ETERNUS SF Storage Cruiser V16.9 Operation Guide
FUJITSU Storage

Preface

Purpose of This Manual

This manual describes how to use FUJITSU Storage ETERNUS SF Storage Cruiser (hereafter abbreviated as "Storage Cruiser").

Intended Readers

The manual is intended for operations managers who use Storage Cruiser for storage management.

The procedure used for actual system configuration assumes that the reader knows the basic configuration procedure for the installation target server, storage units, and their network.

Structure of This Manual

The structure of this manual is as follows.

Chapter 1 Overview

Explains the ETERNUS SF Storage Cruiser.

Chapter 2 Fault Monitoring

Explains how to detect errors occurring in the devices making up a storage system, the screen displayed for them, and how to respond to them.

Chapter 3 Operation Design

Explains LAN connections.

Chapter 4 Environment Configuration

Provides the settings and notes required for devices to be managed.

Chapter 5 Startup and Setting

Provides device definitions and operation flowcharts required for operating this product software.

Chapter 6 Operation

Explains how to use each view of the resource view and Correlation window.

Chapter 7 Performance Management

Explains performance management functions.

Chapter 8 Reporting Function

Explains reporting functions.

Chapter 9 Storage Cluster Function

Explains Storage Cluster functions.

Chapter 10 Maintenance of Devices to Be Managed

Explains the screen displayed at the occurrence of a device error and how to respond to it.

Chapter 11 Maintenance of Administrative Environment

Explains how to maintain databases and the troubleshooting required if a problem occurs.

Chapter 12 Linkage to Other Software

Explains how to link with other software.

Chapter 13 Command References

Explains how to use each command.

Appendix A Customization

Explains how to customize definition files.

Appendix B Troubleshooting

Explains basic troubleshooting and also provides information on where to find further help.

Appendix C How to Check Product Version

Explains how to check version of installed ETERNUS SF Storage Cruiser.

Appendix D Operations Other Than Operations on Switches within System Managed on Storage Cruiser

Explains the operation points in cases when managing the system configuration storage devices and servers including switches not supported by Storage Cruiser.

Conventions

Export Controls

Exportation/release of this document may require necessary procedures in accordance with the regulations of your resident country and/or US export control laws.

Trademarks

Revision History

Date of Publication

Revision

Document Part Number

PDF

HTML

May 2022

10.3

B1FW-6007-10ENZ0(03)

B1FW-6007-10ENZ2(03)

November 2021

10.2

B1FW-6007-10ENZ0(02)

B1FW-6007-10ENZ2(02)

October 2021

10.1

B1FW-6007-10ENZ0(01)

B1FW-6007-10ENZ2(01)

August 2021

10

B1FW-6007-10ENZ0(00)

B1FW-6007-10ENZ2(00)

February 2021

9.5

B1FW-6007-09ENZ0(05)

B1FW-6007-09ENZ2(05)

October 2020

9.4

B1FW-6007-09ENZ0(04)

B1FW-6007-09ENZ2(04)

July 2020

9.3

B1FW-6007-09ENZ0(03)

B1FW-6007-09ENZ2(03)

March 2020

9.2

B1FW-6007-09ENZ0(02)

B1FW-6007-09ENZ2(02)

January 2020

9.1

B1FW-6007-09ENZ0(01)

B1FW-6007-09ENZ2(01)

November 2019

9

B1FW-6007-09ENZ0(00)

B1FW-6007-09ENZ2(00)

April 2019

8.1

B1FW-6007-08ENZ0(01)

B1FW-6007-08ENZ2(01)

December 2018

8

B1FW-6007-08ENZ0(00)

B1FW-6007-08ENZ2(00)

December 2017

7

B1FW-6007-07ENZ0(00)

B1FW-6007-07ENZ2(00)

May 2017

6

B1FW-6007-06ENZ0(00)

B1FW-6007-06ENZ2(00)

October 2016

5

B1FW-6007-05ENZ0(00)

B1FW-6007-05ENZ2(00)

June 2016

4.3

B1FW-6007-04ENZ0(03)

B1FW-6007-04ENZ2(03)

April 2016

4.2

B1FW-6007-04ENZ0(02)

B1FW-6007-04ENZ2(02)

December 2015

4.1

B1FW-6007-04ENZ0(01)

B1FW-6007-04ENZ2(01)

October 2015

4

B1FW-6007-04ENZ0(00)

B1FW-6007-04ENZ2(00)

July 2015

3.2

B1FW-6007-03ENZ0(02)

B1FW-6007-03ENZ2(02)

March 2015

3.1

B1FW-6007-03ENZ0(01)

B1FW-6007-03ENZ2(01)

January 2015

3

B1FW-6007-03ENZ0(00)

B1FW-6007-03ENZ2(00)

July 2014

2.1

B1FW-6007-02ENZ0(01)

B1FW-6007-02ENZ2(01)

June 2014

2

B1FW-6007-02ENZ0(00)

B1FW-6007-02ENZ2(00)

May 2014

1.3

B1FW-6007-01ENZ0(03)

B1FW-6007-01ENZ2(03)

April 2014

1.2

B1FW-6007-01ENZ0(02)

B1FW-6007-01ENZ2(02)

March 2014

1.1

B1FW-6007-01ENZ0(01)

B1FW-6007-01ENZ2(01)

December 2013

1

B1FW-6007-01ENZ0(00)

B1FW-6007-01ENZ2(00)

Notes

Copyright Notice

Copyright 2013-2022 FUJITSU LIMITED

Update History

Content of Update

Updated Section

Revision

Information related to the following software has been added.

  • Microsoft Windows Server 2022

Information related to the following devices has been deleted.

  • Switches that Fabric OS v6.2 or earlier is installed

General

10.3

Information related to the following storage devices has been added in Step 1 of "Registering ETERNUS Disk Storage Systems and License".

  • ETERNUS DX S4 series (excluding the ETERNUS DX8900 S4) and ETERNUS AF S2 series that have firmware version V10L90-2000 or later

9.4.1

10.2

Information related to the VE ports of the Brocade 7810 has been added.

4.2.1

10.1

Information related to displaying data access state of the RAID group during redundancy loss has been added.

6.1.1

Information related to the following storage devices has been added.

  • ETERNUS DX S4/S3 series (excluding the ETERNUS DX8900 S4), ETERNUS AF S2 series, AF series, or ETERNUS DX200F that has firmware version V10L90-1000 or later

9.4.2.6, 9.4.2.8, 9.4.2.9, 9.4.3

Information related to the following device has been added.

  • ETERNUS CS800 M1

Information related to the following devices has been deleted.

  • ETERNUS VS850 S2

  • ETERNUS CS800 S5/CS800 S4

  • NetApp V-Series

  • Tintri VMstore series

In addition, unnecessary description has been deleted.

General

10

The product overview article has been deleted from this manual because it was moved to the Overview.
in addition, unnecessary description has been deleted.

Information related to Red Hat Enterprise Linux 8 has been added.

3.2

The content of "Unit of Eco-mode Control" that was described in section 1.2.5 of the previous version has been moved.

3.4

[Point] has been added.

4.1.7

In response to the migration of the "Problem-handling (FAQ)" section to Appendix B.4, reference destinations have been updated.

4.1.7.1, 10.1

The "Problem-handling (FAQ)" section has been moved to Appendix B.4.

4.1.7.2, 4.2.1.3, 4.2.3.1.3, 4.3.1.2

In [Note], the explanation has been modified.

4.2.1.1

The content of "Concerns in Storage System Operation When Using Eco-mode" that was described in section 1.2.5 of the previous version has been moved.

6.1.6.1

The contents of the table have been modified.

6.2.2.1

A description to indicate that the operations are performed only when instructed by your maintenance engineer has been added.

9.4.2.7

New sections have been added.

9.4.2.8, 11.1.2.12, B.4

The description has been added in the "Maintenance" of the table "Phase".

9.4.2.9

The procedure has been modified.

9.4.3.10

The descriptions related to the operation and maintenance of Storage Cluster have been improved.

9.4.2, 9.4.3

9.5

Information related to Red Hat Enterprise Linux 8 has been added or modified.

1.2.9, 4.4, 13.3.3.1

9.4

The paragraph "When Managing with Products That Use the RESTful API of the Storage Device" has been added.

3.4

Information related to the ETERNUS DX S5 series, DX8900 S4, and ETERNUS AF S3 series whose firmware version is V11L40 or later has been added.

6.1.3, 6.4.1, 7.1.1

In [Note], the term "Veeam" has been changed to "Veeam Storage Integration".

6.1.5

In "Threshold Values and Threshold Monitoring Status", the meaning of the displayed icons has been described. In addition, the explanation of "Action to Take When Threshold Values Are Exceeded" has been modified.

6.4.1

The explanation has been modified or added.

7.2.9, 11.1.2.8

[Point] has been added in step 1 of "Registering ETERNUS Disk Storage Systems and License".

9.4.1

In [Note] of "Configuring TFO Group", the explanation has been added.

9.4.1

The organization of this section have been reviewed and the explanation of the business volume allocation procedure using Web Console has been added.

9.4.2.1

In "Configuring Access Path (When Allocating Volumes to Each Storage or When Adding Secondary Storage Where Only Primary Storage Is Used)", the bullet "About the host affinity setting when Veeam Storage Integration is used" has been added.

9.4.2.1

In [Point], the explanation has been added.

9.4.2.6

[Information] has been added.

12.2

[Note] has been deleted.

Appendix E

Information related to the following devices has been added.

  • ETERNUS AX/HX series

  • ETERNUS AB/HB series

General

9.3

Descriptions related to unsupported devices and devices with support level I have been modified or deleted.

1.2.9, 2.1, 2.2, 2.4, 10.1, A.1, A.5

Information related to the role group configuration file has been added.

11.1.1.2.3, 11.1.1.2.4, 11.1.1.3.3, 11.1.1.3.4

Information related to expanding the event messages of the threshold monitoring alarm has been added.

7.1.3, 7.2.2, 7.3.6, 7.5, A.4

9.2

Information related to the following device has been added.

  • ETERNUS DX900 S5

General

9.1

The URL address of the SNIA HBA API Library Installation Guide has been modified.

4.1.1.1, 4.1.2.1, 4.1.3.1

Information related to Model Upgrade from the following devices has been added.

  • ETERNUS DX60 S5

  • ETERNUS DX100 S5

  • ETERNUS DX200 S5

  • ETERNUS DX500 S5

  • ETERNUS AF150 S3

  • ETERNUS AF250 S3

11.1.2.8

Information related to the following devices and software has been added.

  • ETERNUS DX S5 series (excluding the ETERNUS DX900 S5)

  • ETERNUS AF S3 series

  • Red Hat Enterprise Linux 8 (for Intel64)

  • SUSE Linux Enterprise Server 15 for AMD64 & Intel64

  • SUSE Linux Enterprise Server 12 Service Pack 4 for AMD64 & Intel64

Information related to the following devices and software has been deleted.

  • ETERNUS DX60, DX400 series, DX8000 series

  • ETERNUS SN200 series

  • ETERNUS VS850

  • ETERNUS CS800 S3/CS800 S2/CS800

  • ETERNUS LT20, LT40, LT60, LT200, LT210, LT220, LT230, LT250, LT270

  • Microsoft Windows Server 2008 R2

  • Microsoft Windows Server 2008

  • Red Hat Enterprise Linux 5 (for x86)

  • Red Hat Enterprise Linux 5 (for Intel64)

  • SynfinityDISK

General

9

The description for Conventions has been changed so that the FUJITSU Storage ETERNUS SF Express / Storage Cruiser / AdvancedCopy Manager Documentation Road Map is referenced.

"Conventions" in Preface

The "Manual Organization and Reading Suggestions" section has been deleted from Preface.

Preface

In the table "Support Levels", information of the support level B has been modified.

1.2.9

Information related to SUSE Linux Enterprise Server 12 has been modified.

3.2

The explanation has been added.

4.2.3

In [Note], the explanation has been added.

4.5, 7.3.4

In 1st [Note], the explanation has been modified.
In addition, in [Note] under "For Hyper-V (Windows, Only for Manager)", the explanation has been modified.

6.1.7

In [See], the explanation has been modified.

6.3

In "Systemwalker Centric Manager Linkage", the explanation about events of transition of the Thin Provisioning Pool using rate and reduction of Thin Provisioning Pool's capacity has been added.

6.3

The section title has been changed.

7.2.6.7

In [Point], the explanation has been added.

7.2.9

In [Note] of "Automatic Failover", the explanation has been modified.

9.2

Explanation related to starting and stopping the ETERNUS SF Manager services/daemons has been modified.

13.3.1 - 13.3.3

[Note] has been added.

Appendix E

The description of step 1 has been modified.

Appendix E

Information related to Microsoft Windows Server 2019 has been added.

"Notation" and "Others" in Preface, 3.1.1, 3.2

8.1

Information related to the ETERNUS LT140 has been added.

"Notation" in Preface, 1.2.9, 4.7.2, 12.1.4.2, A.5

Information related to the ETERNUS CS800 S7/CS800 S6/CS800 S5/CS800 S4 has been added.

1.2.9, 4.6

Information related to the Brocade 7810 has been added.

4.2.1.3

In [Note], the explanation has been added.

6.1.5

[Note] has been added in "Automatic Failover".

9.2

The description about Veeam has been added in "Preparing Business Volume". In addition, the explanation in "Confirming Configuration" has been modified.

9.4.2.1

In [Note], the description about Veeam has been added.

9.4.2.3

The explanation of step 4 in "If the pre-replaced switch model and the post-replaced switch model are different" has been modified.

10.2.4

The explanation of step 2 and [Note] has been modified.

12.1.4.1

The explanation for the -dir option has been modified.

13.1.1.9

The explanation of the work procedure has been modified.

B.3.1, B.3.2

Information related to the ETERNUS DX8900 S4 has been added.

"Notation" and "Others" in Preface, 3.1.1, 3.4, 6.1.2 - 6.1.4, 6.1.8, 7.1.1, 7.2.3, 7.2.6.7, 9.4.1, 12.2, 13.1.1.5, 13.1.1.6, 13.1.2.2, 13.1.2.7, A.5

8

Notation related to VDX has been modified.

"Others" in Preface, 1.2.9, 2.3, 3.1.1, 3.1.2, 4.2.3, 4.2.3.1.1 - 4.2.3.1.3, 4.2.3.2, 5.2.3, 11.1.2.9, 12.1.4.2, 13.1.1.2, 13.1.1.4, A.5

Information related to Solaris 9 has been deleted.

"Notation" in Preface, 3.2, 5.2.2, 6.2.3.2

7

Information related to the ETERNUS DX500 S4/DX600 S4 has been added.

"Notation" in Preface, 3.1.1, 6.6.1.5, 7.1.1, 7.2.3, 11.1.2.8, 12.2, A.5

Information related to the ETERNUS AF250 S2/AF650 S2 has been added.

"Notation" in Preface, 1.2.5, 1.2.6, 1.2.9, 2.5, 3.1.1, 3.1.2, 4.3.1, 4.3.1.1, 4.3.1.2, 5.2.2, 5.2.3, 5.3, 6.1.3, 6.1.5, 6.2.1, 6.2.3, 6.2.3.1, 6.6, 7.1.1, 7.2.3, 8.2, 11.1.2.9, 11.1.2.11, 11.2.3.3, 12.1.4.2, 12.1.4.3, 12.2, 13.1.1.5, 13.1.1.6, 13.1.2, 13.1.2.2 - 13.1.2.4, 13.1.2.7, A.5

The description related to the expansion of platforms that support Storage Cluster Controller has been modified or added.

4.1.1, 4.1.3, 11.2.3.3, 11.3.3.3, 11.4.2.3, 13.2.4, A.12

In [Note], the explanation has been modified or added.

4.2.1.1, 4.2.1.3, 4.9, 6.1.1, 6.1.2, 7.2.3, 9.4.2.3, 10.3.1

"Recovering for Performance Monitoring Status of Device Is Displayed" has been added in FAQ.

4.2.1.3

Information related to the NetApp AFF A series has been added.

4.4, 10.1, 12.1.4.2, A.5

[Point] has been added.

5.2.7, 6.2.3.2, 9.4.2.1

The description related to the SNMP Trap test has been deleted.

5.3

The description of "Checking Storage Settings" has been modified.

6.2.3.1

A note for CA and CM Port has been added.

7.1.1

In "Target", the description related to the Non-disruptive Storage Migration function has been added.

8.1.3

The explanation in "Preparing Business Volume" has been added.

9.4.2.1

The explanation in "Configuring Access Path" has been modified and added.

9.4.2.1

In the note for "CA/CM Port Performance Information of Storage Device", the explanation related to the performance information of the FC-Initiator port has been added.

13.1.1.6

NOTES has been added.

13.1.2.1

IN NOTES, the description has been added.

13.1.2.2 - 13.1.2.4

The EXAMPLES has been modified.

13.2.4

In the table A.1, the SNMP Trap XML definition file for checking the settings for SNMP Traps from the Storage Cruiser's agent has been added.

A.5

The explanation for "HBAMask" has been modified.

A.6

Information related to Microsoft Windows Server 2016 has been added.

"Notation" and "Others" in Preface, 3.1.1, 3.2

6

Information related to Windows Vista has been deleted.

"Notation" in Preface

Information related to SUSE Linux Enterprise Server 11 has been deleted and information related to SUSE Linux Enterprise Server 12 for AMD64 & Intel64 has been added.

"Notation" in Preface, 3.2, 4.1.3.3

Information related to the ETERNUS DX60 S4/DX100 S4/DX200 S4 has been added.

"Notation" in Preface, 1.2.5, 1.2.6, 1.2.9, 2.5, 3.1.1, 4.3.1.1, 5.2.2, 5.2.3, 6.1.3, 6.1.5, 6.2.1, 6.2.3.1, 6.6.1.5, 7.1.1, 7.2.3, 8.2, 11.1.2.8, 12.2, 13.1.1.5, 13.1.1.6, 13.1.2, 13.1.2.2 - 13.1.2.4, 13.1.2.7, A.5

ETERNUS Multipath Driver has been added to the middleware that can be managed in a Solaris 11 environment.

3.2

The task required when you use the beacon function has been added.

4.2.1.1

The section title has been changed.

5.3

In [Information], one sentence has been deleted.

5.3

In [Note], the explanation has been modified or added.

6.1.2, 6.1.3, 6.1.7, 9.4.1, 9.4.2.3, 13.3.1.1

[Point] has been added.

6.1.3, 9.2, 9.4.1, 9.4.2.1

Information has been added in "Notes".

6.2.3.1

In [Note], information related to the Brocade X6-4/X6-8 has been added.

7.2.3

The figure "Behavior of Automatic Failover When CA Port Is Linked Down (for FC Configuration)" has been added.

9.2

The description about releasing/recovering a TFO pair has been added.

9.2

In the table "Timing of Automatic Failover Operation", "*1" has been added to #8.

9.2

The condition about ports for connecting to a business server has been modified. In addition, information on how to expand the total capacity of TFOVs has been added.

9.4.1

The condition about preparing business volumes has been added.

9.4.2.1

The description about expanding the capacity of the business volume capacity has been added.

9.4.2.4

New sections have been added.

9.4.2.5, 9.4.3.4, 9.4.3.7, 9.4.3.8, 11.1.2.11

The strings that are displayed in Phase and Status has been changed.

9.4.2.8

In the step (a) of the table 9.7, information that the -force option is required for the acopc cancel command when using QuickOPC has been added.

9.4.3

In the step (e) of the table 9.7, the procedure when using OPC/QuickOPC has been modified.

9.4.3

The operation procedure has been modified.

9.4.3.1 - 9.4.3.3, 9.4.3.5, 9.4.3.6, 9.4.3.10

The procedure for backup and restoration has been modified.

11.1.1.2.1, 11.1.1.2.3, 11.1.1.3,1, 11.1.1.3.3

The description has been modified so that Microsoft Windows Server 2016 is listed.

11.1.2.10, 13.3.1.1, 13.3.1.2, 13.4.1

In NOTES, the description of the LUN concatenated volume has been deleted.

13.1.2.3, 13.1.2.4

In the table A.1 and A.2, information about Device-Mapper Multipath in the Linux environment has been added.

A.5

Information related to HP-UX 11i v1/v2 has been deleted.

"Notation" in Preface, 3.2

5

Information related to VMware vSphere 4 has been deleted.

"Notation" in Preface, 1.2.9, 2.1, 2.3, 3.1, 4.1.7, 5.2.2, 5.2.4, 5.3, 6.2.1, 6.2.3, 6.2.3.2, 6.2.4, 6.2.4.2, 10.3.1, 11.1.2.9

Information related to the ETERNUS DX80/DX90 has been deleted.

"Notation" in Preface, 1.2.5, 1.2.9, 3.1.1, 4.3.1.1, 4.3.1.2, 5.2.2, 6.1.5, 6.1.9, 6.2.3.1, 7.1.1, 7.2.2, 7.2.3, 11.1.2.8, 12.2, 13.1.1.5, 13.1.1.6, 13.1.2, 13.1.2.2 - 13.1.2.4, 13.1.2.6, 13.1.2.7, A.5

Information related to the ETERNUS AF250/AF650 has been added.

"Notation" and "Others" in Preface, 1.2.5, 1.2.6, 1.2.9, 2.5, 3.1.1, 3.1.2, 4.3.1, 4.3.1.1, 4.3.1.2, 5.2.2, 5.2.3, 5.3, 6.1.3, 6.1.5, 6.2.1, 6.2.3, 6.2.3.1, 6.6, 7.1.1, 7.2.3, 8.2, 11.1.2.9, 12.1.4.2, 12.1.4.3, 12.2, 13.1.1.5, 13.1.1.6, 13.1.2, 13.1.2.2 - 13.1.2.4, 13.1.2.7, A.5

Information related to the ETERNUS LT60 has been deleted.

"Notation" in Preface, 1.2.9, 4.7.2, 12.1.4.2, A.5

The description of the antivirus function has been deleted.

"Software Products" in Preface, 6.6

[Point] has been added.

1.2.2, 6.5.5

The explanation related to automatic updates of the device component status has been added.

1.2.2, 1.2.9, 2.2, 2.5, 5.2.3, 5.2.4, 10.1

In [Note], the explanation has been modified or added.

4.2.1.3, 6.5.1.4, 6.5.1.5, 7.1.1, 10.3.1

The explanation has been separated into the automatically detectable devices and the manually detected devices.

4.2.3

The term "Deduplication" has been changed to "Deduplication/Compression". In addition, the explanation related to Deduplication/Compression has been added.

6.1.3

The explanation of "Migration of Virtual Machine" has been modified.

6.1.10

In [Point], the explanation has been added.

6.5.1.2, 6.5.1.3, 7.2.9

New section has been added.

6.5.1.7

The explanation for the setting item has been added.

7.3.3

The explanation of "Minimum Threshold Monitoring Interval" has been added.

7.3.4

The explanation to use the Storage Cluster function in an iSCSI environment has been added.

9.1 - 9.3, 9.4.1, 9.4.2.1, 9.4.3.1, 9.4.3.6, 9.4.3.7, 13.1.1.5, 13.1.2.6, 13.1.2.7

The explanation of the requirement that is described in "Preparing Business Volume" has been modified.

9.4.2.1

The procedure is modified.

11.1.1.3.1, 11.1.1.3.3

Information related to Model Upgrade from the ETERNUS DX200 S3 to the ETERNUS DX500 S3 has been added.

11.1.2.8

The bit7 and bit8 have been added in flag attribute of TrapType tag.

A.5

The explanation related to the event notification setting of SNMP Traps has been added.

A.8

The description related to email has been deleted.

B.1, B.2

In [Point], information has been added.

6.6.1.1.1

4.3

The explanation related to home directory has been added.

6.6.1.1.3, 6.6.1.5.1, 6.6.4.1 - 6.6.4.3, 6.6.4.28

In [Information], the explanation has been modified.

6.6.1.2.1

The unit that can set quota has been described.

6.6.1.4.1, 6.6.4.16

The explanation about a local user/local group for connecting to NAS has been added.

6.6.2.1, 6.6.2.2, 6.6.3.3

The description of the following items has been added:

  • Usage

  • Access Configurations of Shared Folder

  • Host Access Configurations of Shared Folder

6.6.3.1

"Hosts Allowed Access with root privilege" has been added to the item that can change the setting.

6.6.4.3

Information related to the encryption mode AES-256 has been added.

6.1.9

4.2

Information related to the quota settings has been modified or added.

6.6.1.1.2, 6.6.1.4.1, 6.6.3.1, 6.6.4.16 - 6.6.4.21

4.1

The explanation related to the NAS file system has been modified.

6.6.1.1.3

Information related to the snapshots has been modified or added.

6.6.1.3, 6.6.4.10, 6.6.4.13, 6.6.4.14

Point has been added to "Creating RAID Groups".

6.6.2.5

Information related to the shared folders has been modified or added.

6.6.3.1, 6.6.4.2, 6.6.4.3

Information related to the ETERNUS DX8700 S3/DX8900 S3 has been added.

11.1.2.8

Information related to Microsoft Windows Server 2003 has been deleted.

"Notation" in Preface, 3.2, 5.2.1, 6.2.3.2, 11.3.1, C.1

4

Information related to Windows 10 has been added.

"Notation" in Preface

The description related to SNMP communication has been modified or added.

1.2.9, Chapter 2, 2.1, 3.1.1, 3.1.2, 3.3.1, 4.1.1 - 4.1.3, 4.2.1.1, 4.2.1.3, 4.2.3.1, 4.2.3.3, 4.3.1.1, 4.3.1.2, 4.8, 5.2.1 - 5.2.3, 5.2.6, 5.3, 6.1, 11.1.2.6, 11.1.2.10, 13.1.1.1 - 13.1.1.3, 13.2.5, 13.3.1.1, 13.3.3.1, A.5

Information related to disk storage system management has been added.

3.4

Information related to the SNMPv3 protocol has been modified or added.

4.2.1.1, 4.2.3.1, 7.2.3, 11.1.2.10, Appendix F

Information related to the Thin Provisioning has been added.

6.1.3

Information related to the Dashboard has been added.

6.1.3, 6.3, 6.4.1, 6.4.2, 6.4.2.1, 6.5.1.6, 6.5.2, 6.5.2.1, 6.5.6, 6.6.1.1.2, 11.1.1.2.1, 11.1.1.3.1, 11.1.1.3.3, A.8

A note has been modified or added.

6.1.5, 13.1.2.3, 13.1.2.4

A reference destination of the specifiable items has been added.

6.5.1.1, 6.5.1.2, 6.5.3.1

"Access Status Chart Settings of One Layer Tier Pool" has been added.

6.5.1.6

Information has been added.

6.5.5

Figure "Backup/Restoration of NAS Volume" has been modified.

6.6.1.2.1

The explanation related to the shared folder has been modified.

6.6.1.2.2, 6.6.3.1

Information related to the NAS backup has been modified or added.

6.6.4.9, 6.6.4.23, 6.6.4.24

The explanation of the monitoring interval has been modified.

7.2.3

The explanation of the threshold setting information has been modified.

7.3.4

The restoration procedure when the report creation command is abnormal has been added.

8.3.4.3, 13.5.2

The explanation of the access path configuration has been modified.

9.4.2.1

The explanation of the monitoring target device configuration has been modified.

9.5.2

An unnecessary description has been deleted.

11.1.1.2.1, 11.1.1.2.3, 11.1.1.3.1, 11.1.1.3.3

The explanation for changing the configuration of the support device has been modified.

11.1.2.8

The location of the log file has been modified.

A.3

Information related to the ETERNUS DX8700 S3/DX8900 S3 has been added.

"Notation" in Preface, 1.2.5, 3.1.1, 7.1.1, 7.2.3, 13.1.1.5, 13.1.1.6, 13.1.2.2, 13.1.2.7, Appendix A

3.2

Information related to the NetApp FAS Series and V-Series has been added.

"Notation" in Preface, 1.2.9, 4.4, 5.2.6, 10.1, 12.1.4.2, 13.1.2.9, A.5

The explanation of the Tier pool setting has been modified.

6.5.1

The description of the upper limit of Tier pools that can be managed by Automated Storage Tiering has been added.

6.5.5

Method to identify CM or CM CPU of the ETERNUS Disk storage system from performance information collected by Systemwalker Service Quality Coordinator has been described.

12.2

The term "VMware Virtual Volumes" has been changed to "VMware vSphere Virtual Volumes" according to the terms used by VMware, Inc.

Throughout this manual

3.1

Information related to VMware vSphere(R) 6 has been added.

"Notation" in Preface

The explanation of "VMware Server Node" has been added.

4.1.7

The method to deal with changed environment has been modified.

4.1.7.2

The description of access paths that should be removed separately has been added.

5.2.3

The description of devices targeted for encryption has been deleted.

6.1.2

"Encryption Mode Management" has been added.

6.1.9

"Virtual Machine Management" has been added.

6.1.10

The explanation of VMware vSphere Virtual Volumes Environment Access Path has been modified.

6.2.1

The explanation of a VVOL metadata stored volume has been added.

7.1, 7.2.2

Note has been modified.

7.2.2

Procedure for backup/restoring of Storage Cruiser's manager has been modified.

11.1.1.2.1, 11.1.1.2.3, 11.1.1.3.1, 11.1.1.3.3, 11.1.1.3.4

Note has been added.

A.4

Antivirus server has been added.

"Software Products" in Preface

3

Information related to the ETERNUS DX200F has been modified or added.

"Others" in Preface, 1.2.6 to 1.2.8, 3.1, 3.2, 4.3.1, 4.3.1.1, 4.3.1.2, 5.2.1, 5.2.2, 5.3, 6.1.5, 6.2.1, 6.2.3, 6.2.3.1, 6.6.1.5, 7.1.1, 7.2.3, 8.2, 11.1.2.9, 12.1.4.2, 12.1.4.3, 13.1.1.5, 13.1.1.6, 13.1.2, 13.1.2.2 to 13.1.2.4, 13.1.2.7, A.5

Information related to the ETERNUS DX60 S3 has been added.

"Notation" in Preface, 1.2.5, 1.2.6, 3.1.1, 4.3.1.1, 4.3.1.2, 5.2.1, 5.2.2, 6.1.5, 6.2.3.1, 7.1.1, 7.2.3, 8.2, 13.1.1.5, 13.1.1.6, 13.1.2, 13.1.2.2 to 13.1.2.4, 13.1.2.7, A.5

Information related to the ETERNUS LT260 has been added.

"Notation" in Preface, 1.2.9, 4.7.2, 12.1.4.2, A.5

An explanation of VMware Virtual Volumes has been added.

1.1, 1.2.8, 4.1.7.1, 6.2.1, 11.1.1.3.3~11.1.1.3.4, 13.1.1.4, 13.1.1.9, 13.1.2.3

The information related to Red Hat(R) Enterprise Linux(R) AS v.4 and Red Hat(R) Enterprise Linux(R) ES v.4 has been deleted.

3.2, 5.2.1

The information related to Red Hat(R) Enterprise Linux(R) 7 has been added.

3.2, 13.3.3.1, A.10

An explanation of the switch management has been added.

3.3, 4.2.1.1, 4.2.3.1, 4.2.5.1, 5.2.2, Appendix E

The description related to the community setting in SNMP (Agent) environment settings has been modified.

4.3.1.1

An operation has been added to resource management.

6.1.2, 6.1.3, 6.1.9, 13.1.2.2, 13.1.2.3, 13.1.2.4, 13.1.2.6

Notes on the host group and the port group have been added.

6.2.1

Start/stop of Tier pool balancing has been added.

6.5.1.4, 6.5.1.5

Antivirus has been added to the NAS environment.

6.6.1.1.2, 6.6.1.5, 6.6.1.6, 6.6.2.4, 6.6.4.18, 6.6.4.19, 6.6.4.20, 6.6.4.24

Performance management has been added to NAS volume and NAS system.

6.6.1.1.2, 6.6.4.21, 7.1.1, 7.2.6.6, 13.1.1.6

"Copy Table Size Settings" has been added.

6.6.2.5

The SMB encryption of the data access and the enumeration based on the access permission setting has been added.

6.6.3.1, 6.6.4.2

"Access Using NFS Protocol" has been changed.

6.6.4.1

Note on the "Deleting Shared Folder" has been added.

6.6.4.24

Table in case of the ETERNUS Disk storage system has been adjusted.

7.1.1

Attention regarding display of performance information has been changed.

7.1.1

The description related to the method of selecting the scope of monitoring volumes has been added.

7.2.2, 7.2.9

"Failover mode" has been added.
Input conditions for TFO Group name have been described.
The conditions for the REC Path interface type have been described.

9.2

Operation of the Storage Cluster function has been added.

9.2, 9.4.1, 9.4.2.1, 9.4.2.2, 9.4.2.4, 9.4.2.6

Description of the Storage Cluster function has been corrected.

9.4.1, 9.4.2.1, 9.4.2.6, 9.4.3

Procedure for confirming settings when allocating the business volume has been corrected.
Reference to access state data synchronizing has been added.

9.4.2.1

The description related to backup/restoring of Storage Cruiser's manager has been modified.

11.1.1.2.1, 11.1.1.2.5, 11.1.1.3.1, 11.1.1.3.3

The explanative article on the -ipaddr option of the "setagtip command" has been changed.

13.2.1

The example of outputting VERSION verify information has been changed.

C.2, C.3

Note has been added.

6.6

2.1

The number of NAS volumes and NAS backup volumes creatable on one ETERNUS Disk storage system has been changed.

6.6.1.2.1

Note has been added when data inconsistency is found in a snapshot.

6.6.1.3.1, 6.6.4.12

Point has been added to "NAS Environment Quota Management".

6.6.1.4.1

Point has been added to "Events Notified by Quota Management".

6.6.1.4.2

Note has been added to "Registration of User/Group".

6.6.2.2

Note when using quota management function and snapshot function has been added.

6.6.2.4, 6.6.3.1, 6.6.4.10, 6.6.4.15

"NAS Volume Number to Which to Create Shared Folder" has been added.
Method for specifying time to collect snapshots has been added.

6.6.3.1

Suffix of volume name has been changed. The limit to the number of volume name characters has been deleted.

6.6.3.1, 6.6.4.9

Mode number has been added.
Point has been added to "Port Bonding".
Note has been added to "NAS Interface (Network)".
Note has been added to "VLAN ID".

6.6.3.2

Point has been added to "Removing Authentication Server".

6.6.4.21

Storage Cluster function has been added.

1.1, 1.2, 1.3, 3.1.1, 4.1.2, Chapter 9, 10.2.2, 10.2.6, 12.2.4, A.1, A.6, A.12

2

Description of Eco Mode has been modified.

1.2.5, 6.1.6, 7.1.1, 12.1.1.7, 12.1.2.2

Port number used for Manager communication has been changed.

3.1.1

SSH login has been added.

3.1.1, 4.2.1.1, 4.2.1.3, 4.2.3.3, 5.2.2, 6.2.6, 10.2.4

Zoning setting example has been deleted.

4.2.1.2

Zoning setting has been modified.

4.2.5.1

Action (FAQ) has been added.

4.2.5.3

Description of invalid password status of ETERNUS system has been deleted.

4.3.1.1, 13.1.1.4, 13.1.1.5, 13.1.1.7, 13.1.2

Operating systems to be searched with IPv4 address alone have been specified.

5.2.1

Notes when deleting devices have been added.

5.2.3

Notes have been added.

6.1.2, 6.1.3, 6.1.5

Considerations have been added.

6.2.3.1

Capacity management of Tier pool has been added.

6.5, A.8

Function has been added to the NAS management.

6.6

"RAID6-FR" has been added to type of RAIDGroup.

8.4

Target devices have been added to replacement of fibre channel switch devices.

10.2.4

Backup/restore procedure of Manager for Windows/Solaris in a cluster environment has been changed.

11.1.1.2.2, 11.1.1.2.6, 11.1.1.3.2, 11.1.1.3.6

Backup/restore of Windows Manager has been deleted.

11.1.1.2.5, 11.1.1.3.5

Method to change port numbers of Management Server/Server node has been added.

11.1.2.5, 11.2.3.2, 11.3.3.2, 11.4.2.2, 11.5.2.2

Error in command name has been corrected.

13.1.1.1

Command output result has been added.

13.1.1.4

Examples in Solaris/Linux environments have been changed.

13.1.1.6, 13.1.1.9

Description when the -dir option is omitted in Solaris environment has been changed.

13.2.3

Notes when collecting troubleshooting information in a cluster configuration system have been added.

B.1

Information related to the ETERNUS DX200F has been added.

"Others" in Preface, 1.2.5, 6.6, 6.6.1.3, 7.1.1, 13.1.1.6, 13.1.2

1.3

Operating environment has been changed.

6.6.1.3

1.2

Notes when creating a NAS interface have been added.

6.6.3.2

1.1

Notes when setting up an authentication server have been added.

6.6.3.3

The access method by CIFS protocol has been changed.

6.6.4