Top
ETERNUS SF Storage Cruiser 14.1 Message Guide

1.1 Messages of ssmgr prefix

ssmgr1000

Unexpected error has occurred.

Explanation

An unexpected exception occurred.

System action

The command terminates abnormally.

System administrator response

This event occurs if "127.0.0.1 localhost" is not defined in the /etc/hosts file of the administrative server. Add the definition and restart the administrative server.

If the above environment setup is normal, collect the data required for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

ssmgr1001

Specified device information isn't registered in the correlation management information.
Please update correlation management information to the newest.

Explanation

The device information displayed in the correlation window is consistent with the information in the correlation database.

Updating the information in the correlation window eliminates any inconsistencies in the information.

System action

The command terminates abnormally.

System administrator response

Perform a "Refresh" for each correlation window.

ssmgr1002

Specified element information doesn't exist in the specification device.
Please update correlation management information to the newest.

Explanation

The device element information displayed in the correlation window is consistent with the information in the correlation database.

Updating the information in the correlation window eliminates any inconsistencies in the information.

System action

The command terminates abnormally.

System administrator response

Perform a "Refresh" for each correlation window.

ssmgr1003

Abnormalities occurred during generation of correlation management information.
Device information has reached the number in which the maximum registration is possible.
Please delete unnecessary equipment information.

Explanation

No more device information can be registered because the maximum amount that can be registered as correlation information has been reached.

Delete any unnecessary device information.

System action

The command terminates abnormally.

System administrator response

Delete any unnecessary device information.

If this does not solve the problem, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu system engineer (SE).

ssmgr1004

Since the specified application element has already existed, it cannot be set as specification server node device.

Explanation

The specified application element cannot be set because it already exists in the specified server node information.

System action

The command terminates abnormally.

System administrator response

Ensure that the specified application element and the server node specification are valid, and then re-execute.

ssmgr1005

The specified application element does not exist in specification server node device.
Please update correlation management information to the newest.

Explanation

The specified application element does not exist in the specified server node information. The relevant element information may have already been deleted.

Update correlation information.

System action

The command terminates abnormally.

System administrator response

Perform a "Refresh" for each correlation window.

ssmgr1006

The element specified at the connection place of an application element does not exist.
Please update correlation management information to the newest.

Explanation

The element specified at the connection destination of the specified application element is not found in the specified server node information.

The relevant element information may have already been deleted. Update the correlation information.

System action

The command terminates abnormally.

System administrator response

Perform a "Refresh" for each correlation window.

ssmgr1007

An element except for the application element was specified.

Explanation

The specified element is not an application element.

System action

The command terminates abnormally.

System administrator response

Specify an application element and then re-execute the processing.

ssmgr1008

Abnormalities occurred during generation of correlation management information. (An unusual occurrence place=%PLACE)

Explanation

An error occurred during the generation of correlation information. The error occurred in %PLACE processing.

Parameters

%PLACE : Name of the processing in which a correlation information generation error occurred

System action

The command terminates abnormally.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

ssmgr1009

Information inconsistency occurred in acquisition of correlation device information.
Abnormalities may have occurred in generation of correlation management information.

Explanation

Although correlation information generation has ended, the correlation information on the specified device contains device information that is not stored in the correlation database.

There is information correlated to a device that terminated abnormally during device information generation.

System action

The command terminates abnormally.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

ssmgr1010

Acquisition of correlation device information went wrong.
The specified device's registration may already be erased from Manager.

Explanation

Configuration information could not be obtained. Check whether the specified device is a device that is subject to this software management. The specified device is probably deregistered from this software.

System action

The command terminates abnormally.

System administrator response

Refresh this software display to check that the specified device information exists.

If this fails to solve the problem, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

ssmgr1011

Fatal mismatching was detected to correlation managed data.
The justification of a correlation management database cannot be secured.

Explanation

Reading or writing of correlation data failed.

Possible causes of this error include a file system problem, the Manager failing to shut down using the appropriate procedure, or old correlation data being read by newer software (i.e., software of a later version).

System action

The command terminates abnormally.

System administrator response

Delete all old correlation data, and then restart the administrative server.

Delete all files in the following directories and their subdirectories:

Platform of Manager

Directory

Windows

$TMP_DIR\Manager\var\opt\FJSVssmgr\current\csdatabase
($TMP_DIR means "Work Directory" specified at the Manager instllation.)

Solaris OS,
Linux

/var/opt/FJSVssmgr/current/csdatabase

If this fails to solve the problem, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

ssmgr1012

Unable to read a file(ID=%ID) from correlation management database.
The contents of the file may be incorrect.

Explanation

Correlation data could not be read successfully.

Possible causes of this error are that the file does not exist, a file system problem, a file error caused by the Manager failing to shut down using the appropriate procedure, or old correlation data being read by newer software (i.e., software of a later version).

Parameters

%ID : ID of the correlation data in which a read error occurred

System action

The command terminates abnormally.

System administrator response

Delete the faulty file, and then restart the administrative server.

Delete all files whose filename is the "%ID".properties type from the following directories and their subdirectories:

Platform of Manager

Directory

Windows

$TMP_DIR\Manager\var\opt\FJSVssmgr\current\csdatabase
($TMP_DIR means "Work Directory" specified at the Manager instllation.)

Solaris OS,
Linux

/var/opt/FJSVssmgr/current/csdatabase

If this fails to solve the problem, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

ssmgr1013

Unable to write the file(ID=%ID) to correlation management database.
Please check write permission of the filesystem or the capacity of the filesystem.

Explanation

Correlation data could not be written successfully.

A possible cause of the error is that the file system is write-protected or the file system is too small.

Parameters

%ID : ID of the correlation data in which a write error occurred

System action

The command terminates abnormally.

System administrator response

Check whether the following file system is write-protected or check the size of the file system.

Platform of Manager

Directory

Windows

$TMP_DIR\Manager\var\opt\FJSVssmgr\current\csdatabase
($TMP_DIR means "Work Directory" specified at the Manager instllation.)

Solaris OS,
Linux

/var/opt/FJSVssmgr/current/csdatabase

If this fails to solve the problem, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

ssmgr1014

Unable to unlink a file(ID=%ID) from correlation management database. Please check write permission of the filesystem.

Explanation

Correlation data could not be deleted successfully.

A possible cause of the error is that the file system is write-protected.

Parameters

%ID : ID of correlation data in which an error occurred

System action

The command terminates abnormally.

System administrator response

Ensure that the following file system is not write-protected.

Platform of Manager

Directory

Windows

$TMP_DIR\Manager\var\opt\FJSVssmgr\current\csdatabase
($TMP_DIR means "Work Directory" specified at the Manager instllation.)

Solaris OS,
Linux

/var/opt/FJSVssmgr/current/csdatabase

If this fails to solve the problem, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

ssmgr1015

Unable to create Directory. Please check write permission of the filesystem.

Explanation

A correlation data storage directory could not be created successfully.

A possible cause of the error is that the file system is write-protected.

System action

The command terminates abnormally.

System administrator response

Ensure that the following file system is not write-protected.

Platform of Manager

Directory

Windows

$TMP_DIR\Manager\var\opt\FJSVssmgr\current\csdatabase
($TMP_DIR means "Work Directory" specified at the Manager instllation.)

Solaris OS,
Linux

/var/opt/FJSVssmgr/current/csdatabase

If this fails to solve the problem, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

ssmgr1016

Registration of an application element went wrong. Abnormalities may have occurred in the device management database.

Explanation

An attempt to register an application element failed.

An error may have occurred in the device management database.

System action

The command terminates abnormally.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

ssmgr1017

Deletion of an application element went wrong. Abnormalities may have occurred in the device management database.

Explanation

An attempt to delete the application element failed.

An error may have occurred in the device management database.

System action

The command terminates abnormally.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

ssmgr1018

The number of parameters is not right.

Explanation

An invalid number of parameters were specified.

System action

The command terminates abnormally.

System administrator response

Check the number of command parameters, and then re-execute.

ssmgr1019

An Internal Program inconsistency was detected. (ErrCode=%ERRCD).

Explanation

A fatal inconsistency was detected in the correlation.

Parameters

%ERRCD : Detail error code

System action

The command terminates abnormally.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

ssmgr1020

The specified application name is already used in the name of another element. Please specify other names.

Explanation

The specified application name cannot be used because it is already used as identifier for another element.

System action

The command terminates abnormally.

System administrator response

Please change the specified application name and register it again.

ssmgr1021

The specified element cannot perform application creation because of a Link piece state. Please update related management information to the newest.

Explanation

The specified element cannot perform application creation because of a Link piece state. Please update related management information to the newest.

If the status doesn't change after updating, the server node cannot recognize the element.

System action

The command terminates abnormally.

System administrator response

Execute "Refresh" in the correlation management window.

If this does not solve the problem, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

ssmgr1022

The specified element cannot add a relation with an application because of a Link piece state. Please update related management information to the newest.

Explanation

The specified element cannot add a relation with an application because of a Link piece state. Please update related management information to the newest.

If the status doesn't change after updating, the server node cannot recognize the element.

System action

The command terminates abnormally.

System administrator response

Execute "Refresh" in the correlation management window.

If this does not solve the problem, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

ssmgr1023

As for the specified element, the correlation with application is already set up. Please update correlation management information to the newest.

Explanation

The specified element has already set up connection with specified application.

Please update correlation management information to the newest and confirm the element has already relation with the application.

System action

The command terminates abnormally.

System administrator response

Execute "Refresh" in the correlation management window.

ssmgr1050

Certification failure.

Explanation

The user is not authorized to perform the operation.

System action

The command terminates abnormally.

System administrator response

Re-execute the processing as a user with the appropriate authority.

ssmgr1051

Certification failure. Please check a user name and a password.

Explanation

User authentication failed.

System action

The command terminates abnormally.

System administrator response

Make sure that the user name and the password are correct, and then re-execute the processing.

ssmgr1052

The specified device management name is already registered. Please specify another name.

Explanation

The specified device management name is already registered.

System action

The command terminates abnormally.

System administrator response

Specify another name. If another name cannot be specified, collect the data required for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

ssmgr1053

The device management name registration to a database went wrong.

Explanation

An attempt to register the device management name with the database failed.

System action

The command terminates abnormally.

System administrator response

Collect the data required for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

ssmgr1054

Although device was detected and the normal end of the device addition was carried out, the device management name registration to a database went wrong.

Explanation

A device was detected, and addition of the device ended normally. However, an attempt to register the device management name with the database failed.

System action

The command terminates abnormally.

System administrator response

Delete the detected device, and re-execute the device detection processing.

If this fails to solve the problem, collect the data required for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

ssmgr1055

Although the normal end of the device addition was carried out, the device management name registration to a database went wrong.

Explanation

Device addition ended normally, but an attempt to register the device management name with the database failed.

System action

The command terminates abnormally.

System administrator response

Delete the added device, and re-execute both the device detection processing and the device addition processing.

If this fails to solve the problem, collect the data required for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

ssmgr1056

Although the normal end of the device creation was carried out, the device management name registration to a database went wrong.

Explanation

Device creation ended normally, but an attempt to register the device management name with the database failed.

System action

The command terminates abnormally.

System administrator response

Delete the created device, and re-execute the device creation processing.

If this fails to solve the problem, collect the data required for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

ssmgr1057

Although the normal end of the device deletion was performed, the device management name deletion from a database went wrong.

Explanation

Device deletion ended normally, but an attempt to delete the device management name from the database failed.

System action

The command terminates abnormally.

System administrator response

Collect the data required for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

ssmgr1060

Unexpected error has occurred.

Explanation

An unexpected exception occurred.

System action

Interrupts the processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

ssmgr1061

There is a mistake in the specified parameter. (code={%INFO})

Explanation

The parameter used in the program is incorrect.

System action

Interrupts the processing.

Parameters

{%INFO} : Detailed information for cause analysis

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

ssmgr1062

Unsupported device is required. (code={%INFO})

Explanation

An operation for a device whose device type, device model, or firmware version is not supported was specified.

System action

Interrupts the processing.

Parameters

{%INFO} : Detailed information for decision analysis

System administrator response

Verify the model type, device name, and firmware version number of the specified device.

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

ssmgr1063

Unable to instantiate the service for the device. (code={%INFO})

Explanation

Initialization of internal information during the operation for the specified device failed.

System action

Interrupts the processing.

Parameters

{%INFO} : Detailed information for cause analysis of the initialization failure

System administrator response

Verify the model type, device name, and firmware version number of the specified device.

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

ssmgr1064

Unable to initialize the service for the device because of illegal access. (code={%INFO})

Explanation

Initialization of internal information during the operation for the specified device failed due to an illegal access.

System action

Interrupts the processing.

Parameters

{%INFO} : Detailed information for cause analysis of the initialization failure

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

ssmgr3000

Unexpected error has occurred.

Explanation

An unexpected exception occurred.

System action

Interrupts the processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

ssmgr3001

Fail connecting to server node

Explanation

An attempt to establish a connection with the server node failed.

System action

Interrupts the processing.

System administrator response

There may be no communication path to the remote server node. Check the network settings.

The Agent may not be active on the remote server node. Check the Agent operating status.

If this fails to solve the problem, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

ssmgr3002

Fail communicating with server node.

Explanation

An error occurred during communication with the server node.

System action

Interrupts the processing.

System administrator response

An error may have occurred on the remote server node network. Check the connection with the server node.

If this fails to solve the problem, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

ssmgr3003

Timeout.

Explanation

A time-out occurred.

System action

Interrupts the processing.

System administrator response

An error may have occurred on the remote server node or network. Check the connection with the server node.

If this fails to solve the problem, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

ssmgr3004

Failed on server node information retrieving.

Explanation

Configuration information could not be obtained.

System action

Interrupts the processing.

System administrator response

An error may have occurred on the network. Check the connection with the server node.

If this fails to solve the problem, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

ssmgr3005

Failed on analyzing structure information.

Explanation

Unexpected data was detected in the configuration information.

The versions of the Agent and Manager are probably different.

System action

Interrupts the processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

ssmgr3006

Fatal error is occurred on analyzing structure information.

Explanation

A fatal error occurred during analysis of configuration information.

System action

Interrupts the processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

ssmgr3007

Failed at Sub Parser loading. %MODULENAME

Explanation

Data that includes information that could not be analyzed by the Manager was obtained.

The versions of the Agent and Manager are probably different.

Parameters

%MODULENAME : Module name

System action

Interrupts the processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

ssmgr3008

Illegal configuration is detected.

Explanation

Invalid value %VALUE was set in setting item %KEY.

Parameters

%KEY : Setting item
%VALUE : Invalid value

System action

Interrupts the processing.

System administrator response

Correct the applicable setting in the setting file.

If this fails to solve the problem, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

ssmgr3009

Server node %HOSTNAME is not found.

Explanation

A server node having name %HOSTNAME could not be found.

Parameters

%HOSTNAME : Server node name

System action

Interrupts the processing.

System administrator response

Server node name resolution failed. Check the DNS settings and so on.

ssmgr3011

New device(s) was/were detected and registered. However, a part of virtual machine was not registered.

Explanation

New devices were detected and registered them. However, any of virtual machines was not registerted.

System action

Terminated normally.

System administrator response

Check if the status of the virtual machine is faulty.

When its status is normal, execute "Register virtual machines". The "Register virtual machine" is to select VM host and to click [File] - [Register] - [Register virtual machines].

If this fails to solve the problem, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

ssmgr3012

New virtual machine was detected and registered.

Explanation

New virtual machine was detected and registered it.

System action

Terminated normally.

System administrator response

None.

ssmgr3013

New virtual machine was detected and registered. However, a part of virtual machine was not registered.

Explanation

New virtual machines were detected and registered them. However, any of virtual machines was not registerted.

System action

Terminated normally.

System administrator response

Check if the status of the virtual machine is faulty.

When its status is normal, execute [Register virtual machines] again.

If this fails to solve the problem, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

ssmgr3014

New virtual machine was not detected.

Explanation

New virtual machine could not be detected.

System action

Terminated normally.

System administrator response

Any of the following may be possible factors.

  • Check whether the monitoring status of VM host is "normal".

    When the monitoring status of VM host is "unmonitored", check if the status of the VM host or network is faulty.
    When the monitoring status of VM host is "invalid Password", the account information that has been set up for the device does not match the account information for the device that is managed by this software. Change the account information managed by this software, and then execute the processing again.
    Change the account information by selecting the target device in the main view of the Resource View, and then selecting [Change account for device management] from the [Device] menu.

  • Check whether the new virtual machine is added.

ssmgr3015

Username or password is incorrect for VM host. VM host: %SYS_NAME:%IP_ADDRESS

Explanation

Failed to login to VM host because username or password is incorrect.

Parameters

%SYS_NAME : Indicates the hostname of VM host that login is rejected
%IP_ADDRESS : Indicates the IP address of VM host that login is rejected

System action

Interrupts the processing.

System administrator response

When this message is displayed by registering VM host, enter the correct username and password and register again.

When this message is displayed for the registered VM host, execute [Device] - [Change account for device management] in the main manu.

ssmgr3016

The VM host is not supported. VM host: %IP_ADDRESS

Explanation

The specified VM host is not supported.

Parameters

%IP_ADDRESS : Indicates the IP address of the specified device

System action

Interrupts the processing.

System administrator response

Only VMware Infrastructure 3 Version 3.5 (or later), VMware vSphere 4 (or later) or VMware ESXi 3.5 (or later) can be registered by using VMware ESX option.

When the used VMware is older than them, install an Agent of this software on host operating system and register the server by using the same method as before.

When the server is registered by using VMware ESX option, the Virtual Center can not be specified. Specify the VM host.

ssmgr3017

Network error occurred in communiation with VM host. VM host: %IP_ADDRESS

Explanation

Failed to communicate with the specified VM host.

Parameters

%IP_ADDRESS : Indicates the IP address of the specified device

System action

Interrupts the processing.

System administrator response

Check the network connection between the Manager and VM host for problems.
Check whether the VM host is running normally.
Check that the specified IP address is an IP address of VM host.

If there are no problem, re-execute the same operation.

If this fails to solve the problem, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

ssmgr3200

Failed to start disks in the RAID group. The specified storage device: {0}

Explanation

It failed to start disks in the RAID group in the specified storage device.

Parameters

{0} : Indicates the IP address of the storage device

System action

Interrupts the processing.

System administrator response

If the IP address of the storage device is an IP address on the Slave CM side, re-register using an IP address on the Master CM side.

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

ssmgr3201

Failed to stop disks in the RAID group. The specified storage device: {0}

Explanation

It failed to stop disks in the RAID group in the specified storage device.

Parameters

{0} : Indicates the IP address of the storage device

System action

Interrupts the processing.

System administrator response

If the IP address of the storage device is an IP address on the Slave CM side, re-register using an IP address on the Master CM side.

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

ssmgr3202

Failed to obtain the disk status of the RAID group. The specified storage device: {0}

Explanation

It failed to obtain the disk status of the RAID group in the specified storage device.

Parameters

{0} : Indicates the IP address of the storage device

System action

Interrupts the processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

ssmgr3203

Failed to start disks in the storage device ({0}) connected with server ({1}).

Explanation

The disk revolution in the storage device connected with the specified server could not be started.

Parameters

{0} : Indicates the IP address of the storage device
{1} : Indicates the IP address of the server

System action

Interrupts the processing.

System administrator response

If the IP address of the storage device is an IP address on the Slave CM side, re-register using an IP address on the Master CM side.

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

ssmgr3204

Failed to stop disks in the storage device ({0}) connected with server ({1}).

Explanation

The disk revolution in the storage device connected with the specified server could not be stopped.

Parameters

{0} : Indicates the IP address of the storage device
{1} : Indicates the IP address of the server

System action

Interrupts the processing.

System administrator response

If the IP address of the storage device is an IP address on the Slave CM side, re-register using an IP address on the Master CM side.

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

ssmgr3205

Failed to obtain the information of the disk used from server ({0}).

Explanation

An error occurred in the information acquistion for the disk that is used from the specified server.

Parameters

{0} : Indicates the IP address of the server

System action

Interrupts the processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

ssmgr3206

Failed to setting for the raidgroup Eco-mode information ({0}).

Explanation

The RAID group Eco-mode setting failed.

Parameters

{0} : Indicates the RAID group number

System action

Interrupts the processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

ssmgr3207

Failed to set or obtain the information for the storage device ({0}).

Explanation

Collection or setting of Eco-mode information for the storage device failed.

Parameters

{0} : Indicates the IP address of the storage device

System action

Interrupts the processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

ssmgr3210

The specified device ({0}) is not a storage device, or is not registered in this software, or does not support the Eco-mode operation.

Explanation

The specified device is not a storage device, or it is not registered as the managed device in this software, or its storage device does not support the Eco-mode operation.

Parameters

{0} : Indicates the specified IP address

System action

Interrupts the processing.

System administrator response

The device of the specified IP address may be not a storage device. Check the device type of the specified IP address. If a device of the specifled IP address is a server node, specify the -server option at the same time.

If the storage device is not registered as the managed device, register it by using this software.

The Eco-mode operation is supported by the following storage devices. Confirm the storage model and firmware version of the specified storage device. The firmware version is older than the following version, apply the firmware that supports the Eco-mode operation, re-execute the operation.

Storage device name

Firmware version

ETERNUS DX60/DX80/DX90

All versions

ETERNUS DX400 series

All versions

ETERNUS DX8000 series

All versions

ETERNUS2000 models 50, 100 and 200

V10L50 or later

ETERNUS4000 models 300 and 500

V11L50 or later

ETERNUS4000 models 400 and 600

All versions

ETERNUS8000 models 700, 900, 1100 and 2100

V11L50 or later

ETERNUS8000 models 800, 1200 and 2200

All versions

If this fails to solve the problem, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

ssmgr3211

The operation cannot be executed, because the fatal inconsistent data was detected in the database of this software.

Explanation

The fatal inconsistent data was detected in the database of this software.

System action

Interrupts the processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

ssmgr3212

Failed to set or obtain the information for the storage device. Error code={0}, detail message={1}

Explanation

An error occurred in the setting for the storage device or the information acquistion for it.

Parameters

{0} : Indicates the error code
{1} : Indicates the detail message

System action

Interrupts the processing.

System administrator response

  • If the IP address of the storage device is an IP address on the Slave CM side, then re-register using an IP address on the Master CM side.

  • When the error code is 40:

    The specified storage device has been locked by another operation. If ETERNUSmgr is open, log out and then re-execute the processing. If the settings for the storage device are in the process of being changed using ETERNUS SF Storage Cruiser (for example, if access paths are being set up, or access paths are being inherited, or the storage device is in the process of being set up using Storage Volume Configuration Navigator), then execute the processing again after the operation has completed.

  • When the error code is 50:

    The target storage device may not support the Eco-mode operation. Check that its storage device is a supported device by referring to "System administrator response" in the ssmgr3210 message.

  • When the error code is 51:

    The firmware of the target storage device may not support the Eco-mode operation. Check that its firmware is a supported firmware by referring to "System administrator response" in the ssmgr3210 message.

  • When the error code is 60 or 70:

    Check the device status and network environment for errors, and then re-execute.

  • When the error code is other:

    Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

ssmgr3213

The disk rotation in the specified RAID group ({0}) cannot be started.

Explanation

The disk rotation of the specified RAID group could not be started. Any of the following may be possible factors.

  • The Eco-mode of the target storage device is set to OFF.

  • The Eco-mode schedule of the target RAID group is not "External".

  • The Eco-mode of the target RAID group is set to OFF.

  • The Eco-mode of the target RAID group is "-" (hyphen).

  • The volumes in the target RAID group are concatenated with other RAID groups by the LUN concatenation function, and the disk control for the related RAID groups cannot be done.

Parameters

{0} : Indicates the RAID group number. (Two or more RAID groups are separated by comma)

System action

Interrupts the processing.

System administrator response

If the IP address of the storage device is an IP address on the Slave CM side, re-register using an IP address on the Master CM side.

Select the device icon of the target storage device in the client window, then display the property window for its storage device and select the "Eco-mode information and set" tab in the displayed property window.

If the current state is one the values below, then change its setting and re-execute. For details, refer to the "ETERNUS SF Storage Cruiser User's Guide", section "Operation" > "Resource View" > "How to control the Eco-mode".

  • When the "Current Eco-mode setting" is OFF:

    Set the Eco-mode of the target storage device to ON.

  • When the "Schedule(No-Name)" of the target RAID group is not "External":

    If you would like to control the Eco-mode schecule by using this software, set the Eco-mode of the target RAID group to ON.
    When the "Eco-mode" is already ON, it has been set by ETERNUSmgr and is not set by this software. If you would like to control the Eco-mode schecule in this software, set the Eco-mode of the target RAID group to ON by using this software.

  • When the "Eco-mode" of the target RAID group is OFF:

    Set the Eco-mode of the target RAID group to ON.

  • When the "Eco-mode" of the target RAID group is "-" (hyphen):

    The Eco-mode setting cannot be done, because the target RAID group fits the following any conditions.

    • The RAID group for which the system disk is included

    • The RAID group for which it is set in the NAS area

    • The RAID group for which the mainframe volumes, MVV volumes or MVV Concatenation volumes are registered

    • The RAID group for which no volumes are registered

  • When the volumes in the target RAID group are concatenated with other RAID groups by the LUN concatenation function:

    Check the followings.

    • When the Eco-mode schedule of the related RAID groups is not "External", the disk rotation cannot be started. Set the Eco-mode schedule of all the related RAID groups to "External".

    • When the Eco-mode of the related RAID groups is set to OFF, the disk rotation cannot be started. Set the Eco-mode of all the related RAID groups to ON.

    • When the Eco-mode of the related RAID groups is "-" (hyphen), the disk rotation cannot be started. When the volumes are concatenated with the RAID group for which the Eco-mode cannot be set, the disk rotation cannot be started.

If this fails to solve the problem, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

ssmgr3214

The disk rotation in the specified RAID group ({0}) cannot be stopped.

Explanation

The disk rotation of the specified RAID group could not be stopped. Any of the following may be possible factors.

  • The Eco-mode of the target storage device is set to OFF.

  • The Eco-mode schedule of the target RAID group is not "External".

  • The Eco-mode of the target RAID group is set to OFF.

  • The Eco-mode of the target RAID group is "-" (hyphen).

  • The volumes in the target RAID group are concatenated with other RAID groups by the LUN concatenation function, and all of the related RAID groups are not specified.

Parameters

{0} : Indicates the RAID group number. (Two or more RAID groups are separated by comma)

System action

Interrupts the processing.

System administrator response

If the IP address of the storage device is an IP address on the Slave CM side, re-register using an IP address on the Master CM side.

Select the device icon of the target storage device in the client window, then display the property window for its storage device and select the "Eco-mode information and set" tab in the displayed property window.

If the current state is one the values below, then change its setting and re-execute. For details, refer to the "ETERNUS SF Storage Cruiser User's Guide", section "Operation" > "Resource View" > "How to control the Eco-mode".

  • When the "Current Eco-mode setting" is OFF:

    Set the Eco-mode of the target storage device to ON.

  • When the "Schedule(No-Name)" of the target RAID group is not "External":

    If you would like to control the Eco-mode schecule by using this software, set the Eco-mode of the target RAID group to ON.
    When the "Eco-mode" is already ON, it has been set by ETERNUSmgr and is not set by this software. If you would like to control the Eco-mode schecule in this software, set the Eco-mode of the target RAID group to ON by using this software.

  • When the "Eco-mode" of the target RAID group is OFF:

    Set the Eco-mode of the target RAID group to ON.

  • When the "Eco-mode" of the target RAID group is "-" (hyphen):

    The Eco-mode setting cannot be done, because the target RAID group fits the following any conditions.

    • The RAID group for which the system disk is included

    • The RAID group for which it is set in the NAS area

    • The RAID group for which the mainframe volumes, MVV volumes or MVV Concatenation volumes are registered

    • The RAID group for which no volumes are registered

  • When the volumes in the target RAID group are concatenated with other RAID groups by the LUN concatenation function, and all of the related RAID groups are not specified:

    Execute the disk rotarion stopping by specifying all of the related RAID groups. However, the disk rotation may be not able to be stopped even if its opearation is executed.
    Check the followings.

    • When the Eco-mode schedule of the related RAID groups is not "External", the disk rotation cannot be stopped. Set the Eco-mode schedule of all the related RAID groups to "External".

    • When the Eco-mode of the related RAID groups is set to OFF, the disk rotation cannot be stopped. Set the Eco-mode of all the related RAID groups to ON.

    • When the Eco-mode of the related RAID groups is "-" (hyphen), the disk rotation cannot be stopped. When the volumes are concatenated with the RAID group for which the Eco-mode cannot be set, the disk rotation cannot be stopped.

If this fails to solve the problem, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

ssmgr3215

Failed to communicate with the storage device.

Explanation

An error occurred during communication with the storage device.

System action

Interrupts the processing.

System administrator response

Any of the following may be possible factors.

  • The target storage device has been locked by another operation. If ETERNUSmgr is open, log out and then re-execute the processing. If the settings for the storage device are in the process of being changed using ETERNUS SF Storage Cruiser (for example, if access paths are being set up, or access paths are being inherited, or the storage device is in the process of being set up using Storage Volume Configuration Navigator), then execute the processing again after the operation has completed.

  • An error may have occurred on the communication destination storage device or network. Check the connection between the server that the Manager is installed and the storage device.

If this fails to solve the problem, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

ssmgr3216

The storage device that supports the Eco-mode operation is not connected with the specified server.

Explanation

The processing was failed. Because the storage device that is connected with the specified server does not exist or does not support the Eco-mode operation.

System action

Interrupts the processing.

System administrator response

Check the connection between the specified server and the storage device, and check that its storage device supports the Eco-mode operation. For the storage devices that support the Eco-mode operation, refer to "System administrator response" in the ssmgr3210 message.

If this fails to solve the problem, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

ssmgr3217

The specified RAID group ({0}) does not exist.

Explanation

The processing was failed, because the specified RAID group in the storage device does not exist.

Parameters

{0} : Indicates the RAID group number

System action

Interrupts the processing.

System administrator response

Specify the correct RAID group number, and then re-execute.

If this fails to solve the problem, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

ssmgr3219

The specified device ({0}) is not a server, or is not registered in this software.

Explanation

The specified device is not a server node, or it is not registered as the managed server node in this software.

Parameters

{0} : Indicates the specified IP address

System action

Interrupts the processing.

System administrator response

Any of the following may be possible factors.

  • The device of the specified IP address may be not the server node. Check the specified IP address.

  • The specifled server may have not been registerd in this software. Check that its device is registered in this software. If not registered, register its device, and then re-execute.

If this fails to solve the problem, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

ssmgr3220

A time-out occurred during the starting disks in the RAID group.

Explanation

The timeout occurred during start the RAID group with syncronous mode.

System action

Interrupts the processing.

System administrator response

Change the timeout value to big by using -time option and then re-execute, if the RAID group status is neither "Active" nor "start request". For details of the -time option, refer to the following section in the ETERNUS SF Storage Cruiser User's Guide.

  • Solaris OS : "12.1.1.7 Disk control command (storageadm spindle)"

  • Linux : "12.2.1.7 Disk control command (storageadm spindle)"

  • Windows : "12.3.1.8 Disk control command (storageadm spindle)"

If this fails to solve the problem, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

ssmgr3221

A time-out occurred during the stopping disks in the RAID group.

Explanation

The timeout occurred during stop the RAID group with syncronous mode.

System action

Interrupts the processing.

System administrator response

Change the timeout value to big by using -time option and then re-execute, if the RAID group status is neither "Idle" nor "stop request". For details of the -time option, refer to the following section in the ETERNUS SF Storage Cruiser User's Guide.

  • Solaris OS : "12.1.1.7 Disk control command (storageadm spindle)"

  • Linux : "12.2.1.7 Disk control command (storageadm spindle)"

  • Windows : "12.3.1.8 Disk control command (storageadm spindle)"

If this fails to solve the problem, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

ssmgr3222

The disks tried to stop might be used from other servers ({0}). Therefore, the stopping process was discontinued.

Explanation

The disks used from the specified server may be used from other servers. Therefore, the stopping process was discontinued.

Parameters

{0} : Indicates the server name or WWPN of HBA

System action

Interrupts the processing.

System administrator response

Check the operating status and the disk using status in the displayed other servers.
When the server has been registered in this software, the name of its server is displayed.
When the server has not been registered in this software, the WWPN value of HBA that is loaded in its server is displayed.

When the stop of disk is possible, e.g. other servers have stopped or the share disk is not used, re-execute the command with -f option.

For detalis of command, refer to "Chapter 12 Command References" in the ETERNUS SF Storage Cruiser User's Guide.

ssmgr3223

The storage device ({0}) is not in the Eco-mode operation.

Explanation

The storage device that is not started the Eco-mode operation is specified.

Parameters

{0} : Indicates the IP address of storage device

System action

Interrupts the processing.

System administrator response

Check that the Eco-mode operation is started in the specified storage device.

If this fails to solve the problem, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

ssmgr3224

The Eco-mode has already started.({0})

Explanation

Eco-mode operation has already been started.

Parameters

{0} : Indicates the IP address of the specified storage device

System action

Interrupts the processing.

System administrator response

Check that the Eco-mode operation is started in the specified storage device. If Eco-mode operation is already started and this message is output, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

ssmgr3225

The Eco-mode has already been suspended.({0})

Explanation

Eco-mode is not operating.

Parameters

{0} : Indicates the IP address of the specified storage device

System action

Interrupts the processing.

System administrator response

Check the Eco-mode operation status in the specified storage device. If Eco-mode operation has not been started and this message is output, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

ssmgr3226

The specified raid group ({0}) is not set the Eco-mode.

Explanation

Eco-mode cannot be set for the RAID group.

Parameters

{0} : Indicates the RAID group number

System action

Interrupts the processing.

System administrator response

The status of the specified RAID group makes it impossible to set Eco-mode. Check the RAID group status, then try again. Alternatively, for details on the RAID groups for which Eco-mode cannot be set, refer to the "ETERNUS SF Storage Cruiser User's Guide", section "Overview" > "Summary of Each Function" > "Energy-saving operation for storage device".

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

ssmgr3227

The specified raid group is not set the Eco-mode.

Explanation

Eco-mode cannot be released for a RAID group for which Eco-mode is not already set.

System action

Interrupts the processing.

System administrator response

Check the Eco-mode status of the specified RAID group, check the RAID group status, then try again. Alternatively, if Eco-mode cannot be released, collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information".

ssmgr3228

The specified raid group number is used in the Thin Provisioning Pool.

Explanation

Processing was interrupted because the specified RAID group is used in a Thin Provisioning Pool.

System action

Interrupts the processing.

System administrator response

Check the RAID group status and specify a RAID group that is not used in a Thin Provisioning Pool.
Check the RAID group and then try again. Alternatively, if Eco-mode cannot be released , then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

ssmgr3301

Failed to obtain the disk information.

Explanation

The disk information could not be obtained.

System action

Interrupts the processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

ssmgr3302

Failed to obtain the raidgroup information.

Explanation

The RAID group informaion could not be obtained.

System action

Interrupts the processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

ssmgr3303

Failed to create the raidgroup.

Explanation

The RAID group cannot be created.

System action

Interrupts the processing.

System administrator response

If the IP address of the storage device is an IP address on the Slave CM side, re-register using an IP address on the Master CM side.

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

ssmgr3304

Failed to delete the raidgroup.

Explanation

The RAID group cannot be deleted.

System action

Interrupts the processing.

System administrator response

If the IP address of the storage device is an IP address on the Slave CM side, re-register using an IP address on the Master CM side.

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

ssmgr3305

Failed to obtain the volume information.

Explanation

The volume information cannot be obtained.

System action

Interrupts the processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

ssmgr3306

Failed to create the volume.

Explanation

The volume cannot be created.

System action

Interrupts the processing.

System administrator response

If the IP address of the storage device is an IP address on the Slave CM side, re-register using an IP address on the Master CM side.

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

ssmgr3307

Failed to delete the volume.

Explanation

The volume cannot be deleted.

System action

Interrupts the processing.

System administrator response

If the IP address of the storage device is an IP address on the Slave CM side, re-register using an IP address on the Master CM side.

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

ssmgr3308

Failed to format the volume.

Explanation

The volume cannot be formatted.

System action

Interrupts the processing.

System administrator response

If the IP address of the storage device is an IP address on the Slave CM side, re-register using an IP address on the Master CM side.

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

ssmgr3309

Failed to obtain the affinitygroup.

Explanation

The affinitygroup information cannot be obtained.

System action

Interrupts the processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

ssmgr3310

Failed to create the affinitygroup.

Explanation

The affinitygroup cannot be created.

System action

Interrupts the processing.

System administrator response

If the IP address of the storage device is an IP address on the Slave CM side, re-register using an IP address on the Master CM side.

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

ssmgr3311

Failed to delete the affinitygroup.

Explanation

The affinitygroup cannot be deleted.

System action

Interrupts the processing.

System administrator response

If the IP address of the storage device is an IP address on the Slave CM side, re-register using an IP address on the Master CM side.

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

ssmgr3312

Failed to modify the affinitygroup.

Explanation

The affinitygroup cannot be modified.

System action

Interrupts the processing.

System administrator response

If the IP address of the storage device is an IP address on the Slave CM side, re-register using an IP address on the Master CM side.

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

ssmgr3351

The specified device ({0}) is not registered in this software.

Explanation

The specified device is not registered as the managed device in this software.

Parameters

{0} : Indicates the specified IP address

System action

Interrupts the processing.

System administrator response

Check that the specified device is registered in this software. If not registered, register its device, and then re-execute.

ssmgr3352

Two or more devices to which specified IP address ({0}) was set were detected.

Explanation

The device could not be identified because more than one device with the specified IP address were detected.

Parameters

{0} : Indicates the specified IP address

System action

Interrupts the processing.

System administrator response

Check whether the same IP address has been set up for more than one device (as a result of configuring devices manually, for example).

To change the IP address of a device that has been configured manually, select the device in the manual configuration window, and then select [Change Device Information] from the [Device] menu.
To change the IP address of a device that has not been configured manually, delete the settings for the device, and then register it again with the new IP address.

Check that the IP address to be specified is unique within this software, and then execute the processing again.

ssmgr3353

The "Monitoring Status" of the specified storage device ({0}) is not "normal".

Explanation

The "Monitoring Status" of the specifed storage device is not "normal".

Parameters

{0} : Indicates the IP address of the storage device

System action

Interrupts the processing.

System administrator response

The "Monitoring Status" in the property for the specified storage device may be any possibility of the following factors.

  • When it is "unmonitored"

    An error may have occurred with the network or with the destination storage device. Check the status of the connection between the storage device and the device where the Manager is installed.

  • When it is "undefined"

    The storage device has been detected by this software, but it has not been registered. Register it as a SAN device, and then execute the processing again.

ssmgr3354

The "Monitoring Status" of the specified switch ({0}) is not "normal".

Explanation

The "Monitoring Status" of the specifed switch device is not "normal".

Parameters

{0} : Indicates the IP address of the switch device

System action

Interrupts the processing.

System administrator response

The "Monitoring Status" in the property for the specified switch device may be any possibility of the following factors.

  • When it is "unmonitored"

    An error may have occurred with the network or with the destination switch. Check if the status of the switch or network is faulty.

  • When it is "undefined"

    The storage device has been detected by this software, but it has not been registered. Register it as a SAN device, and then execute the processing again.

  • When it is "invalid Password"

    The account information that has been set up for the device does not match the account information for the device that is managed by this software. Change the account information managed by this software, and then execute the processing again.
    Change the account information by selecting the target device in the main view of the Resource View, and then selecting [Change account for device management] from the [Device] menu.

ssmgr3355

The specified device ({0}) is not a device to be operated.

Explanation

The specified device cannot be operated.

Parameters

{0} : Indicates the specified IP address of the device

System action

Interrupts the processing.

System administrator response

Check that the device with the specified IP address is either a storage device or a switch.

Execute the processing again after specifying the IP address of either a storage device or a switch (or both).

ssmgr3356

Two or more storage devices were specified.

Explanation

The multiple storage devices were specified, so the processing were failed.

System action

Interrupts the processing.

System administrator response

To specify multiple IP addresses, execute the processing again by specifying the IP address of a storage device for which zones have been set up and the IP address of a switch for which zoning settings have been made.

ssmgr3357

Two or more switches were specified.

Explanation

The multiple switch devices were specified, so the processing were failed.

System action

Interrupts the processing.

System administrator response

To specify multiple IP addresses, execute the processing again by specifying the IP address of a storage device for which zones have been set up and the IP address of a switch for which zoning settings have been made.

ssmgr3358

Specified CA ({0}) is not installed in the specified storage device ({1}).

Explanation

Processing failed because the WWPN for the specified CA has not been stored on the specified storage device.

Parameters

{0} : Indicates the WWPN of the specified CA
{1} : Indicates the IP address of the specified storage device

System action

Interrupts the processing.

System administrator response

Any of the following may be possible factors.

  • Check the WWPN for the specified CA. If the WWPN for the specified CA is incorrect, execute the processing again by specifying a WWPN (for the specified CA) that has been stored on the specified storage device.

  • Check the IP address for the specified storage device. If the IP address for the specified storage device is incorrect, execute the processing again by specifying the IP address for a storage device where the WWPN for the specified CA has been stored.

ssmgr3359

Specified CA ({0}) is not found in this software.

Explanation

Processing failed because either: (1) the storage device (where the WWPN for the specified CA has been stored) has not been registered, or (2) the WWPN for the specified CA is incorrect.

Parameters

{0} : Indicates the WWPN of the specified CA

System action

Interrupts the processing.

System administrator response

Any of the following may be possible factors.

  • Check the specified CA WWPN. If it is wrong, specify the correct CA WWPN and re-execute.

  • Check whether the storage device (where the WWPN for the specified CA has been stored) has been registered with this software. If not, register the storage device, and then execute the processing again.

ssmgr3360

The specified Affinity Group number ({0}) does not in the specified storage device ({1}).

Explanation

The specified affinity group number does not exist in the specified storage device.

Parameters

{0} : Indicates the specified affinity group number (decimal number)
{1} : Indicates the IP address of the specified storage device

System action

Interrupts the processing.

System administrator response

Any of the following may be possible factors.

  • Check that the specified affinity group number exists in the specified storage device. If the specified affinity group number is wrong, specify the existing affinity group number in the specified storage device and re-execute.

  • Check the IP address of the specified storage device. If it is wrong, specify the correct IP address of the storage device and re-execute.

  • In all other cases, create the specified affinity group on the specified storage device and then re-execute.

ssmgr3361

Specified HBA WWPN ({0}) has already been set to the specified Affinity Group number ({1}).

Explanation

The specified HBA WWPN is already set to the specified affinity group number.

Parameters

{0} : Indicates the specified HBA WWPN
{1} : Indicates the specified affinity group number (decimal number)

System action

Interrupts the processing.

System administrator response

Check the specified HBA WWPN.
If the specified HBA WWPN is correct, this indicates that the specified affinity group has already been set up and therefore no need to set it up again.
The specified HBA WWPN is wrong, specify the correct HBA WWPN and re-execute.

ssmgr3362

Specified HBA WWPN ({0}) has already been set to a different Affinity Group number ({1}).

Explanation

The specified HBA WWPN is already set to different affinity group number.

Parameters

{0} : Indicates the specified HBA WWPN
{1} : Indicates the affinity group number (decimal number) that have beed set.

System action

Interrupts the processing.

System administrator response

Any of the following may be possible factors.

  • Check the specified HBA WWPN. If it is wrong, specify the correct HBA WWPN and re-execute.

  • If the affinity group number has been changed, delete the settings for the specified HBA WWPN from the affinity group that has already been set up, and then re-execute.

ssmgr3363

Specified HBA WWPN ({0}) is not set to any Affinity Group of specified CA ({1}).

Explanation

The specified HBA WWPN has not been set up in any of the affinity groups for the CA for the specified storage device.

Parameters

{0} : Indicates the specified HBA WWPN
{1} : Indicates the specified CA WWPN

System action

Interrupts the processing.

System administrator response

Any of the following may be possible factors.

  • Check the specified HBA WWPN. If it is wrong, specify the correct HBA WWPN and re-execute.

  • Check the specified CA WWPN. If it is wrong, specify the correct CA WWPN and re-execute.

ssmgr3364

Specified HBA WWPN ({0}) is not set to Affinity Group Number ({1}) of specified CA ({2}). Specified HBA WWPN ({0}) is set to Affinity Group Number ({3}).

Explanation

The specified HBA WWPN is already set to different affinity group number.

Parameters

{0} : Indicates the specified HBA WWPN
{1} : Indicates the specified affinity group number (decimal number)
{2} : Indicates the specified CA WWPN
{3} : Indicates the set affinity group number (decimal number)

System action

Interrupts the processing.

System administrator response

Any of the following may be possible factors.

  • Check the specified HBA WWPN. If it is wrong, specify the correct HBA WWPN and re-execute.

  • Check the specified CA WWPN. If it is wrong, specify the correct CA WWPN and re-execute.

  • Check the specified affinity group number. If it is wrong, specify the correct affinity group number and re-execute.

ssmgr3365

Specified CA ({0}) is not connected with the specified switch ({1}).

Explanation

The specified CA is not connected with the specified switch device.

Parameters

{0} : Indicates the specified CA WWPN
{1} : Indicates the IP address of the specified switch device

System action

Interrupts the processing.

System administrator response

Any of the following may be possible factors.

  • Check the specified CA WWPN. If it is wrong, specify the correct CA WWPN and re-execute.

  • Check the IP address of the specified switch device. If it is wrong, specify the correct IP address and re-execute.

  • Check the status of the connection between the specified CA and the switches within the fabric that includes the specified switch. If the CA is not connected to any of the switches in the fabric, connect the CA to any of the switches in the fabric, and then re-execute.

ssmgr3366

Specified CA ({0}) is not connected with the switch.

Explanation

The specified CA is not connected with the switch device.

Parameters

{0} : Indicates the specified CA WWPN

System action

Interrupts the processing.

System administrator response

Any of the following may be possible factors.

  • Check the specified CA WWPN. If it is wrong, specify the correct CA WWPN and re-execute.

  • Check the status of the connection between the specified CA and the switches within the fabric that includes the specified switch. If the CA is not connected to any of the switches in the fabric, connect the CA to any of the switches in the fabric, and then re-execute.

ssmgr3367

Because the security of the specified switch ({0}) is not set, the zoning cannot be set.

Explanation

Zoning settings cannot be made because security settings have not been made for the specified switch.

Parameters

{0} : Indicates the IP address of the specified switch device

System action

Interrupts the processing.

System administrator response

Security settings have not been made because zoning settings have not been made for the specified switch. Make temporary zoning settings, and then execute the processing again.

For details on how to set up temporary zoning , refer to the "ETERNUS SF Storage Cruiser User's Guide", section "Environment Configuration" > "Fibre Channel Switch" > "SN200 (Brocade) Fibre Channel Switch".

By specifying the -f option, zones can be forcibly set up even on fibre channel switches where zoning settings have not been made. However, if temporary zones are created, or if zoning settings are made forcibly by specifying the -f option, access from all zones other than the zone specified with the -f option will be blocked. For this reason, do not implement these measures while the target fibre channel switch environment is operating. Implement these measures immediately after the fibre channel switch environment has been installed and before operations have started (or while operations are paused).

ssmgr3368

The specified zoning ({0}) has already been set to the specified switch ({1}).

Explanation

The specified zoning is already set to the specified switch device.

Parameters

{0} : Indicates the zoning between the specified HBA WWPN and the specified CA WWPN
{1} : Indicates the IP address of the specified switch device

System action

Interrupts the processing.

System administrator response

Any of the following may be possible factors.

  • Check the specified CA WWPN. If it is wrong, specify the correct CA WWPN and re-execute.

  • Check the specified HBA WWPN. If it is wrong, specify the correct HBA WWPN and re-execute.

  • Check the IP address of the specified switch device. If it is wrong, specify the correct IP address and re-execute.

  • If the combination of the specified HBA WWPN and CA WWPN is correct and the IP address of the specified switch is also correct, this indicates that the specified zoning has already been set up and therefore no need to set it up again.

ssmgr3369

The specified zoning ({0}) is not exist in the specified switch ({1}).

Explanation

Deletion of the specified zoning has failed because it has not been set up on the specified switch.

Parameters

{0} : Indicates the zoning between the specified HBA WWPN and the specified CA WWPN
{1} : Indicates the IP address of the specified switch device

System action

Interrupts the processing.

System administrator response

Any of the following may be possible factors.

  • Check the specified CA WWPN. If it is wrong, specify the correct CA WWPN and re-execute.

  • Check the specified HBA WWPN. If it is wrong, specify the correct HBA WWPN and re-execute.

  • Check the IP address of the specified switch device. If it is wrong, specify the correct IP address and re-execute.

ssmgr3370

The principal switch in a fabric where the specified switch ({0}) belongs is not registered in this software.

Explanation

The principal switch device in a fabric where the specified switch device belongs is not registered in this software.

Parameters

{0} : Indicates the IP address of the specified switch device

System action

Interrupts the processing.

System administrator response

Check that all swtich devices in a fabric where the specified switch device belong to is registered in this software. If any switch devices are not registered in this software, re-execute operation after registering devices.

ssmgr3371

The "Monitoring Status" of the principal switch in a fabric where the specified switch ({0}) belongs is "undefined".

Explanation

The processing was failed, because the monitoring status of the principal switch device in a fabric where the specified switch device belongs is "undefined".

Parameters

{0} : Indicates the IP address of the specified switch device

System action

Interrupts the processing.

System administrator response

The principal switch device in a fabric where the specified switch device belongs has been detected by this software, but it has not been registered. Register it as a SAN device, and then execute the processing again.

ssmgr3372

The "Monitoring Status" of the principal switch in a fabric where the specified switch ({0}) belongs is "invalid Password".

Explanation

The processing was failed, because the monitoring status of the principal switch device in a fabric where the specified switch device belongs is "invalid Password".

Parameters

{0} : Indicates the IP address of the specified switch device

System action

Interrupts the processing.

System administrator response

Check the account information of the principal switch device in a fabric where the specified switch device belongs.
The account information that has been set up for the device does not match the account information for the device that is managed by this software. Change the account information managed by this software, and then execute the processing again.
Change the account information by selecting the target device in the main view of the Resource View, and then selecting [Change account for device management] from the [Device] menu.

ssmgr3400

The specified device ({0}) is not a storage device in this software.

Explanation

The specified device is not storage device.

Parameters

{0} : Indicates the specified IP address

System action

Interrupts the processing.

System administrator response

The device with the specified IP address might not be a storage device. Check the device type for the specified IP address.

If the device for the specified IP address has not been detected by this software, detect the device and then execute the processing again.

ssmgr3401

The "Monitoring Status" of the specified storage device ({0}) is not "normal".

Explanation

The "Monitoring Status" of the specified storage device is not "normal".

Parameters

{0} : Indicates the IP address of the specified storage device

System action

Interrupts the processing.

System administrator response

The "Monitoring Status" in the property for the specified storage device may possibly be any of the following factors.

  • When it is "unmonitored"

    An error may have occurred with the network or with the destination storage device. Check the status of the connection between the storage device and the device where the Manager is installed.

  • When it is "undefined"

    The storage device has been detected by this software, but it has not been registered. Register it as a SAN device, and then execute the processing again.

ssmgr3402

Failed to set or obtain the information for the storage device. Error code={0}, detail message={1}

Explanation

An error has occurred with either: (1) the settings for the storage device, or (2) the information acquisition processing.

Parameters

{0} : Indicates the error code
{1} : Indicates the detail message

System action

Interrupts the processing.

System administrator response

  • When the error code is 60, 70, or 80

    Check whether there are any errors with either the status of the device or the network environment, and then execute the processing again.

  • When the error code is other number

    Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

ssmgr3403

Specified storage device ({0}) is a device of the uncorrespondence.

Explanation

An error has occurred with either: (1) the settings for the storage device, or (2) the information acquisition processing.

Parameters

{0} : Indicates the IP address of the specified storage device

System action

Interrupts the processing.

System administrator response

Check that the specified storage device is supported. For details of the support device, refer to the following section in the ETERNUS SF Storage Cruiser User's Guide.

  • Solaris OS : "12.1.4 Commands for storage management"

  • Linux : "12.2.4 Commands for storage management"

  • Windows : "12.3.4 Commands for storage management"

If this does not solve the problem, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

ssmgr3404

Specified storage device ({0}) is being locked.

Explanation

The setting of the specified storage device is locked.

Parameters

{0} : Indicates the IP address of the specified storage device

System action

Interrupts the processing.

System administrator response

The specified storage device has been locked by another operation. If ETERNUSmgr is open, log out and then re-execute the processing. If the settings for the storage device are in the process of being changed using ETERNUS SF Storage Cruiser (for example, if access paths are being set up, or access paths are being inherited, or the storage device is in the process of being set up using Storage Volume Configuration Navigator), then execute the processing again after the operation has completed.

If this does not solve the problem, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

ssmgr3405

The operation cannot be executed, because the fatal inconsistent data was detected in the database of this software.

Explanation

The fatal inconsistent data was detected in the database of this software.

System action

Interrupts the processing.

System administrator response

Settings for the storage device have been made, but these settings have not been successfully reflected in the database for this software. Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

ssmgr3410

Specified RAID group ({0}) does not exist.

Explanation

The specified RAID group number does not exist.

Parameters

{0} : Indicates the RAID group number

System action

Interrupts the processing.

System administrator response

Specify the correct RAID group number, and then re-execute.

If this does not solve the problem, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

ssmgr3411

The volume of the unsupport is registered in specified RAID group ({0}).

Explanation

Processing has terminated because there was a volume of a type that could not be deleted when the RAID group was forcibly deleted.

Parameters

{0} : Indicates the RAID group number

System action

Interrupts the processing.

System administrator response

Check volumes that is registered in the RAID group, delete volumes excluding the OLU volumes by using ETERNUSmgr, and then re-execute.

If this does not solve the problem, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

ssmgr3412

Name cannot be specified for specified storage device ({0}).

Explanation

Processing has terminated because an alias was specified for a device for which alias settings cannot be made.

Parameters

{0} : Indicates the IP address of the specified storage device

System action

Interrupts the processing.

System administrator response

Check the storage device model. When the storage device is ETERNUS DX400 series, ETERNUS DX8000 series, ETERNUS4000 or ETERNUS8000, The alias name cannot be set. Re-execute without setting alias name.

If this does not solve the problem, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

ssmgr3413

Because the number of RAID groups reaches the upper bound, it is not possible to make it.

Explanation

The RAID group could not be created because the maximum number of RAID groups for the storage device has been reached.

System action

Interrupts the processing.

System administrator response

Check the number of RAID groups that have been registered with the device. To create a new RAID group, an existing RAID will need to be deleted.

ssmgr3414

The RAID group cannot be made by combining specified disks ({0}).

Explanation

Processing has terminated because the specified combination of disks is incorrect.

Parameters

{0} : Indicates the disk number

System action

Interrupts the processing.

System administrator response

The problem may be due to one of the following. Check the disk and then execute the processing again.

  • An invalid combination of disks may have been specified when the RAID group was created

  • A disk that is already being used by another RAID group may have been specified

  • Disks with different types may have been specified

  • The specified disk may not exist

  • The reason for failure to create the RAID group may be because the status of the specified disk is "error"

If this does not solve the problem, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

ssmgr3415

The value of assign CM({0}) specified when the RAID group is made is wrong.

Explanation

Processing has terminated because the value of the CM (that was assigned when the RAID group was created) was incorrect.

Parameters

{0} : Indicates the assigned CM

System action

Interrupts the processing.

System administrator response

Specify the correct assigned CM number, and then re-execute.

If this does not solve the problem, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

ssmgr3416

Specified volume ({0}) does not exist.

Explanation

Processing has terminated because the specified volume number has not been registered.

Parameters

{0} : Indicates the volume number

System action

Interrupts the processing.

System administrator response

Specify the correct volume number, and then re-execute.

ssmgr3417

The type of specified volume ({0}) is a unsupport.

Explanation

Processing has terminated because the type of volume specified is not supported by the command.
The only types of volumes that the command supports are OLU volumes that are not LUN concatenated.

Parameters

{0} : Indicates the volume number

System action

Interrupts the processing.

System administrator response

Specify the correct volume number, and then re-execute.

If this does not solve the problem, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

ssmgr3418

Because the number of AffinityGroup reaches the upper bound, it is not possible to make it.

Explanation

A new affinity group cannot be created because the maximum number of affinity groups has been reached.

System action

Interrupts the processing.

System administrator response

Check the number of affinity groups that have been registered with the device. To create a new affinity group, an existing affinity group will need to be deleted.

If this does not solve the problem, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

ssmgr3419

The specified alias name has already been registered.

Explanation

Processing has terminated because the specified alias cannot be registered more than once.

System action

Interrupts the processing.

System administrator response

The alias for the affinity group may already exist. Execute the processing again after specifying the correct alias for the affinity group.

If this does not solve the problem, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

ssmgr3420

Specified AffinityGroup({0}) does not exist.

Explanation

The specified affinity group does not exist.

Parameters

{0} : Indicates the affinity group number

System action

Interrupts the processing.

System administrator response

Specify the correct affinity group number, and then re-execute.

ssmgr3421

Connection AffinityGroup({0}) is a unsupport.

Explanation

The connected affinity group is not supported.

Parameters

{0} : Indicates the affinity group number

System action

Interrupts the processing.

System administrator response

Check the correct affinity group number, and then re-execute.

If this does not solve the problem, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

ssmgr3422

As for specified volume ({0}), the LUN mapping is done.

Explanation

LUN mapping for the specified volume number is complete.

Parameters

{0} : Indicates the volume number

System action

Interrupts the processing.

System administrator response

Specify the correct volume number, and then re-execute.

If this does not solve the problem, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

ssmgr3423

AffinityGroup({0}) is registered in the hostAffinity.

Explanation

The specified affinity group has been registered with the host affinity function.

Parameters

{0} : Indicates the affinity group number

System action

Interrupts the processing.

System administrator response

Delete the affinity group from the host affinity, and then re-execute.

If this does not solve the problem, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE) , then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

ssmgr3424

As for volume({1}) of specified AffinityGroup({0}), the mapping is not done.

Explanation

The volume for the specified affinity group has not been mapped.

Parameters

{0} : Indicates the affinity group number
{1} : Indicates the volume number

System action

Interrupts the processing.

System administrator response

Specify the correct volume number of the affinity group, and then re-execute.

If this does not solve the problem, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

ssmgr3425

Specified LUN({0}) is not set to AffinityGroup({1}).

Explanation

The specified LUN is not set to the affinity group.

Parameters

{0} : Indicates the LUN number
{1} : Indicates the affinity group number

System action

Interrupts the processing.

System administrator response

Specify the correct LUN number of the affinity group, and then re-execute.

If this does not solve the problem, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

ssmgr3426

All mappings of specified AffinityGroup({0}) cannot be deleted.

Explanation

The all mappings of the specified affinity group cannot be deleted.

Parameters

{0} : Indicates the affinity group number

System action

Interrupts the processing.

System administrator response

To delete all mappings for the affinity group, delete the affinity group. Otherwise, specify an affinity group so that at least one mapping exists.

ssmgr3427

Because the number of volumes that can be made in RAID group ({0}) exceeds the upper bound, the volume cannot be made.

Explanation

Processing has terminated because the number of volumes exceeds the maximum number of volumes that can be created within a RAID group.

Parameters

{0} : Indicates the RAID group number

System action

Interrupts the processing.

System administrator response

Check the number of volumes in the RAID groups that have been registered with the device. To create a new volume, either specify a different RAID group, or delete an existing volume.

If this does not solve the problem, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

ssmgr3428

The status of specified RAID group ({0}) is abnormal.

Explanation

Processing has terminated because the status of the specified RAID group prevents processing from being performed.

Parameters

{0} : Indicates the RAID group number

System action

Interrupts the processing.

System administrator response

Check the status of the RAID group. Execute the processing again after the status returns to "normal".

If this does not solve the problem, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

ssmgr3429

Because the capacity of specified RAID group ({0}) is insufficient, the volume cannot be made.

Explanation

The volume cannot be created because the RAID group does not have enough capacity.

Parameters

{0} : Indicates the RAID group number

System action

Interrupts the processing.

System administrator response

Check the capacity of the RAID group, specify the correct volume capacity and re-execute.

If this does not solve the problem, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

ssmgr3430

Because the number of volumes that can be made exceeds the upper bound, it is not possible to make it.

Explanation

Processing has terminated because the number of volumes exceeds the maximum number of volumes that can be registered with the device.

System action

Interrupts the processing.

System administrator response

Check the number of volumes that have been registered with the device. To create a new volume, an existing volume will need to be deleted.

If this does not solve the problem, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

ssmgr3431

The volume exists in specified RAID group ({0}).

Explanation

Processing has terminated because an attempt was made to delete the RAID group where the volume is located.

Parameters

{0} : Indicates the RAID group number

System action

Interrupts the processing.

System administrator response

RAID groups that contain volumes cannot be deleted. Use either of the following methods to delete RAID groups:

  • Delete the volumes in the RAID group before deleting the RAID group.

  • If the volume is an open volume that is not LUN concatenated and not mapped, delete the RAID group forcibly by specifying the -f option.

If this does not solve the problem, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

ssmgr3432

The firmware version of ETERNUS does not correspond to RAID6.

Explanation

The firmware version of ETERNUS disk storage system does not support the RAID6.

System action

Interrupts the processing.

System administrator response

Check the firmware version of ETERNUS disk storage system, and then re-execute.

If this does not solve the problem, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

ssmgr3433

Because RAID is migrating, the RAID group where specified volume ({0}) is included cannot operate it.

Explanation

Operations cannot be performed on the volume because the RAID group is being migrated.

Parameters

{0} : Indicates the volume number

System action

Interrupts the processing.

System administrator response

Execute the processing again after the RAID migration finishes.

If this does not solve the problem, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

ssmgr3434

In the status of specified volume ({0}), it is not possible to process it.

Explanation

The specified operation cannot be performed because the status of the volume is "error".

Parameters

{0} : Indicates the volume number

System action

Interrupts the processing.

System administrator response

Check the status of the volume, and execute the processing again after the status returns to "normal".

If this does not solve the problem, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

ssmgr3435

Because specified volume ({0}) is converting the encryption, it is not possible to operate it.

Explanation

Processing has terminated because the encryption for the specified volume is being converted.

Parameters

{0} : Indicates the volume number

System action

Interrupts the processing.

System administrator response

Execute the processing again after the encryption conversion for the volume finishes.

If this does not solve the problem, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

ssmgr3436

The RAID group where specified volume ({0}) is included cannot operate it because of the LDE.

Explanation

Operations cannot be performed on the volume because Logical Device Expansion (LDE) is being performed for the RAID group that includes the specified volume.

Parameters

{0} : Indicates the volume number

System action

Interrupts the processing.

System administrator response

Execute the processing again after the Logical Device Expansion for the RAID group finishes.

If this does not solve the problem, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

ssmgr3437

LUN({1}) of specified AffinityGroup({0}) is used.

Explanation

Processing has terminated because the specified LUN belongs to an affinity group.

Parameters

{0} : Indicates the affinity group number
{1} : Indicates the LUN number

System action

Interrupts the processing.

System administrator response

Specify the correct LUN number, and then re-execute.

If this does not solve the problem, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

ssmgr3438

Specified LUN({0}) is out of range.

Explanation

The value specified for the LUN number is outside the range of values that can be registered for the device.

Parameters

{0} : Indicates the LUN number

System action

Interrupts the processing.

System administrator response

Specify the correct LUN number, and then re-execute.

If this does not solve the problem, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

ssmgr3439

The number of mappings of specified AffinityGroup({0}) exceeds the upper bound.

Explanation

The number of mappings specified exceeds the maximum number of mappings that can be specified.

Parameters

{0} : Indicates the affinity group number

System action

Interrupts the processing.

System administrator response

Specify the correct mapping, and then re-execute.

If this does not solve the problem, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

ssmgr3440

The RAID group to make the specified volume does not exist.

Explanation

There are no RAID groups where a volume can be created.

System action

Interrupts the processing.

System administrator response

Specify the correct RAID group number, and then re-execute.

If this does not solve the problem, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

ssmgr3441

The specified RAID group cannot register the volume.

Explanation

The volume could not be registered in the RAID group.

System action

Interrupts the processing.

System administrator response

Check the RAID group, and then re-execute.

Volumes cannot be specified as open volumes if any volumes other than open volumes, SDV volumes or SDPV volumes have been registered with the RAID group.

If this does not solve the problem, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

ssmgr3442

Specified AffinityGroup({0}) already exists.

Explanation

The specified affinity group cannot be registered because it already exists.

Parameters

{0} : Indicates the affinity group number

System action

Interrupts the processing.

System administrator response

Check the affinity group number, and then re-execute.

If this does not solve the problem, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

ssmgr3443

The value of specified AffinityGroup({0}) is out of range.

Explanation

The number for the specified affinity group is outside the range of values that can be specified for the device.

Parameters

{0} : Indicates the affinity group number

System action

Interrupts the processing.

System administrator response

Check the affinity group number, and then re-execute.

If this does not solve the problem, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

ssmgr3444

The alias name is not specified.

Explanation

The alias name is not specified.

System action

Interrupts the processing.

System administrator response

Check the name that was specified when the affinity group was created, and then execute the processing again.

To create an affinity group for ETERNUS DX60/DX80/DX90 or ETERNUS2000, an alias must be specified. Set up an alias by specifying the -name option.

If this does not solve the problem, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

ssmgr3445

The specification of the alias name is wrong.

Explanation

The wrong alias name was specified.

System action

Interrupts the processing.

System administrator response

Check the names that were specified when the RAID group, volume and affinity group were created, and then execute the processing again. The following table shows the models for which aliases can be specified at creation time.

Storage device

Creating object

Alias name

Omission

ETERNUS DX60/DX80/DX90
ETERNUS2000

RAID group,
Volume

between 1 and 16 characters

possible

Affinity group

between 1 and 8 characters

impossible

ETERNUS4000 models 300 and 500
ETERNUS8000 models 700, 900, 1100 and 2100

RAID group,
Volume

Unable to set

-

Affinity group

between 1 and 8 characters

possible

ETERNUS DX400 series
ETERNUS DX8000 series
ETERNUS4000 models 400 and 600
ETERNUS8000 models 800, 1200 and 2200

RAID group,
Volume

Unable to set

-

Affinity group

between 1 and 16 characters

possible

If this does not solve the problem, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

ssmgr3446

Specified Storage device ({0}) cannot make the RAID group of RAID5+0.

Explanation

The specified storage device cannot make the RAID group of RAID5+0.

Parameters

{0} : Indicates the IP address of the storage device

System action

Interrupts the processing.

System administrator response

Check if the storage device supports the RAID level of RAID5+0. Specify a supported RAID level and then try again.

If this does not solve the problem, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

ssmgr3447

The specified Thin Provisioning Pool ({0}) does not exist.

Explanation

The specified Thin Provisioning Pool number does not exist.

Parameters

{0} : Indicates the Thin Provisioning Pool number

System action

Interrupts the processing.

System administrator response

Specify a valid Thin Provisioning Pool number and then try again.

ssmgr3448

The specified notice value is invalid.

Explanation

The specified notice threshold value is incorrect.

System action

Interrupts the processing.

System administrator response

Specify a valid notice threshold value and then try again.

The following table shows the notice threshold value types and value ranges that can be set.

Type

Value range

Caution

0 or 5 to 80
and
Not larger than the Warning value

Warning

5 to 99
and
Not smaller than the Caution value

ssmgr3449

The specified device or Thin Provisioning Pool information does not exist.

Explanation

The specified device or Thin Provisioning Pool information does not exist.

System action

Interrupts the processing.

System administrator response

Specify a device for which Pool information exists and a Thin Provisioning Pool number, and then try again.

ssmgr3450

The specified device ({0}) is an unsupported Thin Provisioning.

Explanation

The specified device does not support Thin Provisioning.

Parameters

{0} : Indicates the IP address of the storage device

System action

Interrupts the processing.

System administrator response

The storage devices below support Thin Provisioning. Check the model and firmware edition of the specified storage device. If the firmware is an older edition, then apply firmware that supports Thin Provisioning and try again.

Storage device name

Firmware version

ETERNUS DX400 series
ETERNUS DX8000 series

All versions

ETERNUS4000 models 400 and 600
ETERNUS8000 models 800, 1200 and 2200

V20L30 or later

If this does not solve the problem, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", and contact your Fujitsu systems engineer (SE).

ssmgr4501

Failed to starting virtualization function.

Explanation

The virtualization switch function failed to start. The specified device does not have a virtualization switch function.

System action

Interrupts the processing.

System administrator response

Select a switch that has a virtualization switch function, and then execute the processing again.

ssmgr4502

Virtualization Switch function is already stopped.

Explanation

The user attempted to stop the virtualization switch function, but it was already stopped.

System action

Interrupts the processing.

System administrator response

None.

ssmgr4503

Internal Program Error occurred.

Explanation

An internal program conflict has been detected.

System action

Interrupts the processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

ssmgr4504

The Input CA ({0}) was not found.

Explanation

Either a CA that does not exist in the storage device has been specified, or the storage device where the specified CA exists has not been registered.

Parameters

{0} : Indicates the CA WWPN

System action

Interrupts the processing.

System administrator response

Take the following actions, and then execute the processing again.

  • If the input is incorrect:

    Check whether the CA that exists in the storage device has been entered correctly.

  • If the storage device has not been registered:

    Register the storage device where the specified CA exists.

ssmgr4505

The Input HBA ({0}) was not found.

Explanation

Either an HBA that does not exist in a server device has been specified, or the server device where the specified HBA exists has not been registered.

Parameters

{0} : Indicates the HBA WWPN

System action

Interrupts the processing.

System administrator response

Take the following actions, and then execute the processing again.

  • If the input is incorrect:

    Check whether the HBA that exists in the server device has been entered correctly

  • If the server device has not been registered:

    Register the server device where the specified HBA exists.

ssmgr4506

The virtualization switch that relates to input virtual target ({0}) was not found.

Explanation

Either the specified virtual target does not exist, or the virtualization switch related to the specified virtual target has not been registered.

Parameters

{0} : Indicates the virtual target

System action

Interrupts the processing.

System administrator response

Take the following actions, and then execute the processing again.

  • If the input is incorrect:

    Check whether the virtual target has been entered correctly.

  • If the virtualization switch has not been registered with Virtual Storage Conductor:

    Start the virtualization function for the virtualization switch related to the specified virtual target.

    For details, refer to the "ETERNUS SF Storage Cruiser User's Guide", section "Startup and Setting" > "Registering device" > ""Adding a device (changing from the violet icon state to the registered state)".

  • If the virtual target has not been registered with Virtual Storage Conductor:

    Create a virtual target.

    For details, refer to the " ETERNUS SF Storage Cruiser User's Guide for Virtual Storage Conductor ", section "Operations" > "Creating a Virtual Disk" > "Creating a virtual target".

ssmgr4507

The Fibre Channel cable between FCPort ({0}) - Virtualization Switch ({1}) is not physically connected.

Explanation

The fibre channel cable between the virtualization switch and the target FC port (HBA or CA) is broken.

Parameters

{0} : Indicates the WWPN of the FC port (HBA or CA)
{1} : Indicates the IP address of the virtualization switch

System action

Interrupts the processing.

System administrator response

Take the following actions, and then execute the processing again.

  • If there are any switches that have not been registered:

    Register all of the switches in the fabric where the specified virtualization switch is located.

  • If there is no physical connection between the specified FC port and the fabric:

    Check whether there is a problem with the network environment or the status of the devices in the fabric.

ssmgr4508

The switch that can execute the zoning was not found.

Explanation

No switches for which zoning can be implemented were found within the fabric.

System action

Interrupts the processing.

System administrator response

Check whether there is a problem with the network environment or the status of the devices in the fabric, and then execute the processing again.

ssmgr4509

The specified switch ({0}) is NO_SECURITY state. Processing with switch was skipped.

Explanation

Zoning settings could not be made because the status of the specified switch is NO_SECURITY.

Parameters

{0} : Indicates the IP address of the specified switch device

System action

Interrupts the processing.

System administrator response

Set up a temporary zoning. For details, refer to the " ETERNUS SF Storage Cruiser User's Guide", section "Environment Configuration" > "Fibre Channel Switch" > "SN200 (Brocade) Fibre Channel switch" > "Setting".

ssmgr4510

The virtualization switch ({0}) was not found.

Explanation

The virtualization switch for the specified IP address has not been registered.

Parameters

{0} : Indicates the IP address of the virtualization switch

System action

Interrupts the processing.

System administrator response

Take the following actions, and then execute the processing again.

  • If the input is incorrect:

    Check whether the IP address for the virtualization switch has been entered correctly.

  • If the specified virtualization switch has not been registered:

    Register the virtualization switch for the specified IP address.

ssmgr4511

The virtual initiator that relates to input virtualization switch ({0}) was not found.

Explanation

The virtual initiator associated with the specified virtualization switch could not be found.

Parameters

{0} : Indicates the IP address of the virtualization switch

System action

Interrupts the processing.

System administrator response

Take the following actions, and then execute the processing again.

  • If the input is incorrect:

    Check whether the IP address for the virtualization switch has been entered correctly.

  • If the virtualization switch has not been registered with Virtual Storage Conductor:

    Start the virtualization function for the virtualization switch corresponding to the specified IP address.

    For details, refer to the " ETERNUS SF Storage Cruiser User's Guide", section "Startup and Setting" > "Registering device" > "Adding a device (changing from the violet icon state to the registered state)".

  • In all other cases:

    Check whether there is a problem with the virtualization switch status.

    • Check the operating status of the VSC engine

    • Check the network environment

    For details on how to check the operating status of the VSC engine, refer to the "ETERNUS SF Storage Cruiser User's Guide for Virtual Storage Conductor", section "Maintenance" > "Maintenance Menu of Virtual Storage Window".

ssmgr4512

CA has another affinity group for VI of the virtualization switch.

Explanation

The specified CA has other affinity group setting information for VI of the specified virtualization switch. Only one affinity group can be set from one VI.

System action

Interrupts the processing.

System administrator response

Check that the specified virtualization switch, CA, and affinity group are correct.

If those are specified correctly, collect the data required for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

ssmgr4513

Registration of WWPN is full on CA.

Explanation

The WWPN could not be registered because the maximum number of registered WWPNs for host affinity of the specified CA has been reached.

System action

Interrupts the processing.

System administrator response

Delete unnecessary access path for the specified CA, or increase CA.

ssmgr4514

Virtualization Switch function is already started.

Explanation

The user attempted to start the virtualization switch function, but it was already started.

System action

Interrupts the processing.

System administrator response

None.

ssmgr7000

Failed to start the performance monitor. The target device address: %IP_ADDRESS

Explanation

Performance monitoring failed to start at the device indicated at %IP_ADDRESS.

Parameters

%IP_ADDRESS : Indicates the IP address of the device where performance monitoring is started

System action

Interrupts the processing.

System administrator response

Check the device status and that there are no faults in the network environment, then try again.

If this does not solve the problem, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

ssmgr7001

Failed to stop the performance monitor. The target device address: %IP_ADDRESS

Explanation

Performance monitoring failed to stop at the device indicated at %IP_ADDRESS.

Parameters

%IP_ADDRESS : Indicates the IP address of the device where performance monitoring is started

System action

Interrupts the processing.

System administrator response

Check the device status and that there are no faults in the network environment, then try again.

If this does not solve the problem, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

ssmgr7002

Failed to obtain the status of performance monitor. The target device address: %IP_ADDRESS

Explanation

Collection failed for the performance monitoring status at the device indicated at %IP_ADDRESS.

Parameters

%IP_ADDRESS : Indicates the IP address of the device where performance monitoring is started

System action

Interrupts the processing.

System administrator response

Check the device status and that there are no faults in the network environment, then try again.

If this does not solve the problem, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

ssmgr7003

Not supported performance monitoring. The target device address: %IP_ADDRESS

Explanation

The specified device, indicated at %IP_ADDRESS, does not support the performance monitoring function.

Parameters

%IP_ADDRESS : Indicates the IP address of the device where performance monitoring is started

System action

Interrupts the processing.

System administrator response

Devices other than the NR1000F series do not support use of this command to issue performance monitoring start and stop commands.

If this does not solve the problem, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

ssmgr7004

Failed in the processing of the performance monitoring function because two or more devices with specified address existed. The target device address: %IP_ADDRESS

Explanation

Processing by the performance monitoring function failed because two or more devices have the specified IP address, indicated at %IP_ADDRESS,

Parameters

%IP_ADDRESS : Indicates the IP address of the device where performance monitoring is started

System action

Interrupts the processing.

System administrator response

Check if the correct IP address has been set for the device.

If the device was included manually, then remove and re-register it with the correct IP address, and try again.

If this does not solve the problem, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

ssmgr7005

Already been monitoring the performance. The target device address: %IP_ADDRESS

Explanation

Performance monitoring is already in progress at the specified device, indicated at %IP_ADDRESS.

Parameters

%IP_ADDRESS : Indicates the IP address of the device where performance monitoring is started

System action

Interrupts the processing.

System administrator response

Check the device status.

  • If the performance monitoring status at the device is "Monitoring", then performance is already being monitored at the target device.

  • If the performance monitoring status at the device is "Recovering" or "Error", then stop performance monitoring and then start the processing again.

If this does not solve the problem, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

ssmgr7010

The Performance Monitoring is not set. Please confirm the Performance Monitoring setting.

Explanation

The Performance Monitoring is not set.

System action

Interrupts the processing.

System administrator response

Set the Performance Monitoring, and then re-execute.

ssmgr7101

The device {0} is set enable

Explanation

The device has been enabled.

Parameters

{0} : Device name and IP address

System action

The command is completed normally.

System administrator response

None

ssmgr7102

The device {0} is set disable. If disable the information of threshold setting is deleted.

Explanation

The device has been disabled.

Parameters

{0} : Device name and IP address

System action

The command is completed normally.

System administrator response

None

ssmgr7103

The device {0} is under threshold monitoring. Please stop the threshold monitoring first and set threshold monitoring.

Explanation

The device is monitoring threshold values.

Parameters

{0} : Device name and IP address

System action

The command is completed normally.

System administrator response

None

ssmgr7104

Unable to display the Threshold Monitoring Enable/Disable of the device{0}

Explanation

Displaying Threshold Monitoring Enable/Disable of the device failed.

Parameters

{0} : Device name and IP address

System action

Interrupts the processing

System administrator response

If a detail message is displayed, follow the detail message instructions.

If a detail message is not displayed, collect the data required for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

ssmgr7105

Unable to set enable of threshold setting of the device{0}.

Explanation

Device threshold setting could not be enabled.

Parameters

{0} : Device name and IP address

System action

Interrupts the processing

System administrator response

If a detail message is displayed, follow the detail message instructions.

If a detail message is not displayed, collect the data required for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

ssmgr7106

Unable to set disable of threshold setting of the device {0}.

Explanation

Device threshold setting could not be disabled.

Parameters

{0} : Device name and IP address

System action

Interrupts the processing

System administrator response

If a detail message is displayed, follow the detail message instructions.

If a detail message is not displayed, collect the data required for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

ssmgr7110

Unable to display the Threshold Monitoring Time setting of the device {0}.

Explanation

The window for setting the device threshold monitoring time could not be displayed.

Parameters

{0} : Device name and IP address

System action

Interrupts the processing

System administrator response

If a detail message is displayed, follow the detail message instructions.

If a detail message is not displayed, collect the data required for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

ssmgr7111

Unable to set Threshold Monitoring Time/ Alarm Display Time/ Alarm Frequency of the device {0}.

Explanation

The device threshold monitoring time, alarm display time, or alarm display frequency could not be set successfully.

Parameters

{0} : Device name and IP address

System action

Interrupts the processing

System administrator response

If a detail message is displayed, follow the detail message instructions.

If a detail message is not displayed, collect the data required for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

ssmgr7112

Please set the Alarm Display Time within Threshold Monitoring Time.

Explanation

Set the alarm display time within the threshold monitoring period.

System action

Interrupts the processing

System administrator response

None

ssmgr7113

Please input <Start Time> within 00:00 - 23:59.

Explanation

<Start time> Set the start time to between 00:00 and 23:59.

System action

Interrupts the processing

System administrator response

None

ssmgr7114

Please input <Stop Time> within 00:00 - 24:00.

Explanation

<Stop time> Set the stop time to between 00:00 and 24:00.

System action

Interrupts the processing

System administrator response

None

ssmgr7120

Unable to display Threshold Monitoring Time/ Alarm Display Time/ Alarm Frequency of the device {0}.

Explanation

The device threshold setting, monitoring start, or monitoring stop window could not be displayed.

Parameters

{0} : Device name and IP address

System action

Interrupts the processing

System administrator response

If a detail message is displayed, follow the detail message instructions.

If a detail message is not displayed, collect the data required for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

ssmgr7121

The Performance Monitoring of the device {0} is stopped. Please confirm the Performance Monitoring setting.

Explanation

The device performance monitoring setting is stopped. Check the performance monitoring setting.

Parameters

{0} : Device name and IP address

System action

Interrupts the processing

System administrator response

None

ssmgr7122

{0} setting error : select items, or input the value from {1} to {2}.

Explanation

An item selection error or input value error occurred.

Parameters

{0} : Name of setting item
{1} : Lower limit of input range for the setting item
{2} : Upper limit of input range for the setting item

System action

Interrupts the processing

System administrator response

None

ssmgr7123

When Alarm Tolerance is selected to Consecutive Time, the Rearm value become disable.

Explanation

If continuous time is specified for the allowable alarm range, the lower limit is nullified.

System action

The command is completed normally.

System administrator response

None

ssmgr7124

Unable to set Threshold Monitoring.

Explanation

The threshold monitoring target could not be set.

System action

Interrupts the processing

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

ssmgr7125

The Threshold Monitoring of the device {0} is disabled. Please confirm the Threshold Monitoring setting.

Explanation

The device threshold setting is stopped.

If a continuous time is specified for the allowable alarm range, the lower limit is nullified. Check the threshold setting.

Parameters

{0} : Device name and IP address

System action

Interrupts the processing

System administrator response

None

ssmgr7126

There is mistake of threshold setting. Please confirm the threshold setting.

Explanation

The threshold settings contain an error. Check the threshold settings.

System action

Interrupts the processing

System administrator response

None

ssmgr7127

The Threshold Monitoring setting and Threshold Monitoring start of the device {0} is failed.

Explanation

An attempt to set and start device threshold monitoring failed.

Parameters

{0} : Device name and IP address

System action

Interrupts the processing

System administrator response

Check the Client and Manager versions. Also, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

ssmgr7128

The Threshold Monitoring stop of the device {0} is failed.

Explanation

An attempt to stop device threshold monitoring failed.

Parameters

{0} : Device name and IP address

System action

Interrupts the processing

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

ssmgr7130

Unable to display the Alarm Log Delete Setting.

Explanation

The window for setting device alarm log deletion could not be displayed.

Parameters

{0} : Device name and IP address

System action

Interrupts the processing

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

ssmgr7131

Please input days as a value not exceeding 365 days.

Explanation

Input error. Specify the number of days as a value not exceeding 365.

System action

Interrupts the processing

System administrator response

None

ssmgr7132

Unable to set the Alarm Keep Period of the device {0}.

Explanation

An attempt to set the device alarm holding period failed.

Parameters

{0} : Device name and IP address

System action

Interrupts the processing

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

ssmgr7140

Unable to display the Threshold Monitoring Alarm Log.

Explanation

The threshold monitoring alarm log window could not be displayed.

System action

Interrupts the processing

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

ssmgr7141

Unable to display the Report of report ID {0}. It is possible to be removed the report already. Please confirm.

Explanation

Detail information on the report ID could not be displayed.

Parameters

{0} : Report ID

System action

Interrupts the processing

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

ssmgr7142

Unable to remove the report of selected row.

Explanation

An attempt to delete the selected line failed.

System action

Interrupts the processing

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

ssmgr7143

Unable to renew the Alarm Log.

Explanation

An attempt to update the alarm log failed.

System action

Interrupts the processing

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

ssmgr7144

Unable to sort.

Explanation

Sorting failed.

System action

Interrupts the processing

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

ssmgr7145

Unable to find the alarm log data {0}.

Explanation

Applicable alarm log data cannot be found.

Parameters

{0} : Alarm log data

System action

Interrupts the processing

System administrator response

None

ssmgr7146

Fail to search.

Explanation

Search failed.

System action

Interrupts the processing

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

ssmgr7147

Failed to Save File.Please check write permission of the filesystem or the capacity of the filesystem.

Explanation

File saving failed.

System action

Interrupts the processing

System administrator response

Check whether the file system is write-protected or check the size of the file system.

ssmgr7148

Failed to Save File.

Explanation

File saving failed.

System action

Interrupts the processing

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

ssmgr7150

Failed to print.

Explanation

Printing failed because an error was detected in the printer.

System action

Interrupts the processing

System administrator response

None

ssmgr7151

Please choose printing lines.

Explanation

Select the line to be printed.

System action

Interrupts the processing

System administrator response

None

ssmgr7152

Please choose the target lines.

Explanation

If the print line is not selected, the process cannot be executed. Select the print line to be executed.

System action

Interrupts the processing

System administrator response

None

ssmgr7160

The time and date specification is improper. Please set another value.

Explanation

The time specification is invalid. Specify another value.

System action

Interrupts the processing

System administrator response

None

ssmgr7161

Please set the time between {0} and {1}.

Explanation

Specify the time in the range from {0} to {1}.

Parameters

{0} : 2001/08/01 00:00
{1} : The latest future time that can be specified.

System action

Interrupts the processing.

System administrator response

None

ssmgr7162

The device %NAME%(%IP_ADDRESS%) was already deleted by another Management Window.
The device %NAME%(%IP_ADDRESS%) will be deleted on Performance Management Window.

Explanation

Because the device has been deleted in another management window, the device is also deleted in the performance management window.

Parameters

%NAME% : Name of the registered device
%IP_ADDRESS% : IP address of the registered device

System action

When <OK> button is clicked, the device is deleted and is no longer displayed in the performance management window.

System administrator response

None

ssmgr7163

Please choose the performance item which indicates by graph.

Explanation

Choose the performance item to be shown on the graph.

System action

Interrupts the processing.

System administrator response

None

ssmgr7164

It is not possible to display the performance graph. {0}

Explanation

The performance graph cannot be displayed for the reasons shown in the parameters. Select a Logical Volume not applied using the LUN concatenation function and then re-execute.

To check "Logical Volume applied using the LUN concatenation function":

Put the cursor on the LogicalVolume in the device configuration tree in the Performance Management window to display the tool tip. For a Logical Volume applied using the LUN concatenation function, "Concatenation" is displayed.

Parameters

{0} : Reason for the non-display. Either of the following is displayed:

- The LogicalVolume made by LUN Concatenation function has been selected.

- Some selections RAIDGroup have the LogicalVolume made by LUN Concatenation function.

System action

Interrupts the processing.

System administrator response

None

ssmgr7170

The device {0} is not registered as a candidate for management.
Please carry out an device entries.

Explanation

The specified device is not registered as a management target.

Perform the device registration.

System action

Interrupts the processing.

System administrator response

None

ssmgr7180

Unable to access a config XML file {0}.
Please check other programs are using the file.

Explanation

An attempt was made to obtain access authority to the configuration information file of the device whose performance is being monitored, but the attempt failed.

Another program may be using the configuration information file.

Parameters

{0} : Configuration information file name

System action

Interrupts the processing.

System administrator response

Make sure that another program is not using the configuration information file, and select "Create Configuration Information File" in the performance management window.

ssmgr7190

The Performance Monitoring of the device {0} has stopped.
Please confirm the Performance Monitoring setting.

Explanation

Performance monitoring of the target device has been stopped by another user's operation.

Parameters

{0} : Name and IP address of the device

System action

Interrupts the processing.

System administrator response

None

ssmgr7191

The device {0} is under performance monitoring.
Please confirm the Performance Monitoring setting.

Explanation

Performance monitoring of the target device has been started by another user's operation.

Parameters

{0} : Name and IP address of the device

System action

Interrupts the processing.

System administrator response

None

ssmgr7192

The Threshold Monitoring of the device {0} is {1}.
Please confirm the Threshold Monitoring setting.

Explanation

Performance monitoring of the target device has been started by another user's operation.

Parameters

{0} : Name and IP address of the device
{1} : "Enabled" or "Disabled"

System action

Interrupts the processing.

System administrator response

None

ssmgr7193

The Threshold Monitoring of the device {0} has stopped.
Please confirm the Threshold Monitoring setting.

Explanation

Threshold monitoring of the target device has been stopped by another user's operation.

Parameters

{0} : Name and IP address of the device

System action

Interrupts the processing.

System administrator response

None

ssmgr7194

The device {0} is under threshold monitoring.
Please confirm the Threshold Monitoring setting.

Explanation

Threshold monitoring of the target device has been started by another user's operation.

Parameters

{0} : Name and IP address of the device

System action

Interrupts the processing.

System administrator response

None

ssmgr7195

The Threshold Monitoring Time Setting of device {0} is reset.
Please confirm the Threshold Monitoring Time setting.

Explanation

The time setting of threshold monitoring of the target device has been changed by another user's operation.

Parameters

{0} : Name and IP address of the device

System action

Interrupts the processing.

System administrator response

None

ssmgr8001

CIMOM Engine error occurred on the manager.

Explanation

An error occurred in the CIMOM engine of the Manager.

System action

Interrupts the processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

ssmgr8002

Multiple errors occurred on the manager.

Explanation

Two or more errors occurred in the Manager.

System action

Interrupts the processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

ssmgr8003

Unable to read the manager configuration file '%FILENAME'. The file does not exists or the contents of the file are incorrect.

Explanation

The Manager configuration file could not be read. The configuration file does not exist or contains an error.

Parameters

%FILENAME : Name of Manager configuration file

System action

Interrupts the processing.

System administrator response

Check that the Manager configuration file exists and if it does, whether it contains an error.

If this fails to solve the problem, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

ssmgr8010

Unable to start remote services. The registry server for remote services may not be started on the port %PORT, or the port may already be used by another program.

Explanation

The remote service used by the Manager to provide clients with certain functions could not be started. The registry server is not active for the port number used to provide the functions, or another program is using the same port number.

Parameters

%PORT : Number of the port used by the Manager to provide the client with certain functions

System action

Interrupts the processing.

System administrator response

Check the system environment for problems, such as the operating conditions of other applications.

If this fails to solve the problem, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

ssmgr8011

Unable to start the registry server of port %PORT. The port may already be used by another program.

Explanation

The registry server used by the Manager to provide the client with certain functions could not be started. Another program may be using the port used to provide the functions.

Parameters

%PORT : Number of the port used by the Manager to provide the client with certain functions

System action

Interrupts the processing.

System administrator response

Check the system environment for problems, such as the operating conditions of other applications.

If this fails to solve the problem, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

ssmgr8012

Unable to start the remote service '%NAME'.

Explanation

The remote service used by the Manager to provide the client with certain functions could not be started.

Parameters

%NAME : Name of the remote service that the Manager provides to the client

System action

Interrupts the processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

ssmgr8013

Unable to connect to the manager. Please check whether the manager is operating correctly. The manager address is %ADDRESS.

Explanation

The client failed to set up a connection for communication with the Manager.

Parameters

%ADDRESS : Address used by the client to communicate with the Manager

System action

Interrupts the processing.

System administrator response

  • If an error occurred in the network environment

    Check the network connection between the Client and Manager for problems.
    Check whether the LAN cable is disconnected or whether the LAN cable or network devices are faulty.

  • If the Manager is stopped

    Execute the following command to check whether the Manager is active.

    # /bin/ps -ef | grep /opt/FJSVssmgr/jre/bin/java | grep cruiser=daemon | grep -v grep

    If no process information is output, the Manager is not active. Check the following log on the administrative server:

    /var/opt/FJSVrcxmr/log/systemrm/rcxmr.log

    If the above log ends with the following keyword, JavaVM of the Manager probably terminated abnormally.
    [XXXX.XX.XX XX:XX:XX] is date/time.

    [XXXX.XX.XX XX:XX:XX] Exit : code=255

    The Manager is stopped. Start the Manager.
    In a cluster environment, start the cluster application of the Manager.
    In a non-cluster environment, start the Manager by executing the following command:

    # /opt/FJSVrcxmr/sbin/managerctl start
  • If invalid data was entered

    Check whether the Manager IP address or port number specified to log in to the Manager from the Client is valid.

  • If communication with the Manager fails temporarily

    If this message appears in a dialog box in the GUI client window while the operator does nothing, click <OK> button to close the dialog box and continue operation.
    If the message appears during operation by the operator, perform the same operation again.

If this fails to solve the problem, collect the data required for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

ssmgr8014

Unable to access to the manager. Please check whether the manager is operating correctly. The manager address is %ADDRESS.

Explanation

The client failed to communicate with the Manager.

Parameters

%ADDRESS : Address used by the client to communicate with the Manager

System action

Interrupts the processing.

System administrator response

  • If an error occurred in the network environment

    Check the network connection between the client and Manager for problems.
    Check whether the LAN cable is disconnected or whether the LAN cable or network devices are faulty.

  • If the Manager is stopped

    Execute the following command to check whether the Manager is active.

    # /bin/ps -ef | grep /opt/FJSVssmgr/jre/bin/java | grep cruiser=daemon | grep -v grep

    If no process information is output, the Manager is not active. Check the following log on the Manager:

    /var/opt/FJSVrcxmr/log/systemrm/rcxmr.log

    If the above log ends with the following keyword, JavaVM of the Manager probably terminated abnormally.
    [XXXX.XX.XX XX:XX:XX] is date/time.

    [XXXX.XX.XX XX:XX:XX] Exit : code=255

    The Manager is stopped. Start the Manager.
    In a cluster environment, start the cluster application of the Manager.
    In a non-cluster environment, start the Manager by executing the following command:

    # /opt/FJSVrcxmr/sbin/managerctl start
  • If invalid data was entered

    Check whether the Manager IP address or port number specified to log in to the Manager from the Client is valid.

  • If communication with the Manager fails temporarily

    If this message appears in a dialog box in the GUI client window while the operator does nothing, click <OK> button to close the dialog box and continue operation.
    If the message appears during operation by the operator, perform the same operation again.

If this fails to solve the problem, collect the data required for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

ssmgr8015

Unexpected error occurred on the manager. The manager address is %ADDRESS.

Explanation

An unexpected error, such as a program internal processing error, occurred in the Manager.

Parameters

%ADDRESS : Address used by the client to communicate with the Manager

System action

Interrupts the processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

ssmgr8016

Unrecovered error has been detected in communication between client and manager. The manager may have been exited unusually, or version of client and manager may not be in agreement. The manager address is %ADDRESS.

Explanation

An unrecoverable error was detected during communication between the Client and Manager. The Manager may have terminated abnormally during communication. Alternatively, the Client and Manager versions may be inconsistent.

Parameters

%ADDRESS : Address used by the client to communicate with the Manager

System action

Interrupts the processing.

System administrator response

Check whether the Manager is operating normally. Also, check the Client and Manager versions.

If this fails to solve the problem, then collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information" and contact your Fujitsu systems engineer (SE).

ssmgr8017

Illegal internal processing has been detected. Unable to use the service `%NAME' from any remote clients.

Explanation

An attempt was made to start a service that the client is not permitted to use, as a remote service. This is an invalid internal processing within the program.

Parameters

%NAME : Service name

System action

Interrupts the processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

ssmgr8018

Unable to use the remote service '%NAME' on the manager. The manager address is %ADDRESS.

Explanation

The client requested a service that was not supported by the Manager. The Manager may not have this function.

Parameters

%NAME : Name of the service requested by the client
%ADDRESS : Address used by the client to communicate with the Manager

System action

Interrupts the processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

ssmgr8019

Illegal internal processing has been detected on the manager. Unable to use the service '%NAME'.

Explanation

An unavailable service was requested in the Manager. The Manager is not equipped with the service or the Manager program contains invalid internal processing.

Parameters

%NAME : Name of the requested service

System action

Interrupts the processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

ssmgr8020

Unable to use the function '%FUNCTION' of the service '%NAME'.

Explanation

The client requested a service that is not supported by the Manager. The Manager may not have the function.

Parameters

%NAME : Service name
%FUNCTION : Name of service function

System action

Interrupts the processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

ssmgr8021

Illegal internal processing has been detected. Unknown remote object '%NAME' has been detected in communication between client and manager. The manager address is %ADDRESS.

Explanation

An unrecoverable error was detected during communication between the Client and Manager. The Client and Manager versions are inconsistent, or the client program attempts invalid internal processing.

Parameters

%NAME : Name of invalid remote object
%ADDRESS : Address used by the client to communicate with the Manager

System action

Interrupts the processing.

System administrator response

Check the Client and Manager versions. collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

ssmgr8022

Illegal internal processing has been detected on the manager. Unable to create the service '%NAME'.

Explanation

Invalid internal processing was detected in the Manager. An invalid method was used to initiate the service.

Parameters

%NAME : Name of the service to be instantiated

System action

Interrupts the processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

ssmgr8023

Illegal internal processing has been detected: %DETAIL

Explanation

Invalid internal processing was detected.

Parameters

%DETAIL : Detected error

System action

Interrupts the processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

ssmgr8024

Unrecovered error has been detected: %DATAIL

Explanation

An unrecoverable error was detected.

Parameters

%DETAIL : Detected error

System action

Interrupts the processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

ssmgr8025

Unexpected error has been detected: %DATAIL

Explanation

An unexpected error was detected.

Parameters

%DETAIL : Detected error

System action

Interrupts the processing.

System administrator response

Collect the data needed for troubleshooting as explained in the "ETERNUS SF Storage Cruiser User's Guide", section "D.1 Troubleshooting information", then contact your Fujitsu systems engineer (SE).

ssmgr8030

The manager is under initialization. Please wait for a while. The manager address is %ADDRESS.

Explanation

The Manager is being initialized. Operation by the client is not possible.

Parameters

%ADDRESS : Address used by the client to communicate with the Manager

System action

Interrupts the processing.

System administrator response

The client cannot operate the Manager until initialization of the Manager is completed. Wait a few moments, and retry the operation.