

When a Fibre Channel cable is not physically connected via a switch, an access path is not connected. (Normally, an access path need not be connected.)

System action

None

System administrator response

None

swsag0339

Manager could not set the SNMP Trap destination address of the device automatically. Please set following IP address as SNP Trap destination address by appropriate way.

Explanation

The SNMP trap send destination IP address of the specified device cannot be set. Set the IP address, which is displayed in an appropriate manner for the device, for the SNMP trap send destination.

System action

None

System administrator response

Set the IP address, which is displayed in an appropriate manner for the device, for the SNMP trap send destination.

swsag0340

New device was found, but auto-adding the device failed. %MESSAGE

Explanation

A new device was detected as the result of device search. However, a problem was detected during automatic device registration.

Parameters

%MESSAGE : Detail information on the problem detected during device registration

System action

Interrupts the processing.

System administrator response

Register the device again.

swsag0341

The operation for this OS kind or OS version of server node is not supported.

Explanation

This operation for the selected OS type or version number of server node

is not supported.

System action

Interrupts the processing.

System administrator response

None

swsag0342

CA's WWPN for HBA storage affinity is plurally saved. An appropriate process(e.g disks -C command) may be not done after Access Path processing on Solaris environment. Or an internal program error occurred.

Explanation

The specified WWPN for HBA storage affinity and the WWPN for a CA were found to be duplicate during the processing.

If the host node is a Solaris OS environment proper procedures (for example, commands such as "disks -C") may not have performed, or an internal program error may have occurred.

System action

Interrupts the processing.

System administrator response

If the host node is a Solaris OS environment, then check procedures such as access path definition. For details, refer to the "ETERNUS SF Storage Cruiser User's Guide", section "Operation" > "Access Path Management".

If the host node is not a Solaris OS environment or this issue is not solved after taking measures according to the paragraph above, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

swsag0343

The operation is not appropriate for this device.

Explanation

An instruction for an operation that is not supported on the specified device was issued.

System action

Interrupts the processing.

System administrator response

None

swsag0345

Unexpected error has occurred.

Explanation

An unexpected exception occurred.

System action

Interrupts the processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE)..

swsag0400

Network communication error occurred. The target device address:

Explanation

A network communication error occurred.

System action

Interrupts system processing.

System administrator response

Check the LAN environment for problems.

In some cases, the community name of a device such as fibre channel switch that uses the SNMP protocol for communication may be set to something other than "public" and the community name of the admin server may not be changed. If so, communication is disabled because of a mismatch of the community name. The community name of the target device needs to be set for the admin server.

Set the community name by referring to the "SNMP_COMMUNITY_NAME_FOR_IP" parameter provided in "C.2 sanma.conf Parameter" in the ETERNUS SF Storage Cruiser User's Guide, and reflect the contents of the setting file on this software.

If the problem persists even after checking the above environment settings, collect the data required for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag0401

Unable to find the device. The target device address:

Explanation

The specified device was not found.

System action

Interrupts system processing.

System administrator response

Check whether the entered IP address, the network settings of that device, and the settings required to manage that device are valid.

When the device to be detected is an ETERNUS disk array, the following environment settings may not be correct.

For details, refer to "Chapter 4 Environment Configuration" in the ETERNUS SF Storage Cruiser User's Guide.

  • The network environment settings in the disk array (Check whether the network settings for communication with the Manager have been made.)

  • SNMP agent environment settings in the disk array

In some cases, the community name of an ETERNUS disk array or a device such as fibre channel switch that uses the SNMP protocol for communication may be set to something other than "public" and the community name of the admin server may not be changed. If so, communication is disabled because of a mismatch of the community name. The community name of the target device needs to be set for the admin server.

Set the community name by referring to the "SNMP_COMMUNITY_NAME_FOR_IP" parameter provided in "C.2 sanma.conf Parameter" in the ETERNUS SF Storage Cruiser User's Guide, and reflect the contents of the setting file on this software.

swsag0402

Network I/O error occurred. The target device address:

Explanation

An I/O error occurred during network communication.

System action

Interrupts system processing.

System administrator response

Check the LAN environment for problems. Or, check the target device for problems.

In some cases, the community name of a device such as fibre channel switch that uses the SNMP protocol for communication may be set to something other than "public" and the community name of the admin server may not be changed. If so, communication is disabled because of a mismatch of the community name. The community name of the target device needs to be set for the admin server.

Set the community name by referring to the "SNMP_COMMUNITY_NAME_FOR_IP" parameter provided in "C.2 sanma.conf Parameter" in the ETERNUS SF Storage Cruiser User's Guide, and reflect the contents of the setting file on this software.

If the problem persists even after checking the above environment settings, collect the data required for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag0403

Timeout error occurred in communication with the device. The target device address:

Explanation

A time-out occurred during communication with the specified device.

System action

Interrupts system processing.

System administrator response

Check the LAN environment for problems. Alternatively, check the target device for problems.

In some cases, the community name of a device such as fibre channel switch that uses the SNMP protocol for communication may be set to something other than "public" and the community name of the admin server may not be changed. If so, communication is disabled because of a mismatch of the community name. The community name of the target device needs to be set for the admin server.

Set the community name by referring to the "SNMP_COMMUNITY_NAME_FOR_IP" parameter provided in "C.2 sanma.conf Parameter" in the ETERNUS SF Storage Cruiser User's Guide, and reflect the contents of the setting file on this software.

If the problem persists even after checking the above environment settings, collect the data required for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag0404

No response from the device. The target device address:

Explanation

No response was received from the specified device.

System action

Interrupts system processing.

System administrator response

Check the LAN environment for problems. Alternatively, check the target device for problems.

In some cases, the community name of a device such as fibre channel switch that uses the SNMP protocol for communication may be set to something other than "public" and the community name of the admin server may not be changed. If so, communication is disabled because of a mismatch of the community name. The community name of the target device needs to be set for the admin server.

Set the community name by referring to the "SNMP_COMMUNITY_NAME_FOR_IP" parameter provided in "C.2 sanma.conf Parameter" in the ETERNUS SF Storage Cruiser User's Guide, and reflect the contents of the setting file on this software.

If the problem persists even after checking the above environment settings, collect the data required for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag0405

SNMP protocol error occurred. The target device address:

Explanation

An SNMP protocol error occurred.

System action

Interrupts system processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag0406

Unrecovered SNMP error occurred. The target device address:

Explanation

An unrecoverable SNMP error occurred.

System action

Interrupts system processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag0407

The device is not a SAN manager server node agent. The target device address:

Explanation

A server node device was detected but is not an Agent.

System action

Interrupts system processing.

System administrator response

Check whether the IP address of the specified device is correct. If the detected server node device is an Agent, the Agent may not run normally on the server node. Alternatively, check the target device for problems.

swsag0408

Unable to find a GRSC managing the GR. The target GR address:

Explanation

A GR disk array unit managed by GRSC was detected but GRSC was not found.

System action

Interrupts system processing.

System administrator response

Check the LAN environment for problems. Alternatively, check the target device for problems.

swsag0409

Internal program error occurred.

Explanation

An internal program error was detected.

System action

Interrupts system processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag0410

The device is not supported by the administrative server. The target device address:

Explanation

The specified device is not supported.

System action

Interrupts system processing.

System administrator response

Check whether the IP address of the specified device is correct.

swsag0411

The FCMGMT-MIB Revision of the device is not supported by the administrative server. FCMGMT-MIB Revision:

Explanation

The FCMGMT-MIB revision of the specified device is not supported.

System action

Interrupts system processing.

System administrator response

Check whether the IP address of the specified device is correct.

swsag0412

The FCMGMT-MIB Unit Type of the device is not supported by the administrative server. FCMGMT-MIB Unit Type:

Explanation

The FCMGMT-MIB device type of the specified device is not supported.

System action

Interrupts system processing.

System administrator response

Check whether the IP address of the specified device is correct.

swsag0413

Unexpected interrupt occurred during processing. The target device address:

Explanation

An interrupt occurred during processing.

System action

Interrupts system processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag0414

Unexpected error occurred. The target device address:

Explanation

An unexpected error occurred.

System action

Interrupts system processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag0415

The physical connection between the specified devices is not supported.

Explanation

The physical connection between the specified devices(except between router devices and switch devices) is not supported.

System action

None

System administrator response

None

swsag0416

Plural physical connections between one router device and one switch device is not supported.

Explanation

Multiple physical connections between one router device and one switch device is not supported.

System action

None

System administrator response

None

swsag0420

The SNMPTrap transmission address for the specified device was not able to be chosen automatically: %IPAddress%

Explanation

During device registration, the automatic SNMP Trap destination address setting function attempted to select the SNMP Trap destination address, but it could not select an appropriate address for the specified device.

Parameters

%IPAddress% : IP address of the target device

System action

None.

System administrator response

The network settings of the management server may be incorrect.
Check the IP address, host name, and other various network settings of the management server.
If no network routing daemon (such as "routed") is used, verify that the default gateway setting is correct.
If the same error occurs even though the setting is correct, refer to "MANAGER_LAN_CARD_IP" in "C.2 sanma.conf Parameter" in the ETERNUS SF Storage Cruiser User's Guide, and set all IP addresses of the management server.

If the same error occurs even after taking the above measures, disable the automatic SNMP Trap destination address setting function, and add the device.

Note that the correct SNMP Trap destination address cannot be selected if the network address conversion such as the NAT function is performed. In such cases, disable the automatic SNMP Trap destination address setting function, and add the device.

When the automatic SNMP Trap destination address setting function is disabled, refer to the device manual, and manually specify an appropriate SNMP Trap destination address.

swsag0490

Command canceled.

Explanation

The command was canceled.

System action

The system closes the command.

System administrator response

None

swsag0491

syntax error. detail=%DETAIL

Explanation

The command syntax is invalid. 'usage' is displayed.

Parameters

%DETAIL : One of the following is displayed:

  • If the command was not specified:

    command is not specified.

  • If the specified command (value) is invalid:

    command[value] is invalid.

  • If the specified parameter is invalid:

    parameter is invalid.

  • If the specified option [value] is invalid:

    option[value] is invalid or duplicated.

  • If the value or format of the option [value] is invalid:

    [value] is invalid value or format.

System action

The system displays 'usage' and interrupts the processing.

System administrator response

The system administrator reviews the command syntax and and then re-executes the operation.

swsag0492

Unexpected error has occurred.

Explanation

An unexpected exception occurred.

System action

Interrupts the processing

System administrator response

Please remove the following causes. Afterwards, please operate it again.

  • Please start the Manager when the Manager has stopped.

  • Please log out when you log in the switch.

If this fails to solve the problem, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

swsag0501

Skipped processing storage, cause it is a Manually Embedded Device.

Explanation

Access path processing was not performed for the storage device or FC-CA adapter because the device was set up using the manual embedding function. Perform manual access path processing for the storage that has the host affinity function.

System action

The command is completed normally.

System administrator response

Perform manual access path processing for the storage that has the host affinity function.

swsag0502

Skipped processing server node, cause it is a Manually Embedded Device.

Explanation

Access path processing was not performed for the server node or FC-HBA adapter because the device was set up using the manual embedding function. Perform manual access path processing for the server node that has a storage affinity function such as HBA WWPN binding.

System action

The command is completed normally.

System administrator response

Perform manual access path processing for the server node that has a storage affinity function such as HBA WWPN binding.

swsag0503

Skipped processing server node and Storage, cause it is a Manually Embedded Device.

Explanation

Access path processing was not performed for the server node (or FC-HBA adapter) or storage device (or FC-CA adapter) because the devices were set up using the manual embedding function.

Perform manual access path processing for the storage that has the host affinity function. Perform manual access path processing for the server node that has a storage affinity function such as HBA WWPN binding.

System action

The command is completed normally.

System administrator response

Perform manual access path processing for the server node that has a storage affinity function such as HBA WWPN binding.

Perform manual access path processing for the storage that has the host affinity function.

swsag0504

Please modify HBA and driver configuration file (sd.conf/st.conf/etc...) manually for new devices. Then you can make device path of server node using server node device awareness method (e.g. server node reboot or dynamic reconfiguration function.).

Explanation

Changing of the access path definition for the combination of the specified FC-HBA and storage type is not supported. Set the server node access path manually. After the setting has been made, the target server node must be rebooted in reconfigure mode. (This is not necessary if the server node supports the dynamic reconfiguration function.)

System action

Partially completes the command.

System administrator response

Manually change the access path definition related to the specified FC-HBA and storage type.

Then, the target server node must be rebooted in reconfigure mode. (This is necessary only if the server node does not support the dynamic reconfiguration function.)

swsag0505

Skipped processing storage, cause it is a Manually Embedded Device. Please modify HBA and driver configuration file (sd.conf/st.conf/etc...) manually for new devices. Then you can make device path of server node using server node device awareness method (e.g. server node reboot or dynamic reconfiguration function.).

Explanation

Access path processing was not performed for the storage device or FC-CA adapter because the device was set up using the manual embedding function. Perform manual access path processing for the storage that has the host affinity function.

Changing of the access path definition for the combination of the specified FC-HBA and storage type is not supported. Set the server node access path manually.

After the server node access path definition is changed, the target server node must be rebooted in reconfigure mode (the server node need not be rebooted if the server node supports the dynamic reconfiguration function.).

System action

The command is completed normally.

System administrator response

Manually change the access path definition related to the specified FC-HBA and storage type.

Perform manual access path processing for the storage that has the host affinity function.

Then, the target server node must be rebooted in reconfigure mode. (This is necessary only if the server node does not support the dynamic reconfiguration function.)

swsag0506

Access path was defined normally for storage. You can make device path of server node (Manually Embedded server node) using server node device awareness method (e.g. server node reboot or dynamic reconfigure function.) after the reboot of selected storage. Skipped processing server node, cause it is a Manually Embedded Device.

Explanation

A host affinity operation was performed for the storage.

Access path processing was not performed for the server node or FC-HBA adapter because the device was set up using the manual embedding function.

Perform manual access path processing for the server node that has a storage affinity function such as HBA WWPN binding.

Restart the storage to enable the storage settings, and then reboot the server node in reconfigure mode to reconfigure the device special file. The server node need not be rebooted, however, if it supports the dynamic reconfiguration function.

System action

The command is completed normally.

System administrator response

Perform manual access path processing for the server node that has a storage affinity function such as HBA WWPN binding.

Restart the storage to enable the storage settings, and then reboot the server node in reconfigure mode to reconfigure the device special file. The server node need not be rebooted, however, if it supports the dynamic reconfiguration function.

swsag0507

Access path was defined normally for storage. Please modify HBA and driver configuration file (sd.conf/st.conf/etc...) manually for new devices. After the reboot of selected storage, you can make device path of server node using server node device awareness method (e.g. server node reboot or dynamic reconfiguration function.).

Explanation

A host affinity operation was performed for the storage.

Changing of the access path definition for the combination of the specified FC-HBA and storage type is not supported.

Set the server node access path manually.

Restart the storage to enable the storage settings, and then reboot the server node in reconfigure mode to reconfigure the device special file. The server node need not be rebooted, however, if it supports the dynamic reconfiguration function.

System action

Partially completes the command.

System administrator response

Manually change the access path definition related to the specified FC-HBA and storage type.

Restart the storage to enable the storage settings, and then reboot the server node in reconfigure mode to reconfigure the device special file. The server node need not be rebooted, however, if it supports the dynamic reconfiguration function.

swsag0508

Skipped processing server node, cause it is a Manually Embedded Device.

Explanation

Access path processing was not performed for the server node or FC-HBA adapter because the device was set up using the manual embedding function. Perform manual access path processing for the server node that has a storage affinity function such as HBA WWPN binding.

System action

The command is completed normally.

System administrator response

Perform manual access path processing for the server node that has a storage affinity function such as HBA WWPN binding.

swsag0509

Please modify HBA and driver configuration file (sd.conf/st.conf/etc...) manually for new devices. Then you can make device path of server node using server node device awareness method (e.g. server node reboot or dynamic reconfiguration function.).

Explanation

Changing of the access path definition for the combination of the specified FC-HBA and storage type is not supported. Set the server node access path manually. After this setting has been made, the target server node must be rebooted in reconfigure mode (not needed if the server node supports the dynamic reconfiguration function.).

System action

Completes the commands partially.

System administrator response

Manually change the access path definition related to the specified FC-HBA and storage type.

Then, the target server node must be rebooted in reconfigure mode. (This is necessary only if the server node does not support the dynamic reconfiguration function.)

swsag0510

Access path was defined normally for storage. You can make device path of server node using server node device awareness method (e.g. server node reboot or dynamic reconfiguration function.).

Explanation

A host affinity operation was performed for the storage. The server node must be rebooted in reconfigure mode to reconfigure the server node special file. The server node need not be rebooted, however, if it supports the dynamic reconfiguration function.

System action

The command is completed normally.

System administrator response

Reboot the server node in reconfigure mode. (This is necessary only if the server node does not support the dynamic reconfiguration function.)

swsag0511

Access path was defined normally for storage. You can make device path of server node (Manually Embedded server node) using server node device awareness method (e.g. server node reboot or dynamic reconfigure function.). Skipped processing server node, cause it is a Manually Embedded Device.

Explanation

A host affinity operation was performed for the storage.

Access path processing was not performed for the server node or FC-HBA adapter because the device was set up using the manual embedding function. Perform manual access path processing for the server node that has a storage affinity function such as HBA WWPN binding.

Next, the server node must be rebooted in reconfigure mode to reconfigure the device special file. The server node need not be rebooted, however, if it supports the dynamic reconfiguration function.

System action

Partially completes the command.

System administrator response

Perform manual access path processing for the server node that has a storage affinity function such as HBA WWPN binding.

Next, the server node must be rebooted in reconfigure mode to reconfigure the device special file. The server node need not be rebooted, however, if it supports the dynamic reconfiguration function.

swsag0512

Access path was defined normally for storage. Please modify HBA and driver configuration file (sd.conf/st.conf/etc...) manually for new devices. Then you can make device path of server node using server node device awareness method (e.g. server node reboot or dynamic reconfiguration function.).

Explanation

A host affinity operation was performed for the storage.

Changing of the access path definition for the combination of the specified FC-HBA and storage type is not supported.

Set the server node access path manually.

Next, the server node must be rebooted in reconfigure mode to reconfigure the device special file. The server node need not be rebooted, however, if it supports the dynamic reconfiguration function.

System action

Completes the command partially.

System administrator response

Manually change the access path definition related to the specified FC-HBA and storage type.

Next, the server node must be rebooted in reconfigure mode to reconfigure the device special file. The server node need not be rebooted, however, if it supports the dynamic reconfiguration function.

swsag0513

Access path was defined normally for switch. You can make device path of server node using server node device awareness method (e.g. server node reboot or dynamic reconfiguration function.). Skipped processing storage, cause it is a Manually Embedded Device.

Explanation

Zoning was set for the switch.

Access path processing was not performed for the storage device or FC-CA adapter because the device was set up using the manual embedding function. Perform manual access path processing for the storage that has the host affinity function.

After this setting has been made, the target server node must be rebooted in reconfigure mode (not needed if the server node supports the dynamic reconfiguration function.).

System action

The command is completed normally.

System administrator response

Perform manual access path processing for the storage that has the host affinity function.

Next, the server node must be rebooted in reconfigure mode to reconfigure the device special file. The server node need not be rebooted, however, if it supports the dynamic reconfiguration function.

swsag0514

Access path was defined normally for switch. You can make device path of server node (Manually Embedded server node) using server node device awareness method (e.g. server node reboot or dynamic reconfigure function.). Skipped processing server node, cause it is a Manually Embedded Device.

Explanation

Zoning was set for the switch.

Access path processing was not performed for the server node or FC-HBA adapter because the device was set up using the manual embedding function. Perform manual access path processing for the server node that has a storage affinity function such as HBA WWPN binding.

Next, the server node must be rebooted in reconfigure mode to reconfigure the device special file. The server node need not be rebooted, however, if it supports the dynamic reconfiguration function.

System action

The command is completed normally.

System administrator response

Perform manual access path processing for the server node that has a storage affinity function such as HBA WWPN binding.

Next, the server node must be rebooted in reconfigure mode to reconfigure the device special file. The server node need not be rebooted, however, if it supports the dynamic reconfiguration function.

swsag0515

Access path was defined normally for switch. You can make device path of server node (Manually Embedded server node) using server node device awareness method (e.g. server node reboot or dynamic reconfigure function.). Skipped processing server node and Storage, cause it is a Manually Embedded Device.

Explanation

Zoning was set for the switch.

Access path processing was not performed for the server node (or FC-HBA adapter) and storage device (or FC-CA adapter) because the devices were set up using the manual embedding function.

Perform manual access path processing for the server node that has a storage affinity function such as HBA WWPN binding. Perform manual access path processing for the storage that has the host affinity function.

Next, the server node must be rebooted in reconfigure mode to reconfigure the device special file. The server node need not be rebooted, however, if it supports the dynamic reconfiguration function.

System action

The command is completed normally.

System administrator response

Perform manual access path processing for the server node that has a storage affinity function such as HBA WWPN binding.

Perform manual access path processing for the storage that has the host affinity function.

Next, the server node must be rebooted in reconfigure mode to reconfigure the device special file. The server node need not be rebooted, however, if it supports the dynamic reconfiguration function.

swsag0516

Access path was defined normally for switch. Please modify HBA and driver configuration file (sd.conf/st.conf/etc...) manually for new devices. Then you can make device path of server node using server node device awareness method (e.g. server node reboot or dynamic reconfiguration function.).

Explanation

Zoning was set for the switch.

Changing of the access path definition for the combination of the specified FC-HBA and storage type is not supported. Set the server node access path manually.

After this setting has been made, the target server node must be rebooted in reconfigure mode (not needed if the server node supports the dynamic reconfiguration function.).

System action

The command is completed normally.

System administrator response

Manually change the access path definition related to the specified FC-HBA and storage type.

Next, to reconfigure the device special file, the target server node must be rebooted in reconfigure mode. The server node need not be rebooted, however, if it supports the dynamic reconfiguration function.

swsag0517

Access path was defined normally for switch. Skipped processing storage, cause it is a Manually Embedded Device. Please modify HBA and driver configuration file (sd.conf/st.conf/etc...) manually for new devices. Then you can make device path of server node using server node device awareness method (e.g. server node reboot or dynamic reconfiguration function.).

Explanation

Zoning was set for the switch.

Access path processing was not performed for the storage device or FC-CA adapter because the device was set up using the manual embedding function. Perform manual access path processing for the storage that has the host affinity function.

Changing of the access path definition for the combination of the specified FC-HBA and storage type is not supported. Set the server node access path manually.

After this setting has been made, the target server node must be rebooted in reconfigure mode (not needed if the server node supports the dynamic reconfiguration function.).

System action

The command is completed normally.

System administrator response

Manually change the access path definition related to the specified FC-HBA and storage type.

Perform manual access path processing for the storage that has the host affinity function.

Next, to reconfigure the device special file, the target server node must be rebooted in reconfigure mode. The server node need not be rebooted, however, if it supports the dynamic reconfiguration function.

swsag0518

Access path was defined normally for switch and storage. You can make device path of server node (Manually Embedded server node) using server node device awareness method (e.g. server node reboot or dynamic reconfigure function.) after the reboot of selected storage. Skipped processing server node, cause it is a Manually Embedded Device.

Explanation

Zoning was set for the switch to define the access path. A host affinity operation was performed for the storage.

Access path processing was not performed for the server node or FC-HBA adapter because the device was set up using the manual embedding function.

Perform manual access path processing for the server node that has a storage affinity function such as HBA WWPN binding.

Restart the storage to enable the storage settings, and then reboot the server node in reconfigure mode to reconfigure the device special file. The server node need not be rebooted, however, if it supports the dynamic reconfiguration function.

System action

The command is completed normally.

System administrator response

Manually change the access path definition related to the specified FC-HBA and storage type.

Restart the storage to enable the storage settings, and then reboot the server node in reconfigure mode to reconfigure the device special file. The server node need not be rebooted, however, if it supports the dynamic reconfiguration function.

swsag0519

Access path was defined normally for switch and storage. Please modify HBA and driver configuration file (sd.conf/st.conf/etc...) manually for new devices. And after the reboot of selected storage, you can make device path of server node using server node device awareness method (e.g. server node reboot or dynamic reconfiguration function.).

Explanation

Zoning was set for the switch to define the access path. A host affinity operation was performed for the storage.

Changing of the access path definition for the combination of the specified FC-HBA and storage type is not supported. Set the server node access path manually.

Restart the storage to enable the storage settings, and then reboot the server node in reconfigure mode to reconfigure the device special file. The server node need not be rebooted, however, if it supports the dynamic reconfiguration function.

System action

The command is completed normally.

System administrator response

Manually change the access path definition related to the specified FC-HBA and storage type.

Restart the storage to enable the storage settings, and then reboot the server node in reconfigure mode to reconfigure the device special file. The server node need not be rebooted, however, if it supports the dynamic reconfiguration function.

swsag0520

Access path was defined normally for switch. You can make device path of server node using server node device awareness method (e.g. server node reboot or dynamic reconfiguration function.).

Explanation

Zoning was set for the switch to define the access path.

System action

The command is completed normally.

System administrator response

The target server node must be rebooted in reconfigure mode to enable the access path settings. (This is necessary only if the server node does not support the dynamic reconfiguration function.)

swsag0521

Access path was defined normally for switch. You can make device path of server node (Manually Embedded server node) using server node device awareness method (e.g. server node reboot or dynamic reconfigure function.). Skipped processing server node, cause it is a Manually Embedded Device.

Explanation

Zoning was set for the switch.

Access path processing was not performed for the server node or FC-HBA adapter because the device was set up using the manual embedding function. Perform manual access path processing for the server node that has a storage affinity function such as HBA WWPN binding.

Next, the server node must be rebooted in reconfigure mode to reconfigure the device special file. The server node need not be rebooted, however, if it supports the dynamic reconfiguration function.

System action

The command is completed normally.

System administrator response

Perform manual access path processing for the server node that has a storage affinity function such as HBA WWPN binding.

Next, the server node must be rebooted in reconfigure mode to reconfigure the device special file. The server node need not be rebooted, however, if it supports the dynamic reconfiguration function.

swsag0522

Access path was defined normally for switch. Please modify HBA and driver configuration file (sd.conf/st.conf/etc...) manually for new devices. Then you can make device path of server node using server node device awareness method (e.g. server node reboot or dynamic reconfiguration function.).

Explanation

Zoning was set for the switch.

Changing of the access path definition for the combination of the specified FC-HBA and storage type is not supported. Set the server node access path manually.

After this setting has been made, the target server node must be rebooted in reconfigure mode (not needed if the server node supports the dynamic reconfiguration function.).

System action

The command is completed normally.

System administrator response

Manually change the access path definition related to the specified FC-HBA and storage type.

Next, to reconfigure the device special file, the target server node must be rebooted in reconfigure mode. The server node need not be rebooted, however, if it supports the dynamic reconfiguration function.

swsag0523

Access path was defined normally for switch and storage. You can make device path of server node using server node device awareness method (e.g. server node reboot or dynamic reconfiguration function.).

Explanation

To define the access path, zoning was set for the switch and host affinity was set for the storage.

System action

The command is completed normally.

System administrator response

The target server node must be rebooted in reconfigure mode to enable access path setting. (This is necessary only if the server node does not support the dynamic reconfiguration function.)

swsag0524

Access path was defined normally for switch and storage. You can make device path of server node (Manually Embedded server node) using server node device awareness method (e.g. server node reboot or dynamic reconfigure function.). Skipped processing server node, cause it is a Manually Embedded Device.

Explanation

To define the access path, zoning was set for the switch and host affinity was set for the storage.

Access path processing was not performed for the server node or FC-HBA adapter because the device was set up using the manual embedding function. Perform manual access path processing for the server node that has a storage affinity function such as HBA WWPN binding.

After this setting has been made, the target server node must be rebooted in reconfigure mode. (This is not necessary if the server node supports the dynamic reconfiguration function.).

System action

The command is completed normally.

System administrator response

Perform manual access path processing for the server node that has a storage affinity function such as HBA WWPN binding.

The target server node must be rebooted in reconfigure mode to enable access path setting. (This is necessary only if the server node does not support the dynamic reconfiguration function.)

swsag0525

Access path was defined normally for switch and storage. Please modify HBA and driver configuration file (sd.conf/st.conf/etc...) manually for new devices. Then you can make device path of server node using server node device awareness method (e.g. server node reboot or dynamic reconfiguration function.).

Explanation

To define the access path, zoning was set for the switch and host affinity was set for the storage.

Changing of the access path definition for the combination of the specified FC-HBA and storage type is not supported. Set the server node access path manually.

After this setting has been made, the target server node must be rebooted in reconfigure mode. (This is not necessary if the server node supports the dynamic reconfiguration function.).

System action

The command is completed normally.

System administrator response

Manually change the access path definition related to the specified FC-HBA and storage type.

The target server node must be rebooted in reconfigure mode to enable access path setting. (This is necessary only if the server node does not support the dynamic reconfiguration function.)

swsag0526

Could not find any accessible switch. Processing with switch was skipped.

Explanation

An attempt was made to search for a switch that can be used for access path definition but none was found.

This error occurs if no switch is registered or if the switch status is abnormal.

System action

Partially completes the command.

System administrator response

Check the switch between the specified FC ports. If no switch is present or if none is registered, no action is required.

If the device status of each switch is abnormal, wait until the device statuses become normal and then re-enter the command.

swsag0527

Skipped processing storage, cause it is a Manually Embedded Device. Could not find any accessible switch. Processing with switch was skipped.

Explanation

Access path processing was not performed for the storage device or FC-CA adapter because the device was set up using the manual embedding function. Perform manual access path processing for the storage that has the host affinity function.

An attempt was made to search for a switch that can be used for access path definition but none was found.

This problem occurs if the switch version is not supported, if no switch is registered, or if the device status of the switch is abnormal.

System action

Partially completes the command.

System administrator response

Perform manual access path processing for storage that has the host affinity function.

Check the switch between the specified FC ports. If no switch is present or if none is registered, no action is required.

If the device status of each switch is abnormal, wait until the device statuses become normal and then re-enter the command. If the switch version is not supported, operate the switch directly.

swsag0528

Skipped processing server node, cause it is a Manually Embedded Device. Could not find any accessible switch. Processing with switch was skipped.

Explanation

Access path processing was not performed for the server node or FC-HBA adapter because the device was set up using the manual embedding function. Perform manual access path processing for the server node that has a storage affinity function such as HBA WWPN binding.

An attempt was made to search for a switch that can be used for access path definition but none was found.

This problem occurs if the switch version is not supported, if no switch is registered, or if the device status of the switch is abnormal.

System action

Partially completes the command.

System administrator response

Perform manual access path processing for the server node that has a storage affinity function such as HBA WWPN binding.

Check the switch between the specified FC ports. If no switch is present or if none is registered, no action is required.

If the device status of each switch is abnormal, wait until the device statuses become normal and then re-enter the command. If the switch version is not supported, operate the switch directly.

swsag0529

Skipped processing server node and Storage, cause it is a Manually Embedded Device. Could not find any accessible switch. Processing with switch was skipped.

Explanation

Access path processing was not performed for the server node (or FC-HBA) and storage device (or FC-CA adapter) because the devices were set up using the manual embedding function.

Perform manual access path processing for the storage that has the host affinity function. Perform manual access path processing for the server node that has a storage affinity function such as HBA WWPN binding.

An attempt was made to search for a switch that can be used for access path definition but none was found.

This problem occurs if the switch version is not supported, if no switch is registered, or if the device status of the switch is abnormal.

System action

Partially completes the command.

System administrator response

Perform manual access path processing for the server node that has a storage affinity function such as HBA WWPN binding.

Perform manual access path processing for the storage that has the host affinity function.

Check the switch between the specified FC ports. If no switch is present or if none is registered, no action is required.

If the device status of each switch is abnormal, wait until the device statuses become normal and then re-enter the command. If the switch version is not supported, operate the switch directly.

swsag0530

Please modify HBA and driver configuration file (sd.conf/st.conf/etc...) manually for new devices. Then you can make device path of server node using server node device awareness method (e.g. server node reboot or dynamic reconfiguration function.). Could not find any accessible switch. Processing with switch was skipped.

Explanation

Changing of the access path definition for the combination of the specified FC-HBA and storage type is not supported. Set the server node access path manually. After this setting has been made, the target server node must be rebooted in reconfigure mode. (This is not necessary if the server node supports the dynamic reconfiguration function.).

An attempt was made to search for a switch that can be used for access path definition but none was found.

This problem occurs if the switch version is not supported, if no switch is registered, or if the device status of the switch is abnormal.

System action

Partially completes the command.

System administrator response

Manually change the access path definition related to the specified FC-HBA and storage type.

Then, the target server node must be rebooted in reconfigure mode. (This is necessary only if the server node does not support the dynamic reconfiguration function.)

Check the switch between the specified FC ports. If no switch is present or if none is registered, no action is required.

If the device status of each switch is abnormal, wait until the device statuses become normal and then re-enter the command. If the switch version is not supported, operate the switch directly.

swsag0531

Skipped processing storage, cause it is a Manually Embedded Device. Please modify HBA and driver configuration file (sd.conf/st.conf/etc...) manually for new devices. Then you can make device path of server node using server node device awareness method (e.g. server node reboot or dynamic reconfiguration function.). Could not find any accessible switch. Processing with switch was skipped.

Explanation

Access path processing was not performed for the storage device or FC-CA adapter because the device was set up using the manual embedding function. Perform manual access path processing for the storage that has the host affinity function.

Changing of the access path definition for the combination of the specified FC-HBA and storage type is not supported. Set the server node access path manually.

After the server node access path definition is changed, the target server node must be rebooted in reconfigure mode (the server node need not be rebooted if the server node supports the dynamic reconfiguration function.).

An attempt was made to search for a switch that can be used for access path definition but none was found.

This problem occurs if the switch version is not supported, if no switch is registered, or if the device status of the switch is abnormal.

System action

Partially completes the command.

System administrator response

Manually change the access path definition related to the specified FC-HBA and storage type.

Perform manual access path processing for the storage that has the host affinity function.

Then, the target server node must be rebooted in reconfigure mode. (This is necessary only if the server node does not support the dynamic reconfiguration function.)

Check the switch between the specified FC ports. If no switch is present or if none is registered, no action is required.

If the device status of each switch is abnormal, wait until the device statuses become normal and then re-enter the command. If the switch version is not supported, operate the switch directly.

swsag0532

Access path was defined normally for storage. You can make device path of server node using server node device awareness method (e.g. server node reboot or dynamic reconfiguration function.) after the reboot of selected storage. Could not find any accessible switch. Processing with switch was skipped.

Explanation

A host affinity operation was performed for the storage.

Restart the storage to enable the storage settings, and then reboot the server node in reconfigure mode to reconfigure the device special file. The server node need not be rebooted, however, if it supports the dynamic reconfiguration function.

An attempt was made to search for a switch that can be used for access path definition but none was found.

This problem occurs if the switch version is not supported, if no switch is registered, or if the device status of the switch is abnormal.

System action

Partially completes the command.

System administrator response

Perform manual access path processing for the server node that has a storage affinity function such as HBA WWPN binding.

Restart the storage to enable the storage settings, and then reboot the server node in reconfigure mode to reconfigure the device special file. The server node need not be rebooted, however, if it supports the dynamic reconfiguration function.

Check the switch between the specified FC ports. If no switch is present or if none is registered, no action is required.

If the device status of each switch is abnormal, wait until the device statuses become normal and then re-enter the command. If the switch version is not supported, operate the switch directly.

swsag0533

Access path was defined normally for storage. You can make device path of server node (Manually Embedded server node) using server node device awareness method (e.g. server node reboot or dynamic reconfigure function.) after the reboot of selected storage. Skipped processing server node, cause it is a Manually Embedded Device. Could not find any accessible switch. Processing with switch was skipped.

Explanation

A host affinity operation was performed for the storage.

Access path processing was not performed for the server node or FC-HBA adapter because the device was set up using the manual embedding function.

Perform manual access path processing for the server node that has a storage affinity function such as HBA WWPN binding.

Restart the storage to enable the storage settings, and then reboot the server node in reconfigure mode to reconfigure the device special file. The server node need not be rebooted, however, if it supports the dynamic reconfiguration function.

An attempt was made to search for a switch that can be used for access path definition but none was found.

This problem occurs if the switch version is not supported, if no switch is registered, or if the device status of the switch is abnormal.

System action

Partially completes the command.

System administrator response

Perform manual access path processing for the server node that has a storage affinity function such as HBA WWPN binding.

Restart the storage to enable the storage settings, and then reboot the server node in reconfigure mode to reconfigure the device special file. The server node need not be rebooted, however, if it supports the dynamic reconfiguration function.

Check the switch between the specified FC ports. If no switch is present or if none is registered, no action is required.

If the device status of each switch is abnormal, wait until the device statuses become normal and then re-enter the command. If the switch version is not supported, operate the switch directly.

swsag0534

Access path was defined normally for storage. Please modify HBA and driver configuration file (sd.conf/st.conf/etc...) manually for new devices. And after the reboot of selected storage, you can make device path of server node using server node device awareness method (e.g. server node reboot or dynamic reconfiguration function.). Could not find any accessible switch. Processing with switch was skipped.

Explanation

A host affinity operation was performed for the storage.

Changing of the access path definition for the combination of the specified FC-HBA and storage type is not supported.

Set the server node access path manually.

Restart the storage to enable the storage settings, and then reboot the server node in reconfigure mode to reconfigure the device special file. The server node need not be rebooted, however, if it supports the dynamic reconfiguration function.

An attempt was made to search for a switch that can be used for access path definition but none was found.

This problem occurs if the switch version is not supported, if no switch is registered, or if the device status of the switch is abnormal.

System action

Partially completes the command.

System administrator response

Manually change the access path definition related to the specified FC-HBA and storage type.

Restart the storage to enable the storage settings, and then reboot the server node in reconfigure mode to reconfigure the device special file. The server node need not be rebooted, however, if it supports the dynamic reconfiguration function.

Check the switch between the specified FC ports. If no switch is present or if none is registered, no action is required.

If the device status of each switch is abnormal, wait until the device statuses become normal and then re-enter the command. If the switch version is not supported, operate the switch directly.

swsag0535

Could not find any accessible switch. Processing with switch was skipped.

Explanation

An attempt was made to search for a switch that can be used for access path definition but none was found.

This problem occurs if the switch version is not supported, if no switch is registered, or if the device status of the switch is abnormal.

System action

Partially completes the command.

System administrator response

Check the switch between the specified FC ports. If no switch is present or if none is registered, no action is required.

If the device status of each switch is abnormal, wait until the device statuses become normal and then re-enter the command. If the switch version is not supported, operate the switch directly.

swsag0536

Skipped processing server node, cause it is a Manually Embedded Device. Could not find any accessible switch. Processing with switch was skipped.

Explanation

Access path processing was not performed for the server node or FC-HBA adapter because the device was set up using the manual embedding function. Perform manual access path processing for the server node that has a storage affinity function such as HBA WWPN binding.

An attempt was made to search for a switch that can be used for access path definition but none was found.

This problem occurs if the switch version is not supported, if no switch is registered, or if the device status of the switch is abnormal.

System action

The command is completed normally.

System administrator response

Perform manual access path processing for the server node that has a storage affinity function such as HBA WWPN binding.

Check the switch between the specified FC ports. If no switch is present or if none is registered, no action is required.

If the device status of each switch is abnormal, wait until the device statuses become normal and then re-enter the command. If the switch version is not supported, operate the switch directly.

swsag0537

Please modify HBA and driver configuration file (sd.conf/st.conf/etc...) manually for new devices. Then you can make device path of server node using server node device awareness method (e.g. server node reboot or dynamic reconfiguration function.). Could not find any accessible switch. Processing with switch was skipped.

Explanation

Changing of the access path definition for the combination of the specified FC-HBA and storage type is not supported. Set the server node access path manually. After this setting has been made, the target server node must be rebooted in reconfigure mode (not needed if the server node supports the dynamic reconfiguration function.).

An attempt was made to search for a switch that can be used for access path definition but none was found.

This problem occurs if the switch version is not supported, if no switch is registered, or if the device status of the switch is abnormal.

System action

Partially completes the command.

System administrator response

Manually change the access path definition related to the specified FC-HBA and storage type.

Then, the target server node must be rebooted in reconfigure mode. (This is necessary only if the server node does not support the dynamic reconfiguration function.)

Check the switch between the specified FC ports. If no switch is present or if none is registered, no action is required.

If the device status of each switch is abnormal, wait until the device statuses become normal and then re-enter the command. If the switch version is not supported, operate the switch directly.

swsag0538

Access path was defined normally for storage. You can make device path of server node using server node device awareness method (e.g. server node reboot or dynamic reconfiguration function.). Could not find any accessible switch. Processing with switch was skipped.

Explanation

A host affinity operation was performed for the storage. The server node must be rebooted in reconfigure mode to reconfigure the server node special file. The server node need not be rebooted, however, if it supports the dynamic reconfiguration function.

Switch processing was skipped because the switch version was not supported or no available switch was found.

System action

Partially completes the command.

System administrator response

Reboot the server node in reconfigure mode. (This is necessary only if the server node does not support the dynamic reconfiguration function.)

Check the switch between the specified FC ports. If no switch is present or if none is registered, no action is required.

If the device status of each switch is abnormal, wait until the device statuses become normal and then re-enter the command. If the switch version is not supported, operate the switch directly.

swsag0539

Access path was defined normally for storage. You can make device path of server node (Manually Embedded server node) using server node device awareness method (e.g. server node reboot or dynamic reconfigure function.). Skipped processing server node, cause it is a Manually Embedded Device. Could not find any accessible switch. Processing with switch was skipped.

Explanation

A host affinity operation was performed for the storage.

Access path processing was not performed for the server node or FC-HBA adapter because the device was set up using the manual embedding function. Perform manual access path processing for the server node that has a storage affinity function such as HBA WWPN binding.

Next, the server node must be rebooted in reconfigure mode to reconfigure the device special file. The server node need not be rebooted, however, if it supports the dynamic reconfiguration function.

An attempt was made to search for a switch that can be used for access path definition but none was found.

This problem occurs if the switch version is not supported, if no switch is registered, or if the device status of the switch is abnormal.

System action

Partially completes the command.

System administrator response

Perform manual access path processing for the server node that has a storage affinity function such as HBA WWPN binding.

Next, the server node must be rebooted in reconfigure mode to reconfigure the device special file. The server node need not be rebooted, however, if it supports the dynamic reconfiguration function.

Check the switch between the specified FC ports. If no switch is present or if none is registered, no action is required.

If the device status of each switch is abnormal, wait until the device statuses become normal and then re-enter the command. If the switch version is not supported, operate the switch directly.

swsag0540

Access path was defined normally for storage. Please modify HBA and driver configuration file (sd.conf/st.conf/etc...) manually for new devices. Then you can make device path of server node using server node device awareness method (e.g. server node reboot or dynamic reconfiguration function.). Could not find any accessible switch. Processing with switch was skipped.

Explanation

A host affinity operation was performed for the storage.

Changing of the access path definition for the combination of the specified FC-HBA and storage type is not supported. Set the server node access path manually. Next, the server node must be rebooted in reconfigure mode to reconfigure the device special file. The server node need not be rebooted, however, if it supports the dynamic reconfiguration function.

An attempt was made to search for a switch that can be used for access path definition but none was found.

This problem occurs if the switch version is not supported, if no switch is registered, or if the device status of the switch is abnormal.

System action

Partially completes the command.

System administrator response

Manually change the access path definition related to the specified FC-HBA and storage type.

Next, the server node must be rebooted in reconfigure mode to reconfigure the device special file. The server node need not be rebooted, however, if it supports the dynamic reconfiguration function.

Check the switch between the specified FC ports. If no switch is present or if none is registered, no action is required.

If the device status of each switch is abnormal, wait until the device statuses become normal and then re-enter the command. If the switch version is not supported, operate the switch directly.

swsag0541

Access path was defined normally for server node. You can make device path of server node using server node device awareness method (e.g. server node reboot or dynamic reconfiguration function.). Skipped processing storage, cause it is a Manually Embedded Device.

Explanation

WWPN binding for Fibre Channel HBA was set in the server node, and LUN information was set in kernel/drv/sd.conf. The server node must be rebooted in reconfigure mode to reconfigure the device special file. The server node need not be rebooted, however, if it supports the dynamic reconfiguration function.

Access path processing was not performed for the storage device or FC-CA adapter because the device was set up using the manual embedding function. Perform manual access path processing for the storage that has the host affinity function.

System action

Partially completes the command.

System administrator response

Perform manual access path processing for the storage that has the host affinity function.

Next, the server node must be rebooted in reconfigure mode to reconfigure the device special file. The server node need not be rebooted, however, if it supports the dynamic reconfiguration function.

swsag0542

Access path was defined normally for server node. Please modify driver configuration file (sd.conf/st.conf/etc...) manually for new devices. You can make device path of server node using server node device awareness method (e.g. server node reboot or dynamic reconfiguration function.).

Explanation

Access path operation was performed for the server node. For server node access path setting, only the configuration file (WWPN binding) of Fibre Channel HBA was edited. First edit the appropriate driver configuration file (such as /kernel/drv/st.conf) manually.

The server node must be rebooted in reconfigure mode to reconfigure the device special file. However, a server node that supports the dynamic reconfiguration function need not be rebooted.

System action

Partially completes the command.

System administrator response

Manually edit the appropriate driver configuration file (such as /kernel/drv/st.conf). Next, the server node must be rebooted in reconfigure mode to reconfigure the device special file. The server node need not be rebooted, however, if it supports the dynamic reconfiguration function.

swsag0543

Access path was defined normally for server node. Please modify driver configuration file (sd.conf/st.conf/etc...) manually for new devices. Then you can make device path of server node using server node device awareness method (e.g. server node reboot or dynamic reconfiguration function.). Skipped processing storage, cause it is a Manually Embedded Device.

Explanation

Access path operation was performed for the server node. For server node access path setting, only the configuration file (WWPN binding) of Fibre Channel HBA was edited. First edit the appropriate driver configuration file (such as /kernel/drv/st.conf) manually.

Access path processing was not performed for the storage device or FC-CA adapter because the device was set up using the manual embedding function. Perform manual access path processing for the storage that has the host affinity function.

The server node must be rebooted in reconfigure mode to reconfigure the device special file. However, a server node that supports the dynamic reconfiguration function need not be rebooted.

System action

Partially completes the command.

System administrator response

Manually edit the appropriate driver configuration file (such as /kernel/drv/st.conf).

Perform manual access path processing for the storage that has the host affinity function.

Next, the server node must be rebooted in reconfigure mode to reconfigure the device special file. The server node need not be rebooted, however, if it supports the dynamic reconfiguration function.

swsag0544

Access path was defined normally for server node and storage. Please modify driver configuration file (sd.conf/st.conf/etc...) manually for new devices. You can make device path of server node using server node device awareness method (e.g. server node reboot or dynamic reconfiguration function.) after the reboot of selected storage.

Explanation

Access path operation was performed for the server node. For server node access path setting, only the configuration file (WWPN binding) of Fibre Channel HBA was edited. First edit the appropriate driver configuration file (such as /kernel/drv/st.conf) manually.

A host affinity operation was performed for the storage. The storage must be restarted to enable the storage settings. Then, the server node must be rebooted in reconfigure mode to reconfigure the device special file. However, a server node that supports the dynamic reconfiguration function need not be rebooted.

System action

Partially completes the command.

System administrator response

Manually edit the appropriate driver configuration file (such as /kernel/drv/st.conf).

Restart the storage to enable the storage settings. Then, reboot the server node in reconfigure mode. (This is necessary only if the server node does not support the dynamic reconfiguration function.)

swsag0545

Access path was defined normally for server node. You can make device path of server node using server node device awareness method (e.g. server node reboot or dynamic reconfiguration function.).

Explanation

WWPN binding for Fibre Channel HBA was set in the server node, and LUN information was set in kernel/drv/sd.conf. The server node must be rebooted in reconfigure mode to reconfigure the device special file. The server node need not be rebooted, however, if it supports the dynamic reconfiguration function.

System action

Partially completes the command.

System administrator response

Reboot the server node in reconfigure mode.

(This is necessary only if the server node does not support the dynamic reconfiguration function.)

swsag0546

Access path was defined normally for server node. Please modify driver configuration file (sd.conf/st.conf/etc...) manually for new devices. Then you can make device path of server node using server node device awareness method (e.g. server node reboot or dynamic reconfiguration function.).

Explanation

Access path operation was performed for the server node. For server node access path setting, only the configuration file (WWPN binding) of Fibre Channel HBA was edited. First edit the appropriate driver configuration file (such as /kernel/drv/st.conf) manually.

The server node must be rebooted in reconfigure mode to reconfigure the device special file. However, a server node that supports the dynamic reconfiguration function need not be rebooted.

System action

Partially completes the command.

System administrator response

Manually edit the appropriate driver configuration file (such as /kernel/drv/st.conf). Next, the server node must be rebooted in reconfigure mode to reconfigure the device special file. The server node need not be rebooted, however, if it supports the dynamic reconfiguration function.

swsag0547

Access path was defined normally for server node and storage. You can make device path of server node using server node device awareness method (e.g. server node reboot or dynamic reconfiguration function.).

Explanation

WWPN binding for Fibre Channel HBA was set in the server node, and LUN information was set in kernel/drv/sd.conf. Also, host affinity was set for the storage.

The server node must be rebooted in reconfigure mode to reconfigure the device special file on the server node. The server node need not be rebooted, however, if it supports the dynamic reconfiguration function.

System action

Partially completes the command.

System administrator response

The server node must be rebooted in reconfigure mode to reconfigure the device special file. The server node need not be rebooted, however, if it supports the dynamic reconfiguration function.

swsag0548

Access path was defined normally for server node and storage. Please modify driver configuration file (sd.conf/st.conf/etc...) manually for new devices. Then you can make device path of server node using server node device awareness method (e.g. server node reboot or dynamic reconfiguration function.).

Explanation

Access path operation was performed for the server node. For server node access path setting, only the configuration file (WWPN binding) of Fibre Channel HBA was edited. First edit the appropriate driver configuration file (such as /kernel/drv/st.conf) manually.

A host affinity operation was performed for the storage.

The server node must be rebooted in reconfigure mode to reconfigure the device special file. However, a server node that supports the dynamic reconfiguration function need not be rebooted.

System action

Partially completes the command.

System administrator response

Manually edit the appropriate driver configuration file (such as /kernel/drv/st.conf).

The server node must be rebooted in reconfigure mode to reconfigure the device special file. The server node need not be rebooted, however, if it supports the dynamic reconfiguration function.

swsag0549

Access path was defined normally for server node and switch. You can make device path of server node using server node device awareness method (e.g. server node reboot or dynamic reconfiguration function.). Skipped processing storage, cause it is a Manually Embedded Device.

Explanation

For access path definition, HBA WWPN binding was set for the server node, /kernel/drv/sd.conf was set, and zoning was set for the switch.

Access path processing was not performed for the storage device or FC-CA adapter because the device was set up using the manual embedding function. Perform manual access path processing for the storage that has the host affinity function.

System action

Partially completes the command.

System administrator response

Perform manual access path processing for the storage that has the host affinity function.

The server node must be rebooted in reconfigure mode to reconfigure the device special file. The server node need not be rebooted, however, if it supports the dynamic reconfiguration function.

swsag0550

Access path was defined normally for server node and switch. Please modify driver configuration file (sd.conf/st.conf/etc...) manually for new devices. Then you can make device path of server node using server node device awareness method (e.g. server node reboot or dynamic reconfiguration function.).

Explanation

Access path operation was performed for the server node. For server node access path setting, only the configuration file (WWPN binding) of Fibre Channel HBA was edited. First edit the appropriate driver configuration file (such as /kernel/drv/st.conf) manually.

Zoning was set for the switch.

The server node must be rebooted in reconfigure mode to reconfigure the device special file. However, a server node that supports the dynamic reconfiguration function need not be rebooted.

System action

Partially completes the command.

System administrator response

Manually edit the appropriate driver configuration file (such as /kernel/drv/st.conf). Next, the server node must be rebooted in reconfigure mode to reconfigure the device special file. The server node need not be rebooted, however, if it supports the dynamic reconfiguration function.

swsag0551

Access path was defined normally for server node and switch. Please modify driver configuration file (sd.conf/st.conf/etc...) manually for new devices. Then you can make device path of server node using server node device awareness method (e.g. server node reboot or dynamic reconfiguration function.). Skipped processing storage, cause it is a Manually Embedded Device.

Explanation

Access path operation was performed for the server node. For server node access path setting, only the configuration file (WWPN binding) of Fibre Channel HBA was edited. First edit the appropriate driver configuration file (such as /kernel/drv/st.conf) manually.

Access path processing was not performed for the storage device or FC-CA adapter because the device was set up using the manual embedding function. Perform manual access path processing for the storage that has the host affinity function.

Zoning was set for the switch.

The server node must be rebooted in reconfigure mode to reconfigure the device special file. However, a server node that supports the dynamic reconfiguration function need not be rebooted.

System action

Partially completes the command.

System administrator response

Manually edit the appropriate driver configuration file (such as /kernel/drv/st.conf).

Perform manual access path processing for the storage that has the host affinity function.

Next, the server node must be rebooted in reconfigure mode to reconfigure the device special file. The server node need not be rebooted, however, if it supports the dynamic reconfiguration function.

swsag0552

Access path was defined normally for server node and switch and storage. Please modify driver configuration file (sd.conf/st.conf/etc...) manually for new devices. Then you can make device path of server node using server node device awareness method (e.g. server node reboot or dynamic reconfiguration function.) after the reboot of selected storage.

Explanation

Access path operation was performed for the server node. For server node access path setting, only the configuration file (WWPN binding) of Fibre Channel HBA was edited. First edit the appropriate driver configuration file (such as /kernel/drv/st.conf) manually.

Zoning was set for the switch.

A host affinity operation was performed for the storage. The storage must be restarted to enable the storage settings. Then, the server node must be rebooted in reconfigure mode to reconfigure the device special file. However, a server node that supports the dynamic reconfiguration function need not be rebooted.

System action

Partially completes the command.

System administrator response

Manually edit the appropriate driver configuration file (such as /kernel/drv/st.conf).

Restart the storage to enable the storage settings. Then, reboot the server node in reconfigure mode. (This is necessary only if the server node does not support the dynamic reconfiguration function.)

swsag0553

Access path was defined normally for server node and switch. You can make device path of server node using server node device awareness method (e.g. server node reboot or dynamic reconfiguration function.).

Explanation

WWPN binding for Fibre Channel HBA was set in the server node, and LUN information was set in kernel/drv/sd.conf. Zoning was set for the switch.

The server node must be rebooted in reconfigure mode to reconfigure the device special file. The server node need not be rebooted, however, if it supports the dynamic reconfiguration function.

System action

Partially completes the command.

System administrator response

Reboot the server node in reconfigure mode. (This is necessary only if the server node does not support the dynamic reconfiguration function.)

swsag0554

Access path was defined normally for server node and switch. Please modify driver configuration file (sd.conf/st.conf/etc...) manually for new devices. Then you can make device path of server node using server node device awareness method (e.g. server node reboot or dynamic reconfiguration function.).

Explanation

WWPN binding for Fibre Channel HBA was set in the server node, and LUN information was set in kernel/drv/sd.conf. Zoning was set for the switch.

The server node must be rebooted in reconfigure mode to reconfigure the device special file. The server node need not be rebooted, however, if it supports the dynamic reconfiguration function.

System action

Partially completes the command.

System administrator response

Reboot the server node in reconfigure mode.

(This is necessary only if the server node does not support the dynamic reconfiguration function.)

swsag0555

Access path was defined normally for server node and switch and storage. You can make device path of server node using server node device awareness method (e.g. server node reboot or dynamic reconfiguration function.).

Explanation

WWPN binding for Fibre Channel HBA was set in the server node, and LUN information was set in kernel/drv/sd.conf. Also, host affinity was set for the storage. Zoning was set for the switch.

The server node must be rebooted in reconfigure mode to reconfigure the device special file on the server node. The server node need not be rebooted, however, if it supports the dynamic reconfiguration function.

System action

Partially completes the command.

System administrator response

The server node must be rebooted in reconfigure mode to reconfigure the device special file. The

server node need not be rebooted, however, if it supports the dynamic reconfiguration function.

swsag0556

Access path was defined normally for server node and switch and storage. Please modify driver configuration file (sd.conf/st.conf/etc...) manually for new devices. Then you can make device path of server node using server node device awareness method (e.g. server node reboot or dynamic reconfiguration function.).

Explanation

Access path operation was performed for the server node. For server node access path setting, only the configuration file (WWPN binding) of Fibre Channel HBA was edited. First edit the appropriate driver configuration file (such as /kernel/drv/st.conf) manually.

A host affinity operation was performed for the storage. Zoning was set for the switch.

The server node must be rebooted in reconfigure mode to reconfigure the device special file. The server node need not be rebooted, however, if it supports the dynamic reconfiguration function.

System action

Partially completes the command.

System administrator response

Manually edit the appropriate driver configuration file (such as /kernel/drv/st.conf).

The server node must be rebooted in reconfigure mode. The server node need not be rebooted, however, if it supports the dynamic reconfiguration function.

swsag0557

Access path was defined normally for server node. You can make device path of server node using server node device awareness method (e.g. server node reboot or dynamic reconfiguration function.). Could not find any accessible switch. Processing with switch was skipped.

Explanation

WWPN binding for Fibre Channel HBA was set in the server node, and LUN information was set in kernel/drv/sd.conf.

The server node must be rebooted in reconfigure mode to reconfigure the device special file. The server node need not be rebooted, however, if it supports the dynamic reconfiguration function.

An attempt was made to search for a switch that can be used for access path definition but none was found.

This problem occurs if the switch version is not supported, if no switch is registered, or if the device status of the switch is abnormal.

System action

Partially completes the command.

System administrator response

The server node must be rebooted in reconfigure mode. The server node need not be rebooted, however, if it supports the dynamic reconfiguration function.

Check the switch between the specified FC ports. If no switch is present or if none is registered, no action is required.

If the device status of each switch is abnormal, wait until the device statuses become normal and then re-enter the command. If the switch version is not supported, operate the switch directly.

swsag0558

Access path was defined normally for server node. You can make device path of server node using server node device awareness method (e.g. server node reboot or dynamic reconfiguration function.). Skipped processing storage, cause it is a Manually Embedded Device. Could not find any accessible switch. Processing with switch was skipped.

Explanation

WWPN binding for Fibre Channel HBA was set in the server node, and LUN information was set in kernel/drv/sd.conf. The server node must be rebooted in reconfigure mode to reconfigure the device special file. The server node need not be rebooted, however, if it supports the dynamic reconfiguration function.

Access path processing was not performed for the storage device or FC-CA adapter because the device was set up using the manual embedding function. Perform manual access path processing for the storage that has the host affinity function.

An attempt was made to search for a switch that can be used for access path definition but none was found.

This problem occurs if the switch version is not supported, if no switch is registered, or if the device status of the switch is abnormal.

System action

Partially completes the command.

System administrator response

Perform manual access path processing for the storage that has the host affinity function.

Next, the server node must be rebooted in reconfigure mode to reconfigure the device special file. The server node need not be rebooted, however, if it supports the dynamic reconfiguration function.

Check the switch between the specified FC ports. If no switch is present or if none is registered, no action is required.

If the device status of each switch is abnormal, wait until the device statuses become normal and then re-enter the command. If the switch version is not supported, operate the switch directly.

swsag0559

Access path was defined normally for server node. Please modify driver configuration file (sd.conf/st.conf/etc...) manually for new devices. Then you can make device path of server node using server node device awareness method (e.g. server node reboot or dynamic reconfiguration function.). Could not find any accessible switch. Processing with switch was skipped.

Explanation

Access path operation was performed for the server node. For server node access path setting, only the configuration file (WWPN binding) of Fibre Channel HBA was edited. First edit the appropriate driver configuration file (such as /kernel/drv/st.conf) manually.

The server node must be rebooted in reconfigure mode to reconfigure the device special file. However, a server node that supports the dynamic reconfiguration function need not be rebooted.

An attempt was made to search for a switch that can be used for access path definition but none was found.

This problem occurs if the switch version is not supported, if no switch is registered, or if the device status of the switch is abnormal.

System action

Partially completes the command.

System administrator response

Manually edit the appropriate driver configuration file (such as /kernel/drv/st.conf). Next, the server node must be rebooted in reconfigure mode to reconfigure the device special file. The server node need not be rebooted, however, if it supports the dynamic reconfiguration function.

Check the switch between the specified FC ports. If no switch is present or if none is registered, no action is required.

If the device status of each switch is abnormal, wait until the device statuses become normal and then re-enter the command. If the switch version is not supported, operate the switch directly.

swsag0560

Access path was defined normally for server node. Please modify driver configuration file (sd.conf/st.conf/etc...) manually for new devices. Then you can make device path of server node using server node device awareness method (e.g. server node reboot or dynamic reconfiguration function.). Skipped processing storage, cause it is a Manually Embedded Device. Could not find any accessible switch. Processing with switch was skipped.

Explanation

Access path operation was performed for the server node. For server node access path setting, only the configuration file (WWPN binding) of Fibre Channel HBA was edited. First edit the appropriate driver configuration file (such as /kernel/drv/st.conf) manually.

Access path processing was not performed for the storage device or FC-CA adapter because the device was set up using the manual embedding function. Perform manual access path processing for the storage that has the host affinity function.

The server node must be rebooted in reconfigure mode to reconfigure the device special file. However, a server node that supports the dynamic reconfiguration function need not be rebooted.

An attempt was made to search for a switch that can be used for access path definition but none was found.

This problem occurs if the switch version is not supported, if no switch is registered, or if the device status of the switch is abnormal.

System action

Partially completes the command.

System administrator response

Manually edit the appropriate driver configuration file (such as /kernel/drv/st.conf).

Perform manual access path processing for the storage that has the host affinity function.

Next, the server node must be rebooted in reconfigure mode to reconfigure the device special file. The server node need not be rebooted, however, if it supports the dynamic reconfiguration function.

Check the switch between the specified FC ports. If no switch is present or if none is registered, no action is required.

If the device status of each switch is abnormal, wait until the device statuses become normal and then re-enter the command. If the switch version is not supported, operate the switch directly.

swsag0561

Access path was defined normally for server node and storage. You can make device path of server node using server node device awareness method (e.g. server node reboot or dynamic reconfiguration function.) after the reboot of selected storage. Could not find any accessible switch. Processing with switch was skipped.

Explanation

WWPN binding for Fibre Channel HBA was set in the server node, and LUN information was set in kernel/drv/sd.conf. Also, host affinity was set for the storage.

To reconfigure the device special file on the server node, first restart the storage and then, after it has restarted normally, reboot the target server node in reconfigure mode. The server node need not be rebooted, however, if it supports the dynamic reconfiguration function.

An attempt was made to search for a switch that can be used for access path definition but none was found.

This problem occurs if the switch version is not supported, if no switch is registered, or if the device status of the switch is abnormal.

System action

The command is completed normally.

System administrator response

Restart the storage and then reboot the server node in reconfigure mode. (This is necessary only if the server node does not support the dynamic reconfiguration function.)Check the switch between the specified FC ports. If no switch is present or if none is registered, no action is required.

If the device status of each switch is abnormal, wait until the device statuses become normal and then re-enter the command. If the switch version is not supported, operate the switch directly.

swsag0562

Access path was defined normally for server node and storage. Please modify driver configuration file (sd.conf/st.conf/etc...) manually for new devices. Then you can make device path of server node using server node device awareness method (e.g. server node reboot or dynamic reconfiguration function.) after the reboot of selected storage. Could not find any accessible switch. Processing with switch was skipped.

Explanation

Access path operation was performed for the server node. For server node access path setting, only the configuration file (WWPN binding) of Fibre Channel HBA was edited. First edit the appropriate driver configuration file (such as /kernel/drv/st.conf) manually.

A host affinity operation was performed for the storage. The storage must be restarted to enable the storage settings. Then, the server node must be rebooted in reconfigure mode to reconfigure the device special file. The server node need not be rebooted, however, if it supports the dynamic reconfiguration function.

An attempt was made to search for a switch that can be used for access path definition but none was found.

This problem occurs if the switch version is not supported, if no switch is registered, or if the device status of the switch is abnormal.

System action

Partially completes the command.

System administrator response

Manually edit the appropriate driver configuration file (such as /kernel/drv/st.conf).

Restart the storage to enable the storage settings. Then, reboot the server node in reconfigure mode. (This is necessary only if the server node does not support the dynamic reconfiguration function.)

Check the switch between the specified FC ports. If no switch is present or if none is registered, no action is required.

If the device status of each switch is abnormal, wait until the device statuses become normal and then re-enter the command. If the switch version is not supported, operate the switch directly.

swsag0563

Access path was defined normally for server node. You can make device path of server node using server node device awareness method (e.g. server node reboot or dynamic reconfiguration function.). Could not find any accessible switch. Processing with switch was skipped.

Explanation

WWPN binding for Fibre Channel HBA was set in the server node, and LUN information was set in kernel/drv/sd.conf. The server node must be rebooted in reconfigure mode to reconfigure the device special file. The server node need not be rebooted, however, if it supports the dynamic reconfiguration function.

An attempt was made to search for a switch that can be used for access path definition but none was found.

This problem occurs if the switch version is not supported, if no switch is registered, or if the device status of the switch is abnormal.

System action

The command is completed normally.

System administrator response

Reboot the server node in reconfigure mode.

(This is necessary only if the server node does not support the dynamic reconfiguration function.)

Check the switch between the specified FC ports. If no switch is present or if none is registered, no action is required.

If the device status of each switch is abnormal, wait until the device statuses become normal and then re-enter the command. If the switch version is not supported, operate the switch directly.

swsag0564

Access path was defined normally for server node. Please modify driver configuration file (sd.conf/st.conf/etc...) manually for new devices. Then you can make device path of server node using server node device awareness method (e.g. server node reboot or dynamic reconfiguration function.). Could not find any accessible switch. Processing with switch was skipped.

Explanation

Access path operation was performed for the server node. For server node access path setting, only the configuration file (WWPN binding) of Fibre Channel HBA was edited. First edit the appropriate driver configuration file (such as /kernel/drv/st.conf) manually.

The server node must be rebooted in reconfigure mode to reconfigure the device special file. However, a server node that supports the dynamic reconfiguration function need not be rebooted.

An attempt was made to search for a switch that can be used for access path definition but none was found.

This problem occurs if the switch version is not supported, if no switch is registered, or if the device status of the switch is abnormal.

System action

Partially completes the command.

System administrator response

Manually edit the appropriate driver configuration file (such as /kernel/drv/st.conf). Next, the server node must be rebooted in reconfigure mode to reconfigure the device special file. The server node need not be rebooted, however, if it supports the dynamic reconfiguration function.

Check the switch between the specified FC ports. If no switch is present or if none is registered, no action is required.

If the device status of each switch is abnormal, wait until the device statuses become normal and then re-enter the command. If the switch version is not supported, operate the switch directly.

swsag0565

Access path was defined normally for server node and storage. You can make device path of server node using server node device awareness method (e.g. server node reboot or dynamic reconfiguration function.). Could not find any accessible switch. Processing with switch was skipped.

Explanation

WWPN binding for Fibre Channel HBA was set in the server node, and LUN information was set in kernel/drv/sd.conf. Also, host affinity was set for the storage.

The server node must be rebooted in reconfigure mode to reconfigure the device special file on the server node. The server node need not be rebooted, however, if it supports the dynamic reconfiguration function.

An attempt was made to search for a switch that can be used for access path definition but none was found.

This problem occurs if the switch version is not supported, if no switch is registered, or if the device status of the switch is abnormal.

System action

The command is completed normally.

System administrator response

The server node must be rebooted in reconfigure mode to reconfigure the device special file. The server node need not be rebooted, however, if it supports the dynamic reconfiguration function.

Check the switch between the specified FC ports. If no switch is present or if none is registered, no action is required.

If the device status of each switch is abnormal, wait until the device statuses become normal and then re-enter the command. If the switch version is not supported, operate the switch directly.

swsag0566

Access path was defined normally for server node and storage. Please modify driver configuration file (sd.conf/st.conf/etc...) manually for new devices. Then you can make device path of server node using server node device awareness method (e.g. server node reboot or dynamic reconfiguration function.). Could not find any accessible switch. Processing with switch was skipped.

Explanation

Access path operation was performed for the server node. For server node access path setting, only the configuration file (WWPN binding) of Fibre Channel HBA was edited. First edit the appropriate driver configuration file (such as /kernel/drv/st.conf) manually.

A host affinity operation was performed for the storage.

The server node must be rebooted in reconfigure mode to reconfigure the device special file. The server node need not be rebooted, however, if it supports the dynamic reconfiguration function.

An attempt was made to search for a switch that can be used for access path definition but none was found.

This problem occurs if the switch version is not supported, if no switch is registered, or if the device status of the switch is abnormal.

System action

Partially completes the command.

System administrator response

Manually edit the appropriate driver configuration file (such as /kernel/drv/st.conf).

The server node must be rebooted in reconfigure mode to reconfigure the device special file. The server node need not be rebooted, however, if it supports the dynamic reconfiguration function.

Check the switch between the specified FC ports. If no switch is present or if none is registered, no action is required.

If the device status of each switch is abnormal, wait until the device statuses become normal and then re-enter the command. If the switch version is not supported, operate the switch directly.

swsag0567

Skipped processing storage, cause it is a Manually Embedded Device.

Explanation

Access path processing was not performed for the storage device or FC-CA adapter because the device was set up using the manual embedding function. Perform manual access path processing for the storage that has the host affinity function.

System action

The command is completed normally.

System administrator response

Perform manual access path processing for the storage that has the host affinity function.

swsag0568

Access path was defined normally for storage. Reboot of the selected server node is required to enable definition after the reboot of selected storage.

Explanation

A host affinity operation was performed for the storage. The storage must be restarted to enable the storage settings and the server node must be rebooted.

System action

The command is completed normally.

System administrator response

Restart the storage to enable the storage settings. Then, reboot the server node.

swsag0569

Access path was defined normally for storage. Reboot of the selected server node is required to enable definition.

Explanation

A host affinity operation was performed for the storage. The server node must be rebooted.

System action

The command is completed normally.

System administrator response

Reboot the server node.

swsag0570

Access path was defined normally for switch. Reboot of the selected server node is required to enable definition.

Explanation

Zoning was set for the switch.

System action

The command is completed normally.

System administrator response

Reboot the server node.

swsag0571

Access path was defined normally for switch. Reboot of the selected server node is required to enable definition. Skipped processing storage, cause it is a Manually Embedded Device.

Explanation

Zoning was set for the switch.

Access path processing was not performed for the storage device or FC-CA adapter because the device was set up using the manual embedding function. Perform manual access path processing for the storage that has the host affinity function.

The server node must be rebooted.

System action

The command is completed normally.

System administrator response

Perform manual access path processing for the storage that has the host affinity function.

Reboot the server node.

swsag0572

Access path was defined normally for switch and storage. Reboot of the selected server node is required to enable definition after the reboot of selected storage.

Explanation

Zoning was set for the switch. A host affinity operation was performed for the storage. The storage must be restarted to enable the storage settings and the server node must be rebooted.

System action

The command is completed normally.

System administrator response

Restart the storage to enable the storage settings. Then, reboot the server node.

swsag0573

Access path was defined normally for switch. Reboot of the selected server node is required to enable definition.

Explanation

Zoning was set for the switch.

System action

The command is completed normally.

System administrator response

Reboot the server node.

swsag0574

Access path was defined normally for switch and storage. Reboot of the selected server node is required to enable definition.

Explanation

Zoning was set for the switch. A host affinity operation was performed for the storage. The server node must be rebooted.

System action

The command is completed normally.

System administrator response

Reboot the server node.

swsag0575

Could not find any accessible switch. Processing with switch was skipped.

Explanation

An attempt was made to search for a switch that can be used for access path definition but none was found.

This problem occurs if the switch version is not supported, if no switch is registered, or if the device status of the switch is abnormal.

System action

Partially completes the command.

System administrator response

Check the switch between the specified FC ports. If no switch is present or if none is registered, no action is required.

If the device status of each switch is abnormal, wait until the device statuses become normal and then re-enter the command. If the switch version is not supported, operate the switch directly.

swsag0576

Skipped processing storage, cause it is a Manually Embedded Device. Could not find any accessible switch. Processing with switch was skipped.

Explanation

Access path processing was not performed for the storage device or FC-CA adapter because the device was set up using the manual embedding function. Perform manual access path processing for the storage that has the host affinity function.

An attempt was made to search for a switch that can be used for access path definition but none was found.

This problem occurs if the switch version is not supported, if no switch is registered, or if the device status of the switch is abnormal.

System action

The command is completed normally.

System administrator response

Perform manual access path processing for the storage that has the host affinity function.

If the device status of each switch is abnormal, wait until the device statuses become normal and then re-enter the command. If the switch version is not supported, operate the switch directly.

swsag0577

Access path was defined normally for storage. Reboot of the selected server node is required to enable definition after the reboot of selected storage. Could not find any accessible switch. Processing with switch was skipped.

Explanation

A host affinity operation was performed for the storage. The storage must be restarted to enable the storage settings and the server node must be rebooted.

An attempt was made to search for a switch that can be used for access path definition but none was found.

This problem occurs if the switch version is not supported, if no switch is registered, or if the device status of the switch is abnormal.

System action

The command is completed normally.

System administrator response

Restart the storage to enable the storage settings. Then, reboot the server node.

If the device status of each switch is abnormal, wait until the device statuses become normal and then re-enter the command. If the switch version is not supported, operate the switch directly.

swsag0578

Could not find any accessible switch. Processing with switch was skipped.

Explanation

An attempt was made to search for a switch that can be used for access path definition but none was found.

This problem occurs if the switch version is not supported, if no switch is registered, or if the device status of the switch is abnormal.

System action

Partially completes the command.

System administrator response

Check the switch between the specified FC ports. If no switch is present or if none is registered, no action is required.

If the device status of each switch is abnormal, wait until the device statuses become normal and then re-enter the command. If the switch version is not supported, operate the switch directly.

swsag0579

Access path was defined normally for storage. Reboot of the selected server node is required to enable definition. Could not find any accessible switch. Processing with switch was skipped.

Explanation

A host affinity operation was performed for the storage. The server node must be rebooted.

An attempt was made to search for a switch that can be used for access path definition but none was found.

This problem occurs if the switch version is not supported, if no switch is registered, or if the device status of the switch is abnormal.

System action

The command is completed normally.

System administrator response

Reboot the server node.

Check the switch between the specified FC ports. If no switch is present or if none is registered, no action is required.

If the device status of each switch is abnormal, wait until the device statuses become normal and then re-enter the command. If the switch version is not supported, operate the switch directly.

swsag0591

The Input CA was not found.

Explanation

The specified CA cannot be found. Either the specified CA is invalid, or the storage device that was used to install the CA has not been registered.

System action

Interrupts the processing

System administrator response

Perform either of the following actions and then re-execute the operation.

  • If the specified CA is invalid,

    Check whether the CA that was installed in the storage device has been specified correctly.

  • If the storage device has not been registered,

    Register the storage device that was used to install the specified CA.

swsag0592

The specified switch is NO SECURITY state, it does not have any Zoning setting. Setting WWPN Zoning to the switch bring you higher security level, but it may cause the problem of current Access Path. Please refer the user/operation manual for the problem of current Access Path, how to change the switch setting and details.

Explanation

The status of the operation target switch is that there are NO_SECURITY settings.

System action

None

System administrator response

The system administrator checks the system security.

swsag0593

Access path addition or deletion went wrong.

Explanation

In the state of the device that relates to access path setting, access path cannot be set.

System action

Interrupts the processing

System administrator response

Please remove the following causes. Afterwards, please operate it again.

  • When the server node equipped with HBA specified for the -hba option is registered in this software

    • Please start this server node when you specify "add". Moreover, please remove the cause when the monitoring status of HBA is not normal.

    • Please stop this server node when you specify "delete".

  • Please register when storage or bridge is not registered in this software.

  • Please remove the cause when the monitoring status of storage or bridge is not normal.

If this fails to solve the problem, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

swsag0601

Exit Performance Manager.

Explanation

Confirm whether or not to end performance management.

System action

If <OK> button is clicked, performance management ends.

System administrator response

To end performance management, click <OK> button. Otherwise, click <Cancel> button.

swsag0602

Close All Performance Management Windows.

Explanation

Confirm whether or not to close all the performance management windows.

System action

If <OK> button is clicked, all the performance management windows close.

System administrator response

To close the performance management windows, click <OK> button. Otherwise, click <Cancel> button.

swsag0605

The device with IP Address %IP_ADDRESS% was registered.

Explanation

This message indicates that the device with IP address %IP_ADDRESS% has been registered in the performance management window. %IP_ADDRESS% is used as the device name.

Parameters

%IP_ADDRESS% : IP address of the device registered in the performance management window

System action

Registers the device in the performance management window and displays the device configuration as a tree view.

System administrator response

None

swsag0606

The device with IP address %IP_ADDRESS% was registered with device name %NAME%.

Explanation

This message indicates that the device with IP address %IP_ADDRESS% has been registered in the performance management window. %NAME% is used as the device name.

Parameters

%IP_ADDRESS% : IP address of the device registered in the performance management window
%NAME% : Name assigned to the device

System action

Registers the device in the performance management window and displays the device configuration as a tree view.

System administrator response

None

swsag0607

The device with IP address %IP_ADDRESS% has already been registered.

Explanation

This message indicates that the device with the specified IP address was not newly registered because it has already been registered in the performance window.

Parameters

%IP_ADDRESS% : IP address of the device already registered in the performance window

System action

None

System administrator response

Use a device that has already been registered.

swsag0608

The device with IP address %IP_ADDRESS% has already been registered with device name %NAME%.

Explanation

This message indicates that the device with the specified IP address was not newly registered because it has already been registered in the performance window.

Parameters

%IP_ADDRESS% : IP address of the device already registered in the performance window
%NAME% : Name of the device already registered in the performance window

System action

None

System administrator response

Use a device that has already been registered.

swsag0609

Uncompleted to register the device %IP_ADDRESS%

Explanation

A device could not be registered successfully because the configuration file for the device was not found or could not be read.

Parameters

%IP_ADDRESS% : IP address of the device registered in the performance management window

System action

Registers the device but does not display the device internal structure in tree view format.

System administrator response

A performance graph cannot be displayed under this condition. Select "Create Configuration Information File" from the performance management window for the target device.

swsag0610

Failed to register the device with IP address %IP_ADDRESS.

Explanation

This message indicates that the device could not be registered in the performance management window because an error occurred during network communication with the device or the device did not support the performance monitoring function.

Parameters

%IP_ADDRESS% : IP address of the device to be registered in the performance management window

System action

Interrupts the processing.

System administrator response

If a detail message is output, check the message content. Check the device and network environment for errors, and then re-execute the processing.

swsag0611

Failed to register the device %NAME%(%IP_ADDRESS%).

Explanation

This message indicates that the device could not be registered in the performance management window because an error occurred during network communication with the device or the device did not support the performance monitoring function.

Parameters

%NAME% : Name of the device to be registered in the performance management window
%IP_ADDRESS% : IP address of the device to be registered in the performance management window

System action

Interrupts the processing.

System administrator response

If a detail message is output, check the message content. Check the device and network environment for errors, and then re-execute the processing.

swsag0612

Failed to update the registration information for device %NAME%(%IP_ADDRESS%).

Explanation

The device registration information could not be updated because an error occurred while the configuration file was read or written.

Parameters

%NAME% : Name of the registered device
%IP_ADDRESS% : IP address of the registered device

System action

Interrupts the processing.

System administrator response

If a detail message is output, check the message content. If the system failed to read the configuration file, select "Create Configuration Information File" and then update the registration information again. If the system failed to write to the configuration file, update the registration information again.

swsag0613

All performance graph of the device is deleted. A device configuration file for device %NAME%(%IP_ADDRESS%) will be created and the tree view will be updated. Also, all the performance graphs of device %NAME%(%IP_ADDRESS%) will be deleted. And the setting of threshold monitoring will be deleted. If you continue threshold monitoring, please set the threshold again after the device configuration.

Explanation

Configuration information is read from the specified device and saved to a file. The device tree is updated and the device performance graph is deleted from the display. The settings for device threshold monitoring are also deleted.

Parameters

%NAME% : Name of the device subject to performance monitoring
%IP_ADDRESS% : IP address of the device subject to performance monitoring

System action

When <OK> button is clicked, the system creates a configuration file, updates the device tree, deletes the performance graph, and then deletes the threshold monitoring settings.

System administrator response

To create a configuration file, click <OK> button. Otherwise, click <Cancel> button.

swsag0614

Creation of the device configuration file for device %NAME%(%IP_ADDRESS%) has been completed.

Explanation

This message indicates that configuration information was read from the specified device and has been successfully saved to a file.

Parameters

%NAME% : Name of the device subject to performance monitoring
%IP_ADDRESS% : IP address of the device subject to performance monitoring

System action

Creates a configuration file, updates the device tree, and deletes the displayed performance graph.

System administrator response

None

swsag0615

Failed to create the device configuration file for device %NAME%(%IP_ADDRESS%).

Explanation

This message indicates that an error occurred while configuration information was being read from the device or while the read configuration information was being saved to a file.

Parameters

%NAME% : Name of the device subject to performance monitoring
%IP_ADDRESS% : IP address of the device subject to performance monitoring

System action

Interrupts the processing.

System administrator response

If a detail message is output, check the message content. If an error occurred during network communication with the device, check the device and network environment for errors. Also check whether the user is authorized to write to the file system to which the configuration information is to be saved or whether the file system has sufficient free space. Then, re-execute processing.

swsag0616

Failed to set up the performance monitoring on device %NAME%(%IP_ADDRESS%).

Explanation

This message indicates that performance monitoring setting failed because an error occurred during network communication with the device or during processing for saving the monitoring status data to the performance management definition file.

Parameters

%NAME% : Name of the device subject to performance monitoring
%IP_ADDRESS% : IP address of the device subject to performance monitoring

System action

Interrupts the processing.

System administrator response

If a detail message is output, check the message content. If an error occurred during network communication with the device, check the device and network environment for errors. Also, check whether the file system which is to be written into the performance management definition file has the written permission and whether the file system has enough free space. Then, re-execute processing.

swsag0617

Device %NAME%(%IP_ADDRESS%) will be deleted.

Explanation

Confirm whether or not to delete the specified device from the performance management window. When deleting the device, select whether to stop performance monitoring for the device.

Parameters

%NAME% : Name of the registered device
%IP_ADDRESS% : IP address of the registered device

System action

When <OK> button is clicked, deletes the specified device and no longer displays it in the performance management window.

System administrator response

To delete the device, click <OK> button. Otherwise, click <Cancel> button. Also, select whether to stop performance monitoring for the device.

swsag0618

The performance monitoring on device %NAME%(%IP_ADDRESS%) will be deleted without being stopped.

Explanation

Confirm whether or not to delete the device from the performance management window without stopping performance monitoring.

Parameters

%NAME% : Name of the registered device
%IP_ADDRESS% : IP address of the registered device

System action

When <OK> button is clicked, the specified device is deleted but performance monitoring for the device continues. When the <Cancel> button is clicked, a configuration dialog box asking whether to delete the device is displayed again.

System administrator response

To delete the device without stopping performance monitoring, click <OK> button. Otherwise, click <Cancel> button.

swsag0619

Failed to delete device %NAME%(%IP_ADDRESS%).

Explanation

This message indicates that the specified device could not be deleted from the performance management window because of an error in the stopping processing of performance monitoring for deleting the device. The error occurred during network communication with the device or during processing for saving performance monitoring status data to the performance management definition file.

Parameters

%NAME% : Name of the target device
%IP_ADDRESS% : IP address of the target device

System action

Interrupts the processing.

System administrator response

If a detail message is output, check the message content. When performance monitoring is stopped for deletion of the device, an error may occur during network communication with the device or during the processing for saving the performance monitoring status data to the performance management definition file. Check the device and network environment for errors, and then re-execute the processing.

swsag0620

Failed to view the performance graph.

Explanation

This message indicates that the performance graph could not be displayed because an error occurred while the performance information file or device configuration information file was read.

System action

Interrupts the processing.

System administrator response

If a detail message is output, check the message content. If a performance information file that may not be read successfully exists, the performance cannot be graphed. Delete the performance information file or move it to another location. If the configuration information file could not be read, select "Create Configuration Information File" from the performance management window and re-execute performance graph display processing.

swsag0622

Failed to load the registered device.

Explanation

This message indicates that the device on which a configuration information file was created could not be registered automatically when the system started. The performance information file may contain an error.

System action

Interrupts the processing.

System administrator response

If a detail message is output, check the message content. Execute "Create Configuration Information File" from the performance management window.

If this fails to solve the problem when the Manager is restarted, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

swsag0623

Failed to automatically start the performance monitoring.

Explanation

When the Manager was started, the performance monitoring facility that was running previously could not be started automatically. An error may have occurred in the performance management definition file or in the configuration information file of the target device.

System action

Interrupts the processing.

System administrator response

If a detail message is output, check the message content. Start performance monitoring again or select "Create Configuration Information File" from the performance management window.

If this fails to solve the problem when the Manager is restarted, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

swsag0624

Failed to show device %NAME%(%IP_ADDRESS%) as a tree view.

Explanation

This message indicates that the device configuration could not be displayed as a tree view because the configuration information file of the target device could not be read and device configuration information could not be obtained.

Parameters

%NAME% : Name of the target device
%IP_ADDRESS% : IP address of the target device

System action

Interrupts the processing.

System administrator response

If a detail message is output, check the message content. If the configuration information file could not be read, select "Create Configuration Information File" from the performance management window.

swsag0625

Failed to show device %NAME%(%IP_ADDRESS%) as a tree view.

Explanation

This message indicates that device configuration information cannot be created because the target device is under threshold monitoring.

Parameters

%NAME% : Name of the target device
%IP_ADDRESS% : IP address of the target device

System action

Interrupts the processing.

System administrator response

Stop threshold monitoring for the target device by selecting "Set Threshold/Start Monitoring/Stop Monitoring" from the menu. Execute "Create Configuration Information File" from the performance management window.

swsag0650

A network socket error occurred in communication with a device {0}. Please check the device or the network infrastructure.

Explanation

This message indicates that an error occurred during network communication with the device subject to performance monitoring.

Parameters

{0} : IP address of the target device

System action

If an error occurs during performance monitoring, processing is retried and continued. In other cases, processing is interrupted.

System administrator response

Check the target device or network environment for errors.

swsag0651

A network I/O error occurred in communication with a device {0}. Please check the device or the network infrastructure.

Explanation

This message indicates that an error occurred during network communication with the device subject to performance monitoring.

Parameters

{0} : IP address of the target device

System action

If an error occurs during performance monitoring, processing is retried and continued. In other cases, processing is interrupted.

System administrator response

Check the target device or network environment for errors.

swsag0652

A network timeout error occurred in communication with a device {0}. Please check the device or the network infrastructure.

Explanation

This message indicates that a time-out occurred during network communication with the device subject to performance monitoring.

Parameters

{0} : IP address of the target device

System action

If an error occurs during performance monitoring, processing is retried and continued. In other cases, processing is interrupted.

System administrator response

Check the target device or network environment for errors.

swsag0653

An address {0} is wrong.

Explanation

This message indicates that the specified address is invalid for the IP address.

Parameters

{0} : Specified address

System action

Interrupts the processing.

System administrator response

Specify a valid IP address.

swsag0654

A communication error occurred in communication with the Performance Monitor Engine. Please check the Performance Monitor Engine or the network infrastructure.

Explanation

This message indicates that a communication error occurred during processing driven from the performance management window.

System action

Interrupts the processing.

System administrator response

Make sure that the product version/level is the same between the Manager and Client.

If a patch has been applied, refer to the application conditions provided in the patch description about the patch applied to the Manager, and make sure that the patch has also been applied to the Client.

If re-executing processing does not solve the problem, collect the data required for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag0655

A SNMP protocol error occurred in communication with a device {0}. Please check the device or the network infrastructure.

Explanation

This message indicates that an error occurred during SNMP protocol communication for obtaining performance information from the device subject to performance monitoring.

Parameters

{0} : IP address of the target device

System action

Interrupts the processing.

System administrator response

Check the device or network environment for errors.

If this fails to solve the problem, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

swsag0661

Unable to find the performance configuration file {0}.

Explanation

This message indicates that various settings for the performance management program could not be performed because the performance management definition file was not found.

Parameters

{0} : Name of performance management definition file

System action

Interrupts the processing.

System administrator response

Allocate the performance management definition file to the specified directory and then restart the OpenCIMOM daemon. (For an explanation of the restart procedure, refer to "Chapter 12 Command References" in the ETERNUS SF Storage Cruiser User's Guide.)

If this fails to solve the problem, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

swsag0662

Unable to create the performance configuration file {0}. Please check write permission of the filesystem or the capacity of the filesystem.

Explanation

This message indicates that the current definition information could not be saved because a performance management definition file could not be created.

Parameters

{0} : Name of performance management definition file

System action

Interrupts the processing.

System administrator response

Check whether the file system is write-protected or check the size of the file system, and then re-execute the processing.

swsag0664

Unable to read the performance configuration file {0}. The contents of the file may be incorrect.

Explanation

This message indicates that settings for the performance management program could not be made because the performance management definition file could not be read. The definition file may not exist or may contain an error.

Parameters

{0} : Name of the performance management definition file

System action

Interrupts the processing.

System administrator response

Allocate the error-free performance management definition file to the specified directory and then restart the OpenCIMOM daemon. (For an explanation of the restart procedure, refer to "Chapter 12 Command References" in the ETERNUS SF Storage Cruiser User's Guide.)

If this fails to solve the problem, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

swsag0665

Unable to write the performance configuration file {0}. Please check write permission of the filesystem or the capacity of the filesystem.

Explanation

This message indicates that the current definition information could not be saved because a performance management definition file could not be created.

Parameters

{0} : Name of performance management definition file

System action

Interrupts the processing.

System administrator response

Check whether the file system is write-protected or check the size of the file system, and then re-execute the processing.

swsag0666

Unable to find a config XML file {0}.

Explanation

This message indicates that the configuration information file for the device subject to performance monitoring was not found.

Parameters

{0} : Name of configuration information file

System action

Interrupts the processing.

System administrator response

Execute "Create Configuration Information File" from the performance management window.

swsag0667

Unable to create a config XML file {0}. Please check write permission of the filesystem or the capacity of the filesystem.

Explanation

This message indicates that a configuration information file for the device subject to performance monitoring could not be created.

Parameters

{0} : Name of configuration information file

System action

Interrupts the processing.

System administrator response

Check whether the file system is write-protected or check the size of the file system, and then execute "Create Configuration Information File" from the performance management window.

swsag0669

Unable to read a config XML file {0}. The contents of the file may be incorrect.

Explanation

This message indicates that the configuration information file for the device subject to performance monitoring could not be read. The configuration information file may not exist or may contain an error.

Parameters

{0} : Name of configuration information file

System action

Interrupts the processing.

System administrator response

Execute "Create Configuration Information File" from the performance management window.

swsag0670

Unable to write a config XML file {0}. Please check write permission of the filesystem or the capacity of the filesystem.

Explanation

This message indicates that a configuration information file could not be created because an error occurred while device configuration information required for device tree-view display was being saved to a file.

Parameters

{0} : Name of configuration information file

System action

Interrupts the processing.

System administrator response

Check whether the file system is write-protected or check the size of the file system, and then execute "Create Configuration Information File" from the performance management window.

swsag0671

Unable to find a performance data file {0}.

Explanation

This message indicates that the performance information file required for displaying a performance graph was not found. A performance information file is not created when performance monitoring is not performed. So, this message does not indicate an error if a performance information file is not found when an attempt is made to display performance information while performance monitoring is not being performed. If a performance information file is not found even when performance monitoring is being performed, the file system may be write-protected or may not have sufficient free space.

Parameters

{0} : Name of performance information file

System action

Continues the processing.

System administrator response

None

swsag0672

Unable to create a performance data file {0}. Please check write permission of the filesystem or the capacity of the filesystem.

Explanation

This message indicates that a performance information file could not be created during performance monitoring and performance information obtained from the device subject to performance monitoring could not be saved.

Parameters

{0} : Name of performance information file

System action

Interrupts performance monitoring.

System administrator response

Check whether the file system is write-protected or check the size of the file system, and then restart performance monitoring from "Set Performance Monitoring".

swsag0674

Unable to read a performance data file {0}. The contents of the file may be incorrect.

Explanation

This message indicates that the performance information file could not be read during displaying a performance graph. The performance information file may contain an error.

Parameters

{0} : Name of performance information file

System action

Interrupts performance graph display.

System administrator response

If a performance information file that may not be read successfully exists, performance cannot be graphed. Delete the performance information file or move it to another location.

For information on the performance information file that cannot be read, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

swsag0675

Unable to write a performance data file {0}. Please check write permission of the filesystem or the capacity of the filesystem.

Explanation

This message indicates that the performance information obtained from the device subject to performance monitoring could not be saved to the performance information file during performance monitoring.

Parameters

{0} : Name of performance information file

System action

Interrupts performance monitoring.

System administrator response

Check whether the file system is write-protected or check the size of the file system, and then restart performance monitoring from "Set Performance Monitoring".

swsag0676

A device {0} is not supported the representational function in the performance window.

Explanation

The performance management function does not support the display function at the performance management window for the specified device.

Parameters

{0} =Device name (IP address of target device)

System action

Interrupts the processing.

System administrator response

Check that the correct device is specified.

Check whether the performance management function supports the display function at the performance management window for the specified device.

For details on how to check whether the performance management function supports the display function at the performance management window for the specified device, refer to the " ETERNUS SF Storage Cruiser User's Guide", section "Overview" > "Summary of Each Function" > "1.3.7 Support Levels".

If this does not solve the problem, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

swsag0677

A device {0} is not supported performance monitoring.

Explanation

This message indicates that the specified device cannot be used in the performance management window because the device does not support the performance monitoring function.

Parameters

{0} : IP address of the target device

System action

Interrupts the processing.

System administrator response

Check whether the device specification is correct.

Check whether the specified device supports the performance monitoring function. For details, refer to the "ETERNUS SF Storage Cruiser User's Guide", section "Overview" > "Summary of Each Function" > "1.3.7 Support levels".

If this fails to solve the problem, collect the data required for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag0678

A device (class {0}) is not supported by this program

Explanation

This message indicates that the specified device is not supported for the performance management window.

Parameters

{0} : Name of the class file to be loaded to control the specified device

System action

Interrupts the processing.

System administrator response

Check whether the device specification is correct.

If this fails to solve the problem, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

swsag0679

An unexpected error occurred.

Explanation

This message indicates that an unexpected error such as a program internal error occurred.

System action

Interrupts the processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag0680

The device {0} is under threshold monitoring. Please stop the threshold

monitoring first and stop the performance monitoring.

Explanation

The device is under threshold monitoring.

Parameters

{0} : IP address of the target device

System action

Interrupts the processing.

System administrator response

Stop threshold monitoring and then stop performance monitoring.

swsag0681

The LogicalVolume within specified range does not exist.

Explanation

LogicalVolume does not exist within the range (minimum LUN_V to maximum LUN_V) input on the Performance Management dialog.

System action

Interrupts the processing.

System administrator response

Specify the range within which LogicalVolume exists.

When changes were made on the device configuration, execute "configuration
information file creation" and update the configuration file.
After these procedures, specify the range including LogicalVolume.

swsag0682

The definition file has been reloaded.

Explanation

The performance control function definition file perf.conf has been reloaded.

System action

The performance control function definition file perf.conf has been reloaded and reflected dynamically.

System administrator response

None

swsag0683

It failed on the reload of the definition file.

Explanation

The performance control function defition file perf.conf has failed.

System action

Interrupts the processing

System administrator response

Follow the detailed messages.

If detailed messages are not displayed, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

swsag0690

Unable to login a device {0}. Login name or password is incorrect.

Explanation

This message indicates that an attempt was made to login to the target device to set performance monitoring for the device or read the configuration information but failed because an invalid login name or password was specified.

Parameters

{0} : IP address of the target device

System action

Interrupts the processing.

System administrator response

Check the login name or password set in the target device. Alternatively, check the login name or password of the registered target device.

swsag0691

Unable to login a device {0}. Another user has a login session from {1}.

Explanation

This message indicates that an attempt was made to login to the target device to set performance monitoring for the device or to read the configuration information but failed because another user has already logged into the device.

Parameters

{0} : IP address of the target device
{1} : IP address of the server node that logged into the target device

System action

Under performance monitoring, retries processing until another login ends so that the processing can continue. In other cases, interrupts the processing.

System administrator response

Log out the process that logged into the target device and then re-execute the processing. Under performance monitoring, processing is automatically re-executed.

swsag0692

A communication error occurred with a device {0}. Please check the device.

Explanation

This message indicates that an error occurred during command processing for the target device for setting performance monitoring or reading configuration information.

Parameters

{0} : IP address of the target device

System action

Interrupts the processing.

System administrator response

Check the target device for errors, and then re-execute the processing.

If this fails to solve the problem, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

swsag0693

Unable to login a GRSC {1} managing a device {0}. Login name or password is incorrect.

Explanation

This message indicates that an attempt to login to GRSC to set performance monitoring for the target device, or to read the configuration information, failed because an invalid login name or password was specified.

Parameters

{0} : IP address of the target device
{1} : IP address of GRSC that manages the target device

System action

Interrupts the processing.

System administrator response

Check the settings for the GRSC or target device. Alternatively, check the login name or password of the registered target device.

swsag0694

Unable to login a GRSC {1} managing a device {0}. Another user has a login session.

Explanation

This message indicates that an attempt to login to GRSC to set performance monitoring for the target device, or to read the configuration information, failed because another user had already logged into the device.

Parameters

{0} : IP address of the target device
{1} : IP address of GRSC that manages the target device

System action

Under performance monitoring, processing is retried until another login ends, after which the processing continues. In other cases, the processing is interrupted.

System administrator response

Log out the process that logged into the GRSC managing the target device and then re-execute the processing. Under performance monitoring, processing is automatically re-executed.

swsag0695

A user '{2}' on a GRSC '{1}' managing a device {0} not authorized to set up the device."

Explanation

This message indicates that the specified login name cannot be used to set performance monitoring for the device because it does not have setting authority for the device.

Parameters

{0} : IP address of the target device
{1} : IP address of GRSC that manages the target device
{2} : Specified login name

System action

Interrupts the processing.

System administrator response

Check the GRSC settings. Alternatively, check the login name or password of the registered target device.

swsag0696

Unable to access to a device {0} with a GRSC {1}. The device {0} is not managed by the GRSC.

Explanation

This message indicates that an attempt was made to access a GR series RAID device via GRSC but the GRSC does not manage the GR series RAID device.

Parameters

{0} : IP address of the target device
{1} : IP address of GRSC that manages the target device

System action

Interrupts the processing.

System administrator response

Check the GRSC settings. Alternatively, check the URL address of the registered target device.

swsag0697

A communication error occurred with a GRSC {1} managing a device {0}. Please check the device or the GRSC.

Explanation

This message indicates that an attempt to set performance monitoring for a GR series RAID device managed by GRSC or to read configuration information on the device failed because an error occurred during command processing for the GRSC.

Parameters

{0} : IP address of the target device
{1} : IP address of GRSC that manages the target device

System action

Interrupts the processing.

System administrator response

Check the target device for errors, and then re-execute the processing.

If this fails to solve the problem, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

swsag0699

CM Command '{0}' Failed. Please check the device.

Explanation

This message indicates that an attempt to set performance monitoring for a GR series RAID device or to read configuration information on the device failed because CM command execution failed.

Parameters

{0} : Name of the CM command to be executed

System action

Interrupts the processing.

System administrator response

Check the target device for errors, and then re-execute the processing.

If this fails to solve the problem, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

swsag0700

Internal Program error occurred.

Explanation

An internal program error was detected.

System action

Interrupts system processing.

System administrator response

Contact your Fujitsu systems engineer.

swsag0701

SNMP error occurred in bridge communication.

Explanation

An SNMP error occurred during communication with the bridge.

System action

None

System administrator response

In some cases, the community name of a device such as fibre channel switch that uses the SNMP protocol for communication may be set to something other than "public" and the community name of the admin server may not be changed. If so, communication is disabled because of a mismatch of the community name. The community name of the target device needs to be set for the admin server.

Set the community name by referring to the "SNMP_COMMUNITY_NAME_FOR_IP" parameter provided in "C.2 sanma.conf Parameter" in the ETERNUS SF Storage Cruiser User's Guide, and reflect the contents of the setting file on this software.

If the problem persists even after checking the above environment settings, collect the data required for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag0702

Socket error occurred in bridge communication.

Explanation

A socket error occurred during communication with the bridge.

System action

None

System administrator response

Contact your Fujitsu systems engineer.

swsag0703

Unable to find selected bridge.

Explanation

The specified bridge was not found.

System action

None

System administrator response

Check the specified device.

In some cases, the community name of a device such as fibre channel switch that uses the SNMP protocol for communication may be set to something other than "public" and the community name of the admin server may not be changed. If so, communication is disabled because of a mismatch of the community name. The community name of the target device needs to be set for the admin server.

Set the community name by referring to the "SNMP_COMMUNITY_NAME_FOR_IP" parameter provided in "C.2 sanma.conf Parameter" in the ETERNUS SF Storage Cruiser User's Guide, and reflect the contents of the setting file on this software.

If the problem persists even after checking the above environment settings, collect the data required for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag0704

Network I/O Error on bridge communication.

Explanation

An I/O error occurred during communication with the bridge..

System action

None

System administrator response

In some cases, the community name of a device such as fibre channel switch that uses the SNMP protocol for communication may be set to something other than "public" and the community name of the admin server may not be changed. If so, communication is disabled because of a mismatch of the community name. The community name of the target device needs to be set for the admin server.

Set the community name by referring to the "SNMP_COMMUNITY_NAME_FOR_IP" parameter provided in "C.2 sanma.conf Parameter" in the ETERNUS SF Storage Cruiser User's Guide, and reflect the contents of the setting file on this software.

If the problem persists even after checking the above environment settings, collect the data required for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag0705

No response from bridge.

Explanation

A required bridge was not found.

System action

None

System administrator response

Check the target device.

In some cases, the community name of a device such as fibre channel switch that uses the SNMP protocol for communication may be set to something other than "public" and the community name of the admin server may not be changed. If so, communication is disabled because of a mismatch of the community name. The community name of the target device needs to be set for the admin server.

Set the community name by referring to the "SNMP_COMMUNITY_NAME_FOR_IP" parameter provided in "C.2 sanma.conf Parameter" in the ETERNUS SF Storage Cruiser User's Guide, and reflect the contents of the setting file on this software.

If the problem persists even after checking the above environment settings, collect the data required for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag0706

User Name or Password is incorrect for bridge. Device:

Explanation

An attempt to login to the bridge failed. The user name or password is invalid.

System action

None

System administrator response

None

swsag0707

Another user has logged into bridge. Logout and run function again. Device:

Explanation

Another user has already logged into the bridge. Log out the user and then re-execute.

System action

None

System administrator response

None

swsag0708

Parse error on telnet for bridge.

Explanation

Analysis of the execution results of the TELNET command issued to the bridge failed.

System action

None

System administrator response

None

swsag0709

A wrong point was detected in SCSI Cable connected to Bridge.

Explanation

An error was detected on the SCSI cable connected to the bridge.

System action

None

System administrator response

Contact your Fujitsu systems engineer.

swsag2020

Are you sure you want to register this device?

Explanation

The selected device will be added to the management server.

System action

None

System administrator response

None

swsag2022

The device has been registered.

Explanation

Registering of the device on the administrative server ended normally.

System action

None

System administrator response

None

swsag2023

The user name or password cannot be changed.

Explanation

The account information on the registered device could not be updated.

System action

None

System administrator response

None

swsag2024

Are you sure you want to configure SNMP traps on this device?

Explanation

A device, for which SNMP trap is not set, will be set as an SNMP trap destination so that the device can be managed by the Manager.

System action

None

System administrator response

None

swsag2040

Are you sure you want to delete xxxxx?

Explanation

Target device xxxxx will be excluded from management.

Parameters

xxxxxx : Device name for a server node, system name for a switch, system name for a storage

System action

None

System administrator response

None

swsag2041

xxxxxxx has been deleted.

Explanation

Device xxxxxx has been excluded from management.

Parameters

xxxxxx : Device name for a server node, system name for a switch, system name for a storage

System action

None

System administrator response

None

swsag2042

All access paths to xxxxx will be deleted.

Explanation

The access paths set for device xxxxxx are deleted.

Parameters

xxxxxx : Device name for a server node, system name for a storage

System action

None

System administrator response

None

swsag2043

The device is in the 'normal' state. Are you sure you want to delete it?

Explanation

A device in the normal state will be deleted.

System action

None

System administrator response

None

swsag2060

Enter a network address for device search.

Explanation

Enter the network address (IP address) of the device to be searched for.

System action

None

System administrator response

None

swsag2061

xxxxx devices were found.

Explanation

The device with IP address xxx.xxx.xxx.xxx was found.

Parameters

xxx.xxx.xxx.xxx : IP address

System action

None

System administrator response

None

swsag2083

Are you sure you want to create the access path using the above settings?

Explanation

An access path will be set as shown in the window.

System action

None

System administrator response

None

swsag2084

The access path has been created.

Explanation

The access path has been set normally. To use the set access path, the server node storage must be rebooted.

System action

None

System administrator response

None

swsag2085

Select devices to be shown.

Explanation

Select the server node or storage for which an access path is to be set.

System action

None

System administrator response

None

swsag2086

There are no devices that can be shown.

Explanation

There is no storage device for which an access path is to be set.

System action

None

System administrator response

None

swsag2087

The WWPN for xxxxx has been changed to yyyyy. Do you want to proceed with the access path auto-reset?

Explanation

WWPN of xxxxx was changed to WWPN HBA of yyyyy. Confirm whether or not to change the previously set access path for WWPN to the xxxxx HBA.

Parameters

xxxxx : Device name
yyyyy : Device name

System action

None

System administrator response

None

swsag2088

Access path inheritance has been completed.

Explanation

The configuration information for the access path that was set for the old HBA/FC port was set to the specified HBA/FC port and processing for inheriting the access path configuration information has been completed.

System action

None

System administrator response

None

swsag2090

Select devices to be hidden.

Explanation

Select a device to be deleted from those displayed in the window.

System action

None

System administrator response

None

swsag2091

There are no devices that can be hidden.

Explanation

There are no devices that can be deleted.

System action

None

System administrator response

None

swsag2100

Are you sure you want to delete the access path?

Explanation

The access path setting will be deleted.

System action

None

System administrator response

None

swsag2101

The access path has been deleted.

Explanation

Deletion of the access path setting has completed normally.

System action

None

System administrator response

None

swsag2120

Are you sure you want to use the following LUN for access path diagnosis?

Explanation

Access path diagnosis will be executed using the specified LUN.

System action

None

System administrator response

None

swsag2140

The URL is invalid.

Explanation

The specified URL address is not found.

System action

None

System administrator response

None

swsag2141

The Help URL is invalid.

Explanation

The specified HELP URL address is not found.

System action

None

System administrator response

None

swsag2142

The path is invalid.

Explanation

It was not possible to execute the application which registered as management software because it was not found. Please confirm the registered information.

System action

None

System administrator response

None

swsag2160

A status change has been detected. Are you sure you want to update the administrative server status information?

Explanation

Because a change in the device information was detected, the current status display will be updated to reflect the latest information.

System action

None

System administrator response

None

swsag2161

When the operation completes, select "Refresh" from the "View" menu.

Explanation

Upon the completion of the current operation, select "Refresh" from the menu options to update the display with the operation results.

System action

None

System administrator response

None

swsag2165

The device name has already been registered. Please enter a different name.

Explanation

The name specified for the new name of the device cannot be used because that name has already been registered for another device in the database. Specify another device name.

System action

None

System administrator response

None

swsag2166

A name must be entered for device registration.

Explanation

Processing for changing the device name cannot be continued because no device name is specified. Specify a device name to continue the processing for changing the device name.

System action

None

System administrator response

None

swsag2167

The device name must be 24 characters or less.

Explanation

The specified device name consists of over 24 characters. As for RAID devices, GR series and ETERNUS series, specify the device name consisting of below 24 characters and execute the procedure to change the name.

System action

None

System administrator response

Specify the device name that consists of below 24 characters.

swsag2180

Icon positions have been saved.

Explanation

Icon position setting data has been saved successfully.

System action

None

System administrator response

None

swsag2181

The notes will be saved. Are you sure you want to save the notes?

Explanation

This message confirms the update of the memo information because a change was found in the notepad information.

System action

None

System administrator response

None

swsag2182

The notes have been saved.

Explanation

The notepad information has been saved successfully.

System action

None

System administrator response

None

swsag2183

Are you sure you want to save the notes?

Explanation

Confirm whether or not to update the memo information because a change was found in the notepad information.

System action

None

System administrator response

None

swsag2184

Are you sure you want to change the management software location?

Explanation

Confirm whether or not to continue to change management software information.

System action

None

System administrator response

None

swsag2185

The notes have been edited but not saved. Are you sure you want to close the properties window?

Explanation

The property was about to be ended with the note pad in the property edited. Please end the property after executing "Save Notepad" of the note pad when you want to save edited note pad information.

System action

None

System administrator response

None

swsag2201

Error code list for SAN GUI Control could not be developed.

Explanation

The error code file (GuiCtrlErrCode.csv) for GUI control does not exist, the file data is invalid, or a fatal error occurred during data loading.

System action

Interrupts the processing.

System administrator response

Collect the data required for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag2202

SANMA GUI MODEL could not be initialized.

Explanation

Initialization of the SANMA GUI MODEL failed because of a CIM interface error.

System action

Interrupts the processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag2203

SANMA GUI MODEL has not been initialized.

Explanation

The SANMA GUI MODEL has not been initialized because of an error in the interface with CIM.

System action

Interrupts the processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag2207

Failed to initialize the Storage Cruiser(control module).

Explanation

The client GUI control module could not be initialized because client GUI configuration information could not be read.

System action

Interrupts the processing.

System administrator response

If message java.rmi.RemoteException is output as a detail message, probably the RMI is not started. Please restart this software.

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag2208

Failed to initialize the Storage Cruiser.

Explanation

The client GUI display could not be initialized because illegal processing was detected during the initialization of the client GUI display system.

System action

Interrupts the processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag2209

An internal program inconsistency was detected.

Explanation

An access path is not set. Therefore, the data to be displayed in the table information could not be initialized.

System action

Interrupts the processing.

System administrator response

None

swsag2261

Please enter an IP address or name to search for.

Explanation

Information to search the device isn't input. Please input search condition and search it again.

System action

None

System administrator response

None

swsag2280

Select the icons of the HBA and FC port to be linked by an access path.

Explanation

Select and execute both icons of the HBA and CA for which access paths are to be set.

System action

Interrupts the processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag2281

Select the HBA and FC port to be linked by an access path.

Explanation

Select and execute both icons of the HBA and CA for which access paths are to be set.

System action

Interrupts the processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag2284

Enter a number between 0 and 255.
Enter a number between 0 and 511.
Enter a number between 0 and 1023.

Explanation

Enter a number from 0 to 255 to make the setting.
Enter a number from 0 and 511 to make the setting.
Enter a number from 0 and 1023 to make the setting.

System action

None.

System administrator response

Please input the LUN information.

swsag2285

No LUN has been configured.

Explanation

A required LUN was not specified.

System action

None

System administrator response

Enter LUN information.

swsag2286

The HBA/FC port to status is other than "changed" so it cannot be automatically reset.

Explanation

The status of the relevant HBA is other than "changed" and cannot be automatically re-set.

System action

Interrupts the processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag2287

An HBA icon must be selected.

Explanation

No HBA icon is selected.

System action

Interrupts the processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag2288

Affinity group 0 has not been configured.

Explanation

AffinityGroup 0 has not been set.

System action

Interrupts the processing.

System administrator response

Configure AffinityGroup0 in the disk array and reexecute.

If AffinityGroup0 already exists, collect the data required for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag2289

The specified Target ID is already in use. Enter another Target ID.

Explanation

The specified Target ID is already set. Specify another Target ID.

System action

Interrupts the processing.

System administrator response

Specify another Target ID.

swsag2290

Unexpected exception was detected.

Explanation

A client GUI internal error or a SAN configuration error was detected.

System action

Interrupts the processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag2293

The LUN mapping for the access path is not defined.

Explanation

The access paths cannot be set because LUNMapping information has not been specified for CA ports with security off.

System action

Interrupts the processing.

System administrator response

Configure LUNMapping for the CA port with security off, for which an access path is to be set in the disk array.

swsag2294

The affinity group for the access path is not defined.

Explanation

The access paths cannot be set because AffinityGroup information has not been specified for CA ports with security on.

System action

Interrupts the processing.

System administrator response

Configure AffinityGroup in the disk array and re-execute.

swsag2295

A remote CA was chosen when trying to create an access path.

Explanation

CA port which was going to perform an access path setup cannot perform an access path setup because of Remote CA.

System action

Interrupts the processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "Operation" > "Access Path Management" > "Access path setting", then contact your Fujitsu systems engineer (SE).

swsag2296

The access paths of two registered devices in the domain cannot be connected to each other.

Explanation

The access paths of two registered devices in the domain cannot be connected to each other.

System action

Interrupts the processing.

System administrator response

None

swsag2297

The access paths created during provisioning cannot be deleted.

Explanation

The access paths that are connected by the provisioning operation cannot be deleted.

System action

Interrupts the processing.

System administrator response

None

swsag2298

An access path cannot be created using the selected FC port.

Explanation

An access path to the selected port cannot be set up.

System action

Interrupts the processing.

System administrator response

Confirm the type of port for which you want to set the access path.
A CA that is assigned to an ETERNUS VD800 transaction server cannot be connected to an access path.
The FC port that the FC-Initiator type is set cannot be connected to an access path.

swsag2301

You attempted to delete an access path that was not a WWPN connection.

Explanation

An attempt was made to delete an access path other than WWPN BINDING (WWPN connection).

System action

Interrupts the processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag2302

An HBA and FC port were selected that are not connected by an access path.

Explanation

Select and execute both icons of the HBA and CA for which access paths are to be set.

System action

Interrupts the processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag2304

Select the HBA and FC port of the access path to be deleted.

Explanation

Select the HBA and CA for which access paths are set.

System action

Interrupts the processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag2305

Select the HBA and FC port icons of the access path to be deleted.

Explanation

Select the HBA and FC port for which access paths are set.

System action

Interrupts the processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag2320

No access path has been configured.

Explanation

No access paths have been set.

System action

Interrupts the processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag2321

Access path diagnosis is disabled (Under Solaris, diagnosis can only be performed on an access path with WWPN_Zoning).

Explanation

The selected access path cannot be diagnosed because it was set by switch zoning (Another Binding).

System action

Interrupts the processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag2322

A monitoring or device status error was detected for the selected HBA or FC port.

Explanation

The status of the HBA or CA of the selected access path is other than "OK."

System action

Interrupts the processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag2323

Select the HBA and FC port that have an access path configured.

Explanation

Select the HBA and CA for which access paths are set.

System action

Interrupts the processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag2324

Select the HBA and FC port icons on which the diagnosis should be performed.

Explanation

Select the icon for the access path to be diagnosed or the icons for the HBA and CA for which access paths are set.

System action

Interrupts the processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag2325

Access path diagnosis is disabled (because a Target ID has not been configured for the selected access path).

Explanation

An attempt was made to diagnose an access path for which no Target ID was set.

System action

Interrupts the processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag2326

Diagnosis cannot be performed because the LUN to be diagnosed has not been entered.

Explanation

Access path diagnosis has been interrupted because LUN information was not entered.

System action

Interrupts the processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag2327

Access path diagnosis is disabled (because diagnosis cannot be performed on a tape device).

Explanation

Access path diagnosis has been interrupted because an attempt was made to diagnose a tape device access path.

System action

Interrupts the processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag2380

Input parameter error was deleted from SAN manager GUI.

Explanation

An invalid value was specified.

System action

Interrupts the processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag2381

Error detected in format of message information data.

Explanation

The format of the message code data used for internal processing was invalid.

System action

Interrupts the processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag2382

Null information was received.

Explanation

Null data was received as a response to the processing.

System action

Interrupts the processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag2383

Null object was assigned.

Explanation

Null information was included in a parameter specified for processing.

System action

Interrupts the processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag2385

Can not find file.

Explanation

The message code file or error code file cannot be obtained.

System action

Interrupts the processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag2386

Input-Output error.

Explanation

An error occurred while reading or writting a file in Client.

System action

Interrupts the processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag2391

Could not save icon positions.

Explanation

Icon position data could not be saved.

System action

None

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag2392

The search has completed. There are no more devices to be found.

Explanation

Information was searched for based on the specified search conditions but no relevant information was found.

System action

None

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag2393

Please enter a term to search for.

Explanation

Enter the search conditions.

System action

None

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag2394

An area overflow that could affect the Storage Cruiser GUI was detected.

Explanation

An error occurred because the GUI display area defined by Java overflowed.

System action

None

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag2395

An unexpected error occurred. Please try the operation again and check the result.

Explanation

A processing error or an unexpected error was detected. Perform the same operation again to check the processing.

System action

None

System administrator response

  • When this is output following an operation in the "Eco-mode information and set" window

    If the window is not displayed when the [ECO-mode information and set] tab is selected in the ETERNUS storage device property display, verify that the target storage device supports the Eco-mode.

    If the target storage device supports the Eco-mode and the information is still not displayed, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

  • Other case

    Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag2396

The selected device is not being performance monitored.

Explanation

An error occurred because an attempt was made to make performance settings for a device that does not support performance management.

System action

None

System administrator response

None

swsag2398

There is no default browser registered with operating system.

Explanation

URL information could not be displayed because the Web browser used to reference URL information is not installed or registered.

System action

Interrupts web display.

System administrator response

Check the Web browser environment of the PC with the client installed.

swsag2507

Select an available port and then the device that it will be connected to.

Explanation

To automatically register the detected FC and SCSI ports during manual embedding, select the FC and SCSI ports to be registered and the registration destination device.

System action

None

System administrator response

None

swsag2515

Do you want to update the administrative server with the latest information?

Explanation

Information was edited on the Manual Configuration window. Please update the management information of client.

System action

None

System administrator response

None

swsag2600

The device cannot be registered until all mandatory fields are completed.

Explanation

Information required for manual embedding has not been entered.

System action

None

System administrator response

Enter the data for the items required for manual embedding.

swsag2601

Please enter the required information then try again.

Explanation

Information required for manual embedding has not been entered.

System action

None

System administrator response

Enter the data for the items required for manual embedding.

swsag2602

The device name is the same as one already registered with the administrative server. Please enter a device name other than xxxxxx.

Explanation

The registration name specified for manual embedding is already being used. Enter another name for registration.

System action

None

System administrator response

Specify another device name.

swsag2603

A device with this SCSI ID or LUN has already been registered.

Explanation

The SCSI ID or LUN specified for manual embedding is already being used. Specify another SCSI ID or LUN to register it.

System action

None

System administrator response

The specified information may have already been defined. Check the system information and enter valid information.

swsag2604

Enter a bridge device name.

Explanation

A bridge device name has not been entered for manual embedding.

System action

None

System administrator response

None

swsag2605

Enter the number of SCSI buses for this bridge.

Explanation

The number of SCSI buses has not been entered for manual embedding.

System action

None

System administrator response

None

swsag2606

Enter a numerical value for the number of SCSI buses.

Explanation

The number of SCSI buses has not been entered in numeric format for manual embedding.

System action

None

System administrator response

None

swsag2607

A physical line already exists between the ports.

Explanation

During manual embedding, an attempt was made to connect a physical line to a port to which a physical line is already connected.

System action

None

System administrator response

Check whether a physical line has already been connected to the port to which a physical line is to be connected.

swsag2608

A physical line already exists for the hub port.

Explanation

During manual embedding, an attempt was made to connect an end of a physical line to a hub port to which a physical line is already connected.

System action

None

System administrator response

Check whether an end of a physical line has already been connected to the hub port to which a physical line is to be connected.

swsag2609

A physical line already exists between the hubs.

Explanation

During manual embedding, an attempt was made to connect both ends of a physical line to hub ports to each of which a physical line is already connected.

System action

None

System administrator response

Check whether a physical line has already been connected to each of the hub ports to each of which each end of a physical line is to be connected.

swsag2611

A physical line already exists between the routers.

Explanation

A physical line has already existed between devices though it tried to connect the port of the router device with the port of other devices on the Manual Configuration window.

System action

None

System administrator response

None

swsag2612

A physical line already exists for the router FC port.

Explanation

A physical line has already existed between the FC port of the device though it tried to connect between the ports of the two router devices on the Manual Configuration window.

System action

None

System administrator response

None

swsag2613

Please use a value less than or equal to 65534 for the controller number.

Explanation

Please set up a controller number of HBA for 65534 or less numerical value.

System action

None

System administrator response

None

swsag2614

Please use a value less than or equal to 65534 for the group number.

Explanation

Please set up a group number of CA or SCSI-CA for 65534 or less numerical value.

System action

None

System administrator response

None

swsag2615

Please use a value less than or equal to 65534 for the exchange unit number.

Explanation

Please set up an exchange unit number of CA or SCSI-CA for 65534 or less numerical value.

System action

None

System administrator response

None

swsag2616

Please use a value less than or equal to 65534 for the port.

Explanation

Please set up a port number of CA or SCSI-CA for 65534 or less numerical value.

System action

None

System administrator response

None

swsag2617

Comma ',' and backslash '\' characters cannot be used in manual embedding device names.

Explanation

Comma (,) and backing slash (\) cannot be used for the device name needed when a new device is registered on the Manual Configuration window.

System action

None

System administrator response

None

swsag2618

A device with the entered IP address could not be found. Please check that the IP address is correct.
An LT130 device with the entered IP address could not be found. Please check that the IP address is correct.
A built-in bridge 0 with the entered IP address could not be found. Please check that the IP address is correct.
A built-in bridge 1 with the entered IP address could not be found. Please check that the IP address is correct.

Explanation

IP address input by the device making does not exist in the network or the form of input IP address is wrong. Please input correct IP address after confirming to the Manager.

System action

None

System administrator response

In some cases, the community name of a device such as fibre channel switch that uses the SNMP protocol for communication may be set to something other than "public" and the community name of the admin server may not be changed. If so, communication is disabled because of a mismatch of the community name. The community name of the target device needs to be set for the admin server.

Set the community name by referring to the "SNMP_COMMUNITY_NAME_FOR_IP" parameter provided in "C.2 sanma.conf Parameter" in the ETERNUS SF Storage Cruiser User's Guide, and reflect the contents of the setting file on this software.

If the problem persists even after checking the above environment settings, collect the data required for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag2619

A device name must consist of more than just space characters. Please also use other characters in the device name.

Explanation

In the device making operation, input device names are all blank.

Please decide the device name by using characters other than the blank.

System action

None

System administrator response

None

swsag2620

Manual configuration window is started. Please close the manual configuration window before attempting this action.

Explanation

When the manual operation built-in window is started, switching windows by using a tab operation is inhibited. To switch to the logic resource management window, first close the manual embedding window, then select the tab item for switching to the logic resource management window.

System action

None

System administrator response

None

swsag2700

Please enter a numerical value in the range 1-1000.

Explanation

Please input the numerical value to 1-1000 when setting the number of lines displayed on SystemEvent.

System action

None

System administrator response

None

swsag3003

Failed.

Explanation

An OpenCIMOM internal error was detected.

System action

None

System administrator response

Possible reasons for this message being output are as follows:

  • The OpenCIMOM daemon being used failed or was restarted.

    OpenCIMOM is restarted in instances such as when the OS on the administrative server is restated or when cluster switching occurs on the administrative server.
    Check whether OpenCIMOM is active. If OpenCIMON is down, restart it in accordance with the description in "Chapter 12 Command References" in the ETERNUS SF Storage Cruiser User's Guide.

  • The CIM data area is full.

    Check whether the disk is full by the following method.

    Platform of Manager

    How to check

    Windows

    Confirm the property information of the disk where CIM data base is stored.

    Solaris OS,
    Linux

    Use the "df -k /var/opt/FJSVssmgr/current/opencimom/logr" command.

    If the disk is full, take appropriate measures to ensure that the required free space can be reserved on the disk, and then restart the OpenCIMOM daemon (refer to "Chapter 12 Command References" in the ETERNUS SF Storage Cruiser User's Guide).

If the command or service confirms that OpenCIMOM is active or after OpenCIMOM is restarted, close the client management window and then reopen it.

If no error can be found by the above operations, other causes must be assumed.

Collect the data required for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag3006

An invalid parameter is passed to a method.

Explanation

An OpenCIMOM internal error was detected.

System action

None

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag3007

An invalid class is specified.

Explanation

An OpenCIMOM internal error was detected.

System action

None

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag3008

The specified element cannot be found.

Explanation

An OpenCIMOM internal error was detected.

System action

None

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag3009

The specified element already exists.

Explanation

An OpenCIMOM internal error was detected.

System action

None

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag3013

The memory is low.

Explanation

An OpenCIMOM internal error was detected.

System action

None

System administrator response

Restart the OpenCIMOM daemon and restart this software.

If this fails to solve the problem, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

swsag3101

unable to find the equipment/adapter.

Explanation

A required device or adapter is not found.

System action

None

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag3103

no such association.

Explanation

The specified association is not found.

System action

None

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag3106

failed to serialize the object.

Explanation

Object serialization failed.

System action

None

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag3107

failed to create a new instance.

Explanation

Instance generation failed.

System action

None

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag4101

%MPType% access path(%MPAccessPath%) fault in %SystemName%(%OSName%%OSVersion%[%IPAddress%]).

Explanation

A path was blocked during server node multipath disk control. The system is degraded.

Parameters

%MPType% : Type of multipath disk control
%MPAccessPath% : Access path name
%SystemName% : Server node name
%OSName% : OS name
%OSVersion% : OS version
%IPAddress% : IP address

System action

None

System administrator response

Take corrective measures on the server node for multipath disk control errors on the server node.

swsag4102

%MPType% access path(%MPAccessPath%) fault and no more path in %SystemName%(%OSName%%OSVersion%[%IPAddress%]).

Explanation

All paths have been blocked under server node multipath control.

Parameters

%MPType% : Type of multipath disk control
%MPAccessPath% : Access path name
%SystemName% : Server node name
%OSName% : OS name
%OSVersion% : OS version
%IPAddress% : IP address

System action

None

System administrator response

Take appropriate corrective measures on the server node for any multipath disk control errors on the server node.

swsag4103

Some paths could not be detected in %SystemName%(%OSName%%OSVersion%[%IPAddress%]).

Explanation

Part of paths could not be detected on server node startup.
Multipath control operation could not be started normally.

Parameters

%SystemName% : Name of the server node
%OSName% : OS name
%OSVersion% : OS version
%IPAddress% : IP address

System action

None

System administrator response

This event occurs when a server node is started, and it may occur even if multipath disk control can be used normally after the startup is complete. After server node startup is complete, execute "Refresh" in the resource view and check the status of the server node.If this issue is not solved, take corrective measures on the server node for multipath disk control errors on the server node.

swsag4113

LMF fault in %SysName%(%OSName%%OSVersion%[%IPAddress%])

Explanation

An error occurred in the magnetic tape library device.

Parameters

%SysName% : SysName
%OSName : Name of administrative server node OS
%OSVersion% : Version of administrative server node OS
%IPAddress% : administrative server node IP address

System action

None

System administrator response

Contact your Fujitsu customer engineer (CE).

swsag4200

Central Memory FAULT in %SysName%(%ProductID%[%IPAddress%]).

Explanation

Self-diagnosis detected a central memory error in the Fibre Channel switch.

Parameters

%SysName% : SysName
%ProductID% : Device name
%IPAddress% : IP address

System action

None

System administrator response

Contact your Fujitsu customer engineer (CE).

swsag4201

Embedded Port FAULT in %SysName%(%ProductID%[%IPAddress%]).

Explanation

Self-diagnosis detected an embedded port error.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP address

System action

None

System administrator response

Contact your Fujitsu customer engineer (CE).

swsag4202

FC Port No.%PortNo% FAULT in %SysName%(%ProductID%[%IPAddress%]).

Explanation

A port failure was detected.

Parameters

%PortNo% : Port number
%SysName% : SysName
%ProductID% : Device name
%IPAddress% : IP address

System action

None

System administrator response

Contact your Fujitsu customer engineer (CE).

swsag4203

FC Port No.%PortNo% %Status% in %SysName%(%ProductID%[%IPAddress%]).

Explanation

The status change of the port was detected. This message is notified when the FC cable is pulled out and put in for instance.

Parameters

%PortNo% : Port number
%Status% : Port status(Online/Offline)
%SysName% : SysName
%ProductID% : Device name
%IPAddress% : IP address

System action

None

System administrator response

Please confirm connected situation of the FC cable. Please contact Fujitsu maintenance technology member(CE) when it is not solved by the problem.

If this fails to solve the problem, contact your Fujitsu customer engineer (CE).

swsag4204

Power Supply #%PSNo% FAULT in %SysName%(%ProductID%[%IPAddress%]).

Explanation

The power supply fault was detected.

Parameters

%PSNo% : Power supply unit number
%SysName% : SysName
%ProductID% : Device name
%IPAddress% : IP address

System action

None

System administrator response

Contact your Fujitsu customer engineer (CE).

swsag4205

Fan #%FanNo% FAULT in %SysName%(%ProductID%[%IPAddress%]).

Explanation

The fan unit fault was detected.

Parameters

%FanNo% : Fan unit number
%SysName% : SysName
%ProductID% : Device name
%IPAddress% : IP address

System action

None

System administrator response

Contact your Fujitsu customer engineer (CE).

swsag4207

Temp #%TempNo% FAULT in %SysName%(%ProductID%[%IPAddress%]).

Explanation

A thermal sensor failure was detected.

Parameters

%TempNo% : temperature sensor number
%SysName% : SysName
%ProductID% : device name
%IPAddress% : IP address

System action

None

System administrator response

Contact your Fujitsu customer engineer (CE).

swsag4209

%EventMessage% in %SysName(%ProductID%[%IPAddress%]).

Explanation

An event trap was detected. The unit trap message is output without any change.

Parameters

%EventMessage% : Event message
%SysName% : SysName
%ProductID% : Device name
%IPAddress% : IP address

System action

None

System administrator response

Please refer to the manual attached to the device. If this fails to solve the problem, contact your Fujitsu customer engineer (CE).

swsag4402

%ElementName%(%ItemId%) degraded in %SystemName%(%ProductID%[%IPAddress%]).

Explanation

A component failure was detected.

Parameters

%ElementName% : Element name
%ItemId% : Item ID
%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP address

System action

None

System administrator response

Contact your Fujitsu customer engineer (CE).

swsag4403

%ElementName(%ItemId%) expiration in %SystemName%(%ProductID%[%IPAddress%]).

Explanation

The battery requires replacement.

Parameters

%ElementName% : Element name
%ItemId% : Item ID
%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP address

System action

None

System administrator response

Contact your Fujitsu customer engineer (CE).

swsag4405

%partBrokenMessage% in %SysName%(%ProductID%[%IPAddress%])

Explanation

A possible failure was detected.

Parameters

%partBrokenMessage% : Possible failure content
%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP address

System action

None

System administrator response

Contact your Fujitsu customer engineer (CE).

swsag4406

%sensorStatusChangeMessage% in %SysName%(%ProductID%[%IPAddress%])

Explanation

State change of thermal sensor or voltage sensor was detected.

Parameters

%sensorStatusChangeMessage% : Content of change in state of sensor
%ProductID% : Device name
%IPAddress% : IP address

System action

None

System administrator response

Contact your Fujitsu customer engineer (CE).

swsag4407

%maintenanceInfo% in %SysName%(%ProductID%[%IPAddress%])

Explanation

Maintenance information was received.

Parameters

%maintenanceInfo% : Maintenance information
%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP address

System action

None

System administrator response

Contact your Fujitsu customer engineer (CE).

swsag4408

CM(%ItemId%) Warning(%PartsName%) in %SystemName%(%ProductID%[%IPAddress%]).

Explanation

CM Warning was detected.

Parameters

%ItemId% : Item ID of CM
%PartsName% : Part name
%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP address

System action

None

System administrator response

Contact your Fujitsu customer engineer (CE).

swsag4409

%automaticRestorationInfo% in %SysName%(%ProductID%[%IPAddress%]).

Explanation

Auto recovery notification was received.

Parameters

%automaticRestorationInfo% : Auto recovery information
%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP address

System action

None

System administrator response

This message is output when the abnormal status was released. It is no necessary to response.

swsag4410

Acute Event (REFCODE=%xxxxx% Parts=%yyyyy%) in %SystemName%(%ProductID%[%IPAddress%])

Explanation

A failure that causes the entire subsystem to stop was detected.

Parameters

%xxxxx% : Message code
%yyyyy% : Part code
%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP address

System action

None

System administrator response

Contact the Fujitsu customer engineer (CE) responsible for the device.

swsag4412

Serious Event (REFCODE=%xxxxx% Parts=%yyyyy%) in %SystemName%(%ProductID%[%IPAddress%])

Explanation

A failure that causes the failed part to stop was detected.

Parameters

%xxxxx% : Message code
%yyyyy% : Part code
%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP address

System action

None

System administrator response

Contact the Fujitsu customer engineer (CE) responsible for the device.

swsag4413

Moderate Event (REFCODE=%xxxxx% Parts=%yyyyy%) in %SystemName%(%ProductID%[%IPAddress%])

Explanation

A partial failure was detected.

Parameters

%xxxxx% : Message code
%yyyyy% : Part code
%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP address

System action

None

System administrator response

Contact the Fujitsu customer engineer (CE) responsible for the device.

swsag4414

Service Event (REFCODE=%xxxxx% Parts=%yyyyy%) in %SystemName%(%ProductID%[%IPAddress%])

Explanation

A minor failure was detected.

Parameters

%xxxxx% : Message code
%yyyyy% : Part code
%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP address

System action

None

System administrator response

Contact the Fujitsu customer engineer (CE) responsible for the device.

swsag4420

System down occurred in %SystemName%(%ProductID%[%IPAddress%])

Explanation

A local controller failure was detected.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP address

System action

None

System administrator response

Contact the Fujitsu customer engineer (CE) responsible for the device.

swsag4421

Drive blocking occurred in %SystemName%(%ProductID%[%IPAddress%])

Explanation

A data drive blockage was detected.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP address

System action

None

System administrator response

Contact the Fujitsu customer engineer (CE) responsible for the device.

swsag4422

Fan failure occurred in %SystemName%(%ProductID%[%IPAddress%])

Explanation

A fan alarm was detected.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP address

System action

None

System administrator response

Contact the Fujitsu customer engineer (CE) responsible for the device.

swsag4423

Power supply failure occurred in %SystemName%(%ProductID%[%IPAddress%])

Explanation

A DC power failure was detected.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP address

System action

None

System administrator response

Contact the Fujitsu customer engineer (CE) responsible for the device.

swsag4424

Battery failure occurred in %SystemName%(%ProductID%[%IPAddress%])

Explanation

A battery alarm was detected.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP address

System action

None

System administrator response

Contact the Fujitsu customer engineer (CE) responsible for the device.

swsag4425

Cache memory failure occurred in %SystemName%(%ProductID%[%IPAddress%])

Explanation

A cache memory blockage was detected.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP address

System action

None

System administrator response

Contact the Fujitsu customer engineer (CE) responsible for the device.

swsag4426

UPS failure occurred in %SystemName%(%ProductID%[%IPAddress%])

Explanation

A UPS alarm was detected.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP address

System action

None

System administrator response

Contact the Fujitsu customer engineer (CE) responsible for the device.

swsag4427

AC line or inbox failure occurred in %SysName%(%productID%[%IPAddress%])

Explanation

An Inbox Failure was detected.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP address

System action

None

System administrator response

Contact the Fujitsu customer engineer (CE) responsible for the device.

swsag4428

Cache backup circuit failure occurred in %SystemName%(%ProductID%[%IPAddress%])

Explanation

A battery charging circuit alarm was detected.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP address

System action

None

System administrator response

Contact the Fujitsu customer engineer (CE) responsible for the device.

swsag4429

Other controller failure occurred in %SystemName%(%ProductID%[%IPAddress%])

Explanation

A remote controller blockage was detected.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP address

System action

None

System administrator response

Contact the Fujitsu customer engineer (CE) responsible for the device.

swsag4430

Warning occurred in %SystemName%(%ProductID%[%IPAddress%])

Explanation

The warning status of the disk array was detected.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP address

System action

None

System administrator response

Contact the Fujitsu customer engineer (CE) responsible for the device.

swsag4431

Spare drive failure occurred in %SystemName%(%ProductID%[%IPAddress%])

Explanation

A spare drive blockage was detected.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP address

System action

None

System administrator response

Contact the Fujitsu customer engineer (CE) responsible for the device.

swsag4433

Enclosure controller failure occurred in %SystemName%(%ProductID%[%IPAddress%])

Explanation

An ENC alarm was detected.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP address

System action

None

System administrator response

Contact the Fujitsu customer engineer (CE) responsible for the device.

swsag4434

Loop failure occurred in %SystemName%(%ProductID%[%IPAddress%])

Explanation

A loop failure alarm was detected.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP address

System action

None

System administrator response

Contact the Fujitsu customer engineer (CE) responsible for the device.

swsag4440

%EventMessage% in %SystemName%(%ProductID%[%IPAddress%])

Explanation

An event message was detected.

Parameters

%EventMessage% : Message
%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP address

System action

None

System administrator response

Contact the Fujitsu customer engineer (CE) responsible for the device.

swsag4501

Library fault in %SysName%(%productID%[%IPAddress%])

Explanation

An alarm occurred in the magnetic tape library device.

Parameters

%SysName% : SysName
%productID% : Device name
%IPAddress% : IP address

System action

None

System administrator response

Contact your Fujitsu customer engineer (CE).

swsag4520

The media error occurred. (Barcode label: %value%) in %SysName%(%productID%[%IPAddress%])

Explanation

A drive media error was detected.

Parameters

%value% : Version and level
%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP address

System action

None

System administrator response

Contact your Fujitsu customer engineer (CE).

swsag4521

The drive unit%value% error occurred in %SysName%(%productID%[%IPAddress%])

Explanation

A drive error was detected.

Parameters

%value% : Unit number
%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP address

System action

None

System administrator response

Contact your Fujitsu customer engineer (CE).

swsag4522

The drive unit%value% became offline in %SysName%(%productID%[%IPAddress%])

Explanation

The drive went offline.

Parameters

%value% : Unit number
%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP address

System action

None

System administrator response

Check the state of the drive.

swsag4523

The drive unit%value% FAN alarm occurred in %SysName%(%productID%[%IPAddress%])

Explanation

A drive fan error was detected.

Parameters

%value% : Unit number
%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP address

System action

None

System administrator response

Contact your Fujitsu customer engineer (CE).

swsag4524

The drive unit%value% needs cleaning in %SysName%(%productID%[%IPAddress%])

Explanation

The drive needs cleaning.

Parameters

%value% : Unit number
%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP address

System action

None

System administrator response

Contact your Fujitsu customer engineer (CE).

swsag4525

The drive unit%value% Link Down occurred in %SysName%(%productID%[%IPAddress%])

Explanation

A drive link down occurred.

Parameters

%value% : Unit number
%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP address

System action

None

System administrator response

Contact your Fujitsu customer engineer (CE).

swsag4526

The adapter%value% error occurred in %SysName%(%productID%[%IPAddress%])

Explanation

A Fibre Channel port failure was detected.

Parameters

%value% : Unit number
%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP address

System action

None

System administrator response

Contact your Fujitsu customer engineer (CE).

swsag4527

The CM reader error or CM error in medium occurred in %SysName%(%productID%[%IPAddress%])

Explanation

The CM reader error or CM error in medium was detected.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP address

System action

None

System administrator response

Contact your Fujitsu customer engineer (CE).

swsag4528

The barcode reader error occurred in %SysName%(%productID%[%IPAddress%])

Explanation

A barcode reader failure was detected.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP address

System action

None

System administrator response

Contact your Fujitsu customer engineer (CE).

swsag4529

The CAS unit%value% error occurred in %SysName%(%productID%[%IPAddress%])

Explanation

A cartridge access station (CAS) failure was detected.

Parameters

%value% : Unit number
%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP address

System action

None

System administrator response

Contact your Fujitsu customer engineer (CE).

swsag4530

The battery unit error occurred in %SysName%(%productID%[%IPAddress%])

Explanation

A battery failure was detected.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP address

System action

None

System administrator response

Contact your Fujitsu customer engineer (CE).

swsag4531

The library FAN(1) error occurred in %SysName%(%productID%[%IPAddress%])

Explanation

A fan failure was detected.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP address

System action

None

System administrator response

Contact your Fujitsu customer engineer (CE).

swsag4532

The library FAN(2) error occurred in %SysName%(%productID%[%IPAddress%])

Explanation

A fan failure was detected.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP address

System action

None

System administrator response

Contact your Fujitsu customer engineer (CE).

swsag4533

The library system error occurred. (FSC=%code%) in %SysName%(%productID%[%IPAddress%])

Explanation

A library failure was detected.

Parameters

%FSC% : Fault symptom code
%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP address

System action

None

System administrator response

Contact your Fujitsu customer engineer (CE).

swsag4534

The front door opened on the library system in %SysName%(%productID%[%IPAddress%])

Explanation

The front door is open.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP address

System action

None

System administrator response

Check the state of the front door.

swsag4535

The library system became offline in %SysName%(%productID%[%IPAddress%])

Explanation

The library is offline.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP address

System action

None

System administrator response

Check the state of the library.

swsag4536

The CIC sensor error occurred in %SysName%(%productID%[%IPAddress%])

Explanation

A CIC sensor failure was detected.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP address

System action

None

System administrator response

Contact your Fujitsu customer engineer (CE).

swsag4537

The CAS unit%value% open error occurred in %SysName%(%productID%[%IPAddress%])

Explanation

An error was detected during open of the cartridge access station.

Parameters

%value% : Message
%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP address

System action

None

System administrator response

Contact your Fujitsu customer engineer (CE).

swsag4538

The adapter%value% Link Down occurred in %SysName%(%productID%[%IPAddress%])

Explanation

The Fibre Channel port link is down.

Parameters

%value% : Unit number
%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP address

System action

None

System administrator response

Check the state of the Fibre Channel port.

swsag4539

The FlashROM error occurred in %SysName%(%productID%[%IPAddress%])

Explanation

An error was detected in the library boot ROM.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP address

System action

None

System administrator response

Contact your Fujitsu customer engineer (CE).

swsag4540

No install adapter card in library system in %SysName%(%productID%[%IPAddress%])

Explanation

A required Fibre Channel port is not mounted.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP address

System action

None

System administrator response

Contact your Fujitsu customer engineer (CE).

swsag4541

Read Data Error in %SystemName%(%ProductID%[%IPAddress%])

Explanation

The drive read error occurred.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP adress

System action

None

System administrator response

Contact the Fujitsu customer engineer (CE) responsible for the device.

swsag4542

Write Data Error in %SystemName%(%ProductID%[%IPAddress%])

Explanation

The drive write error occurred.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP adress

System action

None

System administrator response

Contact the Fujitsu customer engineer (CE) responsible for the device.

swsag4543

Read or Write Data Error in %SystemName%(%ProductID%[%IPAddress%])

Explanation

The read or write data error occurred.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP adress

System action

None

System administrator response

Contact the Fujitsu customer engineer (CE) responsible for the device.

swsag4544

Detected Faulty Media in %SystemName%(%ProductID%[%IPAddress%])

Explanation

Drive media error was detected.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP adress

System action

None

System administrator response

Contact the Fujitsu customer engineer (CE) responsible for the device.

swsag4545

Read Fault in %SystemName%(%ProductID%[%IPAddress%])

Explanation

The tape or drive error occurred.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP adress

System action

None

System administrator response

Contact the Fujitsu customer engineer (CE) responsible for the device.

swsag4546

Write Fault in %SystemName%(%ProductID%[%IPAddress%])

Explanation

The tape or drive error occurred.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP adress

System action

None

System administrator response

Contact the Fujitsu customer engineer (CE) responsible for the device.

swsag4547

Reach end of Media in %SystemName%(%ProductID%[%IPAddress%])

Explanation

Use of media reached the limit.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP adress

System action

None

System administrator response

Please refer to the manual attached to the device.

swsag4548

Not Data Grade Tape in %SystemName%(%ProductID%[%IPAddress%])

Explanation

This tape is not data grade.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP adress

System action

None

System administrator response

Please refer to the manual attached to the device.

swsag4549

Attempted Backup to Write-protected Tape in %SystemName%(%ProductID%[%IPAddress%])

Explanation

Writing was performed to write-protected media.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP adress

System action

None

System administrator response

Please refer to the manual attached to the device.

swsag4550

Tape Drive is in use in %SystemName%(%ProductID%[%IPAddress%])

Explanation

Since a drive is in use, a cartridge cannot be taken out.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP adress

System action

None

System administrator response

Please refer to the manual attached to the device.

swsag4551

Attempted Backup/Restore To Cleaning Tape in %SystemName%(%ProductID%[%IPAddress%])

Explanation

Backup/Restore to cleaning tape was performed.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP adress

System action

None

System administrator response

Please refer to the manual attached to the device.

swsag4552

Unsupported Media in %SystemName%(%ProductID%[%IPAddress%])

Explanation

Unsupported media was inserted.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP adress

System action

None

System administrator response

Please refer to the manual attached to the device.

swsag4553

Detected Snapped Tape in %SystemName%(%ProductID%[%IPAddress%])

Explanation

Snapped tape was detected.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP adress

System action

None

System administrator response

Please refer to the manual attached to the device.

swsag4554

Detected Snapped Tape in %SystemName%(%ProductID%[%IPAddress%])

Explanation

Snapped tape was detected.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP adress

System action

None

System administrator response

Contact the Fujitsu customer engineer (CE) responsible for the device without taking out a tape.

swsag4555

Memory Chip in Cartridge Failure in %SystemName%(%ProductID%[%IPAddress%])

Explanation

Memory tip error in cartridge was detected.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP adress

System action

None

System administrator response

Please refer to the manual attached to the device.

swsag4556

Tape Cartridge was ejected in %SystemName%(%ProductID%[%IPAddress%])

Explanation

The tape cartridge was ejected during read or write processing.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP adress

System action

None

System administrator response

Please refer to the manual attached to the device.

swsag4557

Detected Read-only Media in %SystemName%(%ProductID%[%IPAddress%])

Explanation

Read-only media was detected.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP adress

System action

None

System administrator response

Please refer to the manual attached to the device.

swsag4558

Detected Currupted Directory On Tape in %SystemName%(%ProductID%[%IPAddress%])

Explanation

Currupted directory on tape cartridge was detected.The performance of file reference may fall.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP adress

System action

None

System administrator response

Please refer to the manual attached to the device.

swsag4559

Detected Worn Out Media in %SystemName%(%ProductID%[%IPAddress%])

Explanation

Worn out Media was detected.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP adress

System action

None

System administrator response

Please exchange media.

swsag4560

Tape Device Needs Cleaning in %SystemName%(%ProductID%[%IPAddress%])

Explanation

Tape device needs cleaning.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP adress

System action

None

System administrator response

Please perform cleaning of a tape device.

swsag4561

Drive Needs Routine Cleaning in %SystemName%(%ProductID%[%IPAddress%])

Explanation

Tape device needs routine cleaning.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP adress

System action

None

System administrator response

Please perform cleaning of a tape device.

swsag4562

Detected Worn Out Cleaning Cartridge in %SystemName%(%ProductID%[%IPAddress%])

Explanation

Worn out cleaning cartridge was detected.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP adress

System action

None

System administrator response

Please exchange the cleaning cartridge in a tape drive.

swsag4563

Detected Invalid Cleaning Cartridge in %SystemName%(%ProductID%[%IPAddress%])

Explanation

Invalid cleaning cartridge was detected.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP adress

System action

None

System administrator response

Please exchange for an effective cleaning cartridge.

swsag4564

Request retention in %SystemName%(%ProductID%[%IPAddress%])

Explanation

The request of processing was suspended.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP adress

System action

None

System administrator response

Please refer to the manual attached to the device.

swsag4565

A Redundant Interface Port Failed in %SystemName%(%ProductID%[%IPAddress%])

Explanation

Error occurred in the interface port where it overlaps on a tape drive.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP adress

System action

None

System administrator response

Contact the Fujitsu customer engineer (CE) responsible for the device.

swsag4566

Fan Failed in %SystemName%(%ProductID%[%IPAddress%])

Explanation

Error occurred in the fan on a tape drive.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP adress

System action

None

System administrator response

Contact the Fujitsu customer engineer (CE) responsible for the device.

swsag4567

Power Supply Failed in %SystemName%(%ProductID%[%IPAddress%])

Explanation

Error occurred in the power supply where it overlaps on a tape drive.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP adress

System action

None

System administrator response

Please replace unusual power supply with normal power supply. When it carries out and the state does not change, contact the Fujitsu customer engineer (CE) responsible for the device.

swsag4568

Power Consumption is outside the specified range in %SystemName%(%ProductID%[%IPAddress%])

Explanation

Power consumption of a tape drive is outside the specified range.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP adress

System action

None

System administrator response

Contact the Fujitsu customer engineer (CE) responsible for the device.

swsag4569

Require Preventative Maintenance in %SystemName%(%ProductID%[%IPAddress%])

Explanation

Preventative maintenance of a tape drive is required.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP adress

System action

None

System administrator response

Please perform preventative maintenance of a tape drive.

swsag4570

Drive Hardware Fault in %SystemName%(%ProductID%[%IPAddress%])

Explanation

Drive hardware error occurred.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP adress

System action

None

System administrator response

Please take out a tape from the tape drive and reset the drive. When it carries out and the state does not change, contact the Fujitsu customer engineer (CE) responsible for the device.

swsag4571

Drive Hardware Fault in %SystemName%(%ProductID%[%IPAddress%])

Explanation

Drive hardware error occurred.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP adress

System action

None

System administrator response

Please reboot the tape drive and re-execute. When it carries out and the state does not change, contact the Fujitsu customer engineer (CE) responsible for the device.

swsag4572

Server node Interface Fault in %SystemName%(%ProductID%[%IPAddress%])

Explanation

Error has occurred in the server node interface.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP adress

System action

None

System administrator response

Please re-execute after checking the cable and the connection state of a cable. When it carries out and the state does not change, contact the Fujitsu customer engineer (CE) responsible for the device.

swsag4573

Eject Media Request in %SystemName%(%ProductID%[%IPAddress%])

Explanation

It is the extraction request of media.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP adress

System action

None

System administrator response

Please put in a tape again and re-execute. When it carries out and the state does not change, contact the Fujitsu customer engineer (CE) responsible for the device.

swsag4574

Firmware Download Fault in %SystemName%(%ProductID%[%IPAddress%])

Explanation

Download of a firmware failed.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP adress

System action

None

System administrator response

Please use an effective firmware and re-execute.

swsag4575

Humidity Specification Exceeded in %SystemName%(%ProductID%[%IPAddress%])

Explanation

The state in a tape drive exceeded humidity specification.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP adress

System action

None

System administrator response

Contact the Fujitsu customer engineer (CE) responsible for the device.

swsag4576

Temperature Specification Exceeded in %SystemName%(%ProductID%[%IPAddress%])

Explanation

The state in a tape drive exceeded temperature specification.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP adress

System action

None

System administrator response

Contact the Fujitsu customer engineer (CE) responsible for the device.

swsag4577

Voltage Specification Exceeded in %SystemName%(%ProductID%[%IPAddress%])

Explanation

The voltage to a tape drive is unusual.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP adress

System action

None

System administrator response

Contact the Fujitsu customer engineer (CE) responsible for the device.

swsag4578

Tape Device Predicted to Fail in %SystemName%(%ProductID%[%IPAddress%])

Explanation

The hardware error of a tape drive is predicted.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP adress

System action

None

System administrator response

Contact the Fujitsu customer engineer (CE) responsible for the device.

swsag4579

Drive Hardware Fault in %SystemName%(%ProductID%[%IPAddress%])

Explanation

The hardware error is predicted.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP adress

System action

None

System administrator response

When the diagnostic test was carried out and abnormalities are detected, contact the Fujitsu customer engineer (CE) responsible for the device.

swsag4580

Autoloader Communications Fault in %SystemName%(%ProductID%[%IPAddress%])

Explanation

Communication between AutoLoader and a tape drive has an error.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP adress

System action

None

System administrator response

Please reboot AutoLoader and re-execute. When it carries out and the state does not change, contact the Fujitsu customer engineer (CE) responsible for the device.

swsag4581

Detected Stray Tape In Autoloader in %SystemName%(%ProductID%[%IPAddress%])

Explanation

According to a former hardware error, a tape is in AutoLoader.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP adress

System action

None

System administrator response

Please insert an empty magazine in a drive. Please reboot AutoLoder, when a problem is not solved.When it carries out and the state does not change, contact the Fujitsu customer engineer (CE) responsible for the device.

swsag4582

Autoloader Mechanism Fault in %SystemName%(%ProductID%[%IPAddress%])

Explanation

Abnormalities have occurred in AutoLoader.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP adress

System action

None

System administrator response

Contact the Fujitsu customer engineer (CE) responsible for the device.

swsag4583

Autoloader Door Open in %SystemName%(%ProductID%[%IPAddress%])

Explanation

The door of AutoLoader is open.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP adress

System action

None

System administrator response

Please remove an obstacle from the door of AutoLoader and put in a magazine. Please reboot AutoLoder, when a problem is not solved. When it carries out and the state does not change, contact the Fujitsu customer engineer (CE) responsible for the device.

swsag4584

Autoloader Hardware Fault in %SystemName%(%ProductID%[%IPAddress%])

Explanation

The abnormalities of hardware may have occurred in AutoLoader.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP adress

System action

None

System administrator response

Please reboot AutoLoder. When it carries out and the state does not change, contact the Fujitsu customer engineer (CE) responsible for the device.

swsag4585

Autoloader Cannot Operate Without Magazine in %SystemName%(%ProductID%[%IPAddress%])

Explanation

AutoLoader cannot work without a magazine.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP adress

System action

None

System administrator response

Please insert a magazine in AutoLoader and re-execute.

swsag4586

Autoloader Predicted to Fail in %SystemName%(%ProductID%[%IPAddress%])

Explanation

The abnormalities of the hardware in AutoLoader are predicted.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP adress

System action

None

System administrator response

Contact the Fujitsu customer engineer (CE) responsible for the device.

swsag4590

Media Statistics have been Lost in %SystemName%(%ProductID%[%IPAddress%])

Explanation

Media statistics have been lost.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP adress

System action

None

System administrator response

Contact the Fujitsu customer engineer (CE) responsible for the device.

swsag4591

Tape Directory has been currupted in %SystemName%(%ProductID%[%IPAddress%])

Explanation

The tape directory was destroyed.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP adress

System action

None

System administrator response

Contact the Fujitsu customer engineer (CE) responsible for the device.

swsag4592

Tape just unloaded could not write its system area in %SystemName%(%ProductID%[%IPAddress%])

Explanation

Since the tape is unloaded, it was not able to write to the system area normally.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP adress

System action

None

System administrator response

Please insert a tape and re-execute. When it carries out and the state does not change, contact the Fujitsu customer engineer (CE) responsible for the device.

swsag4593

Could not read System Area in %SystemName%(%ProductID%[%IPAddress%])

Explanation

System Area was not able to be normally read at the time of loading.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP adress

System action

None

System administrator response

Contact the Fujitsu customer engineer (CE) responsible for the device.

swsag4594

Start of Date Not Found in %SystemName%(%ProductID%[%IPAddress%])

Explanation

The start of the date in a tape was not able to be found.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP adress

System action

None

System administrator response

Please use the tape of an effective format and re-execute. When it carries out and the state does not change, contact the Fujitsu customer engineer (CE) responsible for the device.

swsag4596

Drive Communications Fault in %SystemName%(%ProductID%[%IPAddress%])

Explanation

Communication between a library mechanism and a drive is unstable.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP adress

System action

None

System administrator response

Please reboot a library. When it carries out and the state does not change, contact the Fujitsu customer engineer (CE) responsible for the device.

swsag4597

Changer Mechanism Fault in %SystemName%(%ProductID%[%IPAddress%])

Explanation

Abnormalities have occurred to the library mechanism.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP adress

System action

None

System administrator response

Contact the Fujitsu customer engineer (CE) responsible for the device.

swsag4598

Library Hardware Fault in %SystemName%(%ProductID%[%IPAddress%])

Explanation

The abnormalities of the hardware in a library have occurred.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP adress

System action

None

System administrator response

Please reset a library and re-execute. When it carries out and the state does not change, contact the Fujitsu customer engineer (CE) responsible for the device.

swsag4599

Library Hardware Fault in %SystemName%(%ProductID%[%IPAddress%])

Explanation

The abnormalities of the hardware in a library have occurred.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP adress

System action

None

System administrator response

Please reboot a library and re-execute. When it carries out and the state does not change, contact the Fujitsu customer engineer (CE) responsible for the device.

swsag4600

Library Hardware Fault in %SystemName%(%ProductID%[%IPAddress%])

Explanation

The abnormalities of the hardware in a library have occurred.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP adress

System action

None

System administrator response

When the diagnostic test was carried out and abnormalities are detected, contact the Fujitsu customer engineer (CE) responsible for the device.

swsag4601

Library Server node Interface Fault in %SystemName%(%ProductID%[%IPAddress%])

Explanation

Error has occurred in the server node interface.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP adress

System action

None

System administrator response

Please re-execute after checking the cable and the connection state of a cable. When it carries out and the state does not change, contact the Fujitsu customer engineer (CE) responsible for the device.

swsag4602

Library Predicted to Fail in %SystemName%(%ProductID%[%IPAddress%])

Explanation

The abnormalities of the hardware in library are predicted.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP adress

System action

None

System administrator response

Contact the Fujitsu customer engineer (CE) responsible for the device.

swsag4603

Require Preventative Maintenance in %SystemName%(%ProductID%[%IPAddress%])

Explanation

Preventative maintenance of a library is required.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP adress

System action

None

System administrator response

Contact the Fujitsu customer engineer (CE) responsible for the device.

swsag4604

Humidity Specification Exceeded in %SystemName%(%ProductID%[%IPAddress%])

Explanation

The state in a library exceeded humidity specification.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP adress

System action

None

System administrator response

Contact the Fujitsu customer engineer (CE) responsible for the device.

swsag4605

Temperature Specification Exceeded in %SystemName%(%ProductID%[%IPAddress%])

Explanation

The state in a library exceeded temperature specification.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP adress

System action

None

System administrator response

Contact the Fujitsu customer engineer (CE) responsible for the device.

swsag4606

Voltage Specification Exceeded in %SystemName%(%ProductID%[%IPAddress%])

Explanation

The voltage to a library is unusual.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP adress

System action

None

System administrator response

Contact the Fujitsu customer engineer (CE) responsible for the device.

swsag4607

Detected Stray Tape In Drive in %SystemName%(%ProductID%[%IPAddress%])

Explanation

According to a former hardware error, a cartridge is in library.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP adress

System action

None

System administrator response

Please remove a cartridge from a drive.

swsag4608

Picking Cartridge From Slot Fault in %SystemName%(%ProductID%[%IPAddress%])

Explanation

A potential problem is in the drive which emits a cartridge, or in the library mechanism which pick a cartridge from a slot.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP adress

System action

None

System administrator response

Contact the Fujitsu customer engineer (CE) responsible for the device.

swsag4609

Picking Cartridge Into Slot Fault in %SystemName%(%ProductID%[%IPAddress%])

Explanation

A potential problem is in the library mechanism which arranges a cartridge in a slot.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP adress

System action

None

System administrator response

Contact the Fujitsu customer engineer (CE) responsible for the device.

swsag4610

Loading Cartridge Into Drive Fault in %SystemName%(%ProductID%[%IPAddress%])

Explanation

There is the drive which loads a cartridge, or the potential problem about a library mechanism, or the cartridge of non-compatibility.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP adress

System action

None

System administrator response

Contact the Fujitsu customer engineer (CE) responsible for the device.

swsag4611

Library Door Open in %SystemName%(%ProductID%[%IPAddress%])

Explanation

The door of a library is open.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP adress

System action

None

System administrator response

Please remove the obstacle from the door of the library and shut the door of the library. When it carries out and the state does not change, contact the Fujitsu customer engineer (CE) responsible for the device.

swsag4612

Mailslot Fault in %SystemName%(%ProductID%[%IPAddress%])

Explanation

A mechanical problem is in library media reading/writing mailslot.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP adress

System action

None

System administrator response

Contact the Fujitsu customer engineer (CE) responsible for the device.

swsag4613

Library Cannot Operate Without Magazine in %SystemName%(%ProductID%[%IPAddress%])

Explanation

A library cannot work without a magazine.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP adress

System action

None

System administrator response

Please re-execute after inserting a magazine in a library.

swsag4614

Library Security Compromised in %SystemName%(%ProductID%[%IPAddress%])

Explanation

Library security is compromised.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP adress

System action

None

System administrator response

Contact the Fujitsu customer engineer (CE) responsible for the device.

swsag4615

Library Security Mode Changed in %SystemName%(%ProductID%[%IPAddress%])

Explanation

The security mode of a library was changed.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP adress

System action

None

System administrator response

None

swsag4616

Library Manually Turned Offline in %SystemName%(%ProductID%[%IPAddress%])

Explanation

Since the library is manually set as offline, it cannot use.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP adress

System action

None

System administrator response

Please re-execute after starting a library.

swsag4617

Library Drive Turned Offline in %SystemName%(%ProductID%[%IPAddress%])

Explanation

The drive in a library turned offline.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP adress

System action

None

System administrator response

Contact the Fujitsu customer engineer (CE) responsible for the device.

swsag4618

Reading Barcode Labels Fault in %SystemName%(%ProductID%[%IPAddress%])

Explanation

In a library mechanism, there is a potential problem in barcode labels or scanner hardware.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP adress

System action

None

System administrator response

Contact the Fujitsu customer engineer (CE) responsible for the device.

swsag4619

Library Inventory is Inconsistent in %SystemName%(%ProductID%[%IPAddress%])

Explanation

The library detected inconsistency in the catalog.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP adress

System action

None

System administrator response

Please redo a library catalog, in order to correct inconsistency. When it carries out and the state does not change, contact the Fujitsu customer engineer (CE) responsible for the device.

swsag4620

Invalid Library Operation Attempted in %SystemName%(%ProductID%[%IPAddress%])

Explanation

Invalid library operation was carried out.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP adress

System action

None

System administrator response

Please re-execute after checking that library operation is effective. When it carries out and the state does not change, contact the Fujitsu customer engineer (CE) responsible for the device.

swsag4621

Redundant Interface Port Fault in %SystemName%(%ProductID%[%IPAddress%])

Explanation

Error occurred in the interface port where it overlaps on library.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP adress

System action

None

System administrator response

Contact the Fujitsu customer engineer (CE) responsible for the device.

swsag4622

Fan Fault in %SystemName%(%ProductID%[%IPAddress%])

Explanation

Error occurred in the fan on library.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP adress

System action

None

System administrator response

Contact the Fujitsu customer engineer (CE) responsible for the device.

swsag4623

Power Supply Fault in %SystemName%(%ProductID%[%IPAddress%])

Explanation

Error occurred in the power supply where it overlaps on library.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP adress

System action

None

System administrator response

Please replace unusual power supply with a normal thing. When it carries out and the state does not change, contact the Fujitsu customer engineer (CE) responsible for the device.

swsag4624

Power Consumption Warning in %SystemName%(%ProductID%[%IPAddress%])

Explanation

Power consumption of library is outside the specified range.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP adress

System action

None

System administrator response

Contact the Fujitsu customer engineer (CE) responsible for the device.

swsag4625

Robot Hardware Fault in %SystemName%(%ProductID%[%IPAddress%])

Explanation

The abnormalities of the hardware in a robot have occurred.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP adress

System action

None

System administrator response

Contact the Fujitsu customer engineer (CE) responsible for the device.

swsag4626

Robot Hardware Fault in %SystemName%(%ProductID%[%IPAddress%])

Explanation

The abnormalities of the hardware in a robot have occurred.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP adress

System action

None

System administrator response

Contact the Fujitsu customer engineer (CE) responsible for the device.

swsag4627

Barcode Read Error in %SystemName%(%ProductID%[%IPAddress%])

Explanation

Abnormalities have occurred in reading of a barcode.

Parameters

%SystemName% : SysName
%ProductID% : Device name
%IPAddress% : IP adress

System action

None

System administrator response

Contact the Fujitsu customer engineer (CE) responsible for the device.

swsag4641

The PDU%value% error occurred.

Explanation

PDU power supply error was detected.

Parameters

%value% : PDU number

System action

None

System administrator response

Contact your Fujitsu customer engineer (CE).

swsag4642

The PDU%value% power off occurred.

Explanation

PDU power supply interception was detected.

Parameters

%value% : PDU number

System action

None

System administrator response

Contact your Fujitsu customer engineer (CE).

swsag4800

Unit status changed(%status%) in %SysName%(%productID%[%IPAddress%])

Explanation

The status change of the unit was detected.

Parameters

%status% : unit status
%SysName% : SysName
%productID% : Device name
%IPAddress% : IP address

System action

None

System administrator response

When it shows abnormality, contact the Fujitsu customer engineer (CE) responsible for the device.

swsag4803

%EventMessage% in %SysName%(%productID%[%IPAddress%])

Explanation

Event message was detected.

Parameters

%EventMessage% : Message
%SysName% : SysName
%productID% : device name
%IPAddress% : IP address

System action

None

System administrator response

None

swsag4804

Unit Sensor status changed(%status%) in %SysName%(%productID%[%IPAddress%])

Explanation

The status change of the sensor was detected.

Parameters

%status% : Sensor status
%SysName% : SysName
%productID% : Device name
%IPAddress% : IP address

System action

None

System administrator response

When it shows abnormality, contact the Fujitsu customer engineer (CE) responsible for the device.

swsag4805

Unit Port state changed(%state%) in %SysName%(%productID%[%IPAddress%])

Explanation

The status change of the port was detected.

Parameters

%status% : Port status
%SysName% : SysName
%productID% : Device name
%IPAddress% : IP address

System action

None

System administrator response

None

swsag4820

%EventMessage%

Explanation

An event message was detected.

Parameters

%EventMessage% : Message

System action

None

System administrator response

None

swsag4821

%EventMessage% in %SysName%(%productID%[%IPAddress%])

Explanation

A device event defined in the SNMP Trap XML definition file was detected.

Parameters

%EventMessage% : Message defined in the SNMP Trap XML definition file
%SysName% : SysName
%productID% : Device name
%IPAddress% : IP address

System action

None

System administrator response

The response varies depending on the device and event type. For a device for which the XML definition file is provided, check the event type while referring to the following manual:

"Chapter 2 Events in Notifications Sent from Monitored Devices" in the ETERNUS SF Storage Cruiser Event Guide

Depending on the event type, take corrective action such as notifying your Fujitsu customer engineer (CE). For a device for which an original XML definition file was created, perform troubleshooting according to the predetermined maintenance procedure for the device.

swsag4822

%EventMessage% in %SysName%(%productID%[%IPAddress%])

Explanation

The status change of the device was detected.

Parameters

%EventMessage% : Message defined by SNMP Trap XML definition file
%SysName% : SysName
%productID% : Device name
%IPAddress% : IP address

System action

None

System administrator response

When the status indicates Error or Warning, check the device status using the device management software.

When the messages indicated a timeout, check the following:

  • Check the load on the network as this status may occur if the load is high.

  • Check the load of the target server as this status may occur if the load is high.

  • Check the communication modes, if one is set to "Auto Negotiation" and the other is set to "Full (all dual)" this status may occur.

If the problem happens infrequently, collect the data required for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

swsag4900

Setup failed. Reason = Can't setup machine attribute

Explanation

An attempt to add a machine attribute to the node management file failed.

System action

None

System administrator response

Contact your Fujitsu customer engineer (CE).

swsag4901

Setup failed. Reason = Can't setup vendor name

Explanation

An attempt to add a vendor name to the node management file failed.

System action

None

System administrator response

Contact your Fujitsu customer engineer (CE).

swsag4902

Setup failed. Reason = Can't setup registry

Explanation

An attempt to register the node management file in the registry failed.

System action

None

System administrator response

Contact your Fujitsu customer engineer (CE).

swsag4903

Setup failed. Reason = Can't setup MIB information

Explanation

Addition to the MIB management file failed.

System action

None

System administrator response

Contact your Fujitsu customer engineer (CE).

swsag4904

Setup failed. Reason = Can't find file

Explanation

A node icon definition file does not exist.

System action

None

System administrator response

Contact your Fujitsu customer engineer (CE).

swsag4905

Setup failed. Reason = Can't setup event icon

Explanation

Addition of the event type icon file failed.

System action

None

System administrator response

Contact your Fujitsu customer engineer (CE).

swsag4906

Setup failed. Reason = Can't setup event category

Explanation

Addition of event types failed.

System action

None

System administrator response

Contact your Fujitsu customer engineer (CE).

swsag4908

Setup failed. Reason = Systemwalker Centric Manager is not installed

Explanation

Systemwalker Centric Manager has not been installed.

System action

None

System administrator response

Check that Systemwalker Centric Manager has been installed normally and then re-enter the command on the server node on which Systemwalker Centric Manager has been installed.

swsag4909

Setup failed. Reason = Systemwalker Centric Manager is unsupported version

Explanation

The version of Systemwalker Centric Manager is not supported.

System action

None

System administrator response

Check the Systemwalker Centric Manager version, and then re-enter the command on the server node with a supported version.

swsag4910

Server setup completed

Explanation

Server node setup is completed.

System action

None

System administrator response

None

swsag4920

Setup failed. Reason = Can't lock file

Explanation

The file used to add event types could not be locked.

System action

None

System administrator response

Contact your Fujitsu customer engineer (CE).

swsag4921

Setup failed. Reason = Can't read file

Explanation

The file used to add event types could not be read.

System action

None

System administrator response

Contact your Fujitsu customer engineer (CE).

swsag4923

Setup failed. Reason = Can't write file

Explanation

An attempt to write to the file used to add event types failed.

System action

None

System administrator response

Contact your Fujitsu customer engineer (CE).

swsag4924

Setup failed. Reason = Can't unlock file

Explanation

The file used to add event types could not be unlocked.

System action

None

System administrator response

Contact your Fujitsu customer engineer (CE).

swsag4931

Setup failed. Reason = Invalid OS

Explanation

The command was executed on an operating system that is not supported.

System action

None

System administrator response

Re-enter the command in a valid environment.

swsag4932

Setup failed. reason = Can't get current directory

Explanation

The current directory could not be obtained.

System action

None

System administrator response

Contact your Fujitsu customer engineer (CE).

swsag4933

Setup failed. Reason = Can't copy icon file

Explanation

The icon file could not be copied.

System action

None

System administrator response

Contact your Fujitsu customer engineer (CE).

swsag4934

Setup failed. Reason = Systemwalker Centric Manager is not installed

Explanation

Systemwalker Centric Manager has not been installed.

System action

None

System administrator response

Check that Systemwalker Centric Manager has been installed normally and re-enter the command in the client in which Systemwalker Centric Manager has been installed.

swsag4935

Setup failed. reason = Can't open registry file

Explanation

The registry file could not be opened.

System action

None

System administrator response

Contact your Fujitsu customer engineer (CE).

swsag4936

Setup failed. Reason = Can't read registry file

Explanation

Registry key values could not be obtained.

System action

None

System administrator response

Contact your Fujitsu customer engineer (CE).

swsag4937

Setup failed. Reason = Can't open setup file

Explanation

The event type icon definition file could not be opened.

System action

None

System administrator response

Contact your Fujitsu customer engineer (CE).

swsag4938

Setup failed. Reason = Can't write setup file

Explanation

Writing to the event type icon definition file failed.

System action

None

System administrator response

None

swsag4939

Setup failed. Reason = Can't close setup file

Explanation

The event type icon definition file could not be closed.

System action

None

System administrator response

Contact your Fujitsu customer engineer (CE).

swsag4940

Client setup completed.

Explanation

Client setup has been completed.

System action

None

System administrator response

None

swsag4941

Setup failed. Reason = Systemwalker Centric Manager is unsupported version

Explanation

The version of Systemwalker Centric Manager is not supported.

System action

None

System administrator response

Check the Systemwalker Centric Manager version and then re-enter the command on the client with a supported version.

swsag6017

[XXX] device's supportLevel is PARTIAL. Not FULL.

Explanation

XXX device is a Manually Embedded Device.

System action

None

System administrator response

This is not the device that the setting is supported.

swsag6018

[XXX] device has no IP address.

Explanation

XXX device does not have IP address.

System action

None

System administrator response

This is not the device that the setting is supported.

swsag6020

Device does not exists in DB of SANmgr.

Explanation

The specified device does not exist in the database.

System action

None

System administrator response

Ensure the specified device and then re-execute.

swsag6033

Process is skipped.
This device is not set the SNMP Trap transmission place by user operation.

Explanation

The specified device is not the one that the SNMP Trap transmission destination setting is set by user action. Processing to set was skipped.

System action

None

System administrator response

None

swsag6034

Process is skipped.
This device is not support the SNMP Trap transmission function.

Explanation

The specified device does not support the SNMP Trap transmission function.Processing to set was skipped.

System action

None

System administrator response

None

swsag6035

Process is skipped.
This device is a not support device on this function. Please set the SNMP Trap transmission place manually.

Explanation

The specified device supports the SNMP Trap transmission destination, however this software does not support the automatic setting function. Processing to set was skipped. Execute the SNMP Trap transmission destination setting on the device manually.

System action

None

System administrator response

Execute the SNMP Trap transmission destination setting on the device manually.

swsag5000

An authentication error occurred with the entered account information. Please check the user name and password and enter it again.

Explanation

An error was detected during security checking. Check the user name and password in the account information defined in the attestation mechanism management and then re-enter the correct information.If this information is not defined in the attestation mechanism, ask the system administrator.

System action

Interrupts the processing

System administrator response

Check the user name and password that were entered.

Login with administrator authority and then define the account information again.

If the user name and password are correctly input and the account is newly added, the password that was specified at account creation was incorrect. Ask the administrator who created the account to specify again the password according to the procedure for [Password change].

swsag5001

The account information could not be updated. A possible reason for this error is that the account information management file has been corrupted or deleted.

Explanation

Attestation processing for updating the account information failed. A possible reason for this error occurring is that the account information management file has been destroyed.

System action

Interrupts the processing for updating account information

System administrator response

Have your Fujitsu systems engineer (SE) notify the Fujitsu technical department.

swsag5002

An account with this user name has already been registered.

Explanation

The specified account information cannot be registered because it is already registered in the account management.

System action

Interrupts the processing

System administrator response

Use a user name that has not been registered in account information.

swsag5003

The account information required to perform the requested operation cannot be found. Another administrator may have deleted the account.

Explanation

Account information required for executing the specified processing is not found. Another administrator may have deleted the account.

System action

Interrupts the processing

System administrator response

Check that the account required for executing the processing is registered.

swsag5004

There is a problem with the password information for this account. Please check and enter it again.

Explanation

An error was detected in the password information specified for account registration.

System action

Interrupts the processing

System administrator response

Check the password both in the password and password confirmation fields, and then execute registration again.

swsag5005

Nothing was entered in the password and/or password confirmation fields.

Explanation

An attempt was made to register an account without entering the password for registration in the password or password confirmation field.

System action

Interrupts the processing

System administrator response

Register an account by specifying the information required for account registration.

swsag5006

The user name is reserved by the system. Please choose another one.

Explanation

Account information registered in the program cannot be added. (manage/monitor)

System action

Interrupts the processing

System administrator response

Register account information with an account other than "manage" or "monitor".

swsag5007

Some of the required user information was not entered.

Explanation

A user name required for account registration was not specified.

System action

Interrupts the processing

System administrator response

Register an account after specifying the information required for account information registration.

swsag5008

There is a problem with the password information for this account. Please check and enter it again.

Explanation

The information on the current password in the selected account information is incorrect in the procedure of the password change under the account administration.Check the password information and specify it again.

System action

None

System administrator response

Specify the valid password information that is set in the account which executes the password change.

swsag5010

Please check whether the entered administrative server name or port number is wrong.

Explanation

An attempt to set up a network connection to the server that manages attestation management information failed.

System action

Interrupts the processing

System administrator response

Check the specified information on the administrative server.

swsag5011

Or a manager is not found, the case where the administrative server is not started can be considered. Please check whether the wrong administrative server name is entered or the administrative server is started normally.

Explanation

If a connection cannot be set up because the server name entered in the login window does not exist in the network, check whether the specified server name is valid. Alternative, if the administrative server (Manager) is not active, check whether the Manager has been started normally.

System action

Interrupts the processing

System administrator response

Check whether the specified server name is valid. For starting and stopping the administrative server, refer to "12.1.2.2 Starting and stopping the daemons of the administrative server at specific times" in the ETERNUS SF Storage Cruiser User's Guide.

Check whether the Agent is setup valid in case the Agent is installed. Refer to "Chapter 6 Agent installation and setup" in the ETERNUS SF Storage Cruiser Installation Guide.

swsag5012

Access to an account information file went wrong. Please check whether there is any problem in a file.

Explanation

An attempt to access the account management database failed. Check whether the management database can be accessed. Directory under /var/opt/FJSVssmgr

System action

Interrupts the processing

System administrator response

Check whether the directories and files under /var/opt/FJSVssmgr can be accessed. Also check the disk capacity.

swsag5013

%NAME% is not found on the network. Please check that the correct administrative server name was entered.

Explanation

The input administrative server name couldn't find in the network. Please confirm whether input administrative server name is correct. Or, please confirm the thing that the administrative server device starts normally.

Parameters

%NAME% : administrative server name

System action

Interrupts the processing

System administrator response

Please confirm the administrative server device starts normally.

swsag5014

An authentication error occurred with the entered account information. Please check the user name and password and enter it again.

Explanation

The input account isn't registered in the account administrative information. Please confirm the account to the Manager.

System action

Interrupts the processing

System administrator response

Please login in the account of the Manager authority, and confirm account information.

swsag5016

Nothing was entered in the password and/or password confirmation fields.

Explanation

The information that is necessary to change the password has not been specified in the procedure of the password change.

System action

None

System administrator response

Specify the necessary information in The Password Change Input dialog and execute the password change procedure.

swsag5017

No port number was entered for the administrative server.

Explanation

The port number used to connect to the admin server is not specified.

System action

None

System administrator response

Enter the port number used to connect to the admin server.

swsag5101

To be started in Systemwalker Centric Manager failed. Parameters are insufficient or parameters are not correct.

Explanation

The client could not be started in Systemwalker Centric Manager because parameters for the client program are insufficient or parameters are incorrect.

System action

The client start in Systemwalker Centric Manager is stopped.

System administrator response

Refer to "10.2.4.1 Setup from Systemwalker Centric Manager Administrative Client" or "12.4.1 Systemwalker Centric Manager Window Linkage Command (mpaplreg)" in the ETERNUS SF Storage Cruiser User's Guide, and review the setting.