PRIMECLUSTER Global Link Services Configuration and Administration Guide: Redundant Line Control Function 4.1 (for Solaris(TM) Operating System)
Contents Index PreviousNext

Chapter 3 Environment configuration> 3.3 Additional system setup

3.3.4 NIC switching mode

The procedure to add the configuration information using NIC unused in the other virtual interfaces is as follows:

  1. Set up a virtual interface using the "hanetconfig create" command. For information, see Section "7.1 hanetconfig Command".
  2. Set up the standby patrol function using the "hanetconfig create" command (only if the standby patrol function is used). For information, see Section "7.1 hanetconfig Command".
  3. Set up the router/HUB monitoring function using the "hanetpoll create" command. For information, see Section "7.7 hanetpoll Command".

The procedure to share NIC used in a virtual interface of the already defined NIC switching mode and to add the configuration information is as follows (when using an NIC sharing function):

  1. Set a virtual interface with "hanetconfig copy" command. See "7.1 hanetconfig Command" for the detail.
  2. Set standby patrol with "hanetconfig create" command. (Only when using a standby patrol function.) It is not necessary to set if a standby patrol function is already set in a virtual interface that already shares NIC. See "7.1 hanetconfig Command" for the detail.
  3. Set a router/HUB monitoring function with "hanetpoll copy" command. See "7.7 hanetpoll Command" for the detail.

When the Solaris zone is used

If you want to use a redundant physical interface of NIC switching in the Solaris zone, it is necessary to add the configuration as follows;

  1. Set up a virtual interface using the "hanetconfig create" command.
  2. Set up the standby patrol function using the "hanetconfig create" command (only if the standby patrol function is used). It is not necessary to set if a standby patrol function is already set in a virtual interface that already shares NIC.
  3. Set up the router/HUB monitoring function using the "hanetpoll create" command.
  4. Specify "plumb" to deactivate a standby interface using the "hanetparam -d" command.
  5. After creating the configuration information, activate the concerned virtual interface using the "strhanet" command.
  6. Start router/HUB monitoring function to monitor the routers/hubs using "hanetpoll on" command.
  7. Create a zone. For information on how to create a zone, see "3.2.4 Zone setup for Solaris container".
  8. Start the zone. The logical virtual interface (hme0:X) will be added to the primary interface (hme0) from the redundant physical interface (sha0). The IP address specified during zone creation will be allocated.

image


Contents Index PreviousNext

All Rights Reserved, Copyright (C) FUJITSU LIMITED 2005