Top
PRIMECLUSTER Global Disk Services  Configuration and AdministrationGuide 4.7

C.2.1 Panic Messages (20000-20099)

20002

sfdsk: I/O error on last ACTIVE slice

Explanation

Caused a panic after an I/O error occurred on the only active slice in the volume.

Resolution

Disk failure may have occurred. Check if the physical disk is operating normally.


20003

sfdsk: class closed down

Explanation

Caused a panic after the class was closed.

Resolution

The following are the possibilities:

  • Disk failure.

  • An abnormality occurred in the communication between nodes in the cluster system.

Check if the physical disk and the cluster system are operating normally.


20004

sfdsksys: I/O error on last ACTIVE slice

Explanation

Caused a panic after an I/O error occurred on the only active slice in the volume.

Resolution

Disk failure may have occurred. Check if the physical disk is operating normally.


20005

sfdsksys: class closed down

Explanation

Caused a panic after the class was closed.

Resolution

Disk failure may have occurred. Check if the physical disk is operating normally.