This section explains how to change the IPMI IP address.
Operation Procedure:
Execute the following command on all nodes to stop the shutdown facility.
# sdtool -e
Change the IP address according to the IPMI procedure.
Define the changed IP address in the Shutdown Agent configuration file.
See
For details on how to define the configuration file, see "5.1.2.3.2 IPMI."
Execute the following command on any node to apply changes of the configuration file.
# /etc/opt/FJSVcllkcd/bin/panicinfo_setup
After the following message is displayed, select "I."
panicinfo_setup: WARNING: /etc/panicinfo.conf file already exists. (I)nitialize, (C)opy or (Q)uit (I/C/Q) ?
Execute the following command on all nodes to start the shutdown facility.
# sdtool -b
Execute the following command on all nodes and check that the shutdown facility operates normally.
# sdtool -s
Note
There is a possibility that the mistake is found in the configuration setting of the agent or hardware when displayed as follows though changing the setting of the shutdown facility is completed.
"InitFailed" is displayed as the initial status.
"Unknown" or "TestFailed" is displayed as the test status.
In this case, review the configuration setting of the agent or hardware.