Chapter 2 Feature description

2.2 Option Functions

Table 2.1 shows the option functions that can be used in each mode.

[Table 2.1 Available option functions in each mode.]

Function

Mode

Fast switching mode

RIP mode

NIC switching mode

GS/SURE linkage mode

Multiple virtual interface definition

A

A

A

A

Cluster failover because of a line failure

A

X

A

A

Concurrent operation with other modes via one virtual interface

A

A

X

X

Sharing function of physical interface

A

A

A

X

Multiple logical virtual interface definition

A

A

O

X

Single physical interface definition

A

A

A

A

Router/HUB monitoring

X

A

A

X

Communication target monitoring

O

O

X

A

Standby patrol

O

O

A

O

Automatic failback

O

O

A

O

Dynamic adding/deleting/switching of interfaces used

A

A

A

A

User command execution

X

X

A

A

[Meaning of the symbols] A: Allowed, X: Not allowed, O: Replaced by other functions


Down2.2.1 Configuring multiple virtual interfaces
Down2.2.2 Cluster fail-over when entire transfer routes fails
Down2.2.3 Operating several modes concurrently on a single virtual interface
Down2.2.4 Sharing physical interface
Down2.2.5 Configuring multiple logical virtual interfaces
Down2.2.6 Configuring single physical interface
Down2.2.7 Router/HUB monitoring function
Down2.2.8 Monitoring communicating host
Down2.2.9 Standby patrol function
Down2.2.10 Automatic fail-back function
Down2.2.11 Dynamically adding/deleting/switching physical interface
Down2.2.12 User command execution function

Contents Index PreviousNext