Top
Systemwalker Desktop Patrol Operation Guide: for Administrators
FUJITSU Software

13.7.3 Example of Outputting Power Consumption Status

The report is composed of "Summary Part", "PC Availability", "List of Power Consumption", and "Details Part".

The following describes each of the "Summary Part", "PC Availability", "List of Power Consumption", and "Details Part".

Summary part

The "Summary Part" when saved as file is as follows.

The content of the above file is as follows.

Item

Description

Fujitsu Software

(The set value is displayed)

It is the information set in Company Name of the Basic Information tab.

Seal Column

It is the column for sealing on the created file. Here, since only the column for sealing is printed, use it freely.

Power Consumption Status

(The set value is displayed)

It is the information set in Title of the Basic Information tab.

Target

It is the name of section or location as object.

It is the information set in Section Name and Setup Name of the Option tab.

Target PC(s) No.

Among all PC in the section or location as the object, the version of CT is V14 or later, and it is the number of PCs working in the current month.

Author Name

Author of the file.

it is the information set in Author Name of the Basic Information tab.

Creation Date

It is the date when file has been created.

It is the information set in Creation Date of the Basic Information tab.

Audit Period

It is the period of month as auditing object.

It is the information set in Audit Period in the Basic Information tab.

Estimation Value and Reduction Effects of Power Consumption

Output Power consumption reduction amount of Power consumption, reduction amount of CO2, estimation value of current month and total value of the year separately.

Reference Information of Power Consumption

Output the following information as the comparison information to the last month.

  • Power consumption

  • Average power consumption

  • Target PC(s) No.

  • Long-Running PC(s) No.

  • Reduction in Electricity Consumption

Transition of Power - The Last Three Months

Output the power consumption in the last 3 months and total of number of PCs by weeks.

Trend of Power Consumption of This Year

Output the power consumption of this year and total number of PCs by months.

When the data of power consumption of last year exists, output the total.

Comparison with Pre-Year

Output the total value of last year and this year based on the month set in aggregation month. The predicted value till the end month of the year will be output for this year.

Example: Set the aggregation month to March, and the current month is Nov. 2008

Period of last year: April 2007 ~ March 2008

Period of this year: April 2008 ~ October 2008

November 2008 ~ March 2009 (Prediction value)

Calculation method of prediction value:

Get the monthly average of the actual achievement of this year, multiply it with the number of remaining months to get the prediction value.

Low achievement rates

Output 5 sections with low achievement rates/locations according to the average power consumption of one PC of each section/location.

Comment

It is the input column for comment such as opinions.


PC availability

The "PC Availability" when saved as file is as follows.

The content of the above file is as follows.

Item

Description

Power Saving Settings

It is the setting name of power saving setting as the object.

Target PC(s) No.

It is the PC set in the power saving setting as report object, and the number of PCs that are working in the current month.

Simulation of Power Consumption

Output the result of simulated power consumption. The following four types of result will be output.

  1. When power saving setting is not applicable

    Calculate not as the power saving operation in PC operation.

  2. When power saving setting is applicable

    The current actual performance value is equivalent to this.

  3. In the above "b" and PC without long-time operation

    Example: when 160h is set as the judgment standard of operation time

    PCs that work over 160h will be calculated as working 160h.

  4. In the above "c" and PC without CRT display

    Calculate the power consumption when replacing the CRT display with LCD. Without CRT display, the output value remains the same as "c".

Percentage of Total Operation Hour

Output the rate of PC that works long-time with pie chart.

Rate of Days of 24h Operation

Output the rate of PC that works 24h with pie chart.

Trend of PC Operation Status

Output the average number of PC of 24h operation in the specified period and power consumption with a graph.

Low achievement rates

Output 5 sections with low achievement rates/location of reduced achievement rate of PC of long-time operation.


List of power consumption

The "List of Power Consumption" when saved as file is as follows.

Item

Description

No.

It is the number allocated to the information that has been output.

Section/Setup Place

It is the information of section/location.

PCs

It is the number of PCs of section/location.

  • Pre-Month:

    It is the number of PCs as auditing object last month.

  • This Month:

    It is the number of PCs as auditing object this month.

Pwr-Consumption

It is the power consumption of section/location.

  • Pre-Month:

    It is the power consumption of last month.

  • This Month:

    It is the power consumption of this month.

Pwr-Consumption of Each PC

It is the average power consumption of each PC in section/location.

  • Pre-Month:

    It is the average power consumption of each PC of last month.

  • This Month:

    It is the average power consumption of each PC of this month.

When the Non-Power Saving

Pwr-Consumption

It is the assumed value of power consumption in non power saving calculated from the actual achievement of PC.

Reduction

It is the differential value between power consumption and power consumption in non power saving of current month.


Details part

The "Details Part" when saved as file is as follows.

The content of the above file is as follows.

Section (it is Setting Location when specifying location unit), Related Asset Number, Asset Number are arranged and displayed in ascending order.

Item

Description

W or E

It shows the status of operation time.

W: PC that is not working (operation time is 0h).

E: PC that is working long-time (operation time is more than the specified time).

No.

It is the number allocated to the information that has been output.

Section

It is the information of section.

User Name

It is the user name that uses the machine.

Phone No.

It is the telephone number of the user name that uses the machine.

Asset Number

It is the asset number of machine.

Setup Place

It is the setting location information of machine.

Type

It is the type information of machine.

HW Type

It is the hardware type information of machine.

(Output the type of desktop/laptop/server/virtual PC.)

Availability

It is the availability of machine.

Device Name

It is the name to be used as machine.

Collection Date/Time

It is the date and time when information has been registered.

User Memo

Output the selected user memo only when Output User Memo is selected in the Option tab.

Power Saving Settings

It is the setting name of power saving setting.

Allow/Not Allow Audit

Output whether auditing is allows.

  • Allow:

    PC that can collect power saving information and can be audited

  • Not allowed:

    PC that cannot be audited since CT does not collect power information (the CT prior to V13.3 is used, or imported through linking with other product .etc)

Power Consumption of Pre-Month

It is the power consumption of last month.

Power Consumption

It is the power consumption of this month.

Total Operation Hour

It is the total operation hours.

System Standby Time

It is the total hours of system standby.

24h Operation Days

It is the total number of days of 24h operation.


Note

If Connection Server in the Server tab of the Environment Setup window of CT is changed from the host name specified when building CS or DS, then the new server may be judged not to be an auditing target and may not be aggregated.