2.12 Definitions for Monitoring the Execution Status of Job Nets by Linking to Systemwalker Centric Manager

This section explains the definitions for monitoring the execution status of job nets by linking to Systemwalker Centric Manager.

Note

To monitor the job net execution status, Systemwalker Centric Manager should be configured to be capable of monitoring the following messages. The monitored event type is "Batch Job".

[Windows]

  • Systemwalker CentricMGR V10.0L20 or earlier

    AP:jobschExit: ERROR: JOBNET has abnormal ended.
    JobNetComment=xxx JobNetName=xxx Code=xxx
    ProjectName=xxx SubSystemNumber=xxx

  • Systemwalker CentricMGR V11.0L10 or later

    AP:jobschExit: ERROR: JOBNET terminated abnormally.
    JobNetComment=xxx JobNetName=xxx Code=xxx
    ProjectName=xxx SubSystemNumber=xxx

[UNIX]

  • Systemwalker Centric Manager 11.0 or earlier

    UX:jobschExit: ERROR: JOBNET has abnormal ended. JobNetComment=xxx JobNetName=xxx Code=xxx ProjectName=xxx SubSystemNumber=xxx

  • Systemwalker Centric Manager 12.0 or later

    UX:jobschExit: ERROR: JOBNET terminated abnormally. JobNetComment=xxx JobNetName=xxx Code=xxx ProjectName=xxx SubSystemNumber=xxx

    For details on the setting for event monitoring, see the Systemwalker Centric Manager User's Guide - Monitoring Functions.