8.3 Changing the User Name and Password to Control the Console

This section explains how to change the user name and password to control the console after installation of the PRIMECLUSTER system.

Operation Procedure:

  1. Execute the following command on one of the cluster nodes to stop RMS operation.

    # /opt/SMAW/bin/hvshut -a
  2. Execute the following command on each cluster node to stop the shutdown facility.

    # /opt/SMAW/bin/sdtool -e
  3. Change the following user names and passwords registered to the shutdown facility as necessary:

    1. User name and password to login to XSCF (for SPARC M10)

      For XSCF, see "5.1.2.1.3 Using the Shutdown Configuration Wizard" and reconfigure the user name and password to log in to XSCF.

      Figure 8.6 XSCF (SPARC M10)

    2. User name and password to login to XSCF (for SPARC Enterprise M3000, M4000, M5000, M8000, and M9000)

      For XSCF, see "5.1.2.2.2 Using the Shutdown Configuration Wizard" and reconfigure the user name and password to login to XSCF.

      Figure 8.7 XSCF (SPARC Enterprise M3000, M4000, M5000, M8000, and M9000)

    3. User name and password to login to ALOM

      For ALOM, see "5.1.2.4.2 Using the Shutdown Configuration Wizard" and reconfigure the user name and password to login to ALOM.

      Figure 8.8 ALOM

    4. User name and password to login to ILOM

      For ILOM, see "5.1.2.3.2 Using the Shutdown Configuration Wizard" and reconfigure the user name and password to login to ILOM.

      Figure 8.9 ILOM

  4. After the IP address registered to the shutdown facility is changed, check the state of configuration of shutdown facility for each node by the display screen for the state of configuration of shutdown facility.

    Figure 8.10 Displaying the state of configuration of shutdown facility

    Shut State

    "Unknown" is shown during normal system operation. If an error occurs and the shutdown facility stops the relevant node successfully, "Unknown" will change to "KillWorked".

    Test State

    Indicates the state in which the path to shut down the node is tested when a node error occurs. If the test of the path has not been completed, "Unknown" will be displayed. If the configured shutdown agent operates normally, "Unknown" will be changed to "TestWorked".

    Init State

    Indicates the state in which the shutdown agent is initialized.

    To exit the configuration wizard, click Finish. Click Yes in the confirmation popup screen that appears.

    Note

    On this screen, confirm that the shutdown facility is operating normally.

    If "InitFailed" is displayed in the Initial state even when the configuration of the shutdown facility has been completed or if "Unknown" is displayed in the Test state or "TestFailed" is highlighted in red, the user name and password registered to the shutdown facility may contain an error. Reconfigure the user name and password.

  5. Execute the following command in one of the cluster nodes to start RMS operation:

    # /opt/SMAW/bin/hvcm -a