Top
PRIMECLUSTER Global Link Services Configuration and AdministrationGuide 4.6Redundant Line Control Function
FUJITSU Software

7.8 dsppoll Command

[Name]

dsppoll - Displaying the monitoring status

[Synopsis]

/opt/FJSVhanet/usr/sbin/dsppoll

[Feature description]

The dsppoll command displays the current monitoring status of monitoring information created using the hanetpoll command.

[Display format]

The following shows the display format used when no option is specified.

# /opt/FJSVhanet/usr/sbin/dsppoll
 Polling Status    =  ON
 interval(idle)    =   5( 60)
 times             =   5
 link detection    = YES
 FAILOVER Status   = YES

 Status  Name  Mode Primary Target/Secondary Target             HUB-HUB
+------+------+----+-------------------------------------------+-------+
   ON   sha0    d   192.168.74.2(ON)/192.168.74.3(WAIT)          ACTIVE
   ON   sha1    d   fec0:1::100(ON)/fec0:1::101(WAIT)            ACTIVE
   ON   sha2    d   ----(ON)/----(WAIT)                          OFF

Display

Contents

Polling Status

ON

The monitoring function is enabled.

OFF

The monitoring function is disabled.

interval (idle)

interval

In seconds the monitoring interval in the stationary status.

(idle)

In seconds the wait time that elapses after monitoring starts and before the HUB links up.

times

The monitoring count.
Cannot be used if monitoring is not performed by ping command.

link detection

YES

The link detection function is enabled.

NO

The link detection function is disabled.

FAILOVER Status

YES

Node switching is performed when the virtual interface is registered in the cluster resource.

NO

No node switching is performed.

Status

ON

Monitoring is in progress.

OFF

Monitoring is stopped.

Name

The name of a virtual interface to be monitored.

Mode

d

NIC switching mode (logical IP address takeover function)

e

NIC switching mode (physical IP address takeover function)

Primary Target/
Secondary Target

Monitoring status in Primary/Secondary monitor-to IP address or a host name and parenthesis.

(ON)

Monitoring is in progress.

(WAIT)

Waiting is in progress.

(FAIL)

Monitoring failed (monitoring is stopped).

(STOP)

Unused.

HUB-HUB

WAIT

HUB-to-HUB monitoring has stopped.

ACTIVE

HUB-to-HUB monitoring is operating.

FAIL

HUB-to-HUB monitoring has failed.

OFF

HUB-to-HUB monitoring is unused.

[Related commands]

hanetpoll

[Notes]

If no option is specified, this command can be specified for a virtual interface in NIC switching mode (operation mode "d" or "e").

[Examples]

The following shows an example of displaying all the monitoring statuses properly defined using the hanetpoll command.

# /opt/FJSVhanet/usr/sbin/dsppoll