Top
PRIMECLUSTERGlobal Disk Services Configuration and AdministrationGuide 4.5
FUJITSU Software

E.4.2 Warning Messages (62000-62099)


62000

WARNING: spare disk disk too small

Explanation

The size of disk is too small and may not function as a spare disk.

Resolution

Specify a larger disk, and execute the command again.


62001

WARNING: device: write error, errno=errno

Explanation

A write error occurred in physical disk device.

Resolution

If device is a write-locked disk that is connected to a switch group, no action is required. Otherwise, remove device from the class and check the status of device.


62002

WARNING: group: free blocks are reduced

Explanation

Free blocks on group were reduced.

Resolution

You may not be able to create a volume with sufficient capacity. Execute commands as needed and attempt recovery.


62003

WARNING: another disk must be connected to group

Explanation

You must connect another disk to group.

Resolution

Connect another disk.


62004

WARNING: object: copying not completed successfully

Explanation

Synchronization copying did not complete successfully.

Resolution

Disk failure may have occurred. Identify the cause by referring to GDS log message and syslog message.


62005

WARNING: object: gave up wait for the completion of copying by a cancel request

Explanation

Synchronization copying was canceled before completion.

Resolution

Check the status of the object object. If the copying is in progress, there is no need to work around. If it is not in progress, re-execute the copying where it is necessary.
For details, see "Appendix D Command Reference."


62006

WARNING: cannot set use-nvramrc? parameter to true, NVRAMRC not empty

Explanation

Since a command is already registered with NVRAMRC, use-nvramrc? parameter cannot be set to "true."

Resolution

For details, see "A.2.9 System Disk Mirroring."


62007

WARNING: group: no spare disk available

Explanation

There is no valid spare disk in group.

Resolution

Define a spare disk as needed.


62008

WARNING: object.volume: cannot attached due to in status status

Explanation

Slice object.volume could not be attached since it is in status status.

Resolution

Check the slice status and cancel status status as needed.


62009

WARNING: volume: no need to resize volume

Explanation

There was no need to resize the volume volume.

Resolution

No particular resolution required.


62010

WARNING: disk.volume: special file(s) not found

Explanation

Special file for slice disk.volume could not be found.

Resolution

No particular resolution required.


62011

WARNING: node: node in stopped status 

Explanation

node is in STOP status.

Resolution

No particular resolution required. However, promptly activating the node is recommended.


62012

WARNING: node: node in abnormal status

Explanation

node is in abnormal status.

Resolution

No particular resolution required. However, promptly recovering the node and activating it normally is recommended.


62013

WARNING: object: already in status status

Explanation

object is already in status status.

Resolution

No particular resolution required.


62014

WARNING: disk : device : write error, errno=errno

Explanation

A write error occurred on physical disk device.

Resolution

If device is a write-locked disk that is connected to a switch group, no action is required. In other situations, have device exchangeable and check its status.


62015

WARNING: disk : device : node: write error, errno=errno

Explanation

A write error occurred on physical disk device on node node.

Resolution

If device is a write-locked disk that is connected to a switch group, no action is required. In other situations, have device exchangeable and check its status.


62016

RNING: object: no need to update attribute value

Explanation

There was no need to change object attributes.

Resolution

No particular resolution required.


62017

WARNING: pslice: entry in /etc/vfstab not updated, unsupported file system type fstype

Explanation

Entry in the /etc/vfstab file relevant to the physical slice pslice was not updated since fstype is a file system type not supported by the sdxroot command.

Resolution

Edit the /etc/vfstab file or change the file system configuration according to need.

62018

WARNING: correct /etc/vfstab and file system configuration before rebooting, or system may not be booted

Explanation

Invalid entry is included in the /etc/vfstab file. If such file system entry as /(root), /usr, and /var essential to system start-up is invalid, the system cannot be started when rebooted.

Resolution

Refer to a GDS's WARNING message output just before this message and pinpoint the invalid entry in the /etc/vfstab file. Be sure to repair the /etc/vfstab file and the file system configuration as appropriate prior to rebooting the system.

62019

WARNING: volume: entry in /etc/vfstab not updated, unsupported file system type fstype

Explanation

Since file system type fstype is not supported, entry in /etc/vfstab file for volume could not be updated.

Resolution

Directly edit /etc/vfstab as necessary.


62020

WARNING: ignored parameter param for EC

Explanation

Since EC function will be used for copying, parameter param was ignored.


62021

WARNING: ignored parameter param for OPC

Explanation

Since OPC function will be used for copying, parameter param was ignored.


62022

WARNING: ignored parameter param for TimeFinder

Explanation

Parameter param was ignored for copying with TimeFinder.


62023

WARNING: ignored parameter param for SRDF

Explanation

Parameter param was ignored for copying with SRDF.


62024

WARNING: proxy: no session

Explanation

No copy session exists between the proxy proxy and the master

Resolution

No special action is required.