Top
ETERNUS SF Storage Cruiser V16.5 Operation Guide for Optimization Function
FUJITSU Storage

4.10.3 Required Operation after RAID Group Deletion

When the deletion of RAID groups causes a sub-pool in which the RAID groups exist to be deleted, the configuration of the Tier pool and FTV is changed because the tier configuration of a Tier pool containing the sub-pool is changed.
When continuing to run Automated Storage Tiering, reconfigure the Tiering policy of the Tier pool and reconfigure the changes in the content to re-implement Automated Storage Tiering if necessary.
The changes in the content are as follows.

Point

The status of the RAID group and the status of the RAID reduction for the Tier pool can be checked in the Web Console. Refer to "4.3 Confirmation of Configuration Details of Tier Pool" for details.