7.4.1 Corrective Action in the event of a resource failure

This section describes the corrective actions to take when a resource failure occurs.

7.4.1.1 Failure Detection and Cause Identification if a Failure Occurs

If a failure occurs in a resource, you can use the functions of PRIMECLUSTER and the operating system to detect the failure and identify the faulted resource that caused the failure.

The descriptions given in (a) to (g) below are relevant to the "Failure confirmation features list" given below:

Failure detection

Normally, the RMS main window (a) is used to monitor the cluster applications.

In addition, you can use the features described in "Failure confirmation features list" to detect the failure.

Cause identification

You can also use the function that detected the failure and the features listed in "Failure confirmation features list" below to identify the faulted resource that caused the failure.

Failure confirmation features list

Failure confirmation features

Manual reference

(a)

RMS main window
The RMS tree and the RMS cluster table can be used from this screen.

7.1.3 RMS Main Window

(b)

CF main window
The CF tree can be used from this screen.

7.1.1 CF Main Window

(c)

MSG main window
The cluster control messages can be viewed in this screen.

To display this screen, select the msg tab in the Cluster Admin screen.

-

(d)

Application log

7.3.4.2 Viewing application logs

(e)

switchlog

7.3.4.1 Viewing switchlogs

(f)

Syslog

-

(g)

Console*
Messages that are displayed on the console or Syslog can be checked.

PRIMECLUSTER Messages

(h)

GDS GUI

PRIMECLUSTER Global Disk Services Configuration and Administration Guide

*Console

Note

When you check the message of a resource failure, a resource with the "MONITORONLY" attribute may be in the fault state even if the cluster application is in the Offline state. Check whether there are any resources in the fault state. Especially, check that Fsystem resources are not in the fault state.

7.4.1.2 Corrective Action for Failed Resources

Take the following steps for failed resources:

  1. Correct the faulted resource

    Correct the problem in the failed resource. For details, see "PRIMECLUSTER Reliant Monitor Services (RMS) with Wizard Tools Configuration and Administration Guide."

    Note

    If you are using an operation management product other than a PRIMECLUSTER product, you may need to take corrective actions prescribed for that product.

    For details, see the manual provided with each operation management product.

    (Example) Symfoware

  2. Recover the cluster application

    At the RMS main window, check the state of the cluster application to which the corrected resource is registered. If the cluster application is in the Faulted state, execute the Fault clear operation.

    For details on the Fault clear operation, see "7.2.2.4 Bringing Faulted Cluster Application to available state."

  3. Clear the fault trace of the failure resource

    Clear the fault trace of the failure resource. For more information, refer to "7.2.3.3 Clearing Fault Traces of Resources."

7.4.1.3 Recovery of Failed Cluster Interconnect

The following problems can cause cluster interconnect failures.

Contact your system administrator on the network configuration error. The following section describes how to fix hardware related errors.

If any heartbeat error on the cluster interconnect is detected, either of the following messages will be output to the /var/log/messages file.

"CF: Problem detected on cluster interconnect NIC_NAME to node NODE_NAME: missing heartbeat replies. (CODE)"
"CF: Problem detected on cluster interconnect NIC_NAME to node NODE_NAME: ICF route marked down. (CODE)"

"NIC_NAME" indicates the network interface card on which the error is detected.

"NODE_NAME" indicates the CF node name on which the error is detected.

"CODE" indicates the necessary information to determine the cause.

When either of the above messages is output to the file, follow the steps below.

Corrective action

  1. Determining the failed node

    Confirm that each device is working properly. You can also use the ping command to determine the failed node and its location.

    Note

    When an error on the entire cluster interconnects (all interconnects for every node) occurs, the cluster system forcibly shut down all the nodes except one which has the highest survival priority.

    For details on survival priority, see "5.1.2 Setting up the Shutdown Facility."

    If an error on an active node (e.g. LAN card error of a node on which an active cluster application resides) occurs, you must stop the node before fixing it. To minimize the down time, make sure to follow the steps below before performing "Step 2. Performing maintenance tasks."

    1. Stopping a node in the "Online" state

      Before performing the maintenance task, stop the node on which "Online" cluster application resides.

    2. Starting the forcefully terminated node

      Start the node which was forcefully terminated by the cluster system and make the cluster application back to the "Online" state. For details on how to start a cluster application, see "7.2.1.1 Starting RMS."

      Be sure to check that the node, which is described in Step 1. Stopping a node in the "Online" state, is completely stopped before performing this step.

  2. Performing maintenance tasks

    After determining the cause of the error, perform the following maintenance task depending on the category of error.

    Note

    For a LAN card error, the failed node must be stopped to perform the maintenance task.

    For an error on cables or hubs, you can perform the maintenance task with the node being active.

    • When the error was caused by your LAN card or cable

      If the cable is unplugged, plug in properly.
      If the cable is properly plugged, your LAN card might be the cause. Contact field engineers.

    • When the error was caused by a hub

      If the power is off , push the power button.
      If the power is on, there is a possibility the hub is broken down. Contact field engineers.

  3. Recovery

    To recover the partial failure of the cluster interconnect, skip to "Step 2. Cluster interconnect recovery" below.

    1. Starting all the nodes

      Start all the nodes.

    2. Cluster interconnect recovery

      Use the ping command to confirm if nodes can communicate each other through the failed cluster interconnect.

    After confirming that the cluster interconnect is recovered successfully, clear the "Faulted" state of the cluster application as necessary. For details on the operation, see "7.2.2.4 Bringing Faulted Cluster Application to available state."