Machine Administration Guide 2.6 |
Contents
Index
![]() ![]() |
Chapter 3 Model Family-Specific Information | > 3.1 PRIMEPOWER1/200/400/600,GP7000F model200/200R/400/400R/400A/600/600R | > 3.1.6 Hardware Monitoring Information |
The following describes how to operate the Fan Monitoring function:
The Fan Monitoring menu opens.
The following describes how to operate the Displaying Fan Monitoring Information function:
The fan monitoring information appears.
This information includes:
The identifier of the fan
The fan name is displayed in the following formats:
Fan Unit of Main Cabinet |
: |
FAN#n (n is the fan identification number.) |
FEP Fan Unit of Main Cabinet |
: |
FEPFAN#n (n is the fan identification number.) |
Fan Unit of Expansion Cabinet |
: |
rci-address-FAN#n (n is the fan identification number.) |
cabinet-name#m-FAN#n (m is the cabinet identification number and n is the fan identification number.) |
||
FEP Fan Unit of Expansion Cabinet |
: |
rci-address-FEPFAN#n (n is the fan identification number.) |
The status of the fan
Normal: Normal status
Error : A fan error was detected. The part needs to be replaced.
Prepare: The expiration date of the service life for the fan is approaching. A new part for replacement needs to be prepared.
Replace: The expiration date of the service life for the fan is approaching. The part needs to be replaced.
Expire: The fan life has expired. The part needs to be replaced immediately.
None: Not mounted.
Time during which the power to the fan is on
Indicates whether an error is to be reported if it is detected.
Valid: Notification.
Invalid: No notification.
Indicates whether a notification is to be issued by Life Monitoring to prompt for the preparation of a new part for replacement if the expiration date of the service life of the fan is approaching.
Valid: Notification.
Invalid: No notification.
Indicates whether a notification is to be issued from Life Monitoring to prompt for part replacement if the expiration date of the fan life is approaching.
Valid: Notification.
Invalid: No notification.
Indicates whether a notification is to be issued by Life Monitoring to prompt for part replacement if the month and year of the fan life is approaching.
Valid: Notification. (Every day)
Invalid: No notification.
The following describes how to perform the Setting Fan Monitoring Information operation:
The fan monitoring information list appears.
If the fan was replaced, change the fan's power-on time.
The default is "0."
If the main unit was installed again, the power-on time of all fans in the main unit is "0." The setting value of the fan power-on time can be retained by saving the hardware monitoring information before reinstalling the main unit and by restoring the monitoring information after reinstalling the main unit.
See Section 3.1.6.11, "Saving/Restoring Hardware Monitoring Information."
Specify whether a notification is to be issued, for each notification.
The default is "Valid." The default for the expire notification is "Invalid."
Valid: Notification
Invalid: No notification
The following notifications can be specified:
Error Notification: Used to prompt for device replacement if an error is detected.
Prepare Notification: Used to prompt for the preparation of a new device for replacement if the fan unit power-on time has reached 90% of the lifetime.
Replace Notification: Used to prompt for device replacement if the fan unit power-on time has reached 100% of the lifetime.
Expire Notification: Used to prompt for device replacement if the fan unit power-on time has exceeded the lifetime. (Every day)
Reset monitoring information if the fan unit has been replaced.
The following describes how to perform the Setting Fan Monitoring Notification operation:
The Setting Fan Monitoring Notification menu opens.
Depending on whether an error notification is required, select whether the notification is to be issued, for each notification destination.
Specify whether the notification is to be issued as follows:
Valid: Notification
Invalid: No notification
Depending on whether a life notification is required, select whether the notification is to be issued, for each notification destination.
Specify whether a notification is to be issued as follows:
Valid: Notification
Invalid: No notification
Specify the mail address in the Setting Monitoring Notification Information menu of the Hardware Monitoring Information menu.