The Disk Monitoring function automatically monitors all connected devices.
For this reason, an application or driver error may occur if an operational conflict with other applications occurs or the disk array device is used.
If this happens, execute the following command to exclude the error-causing device from monitoring.
# /usr/sbin/FJSVmadm/nocheckdev add device_pathname
If this command is executed, the relevant device is not monitored.
See Section 4.12, "nocheckdev (1M)."
The Disk Monitoring menu opens.
The menu items to be displayed depend on the main unit model. Moreover, there are cases where displayed menu items may not be available for use.
See Section 3.1.2, "Main Unit Models and Available Menus."
The following describes how to operate the Displaying Disk Monitoring Information function:
The disk monitoring information appears.
This information includes:
The instance name of the disk device
The disk status
Normal: Normal status
Error: A disk error was detected. The part needs to be replaced immediately.
Replace: A disk error was detected. Preventive replacement of the part is required.
Indicates whether a notification is to be issued to prompt for immediate replacement when an error was detected.
Valid: Notification
Invalid: No notification
Indicates whether a notification is to be issued to prompt for preventive replacement when replacement is required.
Valid: Notification
Invalid: No notification
The following describes how to perform the Setting Disk Monitoring Information operation.
The main units of PRIMEPOWER800/1000/2000 and GP7000F model 1000/2000 do not support the setting of [Setting Valid/Invalid Notification].
The disk monitoring information list appears.
Specify whether a notification to be is issued, for each device. The default is "Valid."
Valid: Notification
Invalid: No notification
The above setting can be made for the following types of notifications:
Used to prompt for the immediate replacement of a disk when a hardware error was detected.
Used to monitor the threshold managed by the SMART function and to prompt for preventive replacement of a disk before a hardware error is detected.
Reset the monitoring information when a disk was replaced.
The following describes how to perform the Setting Disk Monitoring Notification operation:
The Setting Disk Monitoring Notification menu opens.
If immediate replacement notification is required, specify the destination to which that notification is automatically sent.
Specify the notification destination from the following:
If preventive replacement notification is required, specify the destination to which that notification is automatically sent.
Specify the notification destination from the following:
Specify the mail address from the Setting Monitoring Notification Information menu of the Hardware Monitoring Information menu.