4.11.1 Action for Execution Result of Relocation

Take the following actions according to relocation results.

Relocation Result

Description of Result and Action

Normal Suspended

It is possible that Evaluation/Relocation were executed when relocation was in progress. Or it is possible that the time set in Automated Storage Tiering Time Limit was exceeded and the relocation processing was suspended when relocation was in progress.
Check the value set in Evaluation Period or Automated Storage Tiering Time Limit in the policy to consider extending the time so that relocation can be executed.

It is possible that the pool ran out of free space when relocation was in progress, causing the relocation processing to be suspended.
After expanding Tier pool capacity or referring to "2.2 Configuration of Tier Pool" to secure the reserved area required for evaluation/relocation, execute evaluation/relocation.

Error Finished

It is possible that ETERNUS SF Manager is not properly running.
After checking the ETERNUS SF Manager running status, re-execute relocation.

Error Suspended

It is possible that any fault occurred in the device.
It is possible that the relocation processing did not finish normally. On completion of relocation of all the FTVs, execute the esfast relocation stop command.

If relocation does not finish normally in spite of actions taken, there may be a different issue. Collect the information required for troubleshooting and contact Fujitsu Technical Support.