Top
PRIMECLUSTER  Web-Based Admin ViewOperation Guide
FUJITSU Software

6.2 Restart

In order to display the GUI screen on the client, Web-Based Admin View needs to be active. However, it requires no extra handling for startup since it is automatically started on the management server or monitoring node during system startup.

If Web-Based Admin View has to be stopped for some reason such as setup modification of management server or monitoring node, execute two commands with system administrator authority as shown in the procedure below.

Procedure

- For RHEL6

  1. # /etc/opt/FJSVwvbs/etc/bin/wvCntl restart

  2. # /etc/init.d/fjsvwvcnf restart

- For RHEL7

  1. # /etc/init.d/fjsvwvbs restart

  2. # /etc/init.d/fjsvwvcnf restart

Note

  • Be aware that the Web-Based Admin View screen is closed on all clients when restarting. If you change the settings while the Web-Based Admin View screen is active, the following message might be displayed: "0007 Management server session disconnected. Do you want to try to re-connect working Management Server?"

  • With the 2-tier architecture model in which the monitoring node acts as a management server, Web-Based Admin View on the monitoring node is restarted.

  • Be sure to restart Web-Admin View after the following operations.

    • Modification of the http port number or RMI port number

    • Modification of the management server

    • Modification of the Java environment

    • Modification of the network address used by a Web-Based Admin View

    • Modification of the environment variable by executing a command

    • Modification of the secondary management server automatic migration

    • Modification of the connections to an active management server