Chapter 3 Model Family-Specific Information | > 3.1 PRIMEPOWER1/200/400/600,GP7000F model200/200R/400/400R/400A/600/600R | > 3.1.6 Hardware Monitoring Information |
The monitoring function automatically operates for all connected devices. For this reason, an application or driver error to the effect that the device is indicated as busy may occur if a device-open operation from another application conflicts with this function.
If this happens, execute the following command to exclude the error-causing device from monitoring.
# /usr/sbin/FJSVmadm/nocheckdev add device_pathname
If this command is executed, the relevant device is not monitored.
See Section 4.12, "nocheckdev (1M)."
The Tape Unit Monitoring menu opens.
Menu items to be displayed depend on the main unit model.
Moreover, there are cases where displayed menu items may not be available for use.
See Section 3.1.2, "Main Unit Models and Available Menus."
The following describes how to operate the Displaying Tape Unit Monitoring Information function:
The tape unit monitoring information appears.
This information includes:
The instance name of the tape unit
The tape unit status
Normal: Normal status
Error: An error was detected. The part needs to be replaced immediately.
Cleaning Required: The part needs to be cleaned.
Specify whether a notification is to be issued to prompt for immediate replacement of the tape unit if a hardware error was detected.
Valid: Notification.
Invalid: No notification.
Specify whether a notification is to be issued to prompt for cleaning when the part needs to be cleaned.
Valid: Notification.
Invalid: No notification.
The following describes how to perform the Setting Tape Unit Monitoring Information operation:
The tape unit monitoring information list appears.
Specify whether a notification is to be issued, for each device. The default is "Valid."
Valid: Notification.
Invalid: No notification.
The above setting can be made for the following types of notifications:
Immediate Replacement Notification Destination: Used to prompt for the immediate replacement of the tape unit if a hardware error was detected.
Cleaning Request Notification Destination: Used to prompt for cleaning if the part needs to be cleaned.
The main units of PRIMEPOWER800/1000/2000 and GP7000F model 1000/2000 do not support this function.
Reset the monitoring information when the tape unit was replaced.
The following explains how to perform the Setting Tape Unit Monitoring Notification operation:
The Setting Tape Unit Monitoring Notification menu opens.
If immediate replacement notification is required, specify the destination to which that notification is automatically sent.
Specify the notification destination from the following:
If cleaning notification is required, specify the destination to which that notification is automatically sent.
Specify the notification destination from the following:
Specify the mail address from the Setting Monitoring Notification Information menu of the Hardware Monitoring Information menu.