Follow the procedure given below to change the IP address of the administrative server.
Change the system IP address on the administrative server.
Reboot the administrative server.
Start the ESC Client, connect to the new IP address of the administrative server. When it connected to the administrative server successfully, delete the old IP address of administrative server when start the ESC client next time by click <delete> button in the login dialog.
Point
If the administrative server is cluster environment, it is necessary to reconstruct the cluster.
Please refer to "Appendix A High-availability admin servers" in ETERNUS SF Storage Cruiser Installation Guide for detail information.
For the device which is under fault management automatically by SNMP trap, it is necessary to change the SNMP Trap transmission place IP address setting. To change SNMP trap transmission setting, refer to "SNMP Trap transmission place IP address change command" in "Chapter 12 Command References", and execute the command.
Follow the procedure given below to change the IP address of a server node.
On the GUI screen, delete the device icon of the server node (without changing the access path).
Change the system IP address on the server node.
Stop the server node Agent on the server node.
Execute the agent information change command on the server node to change the start IP of server node Agent.
For the command that change to Agent start IP, refer to "Agent information change command" in "Chapter 12 Command References" for the detail information.
Restart the server node Agent on the server node.
On the GUI screen, perform "Server registration" with the new IP address.
No special work is required.
To change the name of a server node, use "Delete" (without changing the access path) to delete the device icon registered with the old name. Next, change the name of the server node, and then use "Register server" to register the server node with the new name.
For ESC Agent and SSC Agent, follow the procedure given below to change a server node name.
On the GUI screen, delete the device icon of the server node (without changing the access path). On the GUI screen, delete (no access path change) a device icon of the server node that changes the IP address.
Change the system IP address on the server node.
Stop the server node Agent on the server node.
Execute the agent information change command on the server node to change the start IP of server node Agent.
For the command that change to Agent start IP, refer to "Agent information change command" in "Chapter 12 Command References" for the detail information.
Restart the server node Agent on the server node.
On the GUI screen, perform "Server registration" on the server node.
Note
Information of an associated application element created in the Correlation window is not inherited when the server node name is changed. Register the application element again.
To change the IP address of a device with support level A or B registered with this software or to change the SNMP community name, follow the procedure below:
When the IP address of a device with support level A or B registered with this software is changed, this software can automatically change the IP address part in the properties of the same device.
To change the IP address
Referring "Detecting a device by specifying IP address" in "5.2.1 Device search" to perform device detection by specifying an IP address. Based on this operation, this software detects that the IP address of a registered device has been renewed and automatically changes the IP address information of the target device on this software.
For a device with support level A or B, excluding the server node, IP address information for multiple devices in the subnet can be automatically changed by performing "Detecting for devices in the same subnet as the administrative server automatically" in "5.2.1 Device search".
Management Software call information is not changed automatically. From "Properties" of each device icon, rewrite information manually.
Point
When the SNMP community name of the device has been changed to something other than "public" and its IP address is changed, set a new IP address for the SNMP community name before detecting any device using a new IP address. For the setting, see SNMP_COMMUNITY_NAME_FOR_IP and SNMP_COMMUNITY_NAME_FOR_AUTODISCOVER in "C.2 sanma.conf Parameter", and reflect the contents of the setting file on this software.
To change the SNMP community name
Set the community name of each target device.
For information on the community name of each target device, see "Chapter 4 Environment Configuration".
Set up the admin server.
Set the SNMP_COMMUNITY_NAME_FOR_IP to the setting file by referring to "C.2 sanma.conf Parameter", and reflect the contents of the setting file on this software.
In the environment of a Cluster System Operation, Node name inheritance may be used for Inherit network setting. Node name takeover affects the Name of a Server node.
In changing the Name of a Server node by setting Node name inheritance, refer to "9.1.2.4 Changing the name of a server node (host)".
ESC uses the following four ports.
Port | Description |
---|---|
nfport 23456/tcp | Used for communication between administrative server and client |
sscruisera 4917/tcp | Used for communication between administrative server and managed server node |
ssvscme 7420/tcp ssvscme 7420/udp | Used for communication between the administrative server and virtual switches when using Virtual Storage Conductor |
These port numbers are managed as internal information by the site domain server, domain admin servers, managed server node files (*1), and admin clients. When not setting the port numbers in the files (*1), the numbers above will be used by default.
*1: The files for managed server nodes are as follows:
Type | File name (full path) |
---|---|
Windows | %SystemRoot%¥system32¥drivers¥etc¥services |
Solaris OS | /etc/inet/services |
Linux, | /etc/services |
If you change the port number, set the same number for the other server nodes in ESC that used the previous number.
Example
When nfport of the administrative server is set as 23456:
Set 23456 for nfport of the client.
See
For further details about the ports, refer to "3.1.1 Network requirements".
Change the port number as follows.
How to change the port number of the administrative server and managed server nodes
You can change the port numbers by editing each file as follows:
Platform | Method of editing |
---|---|
Windows | Edit %SystemRoot%¥system32¥drivers¥etc¥services file using an editor application. |
Solaris OS | Edit the /etc/inet/services file using the vi(1) command. |
Linux, | Edit the /etc/services file using the vi(1) command. |
Change the file
Administrative server (Solaris OS, Linux)
Change the lines under /etc/inet/services.
# service names port nos. /protocol names nfport 23456/tcp sscruisera 4917/tcp ssvscme 7420/tcp ssvscme 7420/udp
Administrative server (Windows)
Change the lines under %SystemRoot%¥system32¥drivers¥etc¥services.
# service names port nos. /protocol names nfport 23456/tcp sscruisera 4917/tcp ssvscme 7420/tcp ssvscme 7420/udp
Managed server nodes (Solaris OS)
Change the lines under /etc/inet/services.
# service names port nos. /protocol names sscruisera 4917/tcp
Managed server nodes (Windows)
Change the lines under %SystemRoot%¥system32¥drivers¥etc¥services.
# Service names port nos. /Protocol names sscruisera 4917/tcp
Managed server nodes (Linux)
Change the lines under /etc/services.
# service names port nos. /protocol names sscruisera 4917/tcp
Managed server nodes (HP-UX)
Change the lines under /etc/services.
# service names port nos. /protocol names sscruisera 4917/tcp
Restart all the server nodes where the port numbers have been changed.
See
For changing the port numbers used by Virtual Storage Conductor, refer to "Chapter 3 Building an Environment" in the "ETERNUS SF Storage Cruiser User's Guide for Virtual Storage Conductor".
Change the port number of the admin client
Change the port number with which the admin client is connected to the site admin server.
Start ESC by selecting [start] - [All Programs] - [ETERNUS SF Storage Cruiser] of the admin client or double-clicking the icon on the desktop.
The login window will appear.
Click <Port> button.
The "Port number" window will appear.
Set the port number to be changed, and click <OK> button.
You are returned to the login window.
Click <Login> button on the login window, then connect to the admin server.
The port number becomes enabled as setting information of the site admin server when the network connection to the administrative server succeeds.
After hardware product is added to or removed from the supported devices or after information is added to or deleted from the configuration settings (for a disk array unit, change in a RAID Group, Logical Volume, etc.) for the supported devices or such information is modified, the information of the target device must manually be updated in the following windows:
Main view
Execute [View] - [Refresh] to read the latest conditions of SAN from all the devices. The target device information is updated and displayed.
Relationship management window
When the Relationship management window is being displayed, execute [View] - [Refresh] to read the latest condition of the target device. The target device information is updated and displayed. To display the Relationship management window, see "6.2.1 Correlation window".
Performance management window
Select the target device in the tree of the Performance management window, and then select [Device] - [Create Device Configuration File] from the menu to read the latest condition of the target device. The target device information is updated and displayed. For details, see "7.2.11 Updating configuration information".
Follow the procedure given below to change the password of a device which is been registed to this software.
Objected Device | Conduction |
---|---|
ETERNUS SN200 series (Brocade) Fiber Channel switch | Refer to "User name and password for Fibre Channel switch control" in "4.2.1.1 Setting" to change the registered information. |
Except for the devices described above, there is no necessary to do any deal with this software when change the device's password.