Top
Systemwalker Operation Manager  Message Guide
FUJITSU Software

2.13 Messages Starting with MpPmonO

This section explains the messages starting with MpPmonO.

These messages are output by Process Monitor.

MpPmonO: INFO: 10000: Started Process Monitor for Systemwalker Operation Manager.

[Description]

Process Monitor has started.

MpPmonO: INFO: 10001: Stopped Process Monitor for Systemwalker Operation Manager.

[Description]

Process Monitor has stopped.

MpPmonO: ERROR: 10002: Check if the Systemwalker Operation Manager process (XXXX) is running properly.

[Description]

Process Monitor detected an error in a Systemwalker process. You need to check the Systemwalker process.

[Parameter]

XXXX: Process name

[System Administrator Response]

Check the operational status of processes with the process running status display command (mppviewo) and terminate the problem process and related processes. Then, start the service/daemon terminated.

If no problem process was found and there is a possibility that the batch startup\stop control file was edited while Systemwalker Operation Manager is running, stop it using the service/daemon termination command (poperationmgr). Then, start Systemwalker Operation Manager using the service/daemon startup command (soperationmgr).

MpPmonO: ERROR: 10003: Could not start Process Monitor for Systemwalker Operation Manager.[YYYY]

[Description]

Failed to start Process Monitor. Process Monitor may not be configured properly.

[Parameter]

YYYY: Error detail code

[System Administrator Response]

The definition information of the Process Monitor function may be incorrect. Check the Common section's value in the operating environment definition file of Process Monitor (mppmon.ini).

Storage location of the operating environment definition file of Process Monitor:

[Windows version]

Systemwalker installation directory\mpwalker.jm\mpcmtool\pmon\etc\mppmon.ini

[UNIX version]

/etc/opt/FJSVftlo/pmon/mppmon.ini

MpPmonO: WARNING: 10005: Process Monitor for Systemwalker Operation Manager failed to obtain the monitored processes.[YYYY] [ZZZZ]

[Description]

Failed to obtain information required for performing Process Monitor.

If you receive any of detail codes from 61 to 65, this can occur if insufficient system resources exist to obtain monitoring information:

  • Detail code: 61

    There is high load on the system due to being unable to generate the process.

  • Detail code: 63

    There is high load on the system due to taking a long time to execute the process.

  • Detail code: 64

    There is high load on the system due to running out of desktop heap.

  • Detail code: 65

    There is high load on the system or I/O due to disk space shortage or because the file system runs out of inodes.

Also, if the monitoring process takes place while anti-virus software is running, monitoring information may fail to be obtained, causing this message to be output.

[Parameter]

YYYY: File name (with full path) or command name (including arguments)

ZZZZ: Error detail code

[System Administrator Response]

  • When the message is output one time:

    No action is required. This message does not affect the operations of Systemwalker Operation Manager.

  • When the message is output for each monitoring interval:

    Collect information for all the functions with the Maintenance Information Collection Tool and contact a Fujitsu's system engineer.

[Windows]MpPmonO: WARNING: 10006: Process Monitor for Systemwalker Operation Manager failed to wait until starting to monitor. Started to Monitor.

[Description]

Failed to wait for Process Monitor startup. An error in a process that has not been started yet may be detected.

[System Administrator Response]

Collect information for the Common Tool function with the Maintenance Information Collection Tool and contact a Fujitsu's system engineer.

[Windows]MpPmonO: WARNING: 10007: Process Monitor for Systemwalker Operation Manager failed to wait interval time. Repeat to monitor.

[Description]

Failed to wait for monitoring intervals of Process Monitor. An error in a process may be detected.

[System Administrator Response]

Collect information for the Common Tool function with the Maintenance Information Collection Tool and contact a Fujitsu's system engineer.

MpPmonO: WARNING: 10008: Process Monitor for Systemwalker Operation Manager may have failed to obtain the monitored processes.[YYYY] [ZZZZ]

[Description]

Obtaining the information required for performing Process Monitor may have failed.

[Parameter]

YYYY: File name (with full path) or command name (including arguments)

ZZZZ: Error detail code

[System Administrator Response]

Collect information for all the functions with the Maintenance Information Collection Tool and contact a Fujitsu's system engineer.

MpPmonO: WARNING: 10009: Process Monitor for Systemwalker Operation Manager failed to process partial termination. Partial termination may not be monitored properly.[YYYY]

[Description]

An error occurred in the internal processing of Process Monitor which handles partial termination of Systemwalker. The process that is terminated at partial termination may be detected as an error.

[Parameters]

YYYY: IP address of local host

[System Administrator Response]

Collect information for the Common Tool function with the Maintenance Information Collection Tool and contact a Fujitsu's system engineer.

MpPmonO: WARNING: 10010: Process Monitor for Systemwalker Operation Manager detected an error, but did not send notification.

[Description]

Process Monitor detected an error, but it failed to send the error notification.

[System Administrator Response]

Collect information for all the functions with the Maintenance Information Collection Tool and contact a Fujitsu's system engineer.

[Windows]MpPmonO: WARNING: 10011: Process Monitor for Systemwalker Operation Manager failed to stop service.[YYYY]

[Description]

Failed to stop the Process Monitor service.

[Parameters]

YYYY: Error detail code

[System Administrator Response]

Collect information for the Common Tool function with the Maintenance Information Collection Tool and contact a Fujitsu's system engineer.

[Windows]MpPmonO: WARNING: 10012: Process Monitor for Systemwalker Operation Manager skipped monitoring, because of resource lack.

[Description]

Process Monitor is not currently available since the system is overloaded.

[System Administrator Response]

Wait until the system becomes stable and resumes monitoring. If the message does not appear consecutively, you can resume monitoring.

[Windows]MpPmonO: WARNING: 10013: Process Monitor for Systemwalker Operation Manager failed to get process information.So, skipped monitoring.

[Description]

Process Monitor failed to obtain the process information from the system.

[System Administrator Response]

Wait until monitoring is resumed. If the message does not appear consecutively, you can resume monitoring.

MpPmonO: WARNING: 10015: Process Monitor for Systemwalker Operation Manager failed to notify Operation Management Client.

[Description]

Process Monitor failed to send the error notification to the Operation Management Client.

Error notification to Operation Management Clients is enabled only when an Operation Management Server of Systemwalker CentricMGR V10.1/V10.0L20 or later is installed. This time, the function may have been activated in an environment where supported Operation Management Server is not installed.

[System Administrator Response]

The definition information of the Process Monitor function may be incorrect. Check the Notification section's value in the operating environment definition file of Process Monitor (mppmon.ini).

Storage location of the operating environment definition file of Process Monitor:

[Windows version]

Systemwalker installation directory\mpwalker.jm\mpcmtool\pmon\etc\mppmon.ini

[UNIX version]

/etc/opt/FJSVftlo/pmon/mppmon.ini

MpPmonO: WARNING: 10016: Process Monitor for Systemwalker Operation Manager failed to notify upstream server of error properly.

[Description]

Process Monitor failed to send the error notification to the upstream server.

Error notification to upstream servers is enabled only when Systemwalker CentricMGR V10.1/V10.0L20 or later is installed. This time, the function may have been activated in an environment where supported Systemwalker CentricMGR is not installed.

[System Administrator Response]

Collect information for all the functions with the Maintenance Information Collection Tool and contact a Fujitsu's system engineer.

MpPmonO: WARNING: 10017: Process Monitor for Systemwalker Operation Manager failed to execute the customized command.

[Description]

Process Monitor did not execute the user-defined command to send the error notification.

[System Administrator Response]

Collect information for the Common Tool function with the Maintenance Information Collection Tool and contact a Fujitsu's system engineer.

MpPmonO: WARNING: 10018: Process Monitor for Systemwalker Operation Manager failed to obtain information on error notification.[YYYY]

[Description]

Failed to obtain the information required for the error notification of Process Monitor.

[Parameters]

YYYY: Error detail code

[System Administrator Response]

The definition information of the Process Monitor function may be incorrect. Check the Notification section's value in the operating environment definition file of Process Monitor (mppmon.ini).

Storage location of the operating environment definition file of Process Monitor:

[Windows version]

Systemwalker installation directory\mpwalker.jm\mpcmtool\pmon\etc\mppmon.ini

[UNIX version]

/etc/opt/FJSVftlo/pmon/mppmon.ini

MpPmonO: WARNING: 10019: Definition on the notified server for Process Monitor for Systemwalker Operation Manager is invalid.[YYYY]

[Description]

An invalid server is specified as the notification destination in the definition information of Process Monitor.

[Parameters]

YYYY: Error detail code

[System Administrator Response]

The definition information of the Process Monitor function may be incorrect. Check the Notification section's value in the operating environment definition file of Process Monitor (mppmon.ini).

Storage location of the operating environment definition file of Process Monitor:

[Windows version]

Systemwalker installation directory\mpwalker.jm\mpcmtool\pmon\etc\mppmon.ini

[UNIX version]

/etc/opt/FJSVftlo/pmon/mppmon.ini

MpPmonO: WARNING: 10020: Process Monitor for Systemwalker Operation Manager failed to notify upstream server of error properly. Notified server may not be defined.[YYYY]

[Description]

Process Monitor failed to send the error notification to the upstream server.

Error notification to upstream servers is enabled only when Systemwalker CentricMGR V10.1/V10.0L20 or later is installed. This time, the function may have been activated in an environment where supported Systemwalker CentricMGR is not installed. Or, the destination server may not be defined for the System Monitor function of Systemwalker Centric Manager.

[Parameter]

YYYY: Error detail code

[System Administrator Response]

The notification destination defined for System Monitor is used for that for Process Monitor. Check if the notification destination for System Monitor has been set correctly.

MpPmonO: WARNING: 10021: Invalid host IP address is specified for Process Monitor for Systemwalker Operation Manager.[YYYY]

[Description]

The IP address of the local host specified in the definition information of Process Monitor is invalid.

[Parameters]

YYYY: Error detail code

[System Administrator Response]

The definition information of the Process Monitor function may be incorrect. Check the Notification section's value in the operating environment definition file of Process Monitor (mppmon.ini).

Storage location of the operating environment definition file of Process Monitor:

[Windows version]

Systemwalker installation directory\mpwalker.jm\mpcmtool\pmon\etc\mppmon.ini

[UNIX version]

/etc/opt/FJSVftlo/pmon/mppmon.ini

MpPmonO: WARNING: 10022: Process Monitor for Systemwalker Operation Manager failed to notify upstream server of error properly. Could not obtain the IP address.[YYYY]

[Description]

The system failed to obtain the IP address of the local host during internal processing of Process Monitor.

[Parameter]

YYYY: Error detail code

[System Administrator Response]