Chapter 3 Model Family-Specific Information> 3.1 PRIMEPOWER1/200/400/600,GP7000F model200/200R/400/400R/400A/600/600R> 3.1.6 Hardware Monitoring Information

3.1.6.3 Disk Monitoring

The Disk Monitoring function automatically monitors all connected devices.

For this reason, an application or driver error may occur if an operational conflict with other applications occurs or the disk array device is used.

If this happens, execute the following command to exclude the error-causing device from monitoring.

# /usr/sbin/FJSVmadm/nocheckdev add device_pathname

If this command is executed, the relevant device is not monitored.

See Section 4.12, "nocheckdev (1M)."

Displaying the Disk Monitoring menu

Operation

  1. From the Hardware Monitoring Information menu, select [Disk Monitoring].

    The Disk Monitoring menu opens.

    The menu items to be displayed depend on the main unit model. Moreover, there are cases where displayed menu items may not be available for use.

    See Section 3.1.2, "Main Unit Models and Available Menus."

Displaying Disk Monitoring Information

The following describes how to operate the Displaying Disk Monitoring Information function:

Operation

  1. From the Disk Monitoring menu, select [Displaying and Setting Disk Monitoring Information].

    The disk monitoring information appears.

    This information includes:

Setting Disk Monitoring Information

The following describes how to perform the Setting Disk Monitoring Information operation.

The main units of PRIMEPOWER800/1000/2000 and GP7000F model 1000/2000 do not support the setting of [Setting Valid/Invalid Notification].

Operation

  1. From the Disk Monitoring menu, select [Displaying and Setting Disk Monitoring Information].

    The disk monitoring information list appears.

  2. Select the disk to be set.
  3. Enter the following information in the menu:

Setting Disk Monitoring Notification

The following describes how to perform the Setting Disk Monitoring Notification operation:

Operation

  1. From the Disk Monitoring menu, select [Setting Disk Monitoring Notification].

    The Setting Disk Monitoring Notification menu opens.

  2. Enter the following information in the menu:

    Specify the mail address from the Setting Monitoring Notification Information menu of the Hardware Monitoring Information menu.