When the replacement of the CT occurred due to the failure of terminal hardware that installs the client (CT), set the (Master) Management Server and terminal according to the following procedure and to make terminal before replacement judged to be the same as that after replacement.
Settings of the (Master) Management Server
Start Server settings tool.
Refer to "8.11.1 Start Server Settings Tool" for details.
Select Stop Service from the Service menu of the Server Settings Tool window.
The confirmation window for stopping service is displayed. Click the OK button.
Click the System Settings button.
The System Settings window is displayed.
When the MAC Address, Owner and OS Type have been modified, the item modified as Same CT determination condition when registering CT will be modified as Not use.
Click the Set button.
Select Start Service from the Service menu of the Server Settings Tool window.
The confirmation window for starting service is displayed. Click the OK button.
Settings of the terminal to install the client.
Use the computer name before the change of hardware.
Install client (CT).