PRIMECLUSTER Wizard for Oracle Configuration and Administration Guide 4.2 - Linux for Itanium -
|
Contents

|
B.1.1 Respectively
This section explains how to create an Oracle resource newly and register it to an existing userApplication that includes an Oracle resource already.

To create a Listener "LISTENER_2" newly and register it to an existing userApplication including an Oracle instance resource and a Listener resource "LISTENER" already.
- Stop RMS on all nodes.
- Start up RMS Wizard by executing "hvw -n <Configuration Name>" command on any node.
- Select Application-Edit in the "Main configuration menu" screen.
- Select userApplication name where resources are registered in the "Application selection menu" screen.
- Select Oracle(Ora_xxx) in the "Settings of turnkey wizard "WIZSTANDBY"" screen.
- Select Additionalxxx in the "Oracle (Ora_xxx:consistent)" screen.
- - In the Standby Operation
If you create and register an Oracle instance resource or an ASM instance resource, select AdditionalInstance here, and edit advanced settings of the resource according to the step "5" of "2.2.9".
If you create and register a Listener resource, select AdditionalListener here, and edit advanced settings of the resource according to the step "6" of "2.2.9".
- - In the Oracle RAC Scalable Operation
If you create and register an Oracle Clusterware resource, select AdditionalOracleClusterware here, and edit advanced settings of the resource according to the step "3" - "5" of "2.3.4".
If you create and register an Oracle RAC instance resource or a Listener resource, select AdditionalRACInstance/Listener here, and edit advanced settings of the resource according to the step "8" - "12" of "2.3.5".
- Repeat the step "6" if need to create and register resources else.
- Select SAVE+EXIT in the "Oracle (Ora_xxx:consistent)" screen after completed.
- Select SAVE+EXIT in the "Settings of turnkey wizard "WIZSTANDBY"" screen.
- Select RETURN in the "Application selection menu" screen.
- Execute Configuration-Generate and Configuration-Activate in the "Main configuration menu" screen.
- Select QUIT in the "Main configuration menu" screen and terminate RMS Wizard.
All Rights Reserved, Copyright(C) FUJITSU LIMITED 2009