2.3 Device Polling

The Manager checks the statuses of registered devices by using SNMP, ping or unique protocol at intervals of 60 seconds (default). It is as follows which polling method.

Polling Method

Protocol

Devices

Device status

SNMP

ETERNUS Disk storage system
NetApp FAS Series

Communication status

SNMP

PRIMERGY Fibre Channel switch blade
Brocade Fibre Channel switch
VDX series
PRIMERGY BX Ethernet Fabric Switch

unique protocol

server nodes for which Agent is installed

private protocol

VMware vSphere

ping

Devices supporting automatic detection, other than the above devices.
Manually embedded devices for which IP addresses are set.

With either SNMP or ping, Systemwalker Centric Manager linkage and Shell/bat linkage are enabled by default. The swsag code reported to Centric Manager is 4822. The linkage behavior can be modified. For information see "A.7 Device Polling Setting File".

Users can customize polling intervals, the time at which operation stops, the specification of devices to be excluded from polling operation, and other device polling functions. For details, see "A.7 Device Polling Setting File".

Note

  • When the device polling detects a change in network or device status, any event of "Device Polling Event" in the Event Guide is displayed. However, when the state change of device is detected by performing the Reload Conf. operation, the following events are not displayed. Confirm the state from Web Console.

  • In a large-scale environment in which hundreds of devices targeted for polling are registered, not all the devices may be checked within 60 seconds (default). In that case, on the next polling cycle, the devices whose statuses were not checked on the last polling cycle are given priority. The polling interval can be changed. Refer to "A.7 Device Polling Setting File" for details.