F.2.3 Collecting Investigation Material with FJQSS

By using FJQSS (information collection tool), the same information can be collected when using fjsnap -a.

FJQSS is automatically installed if this software is installed.

How to collect the material by using FJQSS is as follows.

For details, see the manual of FJQSS.

  1. Log in with superuser authority.

  2. Execute the fjqss_collect command.

    # /opt/FJSVqstl/fjqss_collect outdir

    For outdir, specify the path of the output directory of the material.

    If outdir is omitted, the material is output in the /var/tmp.

  3. On the screen to select the product, select PRIMECLUSTER GD.

    For the cluster system, when selecting the cluster software of PRIMECLUSTER, all the investigation materials including GDS can be collected at once.

After the materials are collected, the output directory of the investigation material is displayed.

Send the material collected in the displayed output directory to field engineers.