This section explains how to change the user name and password for iRMC.
Operation Procedure:
Execute the following command on all nodes to stop the shutdown facility.
# sdtool -e
Change the user name and password according to the procedure for IPMI.
Encrypt the password.
# /opt/SMAW/SMAWsf/bin/sfcipher -c
Enter Password:
Re-Enter Password:
D0860AB04E1B8FA3
Define the changed user name and the encrypted password for iRMC in the Shutdown Agent configuration file.
See
For details on how to define the configuration file, see "5.1.2.3.2 IPMI."
Execute the following command on any node to apply changes of the configuration file.
# /etc/opt/FJSVcllkcd/bin/panicinfo_setup
After the following message is displayed, select "I."
panicinfo_setup: WARNING: /etc/panicinfo.conf file already exists. (I)nitialize, (C)opy or (Q)uit (I/C/Q) ?
Execute the following command on all nodes to start the shutdown facility.
# sdtool -b
Execute the following command on all nodes and check that the shutdown facility operates normally.
# sdtool -s
Note
There is a possibility that the mistake is found in the configuration setting of the agent or hardware when displayed as follows though changing the setting of the shutdown facility is completed.