There are incompatibilities of a setup of the shutdown facility and the shutdown configuration wizard in the following models:
L.1.11.1 For SPARC Enterprise M3000, M4000, M5000, M8000, or M9000
L.1.11.3 For SPARC Enterprise T5120, T5220, T5140, T5240, T5440, or SPARC T3 series
This incompatibility occurs when T006771SP-01 or later is applied to PRIMECLUSTER 4.3A10.
Details on incompatibilities
Changed the screen of the shutdown configuration wizard to set up the shutdown facility for SPARC Enterprise M3000, M4000, M5000, M8000, or M9000.
This incompatibility occurs when T006771SP-01 or later is applied to PRIMECLUSTER 4.3A10.
Changes
There were selection items of SCON from the selection screen of a shutdown agent.
Select RCI Panic, XSCF Panic, Console Break, RCI Reset, and XSCF Reset from the selection screen of a shutdown agent and make settings.
In the setup screen of Wait for PROM, the check box of Wait for PROM has checked by default.
Set a timeout value of a shutdown agent in the setup screen of the timeout value.
One IP address of XSCF can be set.
Deleted the selection items of SCON from the selection screen of a shutdown agent.
When XSCF is selected from the selection screen of a shutdown agent, XSCF Panic, XSCF Break, and XSCF Reset are automatically set.
When XSCF and Use RCI are selected from the selection screen of a shutdown agent, RCI Panic, XSCF Panic, XSCF Break, RCI Reset, and XSCF Reset are automatically set.
In the setup screen of Wait for PROM, the checkbox of Wait for PROM is not checked by default.
Timeout value of a shutdown agent is automatically set.
Up to two IP addresses of XSCF can be set.
Note
None.
Details on incompatibilities
The shutdown configuration wizard is available to set up the shutdown facility for SPARC Enterprise T1000 or T2000.
This incompatibility occurs when T006771SP-01 or later is applied to PRIMECLUSTER 4.3A10.
Changes
Setup of the shutdown facility for SPARC Enterprise T1000 or T2000 is performed by CLI.
Setup of the shutdown facility for SPARC Enterprise T1000 or T2000 is performed by the shutdown configuration wizard.
Note
None.
Details on incompatibilities
The shutdown configuration wizard is available to set up the shutdown facility for SPARC Enterprise T5120, T5220, T5140, T5240, T5440, or SPARC T3 series.
This incompatibility occurs when T006771SP-01 or later is applied to PRIMECLUSTER 4.3A10.
Changes
Setup of the shutdown facility for SPARC Enterprise T5120, T5220, T5140, T5240, T5440, or SPARC T3 series is performed by CLI.
Setup of the shutdown facility for SPARC Enterprise T5120, T5220, T5140, T5240, T5440, or SPARC T3 series is performed by the shutdown configuration wizard.
Note
None.