4.4 jobschcod Command

Synopsis

[To set/change]
jobschcod day change time [-sys subsystem number]
[To cancel]
jobschcod -off -sys subsystem number

Description

The jobschcod command changes the day change time.

Options

day change time

The day change time is set. Specify this option in the format "hhmm" in four digits. "hh" is set in a range "from 00 to 23" (hour) and "mm" is set in a range "from 00 to 59" (minute).

Example Setting

The following shows an example where the day change time is set to 9.05 a.m.

jobschcod 0905

Enterprise Edition-sys subsystem number

Specifies the target subsystem in a system that is operating multiple subsystems. Specify a subsystem number from 0 to 9. If you omit this option when setting or changing the day change time, the command will apply to the system day change time.

-off

Cancels the day change time setting for the specified subsystem number.

Command Location

Windows

Systemwalker Operation Manager installation directory\MpWalker.JM\bin

Solaris
HP-UX
AIX
Linux

/usr/bin

Privilege Required

System administrator (user belonging to the Administrator group or superuser) privileges are required.

Cautions