This section explains how to change the user name and password to control the console after installation of the PRIMECLUSTER system.
Operation Procedure:
Execute the following command on one of the cluster nodes to stop RMS operation.
# /opt/SMAW/bin/hvshut -a
Execute the following command on each cluster node to stop the shutdown facility.
# /opt/SMAW/bin/sdtool -e
Change the following user names and passwords registered to the shutdown facility as necessary:
User name and password to login to XSCF (for SPARC M10)
For XSCF, see "5.1.2.1.3 Using the Shutdown Configuration Wizard" and reconfigure the user name and password to log in to XSCF.
User name and password to login to XSCF (for SPARC Enterprise M3000, M4000, M5000, M8000, and M9000)
For XSCF, see "5.1.2.2.2 Using the Shutdown Configuration Wizard" and reconfigure the user name and password to login to XSCF.
User name and password to login to ALOM
For ALOM, see "5.1.2.4.2 Using the Shutdown Configuration Wizard" and reconfigure the user name and password to login to ALOM.
User name and password to login to ILOM
For ILOM, see "5.1.2.3.2 Using the Shutdown Configuration Wizard" and reconfigure the user name and password to login to ILOM.
After the IP address registered to the shutdown facility is changed, check the state of configuration of shutdown facility for each node by the display screen for the state of configuration of shutdown facility.
"Unknown" is shown during normal system operation. If an error occurs and the shutdown facility stops the relevant node successfully, "Unknown" will change to "KillWorked".
Indicates the state in which the path to shut down the node is tested when a node error occurs. If the test of the path has not been completed, "Unknown" will be displayed. If the configured shutdown agent operates normally, "Unknown" will be changed to "TestWorked".
Indicates the state in which the shutdown agent is initialized.
To exit the configuration wizard, click Finish. Click Yes in the confirmation popup screen that appears.
Note
On this screen, confirm that the shutdown facility is operating normally.
If "InitFailed" is displayed in the Initial state even when the configuration of the shutdown facility has been completed or if "Unknown" is displayed in the Test state or "TestFailed" is highlighted in red, the user name and password registered to the shutdown facility may contain an error. Reconfigure the user name and password.
Execute the following command in one of the cluster nodes to start RMS operation:
# /opt/SMAW/bin/hvcm -a