This section explains information about incompatibility between V3.1.1/V3.1.1A and V3.1.0A.
Details of Modification
When creating L-Platform templates, resource pools are displayed as options for the following items even if they have unregistered resources:
VM or server pools (spare server pools) of the server
Storage pool of the server system disk
Storage pool of the server data disk
Resource pools are no longer displayed as options in V3.1.1 if their resources are not registered.
Corrective Actions
Create an L-Platform template after registering resources with the resource pool.
Details of Modification
In previous versions, if an L-Platform was deployed using CreateLPlatform, servers were deployed with the names as specified in the L-Platform template, even if the names conflicted in the template.
In addition, if server names conflicted in a deployed L-Platform, it caused the following problems:
It was difficult to identify servers displayed in the event log.
Server names needed to be changed when the L-Platform was reconfigured.
In V3.1.1/V3.1.1A, with the improved server name checking of CreateLPlatform, servers are deployed with names appended with sequential numbers if the names conflict in the L-Platform template.
Corrective Actions
To deploy servers with the names as specified in an L-Platform template, specify unique server names within the template.
Details of Modification
In previous versions, when an L-Platform was created, copied, or edited, added servers were placed with as many NICs as the maximum number of NICs of the image information.
In V3.1.1, an added server is placed with one NIC.
Corrective Actions
To attach as many NICs as the maximum number of NICs, click the server icon, and then click the [Add NIC] button to add NICs.
Details of Modification
There are following changes about the accounting information setting for system disks.
The unit price of system disks is included in the unit price of the product of Virtual L-Servers or Physical L-Servers.
The product category for system disk capacity is added to the accounting information setting.
The unit price of system disks is set as a product of system disk capacity.
Corrective Actions
If the manager has been newly installed, or the manager has been upgraded and snapshot accounting has been enabled in the procedure:
Set the unit prices of the system disks as the products of system disk capacity in the accounting information setting.
If it is not necessary to charge for the system disks, specify 0s for the unit prices of the system disks or do not define the products of system disk capacity.
If system disk accounting has not been enabled in the upgrade installation procedure:
There is no incompatibility. No action is required.
For details on the upgrade installation procedure, refer to "C.2 Manager" in "Setup Guide CE".
Details of Modification
There are following changes about the identification information of servers in the Usage Charge Detail window.
Internal IDs are displayed as the identification information of virtual or physical servers in the Usage Charge Detail window.
Server names specified in the L-Platform management are displayed as the identification information of virtual or physical servers in the Usage Charge Detail window.
Corrective Actions
When the ROR manager is newly installed, or the server name display is set to effective in the upgrade installation procedure:
Distinguish each server referring to the server name in the Usage Charge Detail window.
When the server name display is not set to effective in the upgrade installation procedure:
There is no incompatibility. No action is required.
Refer to "C.2 Manager" in the "Setup Guide CE" for information on the upgrade Installation.
Details of Modification
There are following changes about the identification information of data disks in the Usage Charge Detail window.
Internal IDs are displayed as the identification information of data disks in the Usage Charge Detail window.
Disk names specified in the L-Platform management are displayed as the identification information of data disks in the Usage Charge Detail window.
Corrective Actions
When the ROR manager is newly installed, or the data disk name display is set to effective in the upgrade installation procedure:
Distinguish each data disk referring to the disk name in the Usage Charge Detail window.
When the disk name display is not set to effective in the upgrade installation procedure:
There is no incompatibility. No action is required.
Refer to "C.2 Manager" in the "Setup Guide CE" for information on the upgrade Installation.
Details of Modification
The messages displayed in the following cases have been changed:
Message Output when Creation of a Virtual Switch Failed
Error codes included in the message output when creation of a virtual switch fails (FJSVrcx:ERROR:62700) have been changed from 500 and 1601 to FJSVrcx:ERROR:62721.
For V3.1.0A
FJSVrcx:ERROR:62700:name:virtual switch creation failed on server server (500)
FJSVrcx:ERROR:62700:name:virtual switch creation failed on server server (1601)
For V3.1.1/V3.1.1A
FJSVrcx:ERROR:62721:name:failed to create virtual switch with NIC (number) on server server, detail=detail
Error Message Output when a Communication Error with VM Management Software Occurred
The error message which was output when a communication error with a VM management software occurred (FJSVrcx:ERROR:69111) was output periodically for each storage resource. It is now output only once for each VM management software.
For V3.1.0A
The following message is output periodically for each virtual storage resource
When using VMware vCenter Server for VM management software
FJSVrcx:ERROR:69111:communication error. target=IP address of the VM management software detail=VMware vCenter Server communication error(Virtual storage resource name)
When using System Center Virtual Machine Manager for VM management software
FJSVrcx:ERROR:69111:communication error. target=IP address of the VM management software detail=System Center Virtual Machine Manager communication error(Virtual storage resource name)
When using Oracle VM Manager for VM management software
FJSVrcx:ERROR:69111:communication error. target=IP address of the VM management software detail=Oracle VM Manager communication error(Virtual storage resource name)
For V3.1.1/V3.1.1A
The following message is output only once for each VM management software
When using VMware vCenter Server for VM management software
FJSVrcx:ERROR:69111:communication error. target=IP address of the VM management software detail=VMware vCenter Server communication error
When using System Center Virtual Machine Manager for VM management software
FJSVrcx:ERROR:69111:communication error. target=IP address of the VM management software detail=System Center Virtual Machine Manager communication error
When using Oracle VM Manager for VM management software
FJSVrcx:ERROR:69111:communication error. target=IP address of the VM management software detail=Oracle VM Manager communication error
Corrective Action
It is necessary to modify the message for the target of monitoring, when monitoring the messages (numbers or message text) for Resource Orchestrator using other vendors' products.
It is necessary to update the operation guide, when the messages before modification are described in an operation guide created by users.