Top
ETERNUS SF Storage Cruiser V16.5 Operation Guide for Optimization Function
FUJITSU Storage

7.1.2 Confirmation and Measures of Achievements for Performance Objectives for Automated QoS Function

Check whether or not the performance goal for the Automated QoS function is achieved.

When Checking with FTV Overview Screen

See the QoS Available Volume column on the FTV Overview screen.

When Checking with Commands

Execute the esfadm volume qosinfo command and check the "TUNING STATUS" column in the command output.

Process based on the value of the following confirmation results:

Point

The time for the previous automatic tuning can be confirmed from the "SET TIME" column of the esfadm volume qosinfo command or from the FTV Overview Set Time column. If automatic tuning has never been performed in the past, instead of a time and date, a hyphen (-) is displayed. For contending volumes, "Stopping" may be displayed. This indicates that tuning by Automated QoS is not being performed.