XSCF SNMP shutdown agent is the shutdown agent for SPARC M10 and M12.
For details on XSCF, see "Fujitsu SPARC M12 and Fujitsu M10/SPARC M10 System Operation and Administration Guide."
Setup and configuration
The XSCF must be configured according to "Fujitsu SPARC M12 and Fujitsu M10/SPARC M10 System Operation and Administration Guide."
Moreover, you must set the user name and password to allow the operation in XSCF.
For details, see "5.1.2.1.1 Checking XSCF Information" and "5.1.2.1.2 Setting SNMP" of the "PRIMECLUSTER Installation and Administration Guide."
Shutdown Agent
There are six kinds of XSCF SNMP SAs:
SA_xscfsnmpg0p-panics the domain by using XSCF-LAN#0
SA_xscfsnmpg1p-panics the domain by using XSCF-LAN#1
SA_xscfsnmpg0r-resets the domain by using XSCF-LAN#0
SA_xscfsnmpg1r-resets the domain by using XSCF-LAN#1
SA_xscfsnmp0r-resets PPAR by using XSCF-LAN#0 (Used only on the control domain)
SA_xscfsnmp1r-resets PPAR by using XSCF-LAN#1 (Used only on the control domain)
The priority of each agent is as follows:
SA_xscfsnmpg0p
SA_xscfsnmpg1p
SA_xscfsnmpg0r
SA_xscfsnmpg1r
SA_xscfsnmp0r
SA_xscfsnmp1r
The XSCF log files are as follows:
/var/opt/SMAWsf/log/SA_xscfsnmpg0p.log /var/opt/SMAWsf/log/SA_xscfsnmpg1p.log /var/opt/SMAWsf/log/SA_xscfsnmpg0r.log /var/opt/SMAWsf/log/SA_xscfsnmpg1r.log /var/opt/SMAWsf/log/SA_xscfsnmp0r.log /var/opt/SMAWsf/log/SA_xscfsnmp1r.log
Note
To make XSCF-LAN redundant, XSCF-LAN#0 and XSCF-LAN#1 should use different subnets.
After Shutdown Facility (SF) startup, it can take up to 30 seconds to detect hardware failures such as XSCF errors or disconnected cable, and setting errors like incorrect IP addresses.